INSTALLATION DATA
BI-METAL GAS VALVES
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
Robertshaw®, Ranco®, Paragon® and Uni-Line® are
trademarks of Robertshaw, its subsidiaries and/or
affiliated companies. All other brands mentioned
may be the trademarks of their respective owners.
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
www.uni-line.com
www.robertshaw.com
©2014 Robertshaw
10/14 –1-960 RevB
Robertshaw® gas valves come in single and dual 115V models with or
without pilot take-o or in 3 volt versions for use with a silicon carbide
ignitor. Make sure your replacement valve has the correct warning label
for the range to be serviced.
CAUTION
THIS VALVE SHOULD BE REPLACED BY A QUALIFIED SERVICE
TECHNICIAN. IMPROPER INSTALLATION CAN PRESENT A
HAZARD.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING VALVES. WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS OPERATION.
WARNING:
DO NOT APPLY 115 VOLTS TO ANY VALVE USING A SILICON
CARBIDE IGNITOR AS IT WILL BURN THE WINDINGS OUT. IF
TEST SHOWS THE VALVE IS GOOD, CHECK FOR OTHER
REASONS FOR THE FAILURE.
The operang ambient temperature range for this valve is 32°F - 300°F.
This valve is cered for use with natural, LP manufactured, and
mixed gases.
TEST:
1. Turn o gas and disconnect electrical power.
2. To test valve, disconnect wires from valve terminals and test for
electrical connuity using a volt/ohm meter.
3. Remove old control. Note: When removing or replacing valve,
support valve inlet ng with a wrench.
4. Inspect electric wires for worn insulaon, breaks, etc., and replace
with original equipment wires, if necessary.
5. Make sure hood size on replacement valve is idencal to original
valve. DO NOT REMOVE OR REPLACE THE HOOD AND/OR PIN.
6. Extreme care must be taken not to let any foreign material, dirt,
burrs, etc., fall into hood outlet or valve inlet. This could present
a hazard.
7. For LP gas installaon, the hood should be screwed down against
the hood pin. For natural gas installaon, the hood should be
backed o two to three turns from the hood pin.
8. Replace the new control exactly as originally installed. Make sure all
gas connecons are ght and that the wires are properly aached.
9. Turn on gas and check for leaks using a diluted soap soluon applied
over all ngs. Watch for bubbles which would indicate a leak.
Aer test, rinse o soap soluon with water as soluon might cause
corrosion. Make sure electrical connecons are dry.
10. Connect electric power and test for operaon:
a. Turn on oven.
b. Check for ignion of burner.
c. If burner does not ignite within 140 seconds turn gas o and
reevaluate system for other problem.
Single Valve Dual Valve
115 Volt Silicon Carbide Igniter Silicon Carbide Igniter
ALTERNATE LABEL ALTERNATE LABEL ALTERNATE LABEL