BHL INSTALL INSTRUCTIONS 10
1400 Lester Rd NW, Conyers, GA 30012 • Tel: 800.705.SERV(7378) • Email: •Website: https://luminaireled.acuitybrands.com/
© 2021 Acuity Brands Lighting, Inc. All Rights Reserved. “LuminaireLED”is a registered trademark of Acuity Brands Lighting. Products in
this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies.
Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
12/2021
912-00232-000
12
2B
Push the luminaire against ceiling to minimize gaps and
finish installation.
3B
**For IP required applications** Sealant or gasket must
be field applied between overlap flange and ceiling before
installed into ceiling. Acuity Brands is not responsible for
materials or installation that would ensure IP66 room
rating.
Tilt and push the luminaire into the rough cut and
support the luminaire using the support brackets
illustrated in step 2B. **Mounting means and/or
fasteners provided by others.**
4B
Locate and identify the support bracket on the
luminaire. If access to plenum is available and/or using
snap in template is not possible the luminaire can be
supported via these brackets.
5B
Locate luminaire access plate and make wiring
connections. Insulation detectors may vary based on
ordered configuration. If “NLT” or “NLIGHT” is ordered
ensure to locate and plug in the RJ45 adaptor.
Step 12 concludes non plenum access
(FL) installations, Step 2B through 5B
illustrates optional plenum access (FL)
installation