Kichler Lighting 15510CBR User manual

Type
User manual

Kichler Lighting 15510CBR is a transformer designed for use with landscape lighting systems. It is rated for 120 volts and provides 12 volts of power to the lighting fixtures. The transformer has a three-position switch that allows the user to adjust the voltage output to suit the needs of the lighting system. The "LOW" setting is recommended for systems with a total wattage of less than half of the transformer's capacity, while the "HI" setting is recommended for systems with a total wattage that is close to the transformer's maximum capacity.

Kichler Lighting 15510CBR is a transformer designed for use with landscape lighting systems. It is rated for 120 volts and provides 12 volts of power to the lighting fixtures. The transformer has a three-position switch that allows the user to adjust the voltage output to suit the needs of the lighting system. The "LOW" setting is recommended for systems with a total wattage of less than half of the transformer's capacity, while the "HI" setting is recommended for systems with a total wattage that is close to the transformer's maximum capacity.

INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
OUTDOOR USE ONLY
DOM ETRE INSTALLE A L’EXTERIEUR
• Thispowersupplyisforusewithlandscapelightingsystemsonly.
• Donotsubmergetransformer.
• Thisdeviceisacceptedasacomponentofalandscapelightingsystem
wherethesuitabilityofthecombinationshallbedeterminedbyCSAor
localauthoritieshavingjurisdiction.TocomplywithCSArequirement,this
xtureshouldbeinstalledbyaqualiedelectrician.AuCanada.Pourêtre
enaccordavecIES1015CSA.Celuminairedoitêtreinstalléparun
électricienqualié.
• WARNING:Riskofelectricshock,useonlywithlowvoltagelandscape
xturesandaccessories.DOnotusewithswimmingpoolorspalighting
xtures.
• Donotconnecttwoormorepowersuppliesinparallel.
• Foroutdooruseonly.
• NationalElectricalCoderequiresthatwiringwhereconcealedorextended
throughabuildingwallmustbeenclosedinconduit.
• Transformershouldbemountedclosetopowersupply.Extensioncords
shouldnotbeusedwiththisunit.
• WARNING:(forPowerSupplyCordconnectedPOWERUNIT)
RISK OF ELECTRIC SHOCK.Installpowerunit5feet(1.5m)ormore
fromthepool,spa,orfountainwherethepowerunitisinstalled(a)
indoorwithin10feet(3.0m)ofapool,spa,orfountain,or(b)outdoor,
connectpowertounittoareceptacleprotectedbyaGFCI.
• Thisoutdoorpowerunitshallbeconnectedtoa115/120voltcoveredGFCI
receptaclemarked“WetLocation”whileinuse.
• Mounttherain-tighttransformeratleastonefootabovegroundlevelwith
thewireterminalsfacingdown.NOTE:Donotenergizetransformeruntil
installationofsystemiscomplete.
• The12GA,10GAand8GAcableisintendedforshallowburial.Bury
cableaminimumof6inches(152mm)belowthesurface.
NOTE:Ifmorecableisneeded,contactyourlocalKichler
®
Landscape
distributor.12GAcablecanbepurchasedinlengthsof75/22M(15500-BK),
100’/30M(15501BK),250’/76M(15502BK),500’/152(15505BK),and
1000’/304M(15506BK).10GAcableinlengthsof250’/76m(15504BK);
8GAcableinlengthsof250”/76M(15503-BK).
• FindingTransformerLoad:Lowvoltagesystemsrequiretheuseofa
transformertoreducestandard120-VOLTpowerfromyourhometo
12-VOLTS.Todeterminethetransformersizeyouwillneed,addupthe
wattagesofalllampsyouplantouse.Selectatransformerthatmatches
ascloselyaspossibletothetotallampwattage.Forexample,ifyou
have11xturesallratedat24.4watts,youwillneeda300watt
(VA)transformer(11x24.4=268.4watts).Generally,thetotallampload
shouldnotbelessthanone-thirdthetransformerswattagerating,nor
exceeditsmaximumwattagecapacity.Ifyourtotalwattageistoohigh,
eitherdividetheloadbetweentwotransformers,oruseamorepowerful
transformer.
ThisinstructionsheetcoverstheinstallationofthefollowingKichler®Transformers:15510AZT,15513AZT,15514AZT,15M200AZT,
15T200AZT,15TP200AZT.Readtheseinstructionscarefullybeforeinstallingthisunit.
INSTALLATION INSTRUCTIONS
1) Determinedesiredlocationformountingtransformer.NOTE:When
decidinglocationformountingconsiderationshouldbetakenforthe
requirementslistedabove.
2) Markpositionoftopportionofthekeyholeslotlocationattopoftransformer
andtheslotlocatedatbottom.
3) Ifmountingtoasolidsurfacesuchaswood,siding,etc;
A)Drill1/8”diameterpilotholesatpositionsmarkedinStep2.
B)Drivescrewsapproximatelyhalfwayintoholes.
Ifmountingtodrywall:
A)Drill1/4”diameterholesatpositionsmarkedinStep2.
B)Pushplasticanchorsintoholesandtapuntilush.
C)Drivescrewsapproximatelyhalf-wayintoplasticanchors.
4) Sliplargeportionofkeyholeoverheadoftopscrewandallowtransformer
toslidedown,makingsurebottomslotisbehindheadofbottomscrew.
5) Tightenscrewsuntiltransformerissecure.
6) Split12/2.10/2,or8/2cableapproximately3”,andstrip1/2”insulation
offeachwire.12/2.10/2,and8/2cableistheheavyblackcablewhich
allKichler
®
12-voltlowvoltagelightingxtureswillbeconnected.(Reference
abovefordescriptionandpartnumbers).
7) Pushonebarewireineachoftheholesonthebottomsideoftheterminal
blockandtightenscrewsonthefaceoftheterminalblockuntilwiresare
secure.
8) Plugpowersupplycordintostandard115/120voltreceptacle.
NOTE:Thepowersupplycordmustbepluggedintoaweathertight
receptacleequippedwithaGroundFaultInterrupter(GFCI).
INSTALL AND MAINTAIN TO MEET APPLICABLE CODES
COM.
12V
Setting 3 Position Switch
Foroptimumlightoutputthevoltageatsocketshouldbe
between10and12volts.
LOW: Useiftotalwattageislessthanhalfofthetransformer
capacity(i.e.125wattsona300watttransformer),
cabledistancesarelessthan50feetorifthestarting
voltagecomingfromthehouseishigh.
OFF: Turnsoffthetransformerexcept
forthetimer.Thetimerwillstill
functionbutwillnotactivatesystem
duringpresettimes.
HI: Useifthetransformerisfully
loaded(maximumwattage
capacity),cabledistancesare
longorifthestartingvoltageis
lowcomingfromthehouse.
The“HI”or“LOW”position
switchwillactivateboth
thetimerandphotocell
(whenapplicable).
Push Either
LOW OR HI
THREE POSITION SWITCH
TERMINAL BLOCK
FIG.1
NOTE: TIMER INSTRUCTIONS LOCATED ON INSIDE OF
TRANSFORMER COvER.
DateIssued:8/14/09 IS15510-CB
WARRANTY
We Warrant our transformers for ten years on aZt units and lifetime on stainless steel units against defects in material and Workmanship if it is prop-
erly installed and failed under normal operating conditions, provided it is returned to the point of purchase, Where it Will be repaired or, as it may be
determined, to replace the transformer.
  • Page 1 1

Kichler Lighting 15510CBR User manual

Type
User manual

Kichler Lighting 15510CBR is a transformer designed for use with landscape lighting systems. It is rated for 120 volts and provides 12 volts of power to the lighting fixtures. The transformer has a three-position switch that allows the user to adjust the voltage output to suit the needs of the lighting system. The "LOW" setting is recommended for systems with a total wattage of less than half of the transformer's capacity, while the "HI" setting is recommended for systems with a total wattage that is close to the transformer's maximum capacity.