B8 Mantle Clearance
Mantles or protruding ledges above the heater must not be installed lower
than the dimension shown to the right.
NOTE: dimension from base of appliance.
B9 Television Clearances
The following are the recommended minimum clearances for the location of any electrical
equipment (such as a Plasma TV, LCD TV or home theatre system) above an Escea DX Series
gas fire.
NOTE: The above television clearance recommendations are to be treated
as a suggestion of a suitable installation only. It is the responsibility of the
end user to check the installation instructions of their electrical appliances
to ensure that the location in relation to the gas fire is suitable. Escea in no
way guarantees or takes responsibility that the above installation suggestion
will be suitable for all electrical or home entertainment appliances.
NOTE: Dimension is from base of appliance.
For installations with a recessed TV above, allow at least 300mm above
the top of the appliance to allow for duct and flue routing.
B10 Ducting
NOTE: The duct fan must be installed in a location accessible for service or replacement; a service
hatch to allow for access may be required.
This gas fire requires a small network of ducting situated in either the ceiling or under the floor
to distribute heat generated by the appliance.
A centrifugal fan (separate purchase) is connected to the duct system. This draws air through
the appliance where it is heated and distributes it via the ducting network. The centrifugal fan is
powered by the appliance. When placing outlets in rooms other than the room the appliance is
installed in, it is important to allow for return air to equalise pressure between the rooms.
Caution: Provision must always be made for return air from heated rooms e.g. undercut
doors or natural leakage.
WARNING: OVERHEATED ROOMS ARE NOT SAFE FOR INFANTS
DX fires require a minimum of three outlets in the ducting system to be fully open at all times.
At least two of those outlets must be present in the same room that the fire resides in. There
can be a maximum of five outlets for the DX1000 and eight outlets for the DX1500.
A standard duct kit (separate purchase) has provision for the three minimum outlets - You can
use your own ductwork and outlets, but you must ensure they are rated to temperatures of at
least 90 degrees Celsius and have an appropriate R-value.
Ductwork must be adequately sized to avoid excess backpressures. Inadequate duct sizes will
cause unnecessary fan noise and premature fan failure.