Kichler Lighting 15515CBR User manual

Type
User manual

Kichler Lighting 15515CBR is a compact, versatile transformer designed for use with landscape lighting systems. Rated at 300-Watts, this transformer can handle a variety of low-voltage lighting fixtures and accessories. Its rugged construction and weather-resistant design make it suitable for outdoor use, while its compact size allows for easy mounting on walls or other surfaces. The transformer features a built-in circuit breaker for added safety and protection against overloads or short circuits.

Kichler Lighting 15515CBR is a compact, versatile transformer designed for use with landscape lighting systems. Rated at 300-Watts, this transformer can handle a variety of low-voltage lighting fixtures and accessories. Its rugged construction and weather-resistant design make it suitable for outdoor use, while its compact size allows for easy mounting on walls or other surfaces. The transformer features a built-in circuit breaker for added safety and protection against overloads or short circuits.

Date Issued: 4/11/08 IS-15515-ACB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
OUTDOOR USE ONLY
DOM ETRE INSTALLE A L’EXTERIEUR
WARRANTY
We Warrant our transformers for ten years on aZt units and lifetime on stainless steel units against defects in material and Workmanship if it is prop-
erly installed and failed under normal operating conditions, provided it is returned to the point of purchase, Where it Will be repaired or, as it may be
determined, to replace the transformer.
• Thispowersupplyisforusewithlandscapelightingsystemsonly.
• Donotsubmergetransformer.
• Thisdeviceisacceptedasacomponentofalandscapelightingsystem
wherethesuitabilityofthecombinationshallbedeterminedbyCSAor
localauthoritieshavingjurisdiction.TocomplywithCSArequirement,this
xtureshouldbeinstalledbyaqualiedelectrician.AuCanada.Pourêtre
enaccordavecIES1015CSA.Celuminairedoitêtreinstalléparun
électricienqualié.
• WARNING:Riskofelectricshock,useonlywithlowvoltagelandscape
xturesandaccessories.Alsosuitableforusewithsubmersible(fountain)
lightingxtures.DOnotusewithswimmingpoolorspalightingxtures.
• Donotconnecttwoormorepowersuppliesinparallel.
• Foroutdooruseonly.
• Foruseindwellingsonlywithprovidedconduitadapterplate.
• NationalElectricalCoderequiresthatwiringwhereconcealedorextended
throughabuildingwallmustbeenclosedinconduit.
• Transformershouldbemountedclosetopowersupply.Extensioncords
shouldnotbeusedwiththisunit.
• Thisoutdoorpowerunitshallbeconnectedtoa115/120voltcoveredGFCI
receptaclemarked“WetLocation”whileinuse.
• Mounttherain-tighttransformeratleastonefootabovegroundlevelwith
thewireterminalsfacingdown.NOTE:Donotenergizetransformeruntil
installationofsystemiscomplete.
• The12GA,10GAand8GAcableisintendedforshallowburial.Bury
cableaminimumof6inches(152mm)belowthesurface.
NOTE:Ifmorecableisneeded,contactyourlocalKichler
®
Landscape
distributor.12GAcablecanbepurchasedinlengthsof75/22M(15500-BK),
100’/30M(15501BK),250’/76M(15502BK),500’/152(15505BK),and
1000’/304M(15506BK).10GAcableinlengthsof250’/76m(15504BK);
8GAcableinlengthsof250”/76M(15503-BK).
• FindingTransformerLoad:Lowvoltagesystemsrequiretheuseofa
transformertoreducestandard120-VOLTpowerfromyourhometo
12-VOLTS.Todeterminethetransformersizeyouwillneed,addupthe
wattagesofalllampsyouplantouse.Selectatransformerthatmatches
ascloselyaspossibletothetotallampwattage.Forexample,ifyou
have11xturesallratedat24.4watts,youwillneeda300watt
(VA)transformer(11x24.4=268.4watts).Generally,thetotallampload
shouldnotbelessthanone-thirdthetransformerswattagerating,nor
exceeditsmaximumwattagecapacity.Ifyourtotalwattageistoohigh,
eitherdividetheloadbetweentwotransformers,oruseamorepowerful
transformer.
ThisinstructionsheetcoverstheinstallationofthefollowingKichler®Transformers:15515AZT,15M100AZT.Readtheseinstructionscarefully
beforeinstallingthisunit.
1) Determinedesiredlocationformountingtransformer.NOTE:When
decidinglocationformountingconsiderationshouldbetakenforthe
requirementslistedabove.
2) Markpositionoftopportionofthekeyholeslotlocationattopof
transformerandtheslotlocatedatbottom.
3) Ifmountingtoasolidsurfacesuchaswood,siding,etc;
 A) Drill1/8”diameterpilotholesatpositionsmarkedinStep2.
B) Drivescrewsapproximatelyhalfwayintoholes.
Ifmountingtodrywall:
A) Drill1/4”diameterholesatpositionsmarkedinStep2.
B) Pushplasticanchorsintoholesandtapuntilush.
C) Drivescrewsapproximatelyhalf-wayintoplasticanchors.
4) Sliplargeportionofkeyholeoverheadoftopscrewandallowtransformer
toslidedown,makingsurebottomslotisbehindheadofbottomscrew.
5) Tightenscrewsuntiltransformerissecure.
6) Split12/2.10/2,or8/2cableapproximately3”,andstrip1/2”insulation
offeachwire.12/2.10/2,and8/2cableistheheavyblackcablewhich
allKichler
®
12-voltlowvoltagelightingxtureswillbeconnected.
(Referenceabovefordescriptionandpartnumbers).
7) Pushonebarewireineachoftheholesonthebottomsideoftheterminal
blockandtightenscrewsonthefaceoftheterminalblockuntilwiresare
secure.
8) Plugpowersupplycordintostandard115/120voltreceptacle.NOTE:
Thepowersupplycordmustbepluggedintoaweathertightreceptacle
equippedwithaGroundFaultInterrupter(GFCI).
NOTE:Foroptimumlightoutputthevoltageatsocketshouldbebetween
10and12volts.
CIRCUIT BREAKER
(SECONDARYSIDE-12VOLTSIDE)
• Circuitbreakerwilltripifthereisashortoriftotal
wattageinstalledexceedsratedwattagepercircuit.
•Toresetbreaker,ipswitchto‘OFF’thenbackto
‘ON’position.
• Iftheunitcyclesonandoffwithoutregardtothe
timersetting,itshouldbecheckedbyaqualied
serviceperson.
THERMAL PROTECTION
(PRIMARYSIDE-120VOLTSIDE)
•Thisunitisequippedwithathermalprotectorand
willshutoffifoverheated.
INSTALLATION INSTRUCTIONS
• Cettesourced’alimentationestutiliséeuniquementaveclessystèmes
d’éclairagepaysagiste.
• Nepastropchargerletransformateur.
• Cedispositifestachetéentantquecomposantdesystèmed’éclairage
paysagiste.L’adaptabilitédescombinaisonsdoitêtredéterminéeparle
CSAinternationaloutouteautreautoritélocaleayantjuridiction.Pour
êtreconformeauxnormesCSAInternational,celuminairedoitêtre
installéparunélectricienqualié.
• AVERTISSEMENT :Risquedechocsélectriques.N’utiliserqu’avecdes
luminairesetaccessoiresàbassetension.Utiliserégalementavecdes
luminairessubmersibles(telsquedesfontaines).Nepasutiliseravec
desluminairespourpiscinesouspas.
• Nepasconnecterdeuxouplusieursalimentationsélectriquesenparallèle.
• Pourutilisationextérieureuniquement.
• LeCodenationaldel’électricitérequiertquelecâblagecachédansou
passéparunmurdoitêtreplacédansuneconduite.
• Letransformateurdoitêtreinstalléprèsdelasourced’alimentation.Ne
pasutiliserderallongeaveccetteunité.
• Cetteunitésoustensionàutiliseràl’extérieurdoitêtreconnectéeàune
prisecouvertede115/120Vprotégéeparundisjoncteurdefuiteàla
terreétiquetéeEmplacementhumidependantl’utilisation.
• Installerletransformateurétancheaumoins30cmau-dessusduniveau
dusolaveclesbornesdirigéesverslebas.REMARQUE :Nepasmettre
letransformateursoustensiontantquel’installationdusystèmen’est
pascomplètementterminée.
• Lescâblesde12,10et8GAsontdestisàuneinstallationsouterraine
peuprofonde.Enterrerlecâbleà152mmminimumsouslasurface.
REMARQUE :Siunblesupplémentaireestnécessaire,
contacterledistributeurlocaldesproduitspaysagistesKichler
®
Lecâble12GApeutêtreachetédansdeslongueursde22m(15500-BK),
30m(15501BK),76m(15502BK),152m(15505BK),et304m(15506BK).
Lecâble10GApeutêtreachetédansunelongueurde76m(15504-BK);
uncâblede8GAdelongueurde76m(15503-BK).
• Déterminerlachargedutransformateur:Lessystèmesàbassetension
requièrentl’emploid’untransformateurréduisantl’alimentationde
120Vdevotredomicileà12V.Pourdéterminerlapuissancedu
transformateurdontvousavezbesoin,ajouterlapuissanceen
wattsdetoutesleslampesquevousavezl’intentiond’utiliser.
Sélectionneruntransformateurcorrespondantlemieuxàlapuissance
enwattstotaledeslampes.Siparexemplevousavez11luminairesde
24,4wattschacun,vousavezbesoind’untransformateurde300watts
(VA)(11x24,4=268,4watts).Lachargetotaledeslampesne
devraitniêtreinférieureàuntiersdelapuissanceenwattsdu
transformateurniêtresupérieureàsapuissancemaximale.Sivotretotal
enwattsesttropéle,vouspouvezsoitrépartirlachargeentredeux
transformateurssoitutiliseruntransformateurpluspuissant.
Cetteched’instructionconcernel’installationdutransformateurKichler
®
suivant:15515AZT,15M100AZT.Prièredelireattentivementles
instructionsavantl’utilisationdel’unité.
1) Déterminerl’emplacementpourl’installationdutransformateur.
REMARQUE :Lorsdelasélectiondel’emplacementpourl’installation,
tenircomptedescritèresindiquésci-dessus.
2) Marquerlemplacementdelapartiesupérieuredel’encoche
situéesurenhautdutransformateur;marquerégalement
l’emplacementdel’encochesituéeenbasdutransformateur.
3) Encasdemontagesurunesurfacetellequelebois,parement,etc;
A)Percerdestrouspilotesd’undiamètrede1/8poauxem
placementsmarquésaucoursdel’étape2.
B) Enfoncerlesvisàenvironlamoitié.
Encasdemontagesurplacoplâtre:
A) Percerdestrousd’undiamètrede1/4poauxemplacements
marquésaucoursdel’étape2.
B) Enfoncerlesancresenplastiquedanslestrousettaper
jusqu’àalignement.
C) Enfoncerlesvisdanslesancresenplastiqueàlamoitié.
4) Passerlapartielapluslargedel’encocheentroudeserrurepar-dessus
lavissupérieureetpermettreautransformateurdeglisserverslebas
ens’assurantquel’encocheinférieureestderrièrelavisinférieure.
DISJONCTEUR
(CÔTÉSECONDAIRE-12V)
• Ledisjoncteursedéclencheencasdecourt-
circuitousilapuissanceenwattstotaledépasse
lapuissancenominaleparcircuit.
•Pourréenclencherledisjoncteur,passer
l’interrupteursurarrêtpuisànouveausurmarche.
• Sil’unitépassedemarcheàarrêtendépitdu
réglagedelaminuterie,demanderàuntechnicien
qualiédecontrôlerlesystème.
PROTECTION THERMIQUE
(CÔTÉPRIMAIRE-120V)
• Cetteunitéestmunied’unprotecteurthermique
ets’arrêteautomatiquementencasdesurchauffe.
INSTRUCTIONS D’INSTALLATION
Date Issued: 4/11/08 IS-15515-ACB
GARANTIE
pour les unités aZt, nous garantissons nos transformateurs pendant une période de dix (10) ans et pour les unités en acier inoxydable, nous offrons
une garantie à vie contre tout vice de fabrication et de main d’œuvre sous condition d’une installation appropriée et de problèmes survenant dans des
conditions normales d’utilisation. le transformateur doit être rapporté au lieu d’achat où il sera soit réparé soit remplacé selon l’évaluation des dom-
mages.
5) Resserrerlesvisjusqu’àcequeletransformateursoitbienxé.
6) Séparerlecâble12/2,10/2ou8/2àenviron7,5cmetdénuderle
revêtementà1,5cmdechacundesls.12/2.Lecâble10/2et8/2est
uncâblenoirlourdauquellesluminairesKichler®12Vàbassetension
serontconnectés.
(Sereporteràladescriptionetauxréférencesdepièceci-dessus).
7) Passerunlnudanschacundestroussurlapartieinférieuredubornier
et resserrerlesvissurlebornierjusqu’àcequeleslssoientxés.
8) Brancherlecâbled’alimentationdansuneprisestandardde115/120V.
REMARQUE :Lecâbled’alimentationdoitêtrebranchédansuneprise
étancheprotégéeparundisjoncteurdefuiteàlaterre.
REMARQUE:Pourobtenirunesortieoptimaledelalumière,latensionau
niveaudelaprisedoitêtreentre10et12volts.
  • Page 1 1
  • Page 2 2

Kichler Lighting 15515CBR User manual

Type
User manual

Kichler Lighting 15515CBR is a compact, versatile transformer designed for use with landscape lighting systems. Rated at 300-Watts, this transformer can handle a variety of low-voltage lighting fixtures and accessories. Its rugged construction and weather-resistant design make it suitable for outdoor use, while its compact size allows for easy mounting on walls or other surfaces. The transformer features a built-in circuit breaker for added safety and protection against overloads or short circuits.