108123-01B
For more information, visit www.desatech.com
For more information, visit www.desatech.com
2
Mounting Strips
2
1
/
2
" Nails
Level
Figure 3 - Installing Mounting Strips
47
1
/
4
"
Baseboard
Wall Studs
30" max
WARNING: Use care when finishing an unfin-
ished mantel. Finish pieces before assembly. Do not
finish mantel pieces near running heater or open
flame. Vapors from most finishing products are highly
flammable. Follow manufacturer’s guidelines when
using finishing products.
IMPORTANT:
If you are staining an unfinished mantel, sand entire
outside of mantel to remove any dirt or oils. This will prevent
blemishes from appearing under the stain. Stain mantel according to
manufacturer’s instructions. Apply sanding sealer.
IMPORTANT:
If you are painting an unfinished mantel, apply an
oil base undercoat to the mantel before painting. This will seal the
wood. After undercoat dries completely, lightly sand and apply an
oil base top coat. If you do not apply an oil base undercoat and
topcoat, the wood grain will bleed through the paint.
1. Mantel must be installed flush with wall. Baseboard will pre-
vent proper installation of mantel. Baseboard can either be
altered to fit mantel or removed.
Note:
To avoid scratching mantel front pieces during assem-
bly, place a sheet or blanket on floor where mantel will be
assembled.
2. Remove header front panel from carton. Note position of or-
nament on front to identify top of piece. Place header front
panel face down on floor. Attach one header block to bottom
left of header approximately centered with one 1
1
/4" wood
screw, leaving remainder of block to overhang about one half
its length (see Figure 1). Attach one header block to the top
left of header approximately centered with one 1
1
/4" wood
screw, leaving remainder of block to overhang about one half
its length (see Figure 1).
3. Lay mounting strips on the floor. Place left and right sides
face down on mounting strips. Use the mounting strips to give
you a flat surface to work on while attaching sides to header.
Set header between right and left sides (see Figure 2). The
mounting blocks should overhang the side panels.
ASSEMBLY AND INSTALLATION
INSTRUCTIONS
IMPORTANT
: To avoid damage to wood, do not kneel, lean,
or apply any pressure on the front panel in this position.
Slide header flush against left side. Align top of both pieces.
Insert 1
1
/4" wood screws through predrilled holes in mount-
ing block (see Figure 2). Make sure top of header and sides
are still flush and all pieces fit tightly together. Tighten screws
to fasten header to left side. Repeat to attach header to right
side (see Figure 2).
Note:
The mantel assembly will be loose until you attach the top.
4. Find studs in corner where mantel will be installed. Measure
47
1
/4" from floor or base if installed (see Figure 3). Mark
measurements parallel to floor. Align top of mounting strip
with penciled mark within 30" of the corner. Use a level to
ensure mounting strips are level (see Figure 3). Attach strip to
wall with two 2
1
/2" nails.
Note:
Do not use smaller nails.
These nails will be load-bearing. Repeat above steps to attach
mounting strip to facing wall.
Floor or Top of
Base if Used
Header
(Face Down)
Figure 1 - Attaching Header Blocks to Header
Header Blocks
1
1
/
4
" Wood Screw
Header
Figure 2 - Connecting Header to Left and Right Legs
Legs
Wall Mounting
Strips
1
1
/
4
" Wood Screw
Header Block