Symantec NetBackup 5330 Hardware Installation Manual

Type
Hardware Installation Manual
Symantec NetBackup 5330
Hardware Installation Guide
21340138
Release 2.6.1
Documentation version: 2.6.1
PN: 21340138
Legal Notice
Copyright © 2015 Symantec Corporation. All rights reserved.
Symantec, the Symantec Logo, the Checkmark Logo, NetBackup, and Veritas are trademarks
or registered trademarks of Symantec Corporation or its affiliates in the U.S. and other
countries. Other names may be trademarks of their respective owners.
This Symantec product may contain third party software for which Symantec is required to
provide attribution to the third party (“Third Party Programs”). Some of the Third Party Programs
are available under open source or free software licenses. The License Agreement
accompanying the Software does not alter any rights or obligations you may have under those
open source or free software licenses. Please see the Third Party Legal Notice Appendix to
this Documentation or TPIP ReadMe File accompanying this Symantec product for more
information on the Third Party Programs.
The product described in this document is distributed under licenses restricting its use, copying,
distribution, and decompilation/reverse engineering. No part of this document may be
reproduced in any form by any means without prior written authorization of Symantec
Corporation and its licensors, if any.
THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED
CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR
NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH
DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. SYMANTEC CORPORATION SHALL
NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION
WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE
INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE
WITHOUT NOTICE.
The Licensed Software and Documentation are deemed to be commercial computer software
as defined in FAR 12.212 and subject to restricted rights as defined in FAR Section 52.227-19
"Commercial Computer Software - Restricted Rights" and DFARS 227.7202, et seq.
"Commercial Computer Software and Commercial Computer Software Documentation," as
applicable, and any successor regulations, whether delivered by Symantec as on premises
or hosted services. Any use, modification, reproduction release, performance, display or
disclosure of the Licensed Software and Documentation by the U.S. Government shall be
solely in accordance with the terms of this Agreement.
Symantec Corporation
350 Ellis Street
Mountain View, CA 94043
http://www.symantec.com
Printed in the United States of America.
10 9 8 7 6 5 4 3 2 1
Technical Support
Symantec Technical Support maintains support centers globally. Technical Support’s
primary role is to respond to specific queries about product features and functionality.
The Technical Support group also creates content for our online Knowledge Base.
The Technical Support group works collaboratively with the other functional areas
within Symantec to answer your questions in a timely fashion. For example, the
Technical Support group works with Product Engineering and Symantec Security
Response to provide alerting services and virus definition updates.
Symantec’s support offerings include the following:
A range of support options that give you the flexibility to select the right amount
of service for any size organization
Telephone and/or Web-based support that provides rapid response and
up-to-the-minute information
Upgrade assurance that delivers software upgrades
Global support purchased on a regional business hours or 24 hours a day, 7
days a week basis
Premium service offerings that include Account Management Services
For information about Symantec’s support offerings, you can visit our website at
the following URL:
www.symantec.com/business/support/
All support services will be delivered in accordance with your support agreement
and the then-current enterprise technical support policy.
Contacting Technical Support
Customers with a current support agreement may access Technical Support
information at the following URL:
www.symantec.com/business/support/
Before contacting Technical Support, make sure you have satisfied the system
requirements that are listed in your product documentation. Also, you should be at
the computer on which the problem occurred, in case it is necessary to replicate
the problem.
When you contact Technical Support, please have the following information
available:
Product release level
Hardware information
Available memory, disk space, and NIC information
Operating system
Version and patch level
Network topology
Router, gateway, and IP address information
Problem description:
Error messages and log files
Troubleshooting that was performed before contacting Symantec
Recent software configuration changes and network changes
Licensing and registration
If your Symantec product requires registration or a license key, access our technical
support Web page at the following URL:
www.symantec.com/business/support/
Customer service
Customer service information is available at the following URL:
www.symantec.com/business/support/
Customer Service is available to assist with non-technical questions, such as the
following types of issues:
Questions regarding product licensing or serialization
Product registration updates, such as address or name changes
General product information (features, language availability, local dealers)
Latest information about product updates and upgrades
Information about upgrade assurance and support contracts
Information about the Symantec Buying Programs
Advice about Symantec's technical support options
Nontechnical presales questions
Issues that are related to CD-ROMs, DVDs, or manuals
Support agreement resources
If you want to contact Symantec regarding an existing support agreement, please
contact the support agreement administration team for your region as follows:
[email protected]Asia-Pacific and Japan
[email protected]Europe, Middle-East, and Africa
[email protected]North America and Latin America
Technical Support ............................................................................................... 4
Chapter 1 Hardware overview ............................................................... 9
NetBackup 5330 appliance overview .................................................. 9
NetBackup 5330 appliance PCIe card configurations ........................... 10
NetBackup 5330 Appliance Ethernet port configurations ....................... 11
NetBackup 5330 storage shelves and disk drives ................................ 13
NetBackup 5330 cables and connectors ........................................... 14
Understanding the NetBackup 5330 hardware installation
sequence ............................................................................. 15
About IPMI configuration ................................................................ 17
Chapter 2 Hardware pre-installation requirements ....................... 19
Package contents for NetBackup 5330 systems .................................. 19
Customer-provided items for the NetBackup 5330 system
installation ............................................................................ 20
Unpacking a Primary Storage Shelf or an Expansion Storage
Shelf .................................................................................... 21
Unpacking a NetBackup 5330 appliance ........................................... 22
Prerequisites for IPMI configuration .................................................. 23
Chapter 3 Hardware installation procedures ................................... 25
Determining rack locations for NetBackup 5330 hardware ..................... 26
Installing a Primary Storage Shelf or an Expansion Storage Shelf ........... 27
Installing disk drives into a Primary Storage Shelf or an Expansion
Storage Shelf ........................................................................ 35
Installing the NetBackup 5330 appliance ........................................... 37
Installing the SFPs into the Fibre Channel (FC) ports ........................... 40
Removing SFP end caps ............................................................... 42
Connecting the NetBackup 5330 appliance to the Primary Storage
Shelf .................................................................................... 43
Connecting the Primary Storage Shelf to the Expansion Storage
Shelf .................................................................................... 45
Contents
Connecting the power cords to the NetBackup 5330 appliance and to
the storage shelves ................................................................. 46
Turning on the NetBackup 5330 appliance and the storage shelves
and verifying operation ............................................................ 48
Configuring the IPMI from the NetBackup Appliance Shell Menu ............ 56
Accessing and using the Symantec Remote Management
interface ............................................................................... 57
Appendix A Adding an Expansion Storage Shelf ................................ 60
Adding an Expansion shelf ............................................................. 60
Adding the disk space of an Expansion Storage Shelf from the
NetBackup Appliance Web Console ........................................... 64
Adding the disk space of an Expansion Storage Shelf from the
NetBackup Appliance Shell Menu .............................................. 65
Index .................................................................................................................... 68
8Contents
Hardware overview
This chapter includes the following topics:
NetBackup 5330 appliance overview
NetBackup 5330 appliance PCIe card configurations
NetBackup 5330 Appliance Ethernet port configurations
NetBackup 5330 storage shelves and disk drives
NetBackup 5330 cables and connectors
Understanding the NetBackup 5330 hardware installation sequence
About IPMI configuration
NetBackup 5330 appliance overview
The front panel of the appliance contains 12 disk drive slots. The slots are numbered
from zero (lower left slot) to 11 (upper right slot).
Disk drives in the NetBackup 5330 appliance include the following:
Eight 3TB SAS disks, which can be accessed from the NetBackup 5330
Appliance front panel. The disks are configured into two RAID 1 volumes, which
are labeled Volume 0 and Volume 1. The disks that are located in slot 0 and
slot 1 are configured as the RAID 1, Volume 0 device. This volume contains the
appliance operating system and the NetBackup application.
1
Chapter
The disks in slots 3 and 4 are configured as the RAID 1, Volume 1 device.
The appliance uses the disks that are located in slot 2 and slot 5 as hot-spare
disks. If a disk in either RAID volume experiences a hardware error, the appliance
automatically initiates a RAID rebuild operation. During the rebuild operation,
the appliance selects a hot-spare disk from slot 2 or slot 5, and then rebuilds
the RAID volume.
The disks in slots 6 and 7 are reserved for future use.
The rear panel of the appliance contains embedded ports and PCIe card slots.
The embedded ports include the following (with numbers associating the ports to
the items in the bulleted list):
Four 1Gb Ethernet ports (1)
One Video Graphics Array (VGA) port (2)
One serial port (for Symantec Technical Support use only) (3)
Three USB ports (4)
One Intelligent Platform Management Interface (IPMI) port for remote
management (5)
Two 10Gb Ethernet ports (6)
NetBackup 5330 appliance PCIe card configurations
The rear panel of the appliance contains six PCIe slots that are numbered 1 to 6.
Slots 1, 2, and 3 are located in PCIe Riser Assembly 2. Slots 4, 5, and 6 are located
in PCIe Riser Assembly 1.
10Hardware overview
NetBackup 5330 appliance PCIe card configurations
Riser 2
Riser 1
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
All PCIe slots are factory-populated. Each slot contains either a Fibre Channel (FC)
host bus adapter (HBA) card or an Ethernet network interface card. Slots 1 and 4
are reserved exclusively for attachment to the Primary Storage Shelf.
Table 1-1 describes the factory-available PCIe card configurations for the NetBackup
5330.
Table 1-1
Factory-available PCIe slot configurations for the NetBackup 5330
Slot 6Slot 5Slot 4Slot 3Slot 2Slot 1Model
10 Gb Ethernet10 Gb EthernetFC HBA10 Gb Ethernet10 Gb EthernetFC HBAA
8 Gb FC HBA10 Gb EthernetFC HBA10 Gb Ethernet10 Gb EthernetFC HBAB
8 Gb FC HBA8 Gb FC HBAFC HBA10 Gb Ethernet10 Gb EthernetFC HBAC
8 Gb FC HBA8 Gb FC HBAFC HBA10 Gb Ethernet8 Gb FC HBAFC HBAD
8 Gb FC HBA8 Gb FC HBAFC HBA8 Gb FC HBA8 Gb FC HBAFC HBAE
NetBackup 5330 Appliance Ethernet port
configurations
The rear panel of the NetBackup 5330 Appliance contains six PCIe slots, which
are populated according to five different supported configurations. The PCIe slot
configuration determines the number of Ethernet ports that are available on your
appliance.
Figure 1-1 shows where each Ethernet port is located on the rear panel of the
appliance.
11Hardware overview
NetBackup 5330 Appliance Ethernet port configurations
Figure 1-1
NetBackup 5330 Appliance Ethernet port locations
NetBackup 5330
eth0
eth1
eth2
eth3
eth4
eth5
eth7 eth6
eth9 eth8
eth13 eth12
eth11 eth10
PCIe-3
PCIe-2
PCIe-1
PCIe-6
PCIe-5
PCIe-4
All NetBackup 5330 Appliances include the following ports, which are built in along
the base of the rear panel:
1-Gb ports: eth0, eth1, eth2, and eth3
10-Gb ports: eth4 and eth5
Additional ports are located in the 10-Gb Ethernet network interface cards that are
installed in the PCIe slots. The number of ports depends on the PCIe slot
configuration of your appliance.
Table 1-2 shows the additional available Ethernet ports for each PCIe slot
configuration.
Table 1-2
NetBackup 5330 Appliance PCIe Ethernet port configurations
Slot and Ethernet port numberModel
Slot 2: eth8 (right), eth9 (left)
Slot 3: eth6 (right), eth7 (left)
Slot 5: eth10 (right), eth11 (left)
Slot 6: eth12 (right), eth13 (left)
A
(four 10-Gb Ethernet cards)
Slot 2: eth8 (right), eth9 (left)
Slot 3: eth6 (right), eth7 (left)
Slot 5: eth10 (right), eth11 (left)
B
(three 10-Gb Ethernet cards)
Slot 2: eth8 (right), eth9 (left)
Slot 3: eth6 (right), eth7 (left)
C
(two 10-Gb Ethernet cards)
Slot 3: eth6 (right), eth7 (left)D
(one 10-Gb Ethernet card)
N/AE
(no 10-Gb Ethernet cards)
12Hardware overview
NetBackup 5330 Appliance Ethernet port configurations
NetBackup 5330 storage shelves and disk drives
The NetBackup 5330 appliance supports two types of external disk drive storage
as follows:
Primary Storage Shelf
Expansion Storage Shelf
Each NetBackup 5330 appliance requires one Primary Storage Shelf. The Expansion
Storage Shelf provides additional storage capacity.
Due to weight considerations, the storage shelves should be installed at or as close
to the bottom of the rack as is possible. When the storage shelves and an appliance
have been installed, the Fibre Channel (FC), SAS, and power cables are connected
between the units. The FC cables connect the appliance to the Primary Storage
Shelf. The SAS cables connect a Primary Storage Shelf to an Expansion Storage
Shelf. When all connections are completed, turn on the storage shelves and the
appliance to initialize and synchronize the units.
To help reduce the weight of the units during installation, the disk drives are not
factory-installed into the storage shelves. The disks are shipped in separate
packages, with ten disks in each package. Six packages are required to fully
populate each storage shelf. Each individual disk is wrapped in an anti-static bag.
Disks must be installed into the storage shelves by opening the storage shelf drawers
and inserting each disk into a slot. Best practices recommend that you start at the
bottom drawer and move up. Insert the disks into one drawer at a time.
The drawers for each shelf are numbered from 1 to 5 starting at the top of the shelf.
The disk slots in each drawer are numbered from 1 to 12 starting at the left side of
the drawer.
13Hardware overview
NetBackup 5330 storage shelves and disk drives
Three LEDs on the front of the drawer provide information about each column of
three slots.
See “Installing disk drives into a Primary Storage Shelf or an Expansion Storage
Shelf on page 35.
NetBackup 5330 cables and connectors
The following types of cables and connectors are provided:
Power cords that connect each device to AC power distribution units (PDUs) in
the rack.
Fiber Channel (FC) cables that connect the appliance to the Primary Storage
Shelf.
SAS cables that connect the Primary Storage Shelf to the Expansion Storage
Shelf.
Small Form-factor Pluggable (SFP) modules for FC and 10Gb ports.
SFPs are factory-installed in the cards in the PCIe risers.
14Hardware overview
NetBackup 5330 cables and connectors
Two SFPs are provided for use with the 10Gb ports on the rear panel of the
appliance.
In addition, you may need to obtain the following types of cables depending on the
I/O configuration of your appliance:
Ethernet cables between the 1Gb Ethernet and the 10Gb Ethernet ports on the
appliance rear panel and your network.
Ethernet cable between the Intelligent Program Management Interface (IPMI)
port on the appliance rear panel and your network for remote access to the
appliance.
Additional FC cables between the 8Gb FC HBA ports on the appliance rear
panel and your network for connection to tape or other devices.
Understanding the NetBackup 5330 hardware
installation sequence
To allow for easier installation and convenience for cabling between units, the
installation of the appliance and the storage shelves must be performed in a specific
sequence.
The recommended installation sequence is as follows:
Storage shelves
Expansion Storage Shelf - install in the lowest available 4RU rack space.
Primary Storage Shelf - install in the next available 4RU rack space above
the Expansion Storage Shelf.
The storage shelves are the heaviest units. They are physically very similar
and both use the same rail type for mounting. For easier installation, do not
install the disk drives until after the units are installed into the rack.
The estimated time to install one storage shelf is about 2.5 hours.
NetBackup 5330 appliance - install in the next available 2RU rack space above
the Primary Storage Shelf.
The estimated time to install one appliance is about 1.25 hours.
Table 1-3 describes the installation steps and includes a link to the specific procedure
for that step.
15Hardware overview
Understanding the NetBackup 5330 hardware installation sequence
Table 1-3
Storage shelf and appliance hardware installation sequence
DescriptionStep
Determine the rack location for the storage shelves and the appliance.
See “Determining rack locations for NetBackup 5330 hardware” on page 26.
1
Unpack the Expansion Storage Shelf and the Primary Storage Shelf.
See “Unpacking a Primary Storage Shelf or an Expansion Storage Shelf”
on page 21.
2
Mount the storage shelf rails in the rack and install the storage shelf.
Note: The following topic can be used for both the Expansion Storage Shelf and
the Primary Storage Shelf.
See “Installing a Primary Storage Shelf or an Expansion Storage Shelf” on page 27.
3
Unpack the NetBackup 5330 Appliance.
See “Unpacking a NetBackup 5330 appliance” on page 22.
4
Mount the appliance rails in the rack and install the appliance.
See “Installing the NetBackup 5330 appliance” on page 37.
5
Install the disk drives into each storage shelf.
See “Installing disk drives into a Primary Storage Shelf or an Expansion Storage
Shelf on page 35.
6
For the primary storage shelf only: Connect the four fiber channel cables between
the primary storage shelf and the appliance.
See “Connecting the NetBackup 5330 appliance to the Primary Storage Shelf”
on page 43.
7
For the Expansion storage shelf only: Connect the four SAS cables between the
Expansion shelf and the primary shelf.
See “Connecting the Primary Storage Shelf to the Expansion Storage Shelf”
on page 45.
8
Connect the Power Distribution Unit (PDU) cords between the appliance and the
power distribution outlets in the rack
See “Connecting the power cords to the NetBackup 5330 appliance and to the
storage shelves” on page 46.
9
16Hardware overview
Understanding the NetBackup 5330 hardware installation sequence
Table 1-3
Storage shelf and appliance hardware installation sequence
(continued)
DescriptionStep
Connect the Power Distribution Unit (PDU) cords between each storage shelf and
the power distribution outlets in the rack.
See “Connecting the power cords to the NetBackup 5330 appliance and to the
storage shelves” on page 46.
10
Turn on power to the storage shelves and the appliance.
See “Turning on the NetBackup 5330 appliance and the storage shelves and
verifying operation” on page 48.
11
Configure IPMI and the NIC1 (eth0) interface from the NetBackup Appliance Shell
Menu.
See “Configuring the IPMI from the NetBackup Appliance Shell Menu” on page 56.
12.
About IPMI configuration
The Intelligent Platform Management Interface (or IPMI) provides management and
monitoring capabilities independently of the host system's CPU, firmware, and
operating system. You can configure the IPMI sub-system for your appliances. The
IPMI sub-system can be connected by using the remote management port, located
on the rear panel of the appliance.
The following figure shows the remote management port (or the IPMI port) on the
rear panel of a 5330 appliance:
IPMI
port
The IPMI is beneficial after an unexpected power outage shuts down the connected
system. In case the appliance is not accessible after the power is restored, you can
use a laptop or desktop computer to access the appliance remotely by using a
network connection to the hardware rather than to an operating system or login
17Hardware overview
About IPMI configuration
shell. This enables you to control and monitor the appliance even if it is powered
down, unresponsive, or without any operating system.
The following diagram illustrates how IPMI works:
How does IPMI work?
When an appliance is powered
off or cannot be accessed
using the network interface
Symantec NetBackup
Appliance
Remote
Management
Port
Out of band management using IPMI
Remote Management Console
Some of the main uses of IPMI are the following:
Manage an appliance that is powered off or unresponsive. Using the IPMI, you
can power on, power off, or restart the appliance from a remote location.
Provides out-of-band management and help manage situations where local
physical access to the appliance is not possible or preferred like branch offices
and remote data center.
In case the appliance is not accessible using regular network interfaces, you
can access the NetBackup Appliance Shell Menu remotely using IPMI.
Note: Only the NetBackup Appliance Shell Menu can be accessed by using the
IPMI interface. The NetBackup Appliance Web Console cannot be accessed
by using the IPMI interface.
Reimage the appliance from the IPMI interface by using ISO redirection.
Monitor hardware health of the appliance from a remote location.
Avoid messy cabling and hardware like keyboard, monitor, and mouse (KVM)
solutions.
18Hardware overview
About IPMI configuration
Hardware pre-installation
requirements
This chapter includes the following topics:
Package contents for NetBackup 5330 systems
Customer-provided items for the NetBackup 5330 system installation
Unpacking a Primary Storage Shelf or an Expansion Storage Shelf
Unpacking a NetBackup 5330 appliance
Prerequisites for IPMI configuration
Package contents for NetBackup 5330 systems
The appliance and each storage shelf are shipped in separate containers. Each
container includes other boxes and contents. The disk drives for the storage shelves
are shipped in additional boxes.
Table 2-1 describes the contents of the containers for a NetBackup 5330 system.
2
Chapter
Table 2-1
NetBackup 5330 system container contents
ContentsContainer
Safety manual
Left and right rack rails
Appliance
Appliance bezel
Two power cords
Shrink-wrapped, yellow, portfolio containing the following:
USB sticks with factory reset files.
NetBackup 5330 Appliance Hardware Installation Guide
NetBackup 5330 Appliance Initial Configuration Guide
Warranty and license information
5330 appliance
Left and right rack rails with mounting hardware
Shelf bezel
Primary Storage Shelf
Four Fiber Channel cables
Four SFPs
Two power cords
Primary Storage
Shelf
Left and right rack rails with mounting hardware
Shelf bezel
Expansion Storage Shelf
Two power cords
Four SAS cables
Expansion Storage
Shelf
Customer-provided items for the NetBackup 5330
system installation
The following describes the necessary personnel and equipment that are needed
at the installation site:
At least two people or a mechanical lift to move the storage shelves.
A keyboard and a monitor to connect to the appliance.
Ethernet and Fiber Channel (FC) cables to connect the appliance to your
corporate network.
A 19-inch rack with dual Power Distribution Units (PDUs).
220VAC power supply for the Primary Storage Shelf and the Expansion
Storage Shelf
20Hardware pre-installation requirements
Customer-provided items for the NetBackup 5330 system installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69

Symantec NetBackup 5330 Hardware Installation Manual

Type
Hardware Installation Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI