Optimus RX-3500 SERIES User manual

Type
User manual

This manual is also suitable for

—— ——
Restmoment digital conference system
RX-3500 SERIES
Installation operation
RESTMOMENT ELECTRONIC CO.,LTD
www.restmoment.com
-1-
CONTENTS
RESTMOMENT DIGITAL CONFERENCE SYSTEM...............................................................................................0
RX-3500 SERIES..............................................................................................................................................................0
PART 1 SAFETY OPERATION ......................................................................................................................2
1.1 SAFETY OPERATION.............................................................................................................................................2
PART 2 SYSTEM CONNECTIO2.1...............................................................................................................................3
SYSTEM CONNECTION DIAGRAM...........................................................................................................................3
PART 3 SYSTEM PORTS AND KEYS..........................................................................................................................4
3.1 PORTS AND KEYS ........................................................................................................................................................4
3.1.1 RX-3500 series controller...................................................................................................................................4
3.1.1.1 RX-3500 front panel ports...............................................................................................................................................4
3.1.1.2 RX-3500 back panel ........................................................................................................................................................4
3.1.2 RX-3500 serial unit.............................................................................................................................................5
3.1.2.1 RX-3500..........................................................................................................................................................................5
3.1.2.2 RX-3500..........................................................................................................................................................................7
4.1 RX-3500 HARDWARE CONNECTION............................................................................................................................7
4.1.1 system controller and unit connection.............................................................................................................7
4.1.2 unit and unit connection. .................................................................................................................................8
4.1.3 system controller and speed done camera connection.....................................................................................8
4.2 SYSTEM CONTROLLER ADJUSTMENT...........................................................................................................................9
4.2.1 System controller interface and key:................................................................................................................9
4.2.2 main menu instruction:..................................................................................................................................10
4.2.3 new system adjustment steps; ........................................................................................................................10
4.2.3.1 Adjustment steps:........................................................................................................................................................10
4.2.3.3 setup work mode in controller .......................................................................................................................................14
4.2.3.5 setup video trace in controller.....................................................................................................................................15
4.2.3.6 setup system function in controller................................................................................................................................18
4.3 RX-MBVS SOFTWARE SETUP AND ADJUSTMENT......................................................................................................19
4.3.1 RX-MBVS RX-MBVS function ....................................................................................................................21
4.3.1.1 System setting................................................................................................................................................................23
4.3.1.2 Attendance file............................................................................................................................................................24
4.3.1.3 genda management .....................................................................................................................................................24
4.3.1.4 screen info...................................................................................................................................................................24
4.3.1.5 ideo tracing .................................................................................................................................................................25
4.3.1.6 onference video...........................................................................................................................................................26
4.3.1.7 Help...............................................................................................................................................................................26
4.3.1.8 Back...............................................................................................................................................................................26
www.restmoment.com
-2-
PART 5 FAQ....................................................................................................................................................................27
Part 1 SAFETY OPERATION
1.1 SAFETY OPERATION
Thanks to the use of RESTMOMENT conference system. Please read
this operation carefully before you use the equipment, and operate it as request.
1Please confirm the power supply system is under the requirement of the equipment
normal level.
2Please protect cable not be treaded and pressed, special joint.
3When setup system, should insure the connection of ground is well, don’t use 2 Pin
plug. Input voltage AC 100240V50Hz
4Resist 1.5M free falling body industrial level aseismatic standard.
5Please notice the system environment, not too hot or too cold, keep the suitable
temperature
6Equipment power supply will get hot when it work, so should keep work
environmental aeration, avoid hot temperature.
7 Please turn off main supply in wet weather or free time.
8Please pull out power supply before below operation.
Apart or rerun setup any spare parts
Reload any plug or other conncetions.
9Equipment with AC 100240V components, please don’t open machine cover.
Not professional, please don’t maintain equipment privately.
10All kinds of chemical was forbidden to contact any part of the appliance
11Before turn on controller power, please comb-out system connection, and
controller setup.
www.restmoment.com
-3-
PART 2 SYSTEM CONNECTIO2.1
system connection diagram
www.restmoment.com
-4-
PART 3 system ports and keys
3.1 ports and keys
3.1.1 RX-3500 series controller
3.1.1.1 RX-3500 front panel ports
1Mounting hole for 19 inch stand
2Front panel
3LCD screen, adjust brightness and contrast.
45-dimensional direction operate、control key
5Switch, with electrifying indicator
6Mounting hole for 19 inch stand
3.1.1.2 RX-3500 back panel
1Power port: Input AC 100~240V, 4A 50-60Hz
2RS232 interface (PC): Computer control system interface.
www.restmoment.com
-5-
3RS232 interface(CCU): Central control system interface.
4USB interface ( CONTRUL IN): Function extension interface. Reserve for function extension
5~84 PCS 6P DIN digital interfaces ( DRAGOMAN ): 4 channels conference unit output. Can
connect all digital all conference unit equipment in same series, and single function equipment.
96P DIN digital interface ( EXTEND ): Extension main unit digital interface, connect to EXTEND
IN port of extension main unit.
10RCA Audio interface ( LINK OUT ): Audio output interface of System controller, can connect
peripheral amplifying system or recording system
11RCA Audio interface ( LINK IN ): Input interface of the third sound source
12RCA Audio interface ( LINK OUT ):Audio output interface of System controller, can connect
peripheral amplifying system or recording system
13RCA Audio interface ( LINK IN ): Input interface of the third sound source
146.3mm MIC input socket
15Cannon balance interface MIC, connect MIC
16RS 485 interface: Connect to camera. Connect positive and negative electrode correctly.
17~182 USB interfaces ( CONTROL OUT ): Function extension interface. Reserve for function
extension
3.1.2 RX-3500 serial unit
3.1.2.1 RX-3500
RX-C/D 3500 unit front panel schematic diagram
1. Unit LCD display
* Display related information
2. MENU multi-complex function key
*Function selection key. Used for simultaneous
interpretation receiving channel selection and
unit function setting enter and exit
*Used as digital key 1/6 when input unit location
3. Multi-complex function
www.restmoment.com
-6-
* Left key. Select function menu of the unit.
Cursor move key
*Used as digital key 2/7 when input unit location
Utilizada para decrementar volumen.
4PRIOR Chairman function control key, essage rapid key
* Conference Chairman operate chairman ontrol right
*Set MIC management mode.
Utilizada para incrementar volumen.
5. Multi-complex function
*Right key. Select function menu of the unit. Cursor move key
*Used as digital key 3/8 when input unit location
6. Multi-complex function
* MIC floor “ON/OFF” key
*Switching key. Inputting mobile cursor on location to function key MIC ON/OFF key indicator
when input unit location
7. Multi-complex function
*Act as ENTER key when set unit function or parameter
*Used as digital key 4/9 when input unit location
8. Multi-complex function
* message rapid key
*Used as digital key 5/0 when input unit location
9. Loudspeaker inside
10. Unit earphone jack
*Monitor the language of corresponding channel
*Listen to the language of corresponding channel
11. Chairman / Delegate unit IC card
www.restmoment.com
-7-
Chairman / Delegate unit sign-in and other function
12. Gooseneck microphone: With red ring to indicate floor
13. Red indicating ring: Indicate the microphone is working when the light is on.
14. Microphone: High Sensitivity, Cardioid, Electret condenser microphone
3.1.2.2 RX-3500
RX-C/D 3500 unit back panel schematic diagram
1. Screw hole
2.Shake proof and corrosion
proof rubber pad
3.IN 6 pin socket
4.Wire chase
5.OUT 6 pin socket
setup and function RX-MBVS
RX-MBVS is RESTMOMENT digital conference system RX-3500 serial software.
When it work with conference system, could manage MIC, and have sign-invote
video function. It can’t work without hardwork.
4.1 RX-3500 hardware connection
4.1.1 system controller and unit connection.
system controller and unit connection use 6P cable. system controller Output port connect the
first unit IN port. Every Output could connect 20 units. For avoiding interference, system
controller cable should have special duct. Standard cable length is 10 M, could order more long
cable as actually.
Notice:
www.restmoment.com
-8-
Please don’t change the connection between unit and system controller. It could
lead Anomalies.
4.1.2 unit and unit connection.
Hand-in-Hand connection. Unit with 6P-2M cable. The first unit Out port to the
second unit In port. The second unit Out port to the third unit In port. Followed
by analogy.
4.1.3 system controller and speed done camera connection.
speed done camera, have ceiling and wall-mounted mode. Camera high less than 2-3 M. The
distance between camera and rostrum is 10-15M. Camera need independence power supply,
should be setup with 100240V socket
System controller have 8 video input, 4 video output, could handle 8 PCS
camera.
Camera double Pin cable connect corresponding video port of system
controller.
For instance, the camera address No is 1, video info should connect the
first input.
Camera communication adopt RX-485 transmit way. For insure transmit
distance and anti-jamming, suggest use twisted-pair, from camera RS-485 +/-
port to system controller RS-485 +/- port.
Camera and keyboard connection as above.
Notice:
Please don’t mess camera +/-, otherwise, will lead unusual situation.
Please don’t use software and keyboard for camera simultaneous. It will
lead camera out off control.
www.restmoment.com
-9-
4.2 system controller adjustment
Insure system controller and unit connection, then turn on system controller power, it
will check automatically.
4.2.1 System controller interface and key:
ADCS System controller interface
ADCS System controller display interface ADCS System controller operate interface
Four-dimensional keyup Four-dimensional keydown
Four-dimensional keyleft Four-dimensional keyright
MENUCONFIRM
system controller standby interface:
standby interface system main menu
www.restmoment.com
-10-
enter main menu
Press MENUCONFIRM, enter system main menu. See photo
4.2.2 main menu instruction:
Conference event: edit conference event and check agenda result.
Work mode: setup unit work mode.
Speaker set: setup output and input volume.
Video-tracing: setup panorama/unit video tracing.
System setup: unit NO、chairman unit、LED setup、language、IC card and speech count
down time.
Help: system version No.
Exit: Exit system menu.
4.2.3 new system adjustment steps;
4.2.3.1 Adjustment steps:
Si el sistema viene reseteado de fábrica y no se utilizan tarjetas IC, tiene que deshabilitarse esta opción.
MENU Æ SYSTEM SETTING Æ OTHER SETTING Æ IC CARD OFF
1)Check connection as system connection diagram, then turn on system controller. System
check units automatically and show equipment list. Please confirm the equipment list is the same as
actually quantity. After than, system enter standby interface.
www.restmoment.com
-11-
Notice: in this list, the chairman unit is executive chairman.
2) setup unit quantity and ID No.
Press , enter system main unit, select system setup, then select to edit ID No,
press again. Move cursor to “start” key, press at previous.
El 0050 es el número máximo de unidades del sistema actual. Debe ponerse el nº real.
units prompt as below photo:
When press unit’s “MIC” key, system will send this unit one ID No, as below photo
When all units have ID No, close this operation.
Notice:
System need re-edit ID No in below instance
1Setup new system
2Move、change、add or delete units
3unit prompt no ID No.
Unit prompt no ID No as below photo,
www.restmoment.com
-12-
At this moment, we could edit ID No for this unit. Enter “Edit ID No” , select right key, edit one
ID No, as below photo:
Setup ID No, move cursor to “start”, press . At previous, press unit’s “MIC” key.
4.2.3.2 vote in controller
Para poder realizar una votación es necesario identificar previamente las unidades que van a poder votar.
Esto se hace mediante la opción Sign in.
Before vote, should setup units quantity. Vote people quantity should be the same as setup
quantity ( for instance, we setup units quantity as 50.
Press , enter system main menu, then enter Meeting event setup interface, see below
photo
menu include:
New sign in: setup sign in conference event, enter sign in interface, press “start”, see below
photo:
Ought seria el número de unidades totales. Al pulsar start se activará una cuenta atrás de 30s para que todas
las unidades activas puedan darse de alta en la votación pulsando su propia tecla mic. Para finalizar el
proceso sin acabar la cuenta atrás debe pulsarse la tecla menú, que la dejará con solo 2s de margen.
www.restmoment.com
-13-
New vote: setup vote conference event, enter vote interface, press “start”. More than 10 vote
modes could be selected. see below photo.
Al pulsar start se activará una cuenta atrás de 30s para que todas las unidades puedan votar. Para finalizar el
proceso sin acabar la cuenta atrás debe pulsarse la tecla menú, que la dejará con solo 2s de margen.
New poll: setup poll conference event, enter poll interface, press “start”. Many poll modes
could be selected, for instance, 5 elect 4, see below photo
Result Display: enter result display interface, could see vote、sign in and poll
result.
see below photo
result display
sign in result inquiry
vote result inquiry
www.restmoment.com
-14-
poll result inquiry
Meeting Setting: setup count-down time and count rule, see below photo
Pre-> Si, Agt->-No, Abs-> Abstensión
Back: back to previous menu
4.2.3.3 setup work mode in controller
Press enter system main menu and Mode setting interface, see below photo:
this menu include:
Limit mote: set the number of delegates permitted to speak at the same time. see below photo
Al limitar a una unidad abierta pasaría a funcionar como modo FIFO.
FIFO mode :microphone key control with override of the active microphones. see below
photo.
Este modo funciona realmente como LIFO.
www.restmoment.com
-15-
Apply mode: microphone key with request –to-speak registration (AUTO). see below photo
Voice mode: voice-activated microphones with selectable threshold. see below photo
4.2.3.4 setup volume in controller
Press enter system main menu and volume setup interface, see below photo:
This menu include
Input volume: could adjust volume as meeting room request.
Output volume: could adjust volume as meeting room request.
4.2.3.5 setup video trace in controller
www.restmoment.com
-16-
Press enter system main menu and volume setup interface, see below photo:
This menu include:
Camera parameter: setup baud rate、protocol、save No. See below photo
Could setup 8 cameras with difference protocol and baud rate.
Operation option: setup scene、save No. See below photo
Setup scene
1Unit:001 option, select scene 0001, press .
Notice: left and right key adjust camera panorama. One camera could have 2 panorama.
2Move cursor to , adjust camera panorama position.
Notice: “up down、left right” is for camera moving speed.
3Adjust Focus、Aperture、Zoom、up down、left right.
Notice: “up down、left right” is for camera moving speed.
4Move cursor to “ camera 01”, select correspondence panorama.
www.restmoment.com
-17-
Notice: Camera address No will change automatically when adjust panorama position.
5Move cursor to save NO:001, select one to save camera position.
6Move cursor to save “ panorama 001” as preset point
Notice: Save No can’t repeat. back to previous menu, RST meat clear all save No.
setup unit tracing steps: ( see below photo)
1Select “unit 0001”, press .
2Move cursor to , preset unit position
3up down、left right” is for camera moving speed.
4Move cursor to “ camera 01”, select correspondence unit.
5Move cursor to save NO:001, select one to save camera position.
6Move cursor to save “ unit 001” as preset point
Notice: Save No can’t repeat. back to previous menu, RST meat clear all save No.
Video matrix: setup controller 4 matrix video output. See below photo
Out put 1-4 meant video output; 1-8 meant 8 cameras.
For instance, setup output 1 with 1-3 cameras video signal, as below steps:
1Move cursor to “output1”, press , move cursor to 1-3, press , grounding is
black.
2Move cursor to save it.
Turn off video:
www.restmoment.com
-18-
As above photo: preset camera 1 to trace unit No1-5, setup 4 panorama.
“camera 1 corresponding MIC” setup unit 1-5.
3 options
“previous unit”
“ No action”
“ID 0001”
“ turn off all to panorama” camera switch to panorama when all units are off.
1~4meant panorama 1~4. black grounding.
“time” meant camera 1 panorama switch time.
“cameras switch” panorama switch have two types.
“gradation” select panorama gradation according to port.
“dependence” select panorama gradation according to camera No.
for instance
Port 1 have camera 1、camera 2、camera 3, all cameras have 4 panoramic positions.
“gradation”, panoramic switch gradation: 1a1b1c1d2a2b2c2d3a3b3c3d
4a4b4c4d
“dependence”, panoramic switch gradation: 1a2a3a4a1b2b3b4b1c2c3c
4c1d2d3d4d
4.2.3.6 setup system function in controller
Press , enter system main menu, then enter system setup interface, see below photo
www.restmoment.com
-19-
This menu include:
Edit No: setup total human quantity and unit No.
Status setup: setup executive chairman unit.
One system only have one executive chairman unit. ID item display all common chairman unit.
Screen setup: setup LED brightness and contrast. See below photo:
Menu language setup: setup controller language. See below photo:
System have Chinese and English. Could order other languages.
Other setup: IC card sign-in function, speech count down time. As below photo:
Back: back to previous menu.
4.3 RX-MBVS software setup and adjustment.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29

Optimus RX-3500 SERIES User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI