Pioneer Faucets 4MT200T-BN Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Pioneer Faucets 4MT200T-BN Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Guide
Single Handle Tub And Shower Trim Set:
4MT100T•
4MT110T•
4MT120T•
4MT130T•
4MT200T•
4MT300T•
4MT320T•
4MT330T•
4MT400T•
This product meets the following standards:
ASME A112.18.1 •
ADA COMPLIANT•
REV-12 2, 13
Engineering Excellence
Pioneer Industries, Inc. © 2012
Engineering Excellence
Engineering E xcellence
2
REV-12 2, 13
Thank you for purchasing this Pioneer quality product.
Tools Required
Strap Wrench TeonTape Thermometer Allen Wrench Plumbers Putty
Prior to Installation
Observe all local plumbing and building codes before you begin •
installation.
Thenishedwallandtub/showervalve(4020Bor4020B-D)mustbein-•
stalled prior to installing this trim.
Shut off main water supply.•
Pioneer reserves the right to make changes in the design of faucets without •
noticeasspeciedinthepricebook.
Caution:(1).Theseproductsmaycausepersonalinjuryduetoscaldingif
the temperature is set too high. We recommend that temperature is set below
120°F(49°C).
3
REV-12 2, 13
Trim Installation (For 4MT100T, 4MT200T)
Remove the temporary nipple.•
IPS Installation:-•
The1/2”threadedpipenipplemustbekeptwithalengthof1-3/8”from•
nishedwall.
Fortubspout(A)withtubspoutescutcheon(B)slidethespout•
escutcheon(B)alongthethreadedpipenipple.Applyteontapeat
thethreadedconnection.Screwtubspout(A)ontothepipenippleand
tighten by strap wrench.
CXC Installation• :-
UseCXCto1/2”IPSadapter(X-5400009)andMountingTool•
(X-5400010)toinstallthetubspoutfor1/2”coppertubinginlet.Please
noteX-5400009andX-5400010needtobepurchasedseparately.
4
REV-12 2, 13
Trim Installation(For 4MT110T, 4MT120T)
Remove the temporary nipple.•
IPS Installation:-•
Note:- The 1/2” threaded pipe nipple must be kept with a length of •
7/16”fromnishedwall.
Applyteontapeatthethreadedconnection.Screwdivertertub•
spout(C)ontothepipenippleandtightenbystrapwrench.
CXC Installation• :-
UseCXCto1/2”IPSadapter(X-5400008)andMountingTool•
(X-5400010)toinstallthetubspoutfor1/2”coppertubinginlet.Please
noteX-5400008andX-5400010needtobepurchasedseparately.
5
REV-12 2, 13
Trim Installation (For 4MT100T, 4MT110T, 4MT300T)
Caution:-Toavoidpluggingtheshowerheadsprayoutletuseteontape•
on the shower arm threads.
Remove temporary nipple from the shower elbow.•
Usesilicontocaulkthebackoftheshowerarmange(D).•
Slidetheshowerarmange(D)overtheshowerarm(E).•
Applytheteontapeontheboththreadedendsofshowerarm(E)and•
installtheshowerarm(E)totheshowerelbow.
Carefully tighten with a clean strap wrench.•
Presstheshowerarmange(D)againstthenishedwall.•
Turnonmainwatersupplytoushoutthesystemforoneminute,then•
turn off main water supply.
Threadtheshowerhead(F)totheshowerarm(E).•
6
REV-12 2, 13
Trim Installation
Turn off the main water supply1.
Removetestcap(G)withthehelpof1-11/32”socket,relivethewater2.
pssureensureallthedebrisareushedoutofthesystem.
Threadsleeve(H)tothevalvebody.Insertthecartridge(I)tothevalve3.
body.EnsuretoinstallCartridgeunitsocoldwaterowsrst.Ensure
the two notches underneath of the cartridge seats properly in the valve
body.Holdthecartridge(I)andthreadthelocknut(J)tosleeve(H).
Threadretainercap(K)toretainernut(J).
For back to back installation:- Rotate the cartridge 180 Degree. Ensure 4.
‘B-BUP’symbolonthecartridgeisonthetop.Followtheinstructionon
3toinstallsleeve(H),locknut(J)andretainercap(K).
Turnonthemainwatersupply.Checkforanyleak.Turnthecartridge(I)5.
counterclockwise to the full open position. Allow water to run for some
time until the hot water comes out. Check the temperature with ther-
mometer for the hot water.
If necessary to reduce the hot water temperature then, turn off main 6.
watersupply.Removethecartridgebyremovingretainercap(K)
andlcoknut(J).Turnredtemperatureadjustingring(L)clockwiseto
decrease the temperature. Follow instruction 3 or 4 to reassemble the
cartridge(I).Ensurethehotwatertemperatureissetbelow120°F.
7
REV-12 2, 13
Trim Installation
8
REV-12 2, 13
Trim Installation
Placethefaceplate(N)onthevalve.Ensuretherubbergasket(M)is•
placedbehindthefaceplate(N)toformwatertightseal.Slidethees-
cutcheon(O)onthevalve.
Usesilicontocaulkaroundthefaceplate(N).•
Securethehandle(R)bytighteningtheallenscrew(P).Placeholecover•
(Q)onthehandle(R).Ensurethehandlerotatescounterclockwisefrom
coldtohotfrom6o’clockto3o’clock.
9
REV-12 2, 13
Trim Installation (For 4MT100T)
Remove the protective cover if placed on the valve.1.
Threadthevalvesleeve(S)onthevalve.Installthehandleadapter2.
(T)onthedivertervalvestem.securethehandleadapter(T)withthe
screw.
Slidethefaceplate(T)onthevalvesleeve.Ensuretherubbergasket3.
isbehindthefaceplate(T).Ifnecessaryapplysilicontocaulkaround
thefaceplate(T)toformwatertightseal.
Installthehandle(V)onthehandleadapter(T).Tightentheallen4.
screw(W)with3/32”sizeallenwrench.
Check if water diverts to desired outlet.•
For more care information or trouble shooting inquiries about your
Pioneer Product, please see the contact information on the back page.
10
REV-12 2, 13
3325S.GareldAve.|Commerce,CA90040
Telephone:(800)338-9468|(323)888-8873|Fax:(323)888-9515
Hours:M-F,7:30amto5:00pmPST
www.pioneerind.com
Engineering Excellence
Engineering E xcellence
/