FURNACE APPLICATION 3:
Instrucons for 90% AFUE, Upow
Models: P (1,2,9) UD, P (A,B,K) NU, XNU
1. Turnoallgasandelectricsupply
totheequipmentbeingserviced.
2. Removetheburnercompartment
accessdoor.
3. Removeburnerboxcoverand
savethescrewsforre-assembly.
4. Disconnectthewiringfromthehotsurfaceignitorattheplug
connecon.
5. Carefullyremovetheoldbracketandignitorsavingthescrewfor
re-assembly.
6. Ifbothholesarenotpresentonthefurnacepaneltoacceptthe
newbracket,drilla5/32”holeusingthenewignitorbracketfor
alignment.
7. Aachthenewignitortothenewbracket(10-567)withthehex
headscrewprovided(30-123).
8. Carefullyinstallthenewbracketandignitorusingthescrewssaved
fromtheoldbracketremoval.
9.Theclearancebetweenthemetalshieldoftheignitorandthe
carryovertubeshouldbebetween0”and1/8”.
10.Reconnecttheignitor.
11. Replacetheburnerboxcover.
12. Restorethegasandelectricalsupplytotheunit.
13. Setroomthermostatforheatandcyclethesystem.
14. Replaceburnercompartmentaccessdoor.
FURNACE APPLICATION 4:
Instrucons for 90% AFUE, Downow
Models: P (1,2) CD, P (A,B) XND
1. Turnoallgasandelectricsupply
totheequipmentbeingserviced.
2. Removetheburnercompartment
accessdoor.
3. Removeburnerboxcoverandsavethescrewsforre-assembly.
4. Disconnectthewiringfromthehotsurfaceignitorattheplug
connecon.
5. Carefullyremovetheoldbracketandignitorsavingthescrew
forre-assembly.
6. Ifbothholesarenotpresentonthefurnacepaneltoaccept
thenewbracket,levelthenewmounngbrackethorizontallyand
drilla7/64”hole.
7. Aachthenewignitortothenewbracket(10-570)withthehex
headscrewprovided(30-123).
8. Carefullyinstallthenewbracketandignitorusingthescrewsfrom
theoldbracket.
9. Theclearancebetweenthemetalshieldoftheignitorandthe
carryovertubeshouldbebetween0”and1/8”.
10.Reconnecttheignitor.
11. Reinstalltheburnerboxcover.
12. Restorethegasandelectricalsupplytotheunit.
13. Setroomthermostatforheatandcyclethesystem.
14. Replaceburnercompartmentaccessdoor.
FURNACE APPLICATION 5:
Instrucons for 90% AFUE, Upow
Models: P2UR, PBLU, DGU Style A
1. Turnoallgasandelectricsupply
totheequipmentbeingserviced.
2. Removetheburnercompartment
accessdoor.
3. Removeburnerboxcoverandsavethescrewsforre-assembly.
4. Disconnectthewiringfromthehotsurfaceignitorattheplug
connecon.
5. Carefullyremovetheoldbracketandignitorsavingthescrewsand
gasketforre-assembly.
6. Carefullyinstallthenewbracket(10-566)andignitorontheburner
boxwiththesavedscrewsmakingsurethatthegasketisbetween
theburnerboxandthenewignitorbracket.
7. Theclearancebetweenthemetalshieldoftheignitorandthe
burnershouldbebetween0”and1/8”.
8. Reconnecttheignitor.
9. Reinstalltheburnerboxcover.
10. Restorethegasandelectricalsupplytotheunit.
11.Setroomthermostatforheatandcyclethesystem.
12.Replaceburnercompartmentaccessdoor.
191E.NorthAvenue
CarolStreamIllinois60188USA
CustomerServiceTelephone1.800.304.6563
CustomerServiceFacsimile1.800.426.0804
Robertshaw®,Ranco®,Paragon®andUni-Line®are
trademarksofRobertshawitssubsidiariesand/or
affiliatedcompanies.Allotherbrandsmentioned
maybethetrademarksoftheirrespectiveowners.
ForTechnicalService
Telephone1.800.445.8299
Facsimile1.630.260.7294
www.uni-line.com
www.robertshaw.com
©2014Robertshaw
07/14–1-970RevC
Applicaon 3
Use Bracket
10-567
Applicaon 4
Use Bracket
10-570
Applicaon 5
Use Bracket
10-566