V-ZUG 384 Installation guide

Category
Cooker hoods
Type
Installation guide
Installation instructions
Range hood DF-SLG5 / DF-SLG6
Built-in range hood
Operating modes: extracted air / recirculation air
J377.113-1
6.1.14 FUW
1
These installation instructions apply to the models:
377 (DF-SLG5, construction width 55 cm)
384 (DF-SLG6, construction width 60 cm)
Identification plate
A Remove grease filter. The identification plate is on the inside of the appliance.
Supplied installation accessories
All fixing elements are contained in the scope of delivery.
Extraction mode
Recirculation mode
The following possibilities exist if the appliance is to be used in recirculation mode:
Using an active carbon filter mounted directly in the appliance (see J415.48)
In this application the extracted air flows through the exhaust air connection, from where it is blown out and is then blown back into the
room through a ventilation grille in the ceiling cover.
Using an air recycling cassette LRC1 (see H4.0830)
In this application the active carbon filter is installed in the air recycling cassette. The extracted air flows through the exhaust air
connection and an exhaust air conduit, into the cassette and is blown back into the room through the air discharge grille.
A Information on the necessary mains voltage, type of current and fuse protection can be taken from the identification plate.
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
General notes
With the simultaneous operation of firing (e.g. wood, gas, oil or coal-fired heating systems), safe operation is only possible pro-
viding a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the appliance. Risk of toxic fumes! An
adequate flow of fresh air must be guaranteed, e.g. via non-closable openings in doors and windows and combined with ven-
tilation wall bricks for incoming and exhaust air or by other technical means.
If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the minimum distances (see
«Dimensions») must be adhered to.
Efficient repairs can only be guaranteed if it is possible to disconnect the appliance at any time without causing any damage.
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other fuels.
Always observe the fire regulations.
The cross-section area (air discharge surface area) of the ventilation grille must be at least 200 cm².
Electrical connections
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low
voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
Installation instructions
Range hood DF-SLG5 / DF-SLG6
Built-in range hood
Operating modes: extracted air / recirculation air
J377.113-1
6.1.14 FUW
2
Options
Profile Type Width Wall unit depth Art. no.
narrow
DF-SLG5 546 mm
280–315 mm H4.1752
wide 320–350 mm H4.1753
narrow
DF-SLG6 596 mm
280–315 mm H4.1754
wide 320–350 mm H4.1755
Included in the scope of delivery: H4.1753 / H4.1755 Available as option: H4.1752 / H4.1754
Dimensions
Reduction connection
Metal ring
Use of stone claddings
Wall panel (granite, marble) with 20 mm
thickness.
* With metal ring: 170 mm
Distance above hob
Minimum height B:
For electric hob:
For gas hob:
min. 600 mm
min. 750 mm
70
546/596
75
70
546/596
37,5
330
min. 200
192
130 *
357
16
max. 525
280–350
73
550/600
545/595
502/552
14–175
210
B
ø 120
ø 150
Reduction connection
546/596
Finished profile
548/598
Substructure
ø 154
ø 124
ø 118
110
ø 150
60
40
20
Installation instructions
Range hood DF-SLG5 / DF-SLG6
Built-in range hood
Operating modes: extracted air / recirculation air
J377.113-1
6.1.14 FUW
3
Indications
A Avoid routing the exhaust air pipeline to the side.
A All plastering, plasterboarding, wall papering or painting work is to be carried out prior to the installation.
Installation
330
Front
(adjustable: 280–350)
Hob
Finished profile:
Niche:
Substructure:
Front:
545/595
548/598
546/596
502/552
R
C
550/600
min. 600
X
Y
330
min. 200 130
ø 150
S6
S5
35–43
0–8
124
192
155
S4
S9
35736
max. 525
34 340
Z
S4S4
S4S4
560
596
600
546
550 ±0,5
502
548
550 ±0,5
552
558
560
600 ±0,5
Size system 55 cmSize system 55 cm Size system 60 cmSize system 60 cm
Detail X
Detail Y
23
adjust
3
adjust
S3
S5, S6
EE
S3
S5, S6
Detail Z
S7
Installation instructions
Range hood DF-SLG5 / DF-SLG6
Built-in range hood
Operating modes: extracted air / recirculation air
J377.113-1
6.1.14 FUW
4
Installation
1. Mount a suitable finished profile A to the fan box B with screws S1
(ø 3 × 13 mm).
2. Mount exhaust air connection C and seal D to the fan box B with
screws S2 (ø 3,5 × 9 mm).
3. On both sides, mount angle bracket E to the fan box B with screws S3
(ø 3,5 × 13 mm) and set the following distance (see Detail X):
for construction width 55 cm: 23 mm
for construction width 60 cm: 3 mm
4. On both sides, punch holes for screws S4, S5, S6 (using the enclosed
paper template).
5. Push fan box B into niche and screw firmly to the wall unit left/right
with screws S4 (ø 4,5 × 30 mm) and S5, S6 (ø 4,5 × 15 mm).
6. Set the distance to the rear panel with the two adjuster screws S7
(see Detail Z).
7. Check correct position of cover strip H. Take care not to trap it on
assembly!
8. For recirculation mode:
Mount fixture for recirculation filter (see J415.48) and insert filter.
9. Place substructure J on fan box B (rail profile left/right) and push
it carefully over finished profile A. Maintain a minimum distance of
2 mm between finished profile A and wall unit to ensure that the
substructure can be pushed smoothly in place.
10. Set the wall unit depth (pull substructure J forward or push it back)
and tighten screw S8 left/right.
11. Establish electrical connections K (lighting) and L (control unit); note
the coding.
12. Screw range hood additionally to the wall unit with screws S9
(ø 3 × 13 mm).
13. Establish electrical connection (see section «Electrical connections»).
14. Fix metal ring R (ø 150 mm) to exhaust air connection and mount the
venting hose. A reduction connector can be used where required.
A
2
2
S7
J
H
S8
B
S9
K
L
S9
S1
S2
C
D
A
B
E
S3
S1
S7
S7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

V-ZUG 384 Installation guide

Category
Cooker hoods
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI