Range hood DF-SG8 / DF-SG9
Built-in range hood
J541.53-1
13.12.13 FUW
1
These installation instructions apply to the models:
Extraction mode
p-V diagram
All fixing elements are contained in the scope of delivery.
Profile section wide 321–350 mm
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
Type Model no. Construction width
DF-SG8 541 82 cm
DF-SG9 549 89.5 cm
General notes
With the simultaneous operation of firing (e.g. wood, gas, oil or coal-fired heating systems), safe operation is only possible
providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the appliance. Risk of toxic fumes!
An adequate flow of fresh air must be guaranteed, e.g. via non-closable openings in doors and windows and combined with
ventilation wall bricks for incoming and exhaust air or by other technical means.
If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the minimum distances (see
Dimensions) must be adhered to.
Efficient repairs can only be guaranteed if it is possible to disconnect the appliance at any time without causing any damage.
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other fuels.
Always observe the local fire regulations.
Installation accessories supplied
Profile
section
Type Width Wall unit depth Article no.
Nero White ChromeClass AluClass
wide DF-SG8 821 321–350 mm H4.2288 H4.2289 H4.2290 H4.2291
wide DF-SG9 896 321–350 mm H4.2292 H4.2293 H4.2294 H4.2295
1
2
3
500
400
300
200
100
0
0 100 200 300 400
500 600
40
30
20
10
0
50
Air circulation rate [m
3
/h]
p
stat
[mm WS/CE]
p
stat
[P
a
]
75
821/896
26
Installation instructions
Range hood DF-SG8 / DF-SG9
Built-in range hood
J541.53-1
13.12.13 FUW
2
Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
Application height of the appliance: up to max. 2000 m above sea level
Distance above hob
Electrical connections
Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage
installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
Voltage Rated load Fuse Mains cable
230 V~ 50 Hz 316 W 10 A 1.2 m with «type 12» plug
Dimensions
Use of stone cladding
20 mm thick wall panels (granite,
marble) with a chamfer are possible.
Minimum distance B
For electric hob: min. 600 mm
For gas hob: min. 750 mm
If the installation instructions for the gas hob stipulate a larger distance, this must be observed.
190
210
357
3016
821/896
Finished profile
823/898
Substructure
ø 120
B
825/900
552
192
330
min. 200
ø 150
321–350
820/895
max. 155
32
Reduction connection
max. 525
20
Installation instructions
Range hood DF-SG8 / DF-SG9
Built-in range hood
J541.53-1
13.12.13 FUW
3
The following possibilities exist if the appliance is to be used in the recirculation mode:
Using an activated charcoal filter mounted directly in the appliance
Here, the extracted air flows through and out the exhaust air connection and has to be blown back into the room through a ventilation
grille in the ceiling cover.
Using an LRC air recycling cassette (see H4.0830)
Here the activated charcoal filter is placed in the air recycling cassette. The extracted air flows through the exhaust air connection and
an air extraction duct into the cassette and is then blown back through the air outlet grille into the room.
Recirculation mode
The cross-sectional area (air outlet area) of the ventilation grille must be at least 200cm².
Installation instructions
Range hood DF-SG8 / DF-SG9
Built-in range hood
J541.53-1
13.12.13 FUW
4
1. Mount exhaust air connection A and seal B to fan box C with pan head screws.
2. Mount suspension bracket D on left/right to fan box C with spacers E and pan head screws F
and set a distance of 23 mm from rear panel. Only lightly tighten the pan head screws F.
3. Remove grease filter G.
4. Drill holes for rawl plugs H on left/right in rear panel and fix retainer hooks I with countersunk
head screws J.
5. Push fan box C into niche until suspension brackets D left/right can be pushed over retainer
hooks I. Tighten the pan head screws F.
6. Set the wall unit depth (pull substructure K forward or push it back) and tighten screws L left/
right.
Set horizontal position with adjuster screws M left/right.
7. Fix range hood additionally to the wall unit with screws N.
Fix metal ring O (ø 150 mm) to exhaust air connection and mount the venting hose P.
A reduction connection Q can be used if required.
Installation
min. 600
2050
from floor
180
~402
46
L L
Y
230 V
Deflector plate
X
ø 150
330
130
max. 525
ø 150
ø 154
ø 124
ø 118
Reduction connection
Iron ring
536
552
Niche: 825/900
30
32
Front: 820/895
Substructure: 823/898
Finished profile: 821/896
===
min.
200
110
46
Hob
1920–8
C
G K
330
Front
(adjustable: 321–350)
O
A
Q
O
B
N
P
F
E
H
J
I
D
Detail Y
Detail X
23
I M F
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

V-ZUG 549 Installation guide

Category
Cookers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI