Arrowhead Alarm Products NANO-O1 Operating instructions

Type
Operating instructions
Garage Door 2
Garage Door Push
to Operate Button
NANO-O1 INSTRUCTIONS
PIN COLOUR FUNCTION
1 Red +12VDC In
2 Black -0VDC
3 Yellow Clock
4 Blue Data
5 White Input
- Green x2 Output
NANO
O1
page 1/1
Single output expander module for ESL system.
This module wires directly onto the ESL keypad bus. It features a single clean normally open
contact, rated to 30VDC 100mA, making this device ideal from controlling garage doors and gate
controllers.
41mm
POS
NEG
CLK
DAT
ESL Panel
NO/NC
100m Max. Ø0.2mm Follow Dip 1 Dip 2 Dip3
Out 1 off off off
Out 2 on off off
Out 3 off on off
Out 4 on on off
Out 5 off off on
Out 6 on off on
Out 7 off on on
Out 8 on on on
Example:
= Output 5
optional
ARROWHEAD ALARM PRODUCTS Ltd.
1A Emirali Road,
Silverdale 0932,
Auckland, NZ
Ph. 09 414 0085
www.aap.co.nz v1.01
Learning Optional Input
For the Input of a NANO-O1 to work on the Elite system, you need to learn it in to a user slot. This is done at address
18. In Installer mode press <PROGRAM> <18> <ENTER> then choose the user slot <21-100> and
<ENTER><ENTER>, trigger the device. (this should stop the keypad beeping.)
i.e. P 18 E 30 E E (device is now learnt in to user 30).
user slot
address
The User Slot can then be configure to, Trigger an output, Arm/Disarm, Panic Alarm.
Please see the full programming manual for more information. www.aap.co.nz
Dipswitch 4 On
to enable input
  • Page 1 1