Juniper PTX10003-80C, PTX10003-160C User manual

  • Hello! I am an AI chatbot trained to assist you with the Juniper PTX10003-80C User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PTX10003-80C and PTX10003-160C
Fixed Packet Transport Router Hardware
Guide
Published
2019-10-03
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000
www.juniper.net
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. in
the United States and other countries. All other trademarks, service marks, registered marks, or registered service marks
are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right
to change, modify, transfer, or otherwise revise this publication without notice.
PTX10003-80C and PTX10003-160C Fixed Packet Transport Router Hardware Guide
Copyright © 2019 Juniper Networks, Inc. All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related
limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with)
Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement
(“EULA”) posted at https://support.juniper.net/support/eula/. By downloading, installing or using such software, you
agree to the terms and conditions of that EULA.
ii
Table of Contents
About the Documentation | xi
Documentation and Release Notes | xi
Using the Examples in This Manual | xi
Merging a Full Example | xii
Merging a Snippet | xiii
Documentation Conventions | xiii
Documentation Feedback | xvi
Requesting Technical Support | xvi
Self-Help Online Tools and Resources | xvii
Creating a Service Request with JTAC | xvii
Overview
1
PTX10003 System Overview | 21
Benefits of the PTX10003 | 21
PTX10003-160C | 22
PTX10003-80C | 23
PTX10003 System Architecture | 24
PTX10003 System Software | 24
PTX10003 Fixed-Configuration Router Specifications | 25
PTX10003 Port Panel | 26
PTX10003-160C Port Panel | 26
PTX10003-80C Port Panel | 27
Understanding QSFP-DD Interfaces and Configurations | 28
Allowable QSFP-DD Interface Configurations for the PTX10003-160C | 29
Allowable QSFP-DD Interface Configurations for the PTX10003-80C | 30
Examples of PTX10003 QSFP-DD Configurations | 30
Example: Using Network Ports as 10 Gbps or 40 Gbps Ethernet Interfaces | 31
Example: Using Network Ports as 100 Gbps Ethernet Interfaces | 32
Example: Using Network Ports as 200 Gbps Ethernet Interfaces | 32
Example: Using Network Ports as 1x400 Gbps Ethernet Interfaces | 33
iii
PTX10003 Port LEDs | 34
Channelizing Interfaces on PTX10003 Routers with Junos OS Evolved | 35
PTX10003 Field-Replaceable Units Panel | 36
PTX10003-160C FRU Panel | 37
PTX10003-80C FRU Panel | 39
PTX10003 Management Panel | 40
PTX10003 Management Panel Components | 41
PTX10003 Management Panel LEDs | 42
PTX10003 Cooling System Description and Airflow | 46
PTX10003 Fan Modules | 46
PTX10003 Chassis Airflow | 47
Fan Module Status and LED Description | 48
PTX10003 Power System | 50
PTX10003 AC/HVDC Power Supply Description | 50
PTX10003 AC/HVDC Power Supply LED | 52
PTX10003 AC/HVDC Power Specifications | 56
PTX10003 AC Power Cord Specifications | 56
PTX10003 DC Power Supply Description | 59
PTX10003 DC Power Supply LED | 61
PTX10003 DC Input Current Selector (DIP Switch) | 62
PTX10003 DC Power Redundancy | 63
PTX10003 Input DC Voltage Specification | 63
PTX10003 DC Power Cables | 64
PTX10003 DC Power Lugs | 64
Viewing Power Statistics | 65
iv
Site Planning, Preparation, and Specifications
2
PTX10003 Site Preparation Checklist | 71
PTX10003 Site Guidelines and Requirements | 72
PTX10003 Environmental Requirements and Specifications | 73
General Site Guidelines | 74
PTX10003 Chassis Grounding Cable and Lug Specifications | 74
PTX10003 Clearance Requirements for Airflow and Hardware Maintenance | 75
PTX10003 Chassis Physical Specifications | 76
PTX10003 Rack Requirements | 76
PTX10003 Network Cable and Transceiver Planning | 78
Determining Transceiver Support for the PTX10003 | 78
Cable and Connector Specifications for MX and PTX Series Devices | 79
12-Fiber MPO Connectors | 79
24-Fiber MPO Connectors | 83
LC Duplex Connectors | 84
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion | 85
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable | 85
Attenuation and Dispersion in Fiber-Optic Cable | 86
Calculating Power Budget and Power Margin for Fiber-Optic Cables | 86
Calculating Power Budget for Fiber-Optic Cable | 87
Calculating Power Margin for Fiber-Optic Cable | 87
PTX10003 Management Cable Specifications and Pinouts | 89
PTX10003 Cable Specifications for Console and Management Connections | 89
PTX10003 Management Port Connector Pinouts | 90
PTX10003 Console Port Connector Pinouts | 90
PTX10003 SFP Port Connector Pinouts | 91
PTX10003 SFP+ Port Connector Pinouts | 92
PTX10003 QSFP+ and QSFP28 Port Connector Pinouts | 93
PTX10003 USB Port Specifications | 95
v
Initial Installation and Configuration
3
PTX10003 Installation Overview | 99
Overview of Installing the PTX10003 | 99
PTX10003 Installation Safety Guidelines | 100
General Installation Safety Guidelines | 100
Chassis Lifting Guidelines | 100
Unpacking and Mounting the PTX10003 | 101
Unpacking the PTX10003 | 101
Mounting the PTX10003 in a Rack | 103
Before You Begin Mounting the PTX10003 | 103
Mounting the PTX10003 | 105
Connect the PTX10003 to Power | 109
Connecting the PTX10003 to Ground | 110
Connecting AC Power to the PTX10003 | 112
Connecting DC Power to the PTX10003 | 114
Connecting the PTX10003-80C to External Devices | 120
Connecting the PTX10003-80C to a Management Ethernet Device | 120
Connecting the PTX10003-80C to a Management Console | 121
Registering Products—Mandatory for Validating SLAs | 122
Performing the Initial Software Configuration for the PTX10003 | 123
Powering Off the PTX10003 | 125
Powering Off the AC-Powered PTX10003 | 126
Powering Off the DC-Powered PTX10003 | 127
vi
Maintaining Components
4
Maintaining the PTX10003 Fan Modules | 131
Removing a Fan Module from the PTX10003 | 131
Installing a Fan Module in the PTX10003 | 132
Maintaining the PTX10003 Power Supplies | 134
Replacing an AC/HVDC Power Supply in the PTX10003 | 134
Remove the AC/HVDC Power Supply from the PTX10003 | 135
Install the AC/HVDC Power Supply in the PTX10003 | 137
Replacing an DC Power Supply in the PTX10003 | 139
Remove the DC Power Supply from the PTX10003 | 139
Install the DC Power Supply in the PTX10003 | 141
Maintaining Transceivers and Fiber-Optic Cables on the PTX10003-80C | 143
Removing a Transceiver from the PTX10003-80C | 143
Installing a Transceiver in the PTX10003-80C | 146
Disconnecting a Fiber-Optic Cable from a PTX10003-80C | 148
Connecting a Fiber-Optic Cable to a PTX10003-80C | 149
Maintaining Fiber-Optic Cables | 150
Uninstalling the PTX10003 | 151
Troubleshooting Hardware
5
Troubleshooting the PTX10003 | 155
PTX10003 Troubleshooting Resources Overview | 155
PTX10003 Alarm Messages Overview | 156
PTX10003 System Alarm Messages and Recommended Actions | 156
Contacting Customer Support and Returning the Chassis or Components
6
Contacting Customer Support | 163
Returning the PTX10003 Chassis or Components | 163
Locating the Serial Number on a PTX10003 Chassis or Component | 164
Listing the PTX10003 Chassis and Component Details by Using the CLI | 164
Locating the PTX10003 Chassis Serial Number ID Label | 167
vii
Locating the Serial Number ID Labels on PTX10003 Components | 167
Returning a PTX10003 or Component for Repair or Replacement | 169
Contacting Customer Support to Obtain Return Material Authorization | 170
Packing a PTX10003 Chassis or Component for Shipping | 171
Packing a PTX10003 Chassis for Shipping | 171
Packing a PTX10003 Component for Shipping | 172
Safety and Compliance Information
7
General Safety Guidelines and Warnings | 175
Definitions of Safety Warning Levels | 176
Qualified Personnel Warning | 178
Warning Statement for Norway and Sweden | 179
Fire Safety Requirements | 179
Fire Suppression | 179
Fire Suppression Equipment | 179
Installation Instructions Warning | 181
Chassis and Component Lifting Guidelines | 181
Restricted Access Warning | 183
Ramp Warning | 185
Rack-Mounting and Cabinet-Mounting Warnings | 185
Grounded Equipment Warning | 190
Laser and LED Safety Guidelines and Warnings | 190
General Laser Safety Guidelines | 191
Class 1 Laser Product Warning | 192
Class 1 LED Product Warning | 193
Laser Beam Warning | 194
viii
Radiation from Open Port Apertures Warning | 195
Maintenance and Operational Safety Guidelines and Warnings | 196
Battery Handling Warning | 197
Jewelry Removal Warning | 198
Lightning Activity Warning | 200
Operating Temperature Warning | 201
Product Disposal Warning | 203
General Electrical Safety Guidelines and Warnings | 204
Action to Take After an Electrical Accident | 205
Prevention of Electrostatic Discharge Damage | 205
AC Power Electrical Safety Guidelines | 207
AC Power Disconnection Warning | 208
DC Power Electrical Safety Guidelines | 209
DC Power Copper Conductors Warning | 210
DC Power Disconnection Warning | 211
DC Power Grounding Requirements and Warning | 213
DC Power Wiring Sequence Warning | 215
DC Power Wiring Terminations Warning | 218
Multiple Power Supplies Disconnection Warning | 221
TN Power Warning | 222
PTX10003 Regulatory Standard Compliances | 222
PTX10003 Agency Approvals | 223
Compliance Statements for the PTX10003 Routers | 225
Canada | 225
European Community | 226
Israel | 226
Japan | 226
Korea | 226
ix
Taiwan | 227
United States | 227
x
About the Documentation
IN THIS SECTION
Documentation and Release Notes | xi
Using the Examples in This Manual | xi
Documentation Conventions | xiii
Documentation Feedback | xvi
Requesting Technical Support | xvi
Use this guide to install hardware and perform initial software configuration, routine maintenance, and
troubleshooting for the PTX10003-80C and PTX10003-160C Fixed Packet Transport Router. Once you
complete installation and perform the basic configuration procedures covered in this guide, refer to the
Junos OS documentation for information about further software configuration.
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
®
technical documentation, see the product
documentation page on the Juniper Networks website at https://www.juniper.net/documentation/.
If the information in the latest release notes differs from the information in the documentation, follow the
product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts.
These books go beyond the technical documentation to explore the nuances of network architecture,
deployment, and administration. The current list can be viewed at https://www.juniper.net/books.
Using the Examples in This Manual
If you want to use the examples in this manual, you can use the load merge or the load merge relative
command. These commands cause the software to merge the incoming configuration into the current
candidate configuration. The example does not become active until you commit the candidate configuration.
xi
If the example configuration contains the top level of the hierarchy (or multiple hierarchies), the example
is a full example. In this case, use the load merge command.
If the example configuration does not start at the top level of the hierarchy, the example is a snippet. In
this case, use the load merge relative command. These procedures are described in the following sections.
Merging a Full Example
To merge a full example, follow these steps:
1. From the HTML or PDF version of the manual, copy a configuration example into a text file, save the
file with a name, and copy the file to a directory on your routing platform.
For example, copy the following configuration to a file and name the file ex-script.conf. Copy the
ex-script.conf file to the /var/tmp directory on your routing platform.
system {
scripts {
commit {
file ex-script.xsl;
}
}
}
interfaces {
fxp0 {
disable;
unit 0 {
family inet {
address 10.0.0.1/24;
}
}
}
}
2. Merge the contents of the file into your routing platform configuration by issuing the load merge
configuration mode command:
[edit]
user@host# load merge /var/tmp/ex-script.conf
load complete
xii
Merging a Snippet
To merge a snippet, follow these steps:
1. From the HTML or PDF version of the manual, copy a configuration snippet into a text file, save the
file with a name, and copy the file to a directory on your routing platform.
For example, copy the following snippet to a file and name the file ex-script-snippet.conf. Copy the
ex-script-snippet.conf file to the /var/tmp directory on your routing platform.
commit {
file ex-script-snippet.xsl; }
2. Move to the hierarchy level that is relevant for this snippet by issuing the following configuration mode
command:
[edit]
user@host# edit system scripts
[edit system scripts]
3. Merge the contents of the file into your routing platform configuration by issuing the load merge
relative configuration mode command:
[edit system scripts]
user@host# load merge relative /var/tmp/ex-script-snippet.conf
load complete
For more information about the load command, see CLI Explorer.
Documentation Conventions
Table 1 on page xiv defines notice icons used in this guide.
xiii
Table 1: Notice Icons
DescriptionMeaningIcon
Indicates important features or instructions.Informational note
Indicates a situation that might result in loss of data or hardware
damage.
Caution
Alerts you to the risk of personal injury or death.Warning
Alerts you to the risk of personal injury from a laser.Laser warning
Indicates helpful information.Tip
Alerts you to a recommended use or implementation.Best practice
Table 2 on page xiv defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
ExamplesDescriptionConvention
To enter configuration mode, type
the configure command:
user@host> configure
Represents text that you type.Bold text like this
user@host> show chassis alarms
No alarms currently active
Represents output that appears on
the terminal screen.
Fixed-width text like this
A policy term is a named structure
that defines match conditions and
actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities
Attribute
Introduces or emphasizes important
new terms.
Identifies guide names.
Identifies RFC and Internet draft
titles.
Italic text like this
xiv
Table 2: Text and Syntax Conventions (continued)
ExamplesDescriptionConvention
Configure the machine’s domain
name:
[edit]
root@# set system domain-name
domain-name
Represents variables (options for
which you substitute a value) in
commands or configuration
statements.
Italic text like this
To configure a stub area, include
the stub statement at the [edit
protocols ospf area area-id]
hierarchy level.
The console port is labeled
CONSOLE.
Represents names of configuration
statements, commands, files, and
directories; configuration hierarchy
levels; or labels on routing platform
components.
Text like this
stub <default-metric metric>;Encloses optional keywords or
variables.
< > (angle brackets)
broadcast | multicast
(string1 | string2 | string3)
Indicates a choice between the
mutually exclusive keywords or
variables on either side of the symbol.
The set of choices is often enclosed
in parentheses for clarity.
| (pipe symbol)
rsvp { # Required for dynamic MPLS
only
Indicates a comment specified on the
same line as the configuration
statement to which it applies.
# (pound sign)
community name members [
community-ids ]
Encloses a variable for which you can
substitute one or more values.
[ ] (square brackets)
[edit]
routing-options {
static {
route default {
nexthop address;
retain;
}
}
}
Identifies a level in the configuration
hierarchy.
Indention and braces ( { } )
Identifies a leaf statement at a
configuration hierarchy level.
; (semicolon)
GUI Conventions
xv
Table 2: Text and Syntax Conventions (continued)
ExamplesDescriptionConvention
In the Logical Interfaces box, select
All Interfaces.
To cancel the configuration, click
Cancel.
Represents graphical user interface
(GUI) items you click or select.
Bold text like this
In the configuration editor hierarchy,
select Protocols>Ospf.
Separates levels in a hierarchy of
menu selections.
> (bold right angle bracket)
Documentation Feedback
We encourage you to provide feedback so that we can improve our documentation. You can use either
of the following methods:
Online feedback system—Click TechLibrary Feedback, on the lower right of any page on the Juniper
Networks TechLibrary site, and do one of the following:
Click the thumbs-up icon if the information on the page was helpful to you.
Click the thumbs-down icon if the information on the page was not helpful to you or if you have
suggestions for improvement, and use the pop-up form to provide feedback.
E-mail—Send your comments to [email protected]. Include the document or topic name,
URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance Center (JTAC).
If you are a customer with an active Juniper Care or Partner Support Services support contract, or are
covered under warranty, and need post-sales technical support, you can access our tools and resources
online or open a case with JTAC.
xvi
JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User
Guide located at https://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf.
Product warranties—For product warranty information, visit https://www.juniper.net/support/warranty/.
JTAC hours of operation—The JTAC centers have resources available 24 hours a day, 7 days a week,
365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called
the Customer Support Center (CSC) that provides you with the following features:
Find CSC offerings: https://www.juniper.net/customers/support/
Search for known bugs: https://prsearch.juniper.net/
Find product documentation: https://www.juniper.net/documentation/
Find solutions and answer questions using our Knowledge Base: https://kb.juniper.net/
Download the latest versions of software and review release notes:
https://www.juniper.net/customers/csc/software/
Search technical bulletins for relevant hardware and software notifications:
https://kb.juniper.net/InfoCenter/
Join and participate in the Juniper Networks Community Forum:
https://www.juniper.net/company/communities/
Create a service request online: https://myjuniper.juniper.net
To verify service entitlement by product serial number, use our Serial Number Entitlement (SNE) Tool:
https://entitlementsearch.juniper.net/entitlementsearch/
Creating a Service Request with JTAC
You can create a service request with JTAC on the Web or by telephone.
Visit https://myjuniper.juniper.net.
Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
For international or direct-dial options in countries without toll-free numbers, see
https://support.juniper.net/support/requesting-support/.
xvii
1
CHAPTER
Overview
PTX10003 System Overview | 21
PTX10003 Port Panel | 26
PTX10003 Field-Replaceable Units Panel | 36
PTX10003 Management Panel | 40
PTX10003 Cooling System Description and Airflow | 46
PTX10003 Power System | 50
PTX10003 System Overview
IN THIS SECTION
Benefits of the PTX10003 | 21
PTX10003-160C | 22
PTX10003-80C | 23
PTX10003 System Architecture | 24
PTX10003 System Software | 24
PTX10003 Fixed-Configuration Router Specifications | 25
Occupying only 3 U, the PTX10003 is the industry’s first fixed-configuration core router to support 400 GbE.
The PTX10003 is easy to deploy in space constrained Internet exchange locations, remote central offices,
and embedded peering points throughout the network, including cloud-hosted services. It uniquely addresses
power-constrained environments by providing unprecedented power efficiency of 0.2 watts/Gbps. The
PTX10003 delivers high density 10 GbE, 26 GbE, 40 GbE, 100 GbE, 200 GbE, and 400 GbE and inline
MACsec with no compromise in throughput or latency. Two models with differing capacities are available.
The PTX10003-160C supports 16 Tbps throughput and the PTX10003-80C supports 8 Tbps
throughput—each in a compact 3 U footprint.
TIP: For information about features supported on PTX Series routers, see Feature Explorer.
Benefits of the PTX10003
Juniper Networks ExpressPlus™ Silicon: The PTX10003 is powered by our custom ExpressPlus silicon,
providing predictable IP/MPLS packet performance and functionality, along with inline AES-256 MACsec
encryption on all interfaces.
Peering Scale: To match the expanding traffic demands, the PTX10003 delivers a peering scale of up to
3 million Forwarding Information Base (FIB) routes and up to 20 million Routing Information Base (RIB)
routes, also known as forwarding and routing tables, respectively.
QSFP-DD: The PTX10003 supports universal multi-rate QSFP-DD optics, quadrupling aggregate switch
bandwidth while maintaining port density. QSFP-DD supports continuing growth in network bandwidth