Application sheet
BasicGrip
Carpet / tiles / parquet / laminate / synthetics
Cement-screed
1
2
3
4
5
1 Carpet / tiles / parquet
2 Cement-screed 65 mm
3 FH composite pipe (16 mm)
4 BasicGrip panel 11mm insulation 11 mm
5 Insulation WLG 040 70 mm
6 Basic perimeter insulation
Floor nish NA mm Carpet / tiles / parquet / laminate / synthetics
Technical Data
Construction height 146 mm Height excluding oor nish
Weight ~ 140 kg / m² Weight excluding oor nish
Thermal resistance R 2,06 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled.
Thermal transmission coecient U 0,45 W / m²K If the architectural design species better thermal insulation, this
must be taken into account.
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
The screed thicknesses must be adjusted in case of higher design load or point load
values.
Observe all installation instructions and manufacturer’s instructions.
Additional insulation
Insulation: 70 mm EPS 040 DEO
Construction
According to EnEV, EN 1264, DIN 4109, 1055 and 18560
Construction number 171
Technical Data Floors/ceilings exposed to outside air
6
© Danfoss 11/2008
VA.CT.U1.02