AcuityBrands UV222 User manual

Category
Floodlights
Type
User manual
IMPORTANT SAFETY INSTRUCTIONS
OCCUPIED SPACES DIRECT IRRADIATION UV EQUIPMENT
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other
hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of this equipment should be performed by a qualified licensed electrician.
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized
personnel.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
Do not use this equipment for other than intended use.
It is the obligation of the end-user to consult with appropriately qualified Professional Engineer(s), Certified Infection Control
professionals, and Certified Industrial Hygienists, as applicable, to determine whether this equipment and its installation meets
the applicable requirements for system performance, code compliance, safety, suitability and effectiveness for use in a
particular application design.
DO NOT INSTALL DAMAGED PRODUCT! This equipment has been properly packed so that no parts should have been damaged
during transit. Inspect to confirm. Any equipment damaged or broken during or after installation should be replaced. Contact
the manufacturer for replacement.
DO NOT INSTALL BELOW THE MINIMUM HEIGHT SPECIFIED IN THESE INSTALLATION INSTRUCTIONS.
Follow all disposal laws when replacing or disposing. Excimer lamps do not contain hazardous materials and can be recycled by
standard electronics recyclers.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to
meet in connection with installation, operation, or maintenance. Should further information be desired, or should problems
arise which are not covered sufficiently for the purchaser’s or owner’s purposes, please contact Technical Services at Acuity
Brands Lighting, 800-705-SERV (7378).
*Asterisked statements only apply to UV222 and UV222H configurations, not applicable to UV222VL configurations. UV222VL
configurations do not have a UVC emitter, no UVC precautions necessary with UV222VL configurations.
This equipment is designed for use with germicidal UV radiation sources and must be installed in compliance with competent
technical directions to prevent risk of personal injury from UV radiation.*
UV radiation can pose a risk of personal injury. Overexposure can result in damage to eyes and bare skin. To reduce the risk of
overexposure this equipment must be installed in accordance with the manufacturer’s site planning recommendations. This may
include instructions on the relative location of each germicidal system component, the minimum distances between UV-
generating devices and other objects or surfaces, and protection from line-of-sight exposure to UV radiation in occupied spaces
located above the equipment mounting area (e. g. upper floor balconies, open staircases, etc.).*
UV and optical radiation can be reflected by surrounding surfaces such as ceilings and walls. Since the reflective properties of
surfaces can vary widely, it should be considered as part of site planning. Follow the manufacturer’s recommendations for
selecting appropriate ceiling and wall finishes.*
IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT PERSONS WILL NOT BE EXPOSED TO EXCESSIVE UV OR OPTICAL
RADIATION DURING EQUIPMENT OPERATION. THIS WILL REQUIRE THE INSTALLER TO CONDUCT AN ASSESSMENT OF
IRRADIANCE OR ILLUMINANCE LEVELS IN THE SURROUNDING OCCUPIED SPACES PRIOR TO OCCUPANCY.*
Maintenance and servicing of this UV generating equipment shall be performed by authorized personnel. Service personnel
must wear appropriate Personal Protective Equipment (PPE) if the equipment will be in operation during the maintenance or
servicing work. Contact the equipment manufacturer for PPE recommendations and guidance.*
Take precautions to ensure that the concentration of ozone in the installation is limited to a value that is within applicable
permissible exposure limits. Verify acceptable ozone concentrations in the installation taking into account the number of
products in a given volume of space, the characteristics of the ventilation system, access, and other factors. Permissible
exposure limits vary based on the place of ozone application, the length of exposure, and other factors and are publicly
available. For reference, the EPA National Ambient Air Quality Standard is 0.070 ppm maximum concentration averaged over 8
hours and current OSHA regulations set an eight-hour time-weighted average permissible exposure limit of 0.10 ppm. The
amount of ozone emitted by this equipment does not exceed a concentration of 0.001 ppm over an 8-hour period, as tested in
accordance with UL 867.*
UVC module not intended for use with wall switches. Connect to an unswitched circuit intended for 24/7/365 continuous
operation.*
To ensure that the equipment may continue to operate as designed, replacements for the proprietary UV Module System (UV
Lamp Module and Dosage Controller) must be purchased from Acuity Brands Lighting. Contact Acuity Brands Lighting when the
UV Lamp Module reaches end of life.*
This equipment, including the lamp modules, must be stored in a dust-free environment and be handled while wearing clean
gloves. Since far-UVC radiation is absorbed by proteins and other organic compounds, accumulation of dust particles or touching
of the optical radiation surface will negatively impact the output of the UV radiation source. Follow recommended cleaning
procedures when dirt is observed on the lens and as part of a regular maintenance cleaning cycle.*
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
912-00312-001 Rev. B
Page 1 of 12
Disconnect or turn off power before installation or
servicing.
Verify that supply voltage is correct by comparing it with
the equipment label information.
Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and any
applicable local code requirements.
All wiring connections should be capped with UL approved
recognized wire connectors.
WARNING
RISK OF ELECTRIC SHOCK
Allow lamp/fixture to cool before handling. Do not touch
hot lens, lamp, guard, or enclosure.
Follow all lamp manufacturer’s warnings,
recommendations and restrictions on lamp operation
including but not limited to: ballast type, burning
position, replacement, and recycling.
WARNING
RISK OF BURN
Wear gloves and safety glasses at all times when removing
equipment from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF INJURY
Keep combustible and other materials that can burn away
from lamp/lens.
Do not operate in close proximity to persons,
combustible materials or substances affected by heat or
drying.
CAUTION
RISK OF FIRE
Disconnect or turn off power to equipment before
performing maintenance or servicing other elements in the
ceiling or space that require closer proximity than normal
standing height away from the equipment.
Skin or eye injury may result from overexposure to the
light produced by the lamp in this equipment at distances
less than 24 in. from the emitter.
Emitters used within this equipment are in the EXEMPT
RISK GROUP for actinic UV (200-400nm), near UV (315-
400nm), and blue light (300-700nm) hazards, as described
in IEC 62471, when installed and used according to
instructions in this document.
This equipment emits UV radiation which can cause
degradation of many materials. Remove or protect these
materials prior to operation of the unit.
CAUTION
UV EXPOSURE RISKS
UV222 & UV222H ONLY*
IMPORTANT SAFETY INSTRUCTIONS
OCCUPIED SPACES DIRECT IRRADIATION UV EQUIPMENT
PRECAUTIONARY STATEMENTS
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
This equipment emits UV radiation at wavelengths less
than 250 nm which can generate ozone.
Take precautions to ensure that ozone concentration
stays within applicable permissible exposure limits
described on page 1 of this document.
CAUTION
OZONE EXPOSURE RISK
UV222 & UV222H ONLY*
*Asterisked warnings only apply to UV222 and UV222H configurations, not applicable to UV222VL configurations.
UV222VL configurations do not have a UVC emitter, no UVC precautions necessary with UV222VL configurations.
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
912-00312-001 Rev. B
Page 2 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
IMPORTANT SAFETY INSTRUCTIONS
OCCUPIED SPACES DIRECT IRRADIATION UV EQUIPMENT
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire
must be checked for compatibility with the luminaire prior to installation. LED components must be powered
directly from a switched circuit while UVC components must be powered directly from an unswitched circuit.
Unless individual product specifications deem otherwise, do not restrict fixture ventilation. Allow for some
volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
Unless individual product specifications deem otherwise, do not exceed fixture’s maximum ambient temperature.
Only use fixture in its intended location.
LED products are polarity sensitive. Ensure proper polarity before installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all
installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service,
stop using the unit immediately and contact an Acuity Brands Lighting representative for assistance.
Always read the fixture’s complete installation instructions prior to installation for any additional fixture specific
warnings.
Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure
and may void warranty.
CAUTION: RISK OF PRODUCT DAMAGE
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part
15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other
electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause
interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or
communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties available at www.acuitybrands.com/support/warranty. For
technical assistance, call 800-705-SERV (7378).
EPA Establishment Number: 97727-IN-1. For sale only in the United States of America and Mexico. Not registered as a pesticide device and not intended for sale into the
following U.S. states: Colorado, Hawaii, Indiana, New Mexico, Oklahoma, West Virginia, Wyoming, and the District of Columbia.
Does not meet California air cleaner regulation requirements; cannot be shipped to California.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
912-00312-001 Rev. B
Page 3 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
UV Emitter Information
HIGHEST IRRADIANCE AT 500 mm: 0.51 W/m2
Dosing is listed as height from floor to the mounting surface of the luminaire.
Minimum floor to mounting surface height:
*All measurements in μW/cm2measured at plane 7 ft. above floor -1x1 ft. grid
**All measurements in mJ/cm2per 8 hours, measured at plane 7 ft. above floor -1x1 ft. grid. ACGIH guideline for maximum dose is 22.87 mJ/cm2
per 8 hours. Consult an Acuity Brands UV Lighting Specialist for layout of multiple-luminaire installations.
EVO6…D108 = 105 Inch (min) to 111 Inch (max) height from floor to mounting surface
EVO6…D114 = 111 Inch (min) to 117 Inch (max) height from floor to mounting surface
EVO6…D120 = 117 Inch (min) to 123 Inch (max) height from floor to mounting surface
EVO6…D126 = 123 Inch (min) to 129 Inch (max) height from floor to mounting surface
EVO6…D132 = 129 Inch (min) or greater height from floor to mounting surface
THIS PAGE ONLY APPLIES TO UV222 & UV222H CONFIGURATIONS
When line voltage is applied to the luminaire, the Status Indicator LED should appear as a green solid light. The UV lamp
module will remain inactive for between 11 and 12 minutes. Complete any mechanical adjustments to the luminaire
before applying line voltage, or else ensure that any work on or near the luminaire that would require any part of the
installer to be more than 7 ft. off the floor is complete within the first 11 minutes after line voltage is applied to prevent
the installer from receiving a UV dose that is larger than the recommended amount.
The UV lamp module will operate on 12-minute cycles, activating for a duration between 10 and 50 seconds each cycle.
The duration will depend on the Programming Option value in each luminaire’s order nomenclature (e.g. EVO6D108).
Refer to the product Spec Sheet for guidance in selecting the correct Programming Option value for each application.
When activated, the UV module will illuminate with a soft violet glow (see image below). The Status Indicator LED will
remain green whether the UV module is active or inactive if all self-diagnostics report proper function.
The Status Indicator LED may reflect additional states throughout the lifetime of the luminaire. The possible states are as
follows:
The UV lamp modules are rated for approximately 5 years of life (3000 activated hours). The Status Indicator LED will
change to yellow solid when six months of projected life are left in the lamp module. Contact Acuity Brands Lighting for
service.
912-00312-001 Rev. B
Page 4 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
EVO6 CARE222 Downlight
DESCRIPTION OF NORMAL OPERATION
UV222H: Visible light integrated with 222nm UV module
UV222: 222nm UV module only
UV222VL: Visible light only (no UV module)
UVC Module
Violet hue visible
during on cycle
Luminaire Variant Mounting Kits (Included)
New Construction Catalog #EVO6 UV222H/UV222/UV222VL Hanger Bars
7” Remodel Catalog #EVO6RM UV222H/UV222/UV222VL Spring Clips
These installation instructions are used for installing the following luminaires and kits
EVO6 CARE222 Downlight
INSTALLATION INSTRUCTIONS
UV222H: Visible light integrated with 222nm UV module
UV222: 222nm UV module only
UV222VL: Visible light only (no UV module)
A) Identification of Luminaire Variants...................................................................
Page 6
B) Care222 Information Label Removal and Placement.......................................
Page 6
C) Installation Compatibility…………………………………………………………...
Page 7
D) New Construction Reflector Installation………………………………………….
Page 7
E) Lay-in Panel T-bar Ceiling InstallationNew Construction Only......................
Page 8
F) Non-Accessible Ceiling Installation New Construction Only…………………
Page 9
G) New Construction Installation Flangeless Version Only................................
Page 9
H) 7” Remodel Variant Installation.........................................................................
Page 10
I) Alternative Remodel Variants.............................................................................
Page 10
J) 6” Remodel (CC6) Variant Installation...............................................................
Page 11
K) Cleaning Instructions.........................................................................................
Page 12
912-00312-001 Rev. B
Page 5 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
B) Care222 Information Label Removal and Placement
1Remove the Care222 Information Label (the lower
rectangular portion of the hanging label).
2Remove sticker backing and affix label in a location
that will be visible after installation and likely to be
discovered by future maintenance personnel.
Suggested locations include: a cover plate near the
entrance to the room containing the Care222 fixture,
the electrical panel supplying the luminaire branch
circuit, or a clean, smooth wall near the room
entrance.
912-00312-001 Rev. B
Page 6 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
A) Identification of Luminaire Variants
New Construction 7” Remodel
C) Installation Compatibility
New Construction
Minimum ceiling thickness: ½”
Maximum ceiling thickness: 1½”
Minimum plenum depth: 9”
Minimum mounting surface height as directed
by specified dosing module (see page 3)
Remodel
Ceiling opening: 7” (Min. 6” with CC6 option)
(Max 8¾” with CC8 option)
Minimum ceiling thickness: ½”
Maximum ceiling thickness: 1½”
Minimum plenum depth: 9”
Minimum mounting surface height as directed
by specified dosing module (see page 3)
Gotham fixtures not containing “ICAT” (type non-IC) are
designed for installations where the housing and J-box will not
come into contact with insulation.* Insulation and combustible
materials must be spaced at least 3” away from the housing
and J-Box. Blinking or powering off of the light during use
indicates an overheating condition which may be cause by
insulating material being too close to or covering fixture.
Align the slot openings on the reflector with
the screws located on the outer housing of
the luminaire. Press up on the reflector and
twist to install the reflector onto the
luminaire.
With reflector in place, hand tighten screws with
Phillips driver to ensure reflector is securely
attached to the luminaire.
Note: Correct installed position shown above.
1 2
D) New Construction Reflector Installation
New construction versions require installation of reflector as shown below prior to mounting
luminaire into the ceiling.
TYPE NON-IC FOR USE IN NON INSULATED CEILINGS
Caution: Failure to correct an overheating
condition may result in fire and serious injury.
912-00312-001 Rev. B
Page 7 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
E) Lay-in Panel T-bar Ceiling InstallationNew Construction Only
1
Cut 7-1/4” (18.4cm) ceiling opening to
accommodate for the mounting frame.
2
Position mounting frame through the
opening in the ceiling. Release clamping
latch arms and adjust channel bars to the
correct spacing between T-bar as shown in
the figure in Step 4.
3
Secure channel bars to T-bar by means of
bending ends onto T-bar as shown above.
Use wire ties, screws, or other securement
methods as dictated by local code.
4
Once mounting frame has been secured in
structure, adjust it vertically to align the
aperture bottom edge flush or slightly above
(1/8” max) the ceiling line. Lock into position
by closing the clamping latch arm.
5
If additional security is required, a No. 8
sheet metal screw, wire tie or wire (not
supplied) may be used to secure the latch
arm to the mounting frame as shown
above.
6
Remove knockouts on junction box using a
flat screwdriver to pry at slots. Feed power
supply to fixture. Supply wire must meet
applicable electrical codes and be rated for
a minimum of 90˚C, conduit connector to
be used.
Closed
Open
Clamping
Latch Arms
8
Pinch torsion springs on fixture and locate
the torsion spring bracket on the plaster
frame. Once springs are secured in both
brackets, secure fixture to the ceiling by
pushing up on the reflector until flush with
mounting surface. For thick ceilings,
brackets can be moved to secondary
position by utilizing the second set of
holes. Validate mounting height meets
requirements on page 4.
7b
7a
Note: This step is for UV222VL and UV222H
configurations.
Open junction box and locate wires without
labels. These wires will be connected to
standard SWITCHED power (120VAC or 277AC,
50/60hz). Complete necessary splices and snap
the junction box door back into place. DIM
wires to be used where applicable. UV222H
fixtures: ground to be shared with step 7a
connections.
Note: This step is for UV222 and UV222H
configurations.
Locate wires labeled “UNSWITCHED”. These
wires to be used with UNSWITCHED power
(120VAC or 277AC, 50/60hz). Complete
necessary splices as shown above. UV222
fixtures: snap junction box door into place.
UV222H fixtures: continue to step 7b.
UV222 and UV222H UV222VL and UV222H
UVC module wiring LED driver wiring
912-00312-001 Rev. B
Page 8 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
12
Position mounting frame through the
opening in the ceiling. Release clamping
latch arms and adjust channel bars to the
correct spacing between T-bars. Move to
section F for flangeless trim option.
F) Non-Accessible Ceiling Installation New Construction Only
3
Release clamping latch arms and adjust
channel bars to the correct spacing between
joists (Channel bars will accommodate up to
24” O.C. joists).
Closed
Open
Clamping
Latch Arms
4
Bend ends of channel bars 90˚ and mount
to joists with vertical adjustment at its
lowest point on the mounting frame. Make
sure the bottom of the flange is flush with
the bottom of the joists. Close clamping
latch arm to secure frame.
5
Return to section D, Step 5 to complete
installation.
If non-flexible wiring method is used, first
lower mounting frame equal to the
thickness of the finished ceiling or slightly
above.
G) New Construction Installation Flangeless Version Only
1
The flangeless style trims require the use
of a mud ring to properly install them into
the ceiling. Remove the mud ring from its
packaging and follow the instructions
located in its packaging.
2
Return to section E, Step 3 to complete the
installation.
Cut 7-1/4” (18.4cm) ceiling opening to
accommodate for the mounting frame.
912-00312-001 Rev. B
Page 9 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
H) 7” Remodel Variant Installation
3
Feed Junction box through the ceiling
opening and allow it to rest on the ceiling.
2b
Guide fixture through the ceiling opening.
Once flange is seated on the ceiling, push
the springs out. Push spring until a click is
heard, locking the tab onto the housing.
Repeat for remaining springs. Validate
mounting height meets requirements on
page 4.Reflector can now be pressed into
the housing.
4
2a
Note: This step is for UV222 and UV222H
configurations.
Open junction box and locate wires
labeled “UNSWITCHED”. These wires to be
used with UNSWITCHED power (120VAC or
277AC, 50/60hz). Complete necessary
splices as shown above. UV222 fixtures:
snap junction box door into place. UV222H
fixtures: continue to step 2b.
Note: This step is for UV222VL and UV222H
configurations.
Open junction box and locate wires without
labels. These wires will be connected to
standard SWITCHED power (120VAC or
277AC, 50/60hz). Complete necessary
splices and snap the junction box door back
into place. DIM wires to be used where
applicable. UV222H fixtures: ground to be
shared with step 2a connections.
1
Cut 7” (18.4cm) ceiling opening to
accommodate for the mounting frame.
Feed required power supply to this
opening. Supply wire must meet applicable
electrical codes and be rated for a
minimum of 90˚C, connect to junction box
with conduit connector.
I) Alternative Remodel Variants
1
For existing ceiling openings between 6”
and 7”, EVO6RM (CC6) option needed.
Follow instructions in section I for EVO6RM
(CC6) installation.
2
For existing ceiling openings between 7”
and 8¾”, EVO6RM (CC8) option needed.
Install supplied goof ring over lower
housing as shown above. Follow section G
instructions.
UV222 and UV222H
UV222VL and UV222H
UVC module wiring
LED driver wiring
2
For UV222 configuration: go to step 2a
For UV222VL configuration: go to step 2b
For UV222H configuration: go to step 2a
and then step 2b
912-00312-001 Rev. B
Page 10 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
J) 6” Remodel (CC6) Variant Installation
Guide the spring through the slot as shown
above. Place the curved end through the
upper slot and pinch the spring to fit the T-
shaped end through the lower slot. Repeat for
remaining springs.
Feed Junction box through the ceiling
opening and allow it to rest on the ceiling.
Follow steps 4-6 (springs) for ceilings
thicker than ¾”, steps 7-8 (retaining clips)
for ceilings thinner than ¾”.
345
Feed the curved portion of the spring
through the upper slot so that the spring is
flat against the inside of the lower housing.
Repeat for remaining springs.
6
Push up on the spring to secure the fixture
in the ceiling. Repeat for remaining
springs. Validate mounting height meets
requirements on page 4. Press in new
reflector.
2b
2a
Note: This step is for UV222 and UV222H
configurations.
Locate wires labeled “UNSWITCHED”.
These wires to be used with UNSWITCHED
power (120VAC or 277AC, 50/60hz).
Complete necessary splices as shown
above. UV222 fixtures: snap junction box
door into place. UV222H fixtures: continue
to step 2b.
Note: This step is for UV222VL and UV222H
configurations.
Open junction box and locate wires without
labels. These wires will be connected to
standard SWITCHED power (120VAC or
277AC, 50/60hz). Complete necessary
splices and snap the junction box door back
into place. DIM wires to be used where
applicable. UV222H fixtures: ground to be
shared with step 2a connections.
7
Insert retaining clip into housing, leading
the long edge through the upper slot as
shown.
8
While holding housing flush with the
mounting surface, push clips downward as
you hand tighten screws with a Phillips
driver. Repeat for remaining clips. Validate
mounting height meets requirements on
page 4. Press in new reflector.
UV222 and UV222H
UVC module wiring LED driver wiring
UV222VL and UV222H
1
Cut 7” (18.4cm) ceiling opening to
accommodate for the mounting frame.
Feed required power supply to this
opening. Supply wire must meet applicable
electrical codes and be rated for a
minimum of 90˚C, connect to junction box
with conduit connector.
912-00312-001 Rev. B
Page 11 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
1Disconnect power to the unit prior to opening or performing any maintenance.
K) Cleaning Instructions
2Wipe off exterior dirt and debris using a soft, clean cloth. A mild detergent and water may be used if
necessary. CAUTION: DO NOT USE ABRASIVE CLEANERS ON THE LENS. THEIR USE MAY RESULT
IN DAMAGE.
3
If dust or fingerprints are present on the lens, clean the glass with a non-abrasive cleaner, such as a glass
cleaner or disinfecting wipes. It is recommended that the glass be cleaned periodically to retain intended
UV-C transmission.
912-00312-001 Rev. B
Page 12 of 12
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

AcuityBrands UV222 User manual

Category
Floodlights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI