Installation instructions
Range hood DF-SG5 / DF-SG6
Built-in range hood
J359.53-1
12.12.13 FUW
1
These installation instructions apply to:
Extraction mode
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
Type Model number Construction width
DF-SG5 359 55 cm
DF-SG6 360 60 cm
General notes
With the simultaneous operation of firing (e.g. wood, gas, oil or coal-fired heating systems), safe operation is only possible
providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the appliance. Risk of toxic fumes!
An adequate flow of fresh air must be guaranteed, e.g. via non-closable openings in doors and windows and combined with
ventilation wall bricks for incoming and exhaust air or by other technical means.
If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the minimum distances (see
Dimensions) must be adhered to.
Efficient repairs can only be guaranteed if it is possible to disconnect the appliance at any time without causing any damage.
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other fuels.
Always observe the local fire regulations.
Identification plate p-V diagram
The identification plate is located on the inside of the appliance.
Installation accessories supplied
All fixing elements are contained in the scope of delivery.
1
2
3
500
400
300
200
100
0
0 100 200 300 400
500 600
40
30
20
10
0
50
Air circuit rate [m
3
/h]
p
stat
[mm WS/CE]
p
stat
[P
a
]
Installation instructions
Range hood DF-SG5 / DF-SG6
Built-in range hood
J359.53-1
12.12.13 FUW
2
Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
Application height of the appliance: up to max. 2000 m above sea level
Accessories
Profile
section
Type Width Wall unit depth Article no.
Nero White ChromeClass AluClass
narrow
DF-SG5 546 mm
280–300 mm H4.2215 H4.2219 H4.2223 H4.2227
medium 290–320 mm H4.2216 H4.2220 H4.2224 H4.2228
wide 321–350 mm H4.2275 H4.2276 H4.2277 H4.2278
narrow
DF-SG6 596 mm
280–300 mm H4.2217 H4.2221 H4.2225 H4.2229
medium 290–320 mm H4.2218 H4.2222 H4.2226 H4.2230
wide 321–350 mm H4.2279 H4.2280 H4.2281 H4.2282
Narrow profile section 280–300 mm available as option Medium profile section 290–320 mm available as option
Wide profile section 321–350 mm included in scope of delivery
Electrical connections
Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage
installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
Voltage Rated load Fuse Mains cable
230 V~ 50 Hz 316 W 10 A 1.2 m with «type 12» plug
26
546/596
37,5
26
546/596
44
26
546/596
75
Installation instructions
Range hood DF-SG5 / DF-SG6
Built-in range hood
J359.53-1
12.12.13 FUW
3
Distance above hob
The following possibilities exist if the appliance is to be used in the recirculation mode:
Using an activated charcoal filter mounted directly in the appliance
Here, the extracted air flows through and out the exhaust air connection and has to be blown back into the room through a ventilation
grille in the ceiling cover.
Using an LRC air recycling cassette (see H4.0830)
Here the activated charcoal filter is placed in the air recycling cassette. The extracted air flows through the exhaust air connection and
an air extraction duct into the cassette and is then blown back through the air outlet grille into the room.
Dimensions
Use of stone cladding
20 mm thick wall panels (granite,
marble) with a chamfer are possible.
Minimum distance B
For electric hob: min. 600 mm
For gas hob: min. 750 mm
If the installation instructions for the gas hob stipulate a larger distance, this must be observed.
Recirculation mode
The cross-sectional area (air outlet area) of the ventilation grille must be at least 200cm².
190
357
3016
B
550/600
502/552
192
330
min. 200
max. 525
280–350
546/596
max. 155
32
210
ø 120
ø 150
548/598
Construction width for
guide profile
Reduction connection
20
Installation instructions
Range hood DF-SG5 / DF-SG6
Built-in range hood
J359.53-1
12.12.13 FUW
4
Installation
1. Mark holes A, B, C on both sides using the paper template
supplied.
2. Screw angle bracket D to both sides of housing and set
distance as follows:
for construction width 55 cm: 23 mm
for construction width 60 cm: 3 mm
3. Remove grease filter E.
4. Push range hood into niche and screw on left/right to side
panels using the screws supplied:
A with screws ø 4.5 × 35 mm
B, C with screws ø 4.5 × 15 mm.
5. Mount exhaust air connection G and seal Z to housing. With
exhaust air duct of ø 150 mm, fix metal ring R to exhaust air
connection G and mount the venting hose H. A reduction
connection J can be used if required.
6. Adjust screws F left/right for front alignment (flushness) of
deflector plate (corresponding to depth of unit).
7. Mount grease filter E.
H
G
J
Z
R
46
230 V
180
330
min. 200
130
ø 150
35
124
0–8
192
155
340
34
357
330
32
46
ø 154
ø 124
ø 118
110
502/552
X
Y
A
A
C
B
A
FF
EF
2050
from floor
min. 600
Niche
550/600
Front
546/596
max. 525
Deflector
plate
Hub
Guide profile
548/598
Reduction connection
ø 150
Iron ring
Front
(adjustable: 280–350)
D
B, C
D
B, C
A
F
F
A
560
502
548
550 ±0,5
23 (adjust)
558
560
600 ±0,5
3 (adjust)
552
546
550 ±0,5
596
600 ±0,5
Detail Y
Size system 55 cm Size system 60 cm
Detail X
Size system 55 cm Size system 60 cm
/