• Thispowersupplyisforusewithlandscapelightingsystemsonly.
• Donotsubmergetransformer.
• Thisdeviceisacceptedasacomponentofalandscapelightingsystem
wherethesuitabilityofthecombinationshallbedeterminedbyCSAor
localauthoritieshavingjurisdiction.TocomplywithCSArequirement,this
xtureshouldbeinstalledbyaqualiedelectrician.AuCanada.Pourêtre
enaccordavecIES1015CSA.Celuminairedoitêtreinstalléparun
électricienqualié.
• WARNING:Riskofelectricshock,useonlywithlowvoltagelandscape
xturesandaccessories.DOnotusewithswimmingpoolorspalighting
xtures.
• Donotconnecttwoormorepowersuppliesinparallel.
• Foroutdooruseonly.
• NationalElectricalCoderequiresthatwiringwhereconcealedorextended
throughabuildingwallmustbeenclosedinconduit.
• Transformershouldbemountedclosetopowersupply.Extensioncords
shouldnotbeusedwiththisunit.
• WARNING:(forPowerSupplyCordconnectedPOWERUNIT)
RISK OF ELECTRIC SHOCK.Installpowerunit5feet(1.5m)ormore
fromthepool,spa,orfountainwherethepowerunitisinstalled(a)
indoorwithin10feet(3.0m)ofapool,spa,orfountain,or(b)outdoor,
connectpowertounittoareceptacleprotectedbyaGFCI.
• Thisoutdoorpowerunitshallbeconnectedtoa115/120voltcoveredGFCI
receptaclemarked“WetLocation”whileinuse.
• Mounttherain-tighttransformeratleastonefootabovegroundlevelwith
thewireterminalsfacingdown.NOTE:Donotenergizetransformeruntil
installationofsystemiscomplete.
 Directburialratedwireistobeburiedaminimumof6”(152mm)beneath
thesurfaceoftheground.
NOTE:IfadditionalDirectBurialwireisneeded,contactyourlocal
Kichler
®
landscapedistributor.
•8GAwirecanbepurchasedinlengthof250’(76M),15503-BK.
•10GAwirecanbepurchasedinlengthof250’(76M),15504-BK.
•12GAwirecanbepurchasedinlengthsof100’(30M),15501-BK;250’
(76M),15502-BK;500’(152M),15505-BK;and1000’(304M),15506-BK.
• FindingTransformerLoad:Lowvoltagesystemsrequiretheuseofa
transformertoreducestandard120-VOLTpowerfromyourhometo
12-VOLTS.Todeterminethetransformersizeyouwillneed,addupthe
wattagesofalllampsyouplantouse.Selectatransformerthatmatches
ascloselyaspossibletothetotallampwattage.Forexample,ifyou
have11xturesallratedat24.4watts,youwillneeda300watt
(VA)transformer(11x24.4=268.4watts).Generally,thetotallampload
shouldnotbelessthanone-thirdthetransformerswattagerating,nor
exceeditsmaximumwattagecapacity.Ifyourtotalwattageistoohigh,
eitherdividetheloadbetweentwotransformers,oruseamorepowerful
transformer.
ThisinstructionsheetcoverstheinstallationofthefollowingKichler®Transformers:15510AZT,15513AZT,15514AZT,15M200AZT,
15T200AZT,15TP200AZT.Readtheseinstructionscarefullybeforeinstallingthisunit.
INSTALLATION INSTRUCTIONS
1) Determinedesiredlocationformountingtransformer.NOTE:When
decidinglocationformountingconsiderationshouldbetakenforthe
requirementslistedabove.
2) Markpositionoftopportionofthekeyholeslotlocationattopoftransformer
andtheslotlocatedatbottom.
3) Ifmountingtoasolidsurfacesuchaswood,siding,etc;
A)Drill1/8”diameterpilotholesatpositionsmarkedinStep2.
B)Drivescrewsapproximatelyhalfwayintoholes.
Ifmountingtodrywall:
A)Drill1/4”diameterholesatpositionsmarkedinStep2.
B)Pushplasticanchorsintoholesandtapuntilush.
C)Drivescrewsapproximatelyhalf-wayintoplasticanchors.
4) Sliplargeportionofkeyholeoverheadoftopscrewandallowtransformer
toslidedown,makingsurebottomslotisbehindheadofbottomscrew.
5) Tightenscrewsuntiltransformerissecure.
6) Split12/2.10/2,or8/2cableapproximately3”,andstrip1/2”insulation
offeachwire.12/2.10/2,and8/2cableistheheavyblackcablewhich
allKichler
®
12-voltlowvoltagelightingxtureswillbeconnected.(Reference
abovefordescriptionandpartnumbers).
7) Pushonebarewireineachoftheholesonthebottomsideoftheterminal
blockandtightenscrewsonthefaceoftheterminalblockuntilwiresare
secure.
8) Plugpowersupplycordintostandard115/120voltreceptacle.
NOTE:Thepowersupplycordmustbepluggedintoaweathertight
receptacleequippedwithaGroundFaultInterrupter(GFCI).
DateIssued:8/14/09 IS15510-US
WARRANTY
We Warrant our transformers for ten years on aZt units and lifetime on stainless steel units against defects in material and Workmanship if it is prop-
erly installed and failed under normal operating conditions, provided it is returned to the point of purchase, Where it Will be repaired or, as it may be
determined, to replace the transformer.
INSTALL AND MAINTAIN TO MEET APPLICABLE CODES
COM.
12V
SETTING 3 POSITION SWITCH
Foroptimumlightoutputthevoltageatsocketshouldbe
between10and12volts.
LOW: Useiftotalwattageislessthanhalfofthetransformer
capacity(i.e.125wattsona300watttransformer),
cabledistancesarelessthan50feetorifthestarting
voltagecomingfromthehouseishigh.
OFF: Turnsoffthetransformerexcept
forthetimer.Thetimerwillstill
functionbutwillnotactivatesystem
duringpresettimes.
HI: Useifthetransformerisfully
loaded(maximumwattage
capacity),cabledistancesare
longorifthestartingvoltageis
lowcomingfromthehouse.
The“HI”or“LOW”position
switchwillactivateboth
thetimerandphotocell
(whenapplicable).
Push Either
LOW OR HI
THREE POSITION SWITCH
TERMINAL BLOCK
FIG.1
NOTE: TIMER INSTRUCTIONS LOCATED ON INSIDE OF
TRANSFORMER COvER.