Gotham Lighting EVO® 6" Round Pendant Mount Cylinder Installation guide

Type
Installation guide
IMPORTANT SAFETY INSTRUCTIONS
OCCUPIED SPACES DIRECT IRRADIATION UV EQUIPMENT
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other
hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of this equipment should be performed by a qualified licensed electrician.
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized
personnel.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
Do not use this equipment for other than intended use.
It is the obligation of the end-user to consult with appropriately qualified Professional Engineer(s), Certified Infection Control
professionals, and Certified Industrial Hygienists, as applicable, to determine whether this equipment and its installation meets
the applicable requirements for system performance, code compliance, safety, suitability and effectiveness for use in a
particular application design.
DO NOT INSTALL DAMAGED PRODUCT! This equipment has been properly packed so that no parts should have been damaged
during transit. Inspect to confirm. Any equipment damaged or broken during or after installation should be replaced. Contact
the manufacturer for replacement.
DO NOT INSTALL BELOW THE MINIMUM HEIGHT SPECIFIED IN THESE INSTALLATION INSTRUCTIONS.
Follow all disposal laws when replacing or disposing. Excimer lamps do not contain hazardous materials and can be recycled by
standard electronics recyclers.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to
meet in connection with installation, operation, or maintenance. Should further information be desired, or should problems
arise which are not covered sufficiently for the purchaser’s or owner’s purposes, please contact Technical Services at Acuity
Brands Lighting, 800-705-SERV (7378).
*Asterisked statements only apply to UV222 and UV222H configurations, not applicable to UV222VL configurations. UV222VL
configurations do not have a UVC emitter, no UVC precautions necessary with UV222VL configurations.
This equipment is designed for use with germicidal UV radiation sources and must be installed in compliance with competent
technical directions to prevent risk of personal injury from UV radiation.*
UV radiation can pose a risk of personal injury. Overexposure can result in damage to eyes and bare skin. To reduce the risk of
overexposure this equipment must be installed in accordance with the manufacturer’s site planning recommendations. This may
include instructions on the relative location of each germicidal system component, the minimum distances between UV-
generating devices and other objects or surfaces, and protection from line-of-sight exposure to UV radiation in occupied spaces
located above the equipment mounting area (e. g. upper floor balconies, open staircases, etc.).*
UV and optical radiation can be reflected by surrounding surfaces such as ceilings and walls. Since the reflective properties of
surfaces can vary widely, it should be considered as part of site planning. Follow the manufacturer’s recommendations for
selecting appropriate ceiling and wall finishes.*
IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT PERSONS WILL NOT BE EXPOSED TO EXCESSIVE UV OR OPTICAL
RADIATION DURING EQUIPMENT OPERATION. THIS WILL REQUIRE THE INSTALLER TO CONDUCT AN ASSESSMENT OF
IRRADIANCE OR ILLUMINANCE LEVELS IN THE SURROUNDING OCCUPIED SPACES PRIOR TO OCCUPANCY.*
Maintenance and servicing of this UV generating equipment shall be performed by authorized personnel. Service personnel
must wear appropriate Personal Protective Equipment (PPE) if the equipment will be in operation during the maintenance or
servicing work. Contact the equipment manufacturer for PPE recommendations and guidance.*
Take precautions to ensure that the concentration of ozone in the installation is limited to a value that is within applicable
permissible exposure limits. Verify acceptable ozone concentrations in the installation taking into account the number of
products in a given volume of space, the characteristics of the ventilation system, access, and other factors. Permissible
exposure limits vary based on the place of ozone application, the length of exposure, and other factors and are publicly
available. For reference, the EPA National Ambient Air Quality Standard is 0.070 ppm maximum concentration averaged over 8
hours and current OSHA regulations set an eight-hour time-weighted average permissible exposure limit of 0.10 ppm. The
amount of ozone emitted by this equipment does not exceed a concentration of 0.001 ppm over an 8-hour period, as tested in
accordance with UL 867.*
UVC module not intended for use with wall switches. Connect to an unswitched circuit intended for 24/7/365 continuous
operation.*
To ensure that the equipment may continue to operate as designed, replacements for the proprietary UV Module System (UV
Lamp Module and Dosage Controller) must be purchased from Acuity Brands Lighting. Contact Acuity Brands Lighting when the
UV Lamp Module reaches end of life.*
This equipment, including the lamp modules, must be stored in a dust-free environment and be handled while wearing clean
gloves. Since far-UVC radiation is absorbed by proteins and other organic compounds, accumulation of dust particles or touching
of the optical radiation surface will negatively impact the output of the UV radiation source. Follow recommended cleaning
procedures when dirt is observed on the lens and as part of a regular maintenance cleaning cycle.*
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
912-00308-001 Rev. B
Page 1 of 17
Disconnect or turn off power before installation or
servicing.
Verify that supply voltage is correct by comparing it with
the equipment label information.
Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and any
applicable local code requirements.
All wiring connections should be capped with UL approved
recognized wire connectors.
WARNING
RISK OF ELECTRIC SHOCK
Allow lamp/fixture to cool before handling. Do not touch
hot lens, lamp, guard, or enclosure.
Follow all lamp manufacturer’s warnings,
recommendations and restrictions on lamp operation
including but not limited to: ballast type, burning
position, replacement, and recycling.
WARNING
RISK OF BURN
Wear gloves and safety glasses at all times when removing
equipment from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF INJURY
Keep combustible and other materials that can burn away
from lamp/lens.
Do not operate in close proximity to persons,
combustible materials or substances affected by heat or
drying.
CAUTION
RISK OF FIRE
Disconnect or turn off power to equipment before
performing maintenance or servicing other elements in the
ceiling or space that require closer proximity than normal
standing height away from the equipment.
Skin or eye injury may result from overexposure to the light
produced by the lamp in this equipment at distances less
than 24 in. from the emitter.
Emitters used within this equipment are in the EXEMPT
RISK GROUP for actinic UV (200-400nm), near UV
(315-400nm), and blue light (300-700nm) hazards, as
described in IEC 62471, when installed and used according
to instructions in this document.
UV emitters used in this equipment can cause the limited
photodegradation of many materials over years of
operation. For the few materials where photodegradation
may be more significant (such as PVC), remove or protect
these materials prior to operation of the unit if degradation
is a concern. Tested materials are identified in the
Photodegradation Testing Results summarized on the
specification sheet for this equipment.
CAUTION
UV EXPOSURE RISKS
UV222 & UV222H ONLY*
IMPORTANT SAFETY INSTRUCTIONS
OCCUPIED SPACES DIRECT IRRADIATION UV EQUIPMENT
PRECAUTIONARY STATEMENTS
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
This equipment emits UV radiation at wavelengths less
than 250 nm which can generate ozone.
Take precautions to ensure that ozone concentration
stays within applicable permissible exposure limits
described on page 1 of this document.
CAUTION
OZONE EXPOSURE RISK
UV222 & UV222H ONLY*
*Asterisked warnings only apply to UV222 and UV222H configurations, not applicable to UV222VL configurations.
UV222VL configurations do not have a UVC emitter, no UVC precautions necessary with UV222VL configurations.
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
912-00308-001 Rev. B
Page 2 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
IMPORTANT SAFETY INSTRUCTIONS
OCCUPIED SPACES DIRECT IRRADIATION UV EQUIPMENT
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire
must be checked for compatibility with the luminaire prior to installation. LED components must be powered
directly from a switched circuit while UVC components must be powered directly from an unswitched circuit.
Unless individual product specifications deem otherwise, do not restrict fixture ventilation. Allow for some
volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
Unless individual product specifications deem otherwise, do not exceed fixture’s maximum ambient temperature.
Only use fixture in its intended location.
LED products are polarity sensitive. Ensure proper polarity before installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all
installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service,
stop using the unit immediately and contact an Acuity Brands Lighting representative for assistance.
Always read the fixture’s complete installation instructions prior to installation for any additional fixture specific
warnings.
Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure
and may void warranty.
CAUTION: RISK OF PRODUCT DAMAGE
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part
15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other
electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause
interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or
communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties available at www.acuitybrands.com/support/warranty. For
technical assistance, call 800-705-SERV (7378).
EPA Establishment Number: 97727-IN-1. For sale only in the United States of America and Mexico. Not registered as a pesticide device and not intended for sale into the
following U.S. states: Colorado, Hawaii, Indiana, New Mexico, Oklahoma, West Virginia, Wyoming, and the District of Columbia.
Does not meet California air cleaner regulation requirements; cannot be shipped to California.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
912-00308-001 Rev. B
Page 3 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
UVC Module
Violet hue visible
during on cycle
THIS PAGE ONLY APPLIES TO UV222 & UV222H CONFIGURATIONS
Cylinder Aperture
When line voltage is applied to the luminaire, the Status Indicator LED should appear as a green solid light. The UV lamp
module will remain inactive for between 11 and 12 minutes. Complete any mechanical adjustments to the luminaire
before applying line voltage, or else ensure that any work on or near the luminaire that would require any part of the
installer to be more than 7 ft. off the floor is complete within the first 11 minutes after line voltage is applied to prevent
the installer from receiving a UV dose that is larger than the recommended amount.
The UV lamp module will operate on 12-minute cycles, activating for a duration between 10 and 50 seconds each cycle.
The duration will depend on the Programming Option value in each luminaire’s order nomenclature (e.g. EVO6D108).
Refer to the product Spec Sheet for guidance in selecting the correct Programming Option value for each application.
When activated, the UV module will illuminate with a soft violet glow (see image below). The Status Indicator LED will
remain green whether the UV module is active or inactive if all self-diagnostics report proper function.
The Status Indicator LED may reflect additional states throughout the lifetime of the luminaire. The possible states are as
follows:
The UV lamp modules are rated for approximately 5 years of life (3000 activated hours). The Status Indicator LED will
change to yellow solid when six months of projected life are left in the lamp module. Contact Acuity Brands Lighting
for service.
The UV Module only version is an ultraviolet (UV) based device that is not serviceable. The Hybrid (H) version contains an
embedded UV based device that is not separable from the fixture and is also not serviceable. Therefore, if this fixture
experiences a failure due to a defect in material or workmanship after the warranty period has expired or the fixture
reaches the end of its useful life then, if continued operation is desired, a new fixture must be purchased.
912-00308-001 Rev. B
Page 4 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
EVO6 CARE222® Cylinders
DESCRIPTION OF NORMAL OPERATION UV222H: Visible light integrated with 222nm UV module
UV222: 222nm UV module only
UV222VL: Visible light only (no UV module)
UV Emitter Information
HIGHEST IRRADIANCE AT 500 mm: 0.51 W/m2
Dosing is listed as height from floor to the mounting surface of the luminaire.
Minimum floor to mounting surface height:
*All measurements in μW/cm2measured at plane 7 ft. above floor -1x1 ft. grid
**All measurements in mJ/cm2per 8 hours, measured at plane 7 ft. above floor -1x1 ft. grid. ACGIH guideline for maximum dose is 22.87 mJ/cm2
per 8 hours. Consult an Acuity Brands UV Lighting Specialist for layout of multiple-luminaire installations.
EVO6…D108 = 105 Inch (min) to 111 Inch (max) height from floor to cylinder aperture
EVO6…D114 = 111 Inch (min) to 117 Inch (max) height from floor to cylinder aperture
EVO6…D120 = 117 Inch (min) to 123 Inch (max) height from floor to cylinder aperture
EVO6…D126 = 123 Inch (min) to 129 Inch (max) height from floor to cylinder aperture
EVO6…D132 = 129 Inch (min) or greater height from floor to cylinder aperture
912-00308-001 Rev. B
Page 5 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
EVO6 CARE222® Cylinders
DESCRIPTION OF NORMAL OPERATION UV222H: Visible light integrated with 222nm UV module
UV222: 222nm UV module only
UV222VL: Visible light only (no UV module)
These installation instructions are used for installing the following luminaires and kits.
Luminaire Variants Mounting Type Mounting Type Description
EVO6PC UV222H (Visible Light and UV Module)
EVO6PC UV222 (UV Module Only)
EVO6PC UV222VL (Visible Light Only)
JBX Integral driver, Recessed or Surface J-
box
JBXCC Integral driver, Surface J-box with
Conduit Covers
EVO6 CARE222® Cylinders
INSTALLATION INSTRUCTIONS
A) Identification of Pendant Stem Luminaires…............................... ………….……………………… Page 6
B) Identification of Parts…................................................................ ………….……………………… Page 7
C) Stem Length Calculation………………………………………….... ………….……………………… Page 8
D) Care222 Information Label Removal and Placement………...…. …………………………………. Page 9
E) Stem End Hole Drilling for Swivel Ball…...................................... ………….……………………… Page 9
F)Stem Cylinder Assembly…........................................................... ………….……………………… Page 10
G) Conduit Canopy Assembly (JBXCC)…......................................... ………….……………………… Page 11
H) Fixture Install…………………..….................................................. ………….……………………… Page 12
I) Cleaning Instructions………………………………………………... ………….……………………… Page 17
JBX
(Recessed
J-box)
JBX
(Sloped Ceiling
Canopy)
JBX
(Surface
J-box)
JBXCC
(Ceiling
Canopy)
JBXCC
(Slope Ceiling
Canopy)
A) Identification of Pendant Mount Luminaires
UV222H: Visible light integrated with 222nm UV module
UV222: 222nm UV module only
UV222VL: Visible light only (no UV module)
912-00308-001 Rev. B
Page 6 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
B) Identification of Parts
Stem Cylinder
Assembly
b)
c)
a)
Stem
a) External and internal threaded ends
iEVO6PC external threads: 3/8-18 NPSM
b) Internal threaded ends
i. EVO6PC internal threads: 1/4-18 NPSM
c) Threaded nipple
Stem Hardware
a) Swivel ball
b) Screw (2)
a) #8-32 x 3/8”
Lg. Pan
Head
b)
a)
a) b)
Canopy Assembly
a) JBX Canopy
b) JBXCC Canopy
Conduit Keys (JBXCC Only)
a) Blank Conduit Key (4)
b) Conduit Key (4)
c) 5/64” Allen wrench (1)
a) c) b)
912-00308-001 Rev. B
Page 7 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
Calculate the necessary stem length per the equations below.
C) Stem Length Calculation
1
Cut line
Stem Length (2 MINIMUM)
Cut off
WARNING: DO NOT CUT OFF
EXTERNAL THREAD SIDE OF PIPE
If there are multiple sections of stem, assemble them together using the threaded nipples provided.
2
Cut the assembled stem to the calculated length per Step 1.
3
Stem Length = B A 11
A
B
Desired
illuminated
surface
Mounting Plane
(J-Box)
Bottom of
cylinder
Mounting Height (in)
B
Surface J-Box Sloped Surface
(45deg)
Measure B from
center of J-Box
for length
calculation with
sloped surfaces.
Recessed J-box
Fixture Height (in)
A
912-00308-001 Rev. B
Page 8 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
E) Stem End Hole Drilling for Swivel Ball
123
Locate the swivel ball and stem that
has already been assembled and cut
to length.
Place swivel ball on the stem
end opposite of the external
threads.
4 5
Make sure ball is seated on the
top of the stem. Thread screws
into each side of the swivel ball to
secure it in place before drilling.
Using the guide holes in the ball and
a drill with a 3/16” drill bit, drill
through both sides of the stem.
Loosen screws and remove swivel ball
from stem for later assembly steps.
Note: Swivel Ball will be secured to the
stem in a later step by tightening screws
and engaging them into the holes that
were drilled in the end of the stem.
3/16”
drill bit
912-00308-001 Rev. B
Page 9 of 17
D) Care222® Information Label Removal and Placement
1Remove the Care222 Information Label (the lower
rectangular portion of the hanging label).
2Remove sticker backing and affix label in a location
that will be visible after installation and likely to be
discovered by future maintenance personnel.
Suggested locations include: a cover plate near the
entrance to the room containing the Care222 fixture,
the electrical panel supplying the luminaire branch
circuit, or a clean, smooth wall near the room
entrance.
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
F) Stem Cylinder Assembly
1Unscrew cap from cylinder. Align stem with the cylinder so
the external threads of the stem are closest to the top of
the cylinder. Pull the wires through the stem, then thread it
into the cylinder. Leave at least 6” of wires coming out of
the end of the stem.
Note: Set screw may need to be loosened to allow
threading in the stem.
2Once the stem has been threaded in fully, tighten the
set screw to lock the stem in the cylinder. Then screw
on and hand tighten the cap.
Set Screw
Cap
6” MIN
Cap
912-00308-001 Rev. B
Page 10 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
G) Conduit Canopy Assembly (JBXCC)
1
2 3
If JBX fixture, skip to Section H. Select the appropriate keys and insert them into the correct canopy slots for each
specific J-box configuration. Adjust set screws in the keys to allow the keys to slide in completely.
Note: Keys accept ½” and ¾” EMT conduit ONLY. Conduit fittings may vary by manufacturer. If using ¾” set
screw type fittings, the fitting may need to be rotated so that the set screw is off vertical for proper clearance
with canopies.
Loosen screws securing the plate to the
canopy so the screws can slide within the
slots.
Bring canopy up to J-box and insert J-box screws into key slots.
Rotate the plate attached to the canopy to allow the J-box
screws to slide into the key slots. Tighten the screws that secure
the plate to the canopy. This will secure the canopy to the ceiling
for fixture install. Leave J-box screws loose for fixture install.
Screw
Screw
Screws Screws
Plate
Rotate ¾” set
screw fittings
off vertical
NOTE: JBXCC mounting type requires a 1.5” depth, 4” octagonal junction box.
912-00308-001 Rev. B
Page 11 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
2
1Slide Canopy (1), Mounting Bracket (2), and
Swivel Ball (3) onto stem in below order.
Note: Rest the Canopy and Mounting Bracket
on the top of the cylinder.
1
2
3
H) Fixture Install
Thread screws into swivel ball and align with drilled
holes in stem. Tighten screws so they are engaged
through the holes in the stem.
Drilled Hole (x2)
NOTE:
JBX mounting type fixtures require a 1.5” minimum depth, 4” octagonal junction box.
JBXCC mounting type fixtures require a 1.5” depth, 4” octagonal junction box.
Recessed junction boxes cannot be more than 1/8” proud of the ceiling surface.
WARNING: All pendant fixtures exposed to wind require tethering consult factory.
3Align swivel ball groove with mounting plate tab as
it is brought up to secure to ceiling.
912-00308-001 Rev. B
Page 12 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
H) Fixture Install Continued…
4Bring the fixture up to junction box with the swivel
ball seated in the mounting plate. 5Pull stem wires through the multiple triangular cutouts in
the mounting plate. Also pull the corresponding supply
wires through each respective cutout.
Triangular
Cutout
Do not pull
wires through
square cutouts.
JBX
Supply Wires, Visible Light
(SWITCHED CIRCUIT)
JBXCC
Supply Wires, UV Module
(UNSWITCHED CIRCUIT)
912-00308-001 Rev. B
Page 13 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
7
8
Use the keyholes in the mounting bracket to
secure it with the J-box screws. Align screws
with the indication marks on the bracket.
Adjust as necessary for fixture alignment.
Tighten screws.
After securing mounting plate, make wire connections per below diagram and
push them through the mounting bracket cutouts into the J-box.
H) Fixture Install Continued…
EVO6PC UV222H (Visible Light and UV Module)
GREEN WIRE FROM
STEM
GRAY (or PINK)
PURPLE
WHITE
BLACK
DIM (-)
DIM (+)
NEUTRAL
HOT
GROUND
J-BOX
CONNECTIONS
NEUTRAL
HOT
GROUND
WIRES LABELED
SWITCHED
WIRES LABELED
UNSWITCHED
BLACK
WHITE
SUPPLY
WIRES
VISIBLE
LIGHT
CIRCUIT
BRANCH
SUPPLY WIRES
UN-SWITCHED UV
CIRCUIT BRANCH
CYLINDER
COPPER WIRE (FROM
MOUNTING PAN)
CYLINDER
912-00308-001 Rev. B
Page 14 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
H) Fixture Install Continued…
GREEN WIRE
FROM STEM
CYLINDER
WHITE
BLACK
NEUTRAL
HOT
J-BOX
CONNECTIONS
CYLINDER
COPPER WIRE
(FROM MOUNTING PAN)
GROUND
SUPPLY WIRES
UN-SWITCHED UV
CIRCUIT BRANCH
EVO6PC UV222 (UV Module Only)
EVO6PC UV222VL (Visible Light Only)
COPPER WIRE (FROM
MOUNTING PAN)
CYLINDER
GRAY (or PINK)
PURPLE
WHITE
BLACK
GREEN WIRE
(FROM STEM)
DIM (-)
DIM (+)
NEUTRAL
HOT
GROUND
J-BOX
CONNECTIONS
SUPPLY
WIRES
VISIBLE
LIGHT
CIRCUIT
BRANCH
WIRES LABELED
UNSWITCHED
912-00308-001 Rev. B
Page 15 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
9Bring the canopy up to the ceiling and align the spring clips on the canopy with the rectangular cutouts on
the bracket. Push the canopy up to the ceiling to snap the clips into the cutouts to secure the canopy.
H) Fixture Install Continued…
Spring Clips Rectangular
Cutouts
JBX
912-00308-001 Rev. B
Page 16 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
1Disconnect power to the unit prior to opening or performing any maintenance.
I) Cleaning Instructions
2Wipe off exterior dirt and debris using a soft, clean cloth. A mild detergent and water may be used if
necessary. CAUTION: DO NOT USE ABRASIVE CLEANERS ON THE LENS. THEIR USE MAY RESULT
IN DAMAGE.
3
If dust or fingerprints are present on the lens, clean the glass with a non-abrasive cleaner, such as a glass
cleaner or disinfecting wipes. It is recommended that the glass be cleaned periodically to retain intended
UV-C transmission.
912-00308-001 Rev. B
Page 17 of 17
Gotham | Acuity Brands Lighting, Inc., One Lithonia Way, Conyers, GA 30012 • 800-705-SERV (7378) • www.gothamlighting.com
Gotham, nLight, and the Acuity Brands logos are registered trademarks of Acuity Brands. Care222 is a registered trademark of Ushio America, Inc.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
© 2021-2023 Acuity Brands Lighting, Inc. All Rights Reserved.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Gotham Lighting EVO® 6" Round Pendant Mount Cylinder Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI