ALLEGION RC-04 ISONAS Reader Controll User guide

Category
Security device components
Type
User guide
Cat5e/6 to PoE Switch
4750 Walnut Street Suite 110
Boulder, CO 80301
www.isonas.com
Date:
7-24-18 Drawn By:
David Tamarchenko Version:
1.00.00
Dwg No: Sheet
1of1
RC-04.AnalogLockdown.ALACM8
12/24VDC Electric
Strike
Com
NC
NO
Fire alarm relay
ALWAYS drops power
to fail safe locking
hardware to maintain
code compliance
Com
NC
NO
Fire alarm relay
ALWAYS drops power
to fail safe locking
hardware to maintain
code compliance
NC Door
Contact
NC Door
Contact
12/24 VDC
Magnetic Lock
IRSIRS
Com 2
NC 2
NO 2
+12VDC
-12VDC
REX Motion
Com 1
NC 1
NO 1
Com 2
NC 2
NO 2
+12VDC
-12VDC
REX Motion
Com 1
NC 1
NO 1
Exit Button (30 sec.)
COM
NC
+12VDC
-12VDC
COM
NC
+12VDC
-12VDC
Exit Button (30 sec.)
COM
NC
+12VDC
-12VDC
Black
Orange
Yellow
Red
White
Blue
Green
Brown
Cat5e/6 to PoE Switch
Isolate and insulate
wires not used
Wht
Yel
Bk
Org
NO
NC
COM
GND
V+
Wht
Yel
Bk
Org
NO
NC
COM
GND
V+
Wht
Yel
Bk
Org
NO
NC
COM
GND
V+
Remove factory jumper wire
from V+ to COM!
Remove factory jumper wire
from V+ to COM!
Wht
Yel
Bk
Org
NO
NC
COM
GND
V+
Remove factory jumper wire
from V+ to COM!
NC Door
Contact
NC Door
Contact
F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F8F8
PA Lockdown
notification to AUX
input (Custom Rules
required for emails
and alarm conditions
Output #2 breaks
positive leg of lock
power to fail secure
device during
lockdown Output #4 shorts
positive leg of lock
power to constant
voltage for a fail safe
device during
lockdown
Lockdown Initiate
Via Siren and
Timer Output
NO
COM
Lockdown Initiate
Via Siren and
Timer Output
NO
COM
Isolate and insulate
wires not used
White: RS-232 RXD
Yellow: RS-232 TXD
Purple: TTL Out 1
Brown: TTL Out 2
Orange: AUX Input
Green: REX Input
Red: +12VDC Buss
Black: Ground
Blue: Door Input
Tan: Relay N.O.
Pink: Relay COM
Grey: Relay N.C.
Isolate and insulate
wires not used
White: RS-232 RXD
Yellow: RS-232 TXD
Purple: TTL Out 1
Brown: TTL Out 2
Orange: AUX Input
Green: REX Input
Red: +12VDC Buss
Black: Ground
Blue: Door Input
Tan: Relay N.O.
Pink: Relay COM
Grey: Relay N.C.
Tan
Pnk
Bk
Red
NO
NC
COM
GND
V+
Tan
Pnk
Bk
Red
NO
NC
COM
GND
V+
Tan
Pnk
Bk
Red
NO
NC
COM
GND
V+
Remove factory jumper wire
from V+ to COM!
Remove factory jumper wire
from V+ to COM!
Tan
Pnk
Bk
Red
NO
NC
COM
GND
V+
Remove factory jumper wire
from V+ to COM!
Black
Orange
Yellow
Red
White
Blue
Green
Brown
Cat5e/6 to PoE Switch
Isolate and insulate
wires not used
Black
Orange
Yellow
Red
White
Blue
Green
Brown
Cat5e/6 to PoE Switch
Isolate and insulate
wires not used
PA Lockdown
Initiate Via
Lock Output
RBSNRBSN
POS+ CNC NO
NEG- CNC NO
RBSN
POS+ CNC NO
NEG- CNC NO
  • Page 1 1