V-ZUG 34006 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the V-ZUG 34006 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation instructions
Warming drawer 60-283
J34006.113-0
18.7.12 FUW
1
These installation instructions apply to the model: 34006
Identification plate
A Remove the drawer. The identification plate is located on the left-hand side next to the dial.
Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
Application height of the appliance: up to max. 2000 m above sea level
1. Fix a bracket set 60 (not included in the scope of delivery) for an
appliance located above or below.
2. Place appliance in front of the niche and connect mains cable.
3. Carefully slide appliance into the niche until it is flush with the front
of the cabinets, ensuring that the mains cable is not pinched.
4. Open the drawer and fix in place from the front, using the 4 supplied
screws A.
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
General notes
If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be strict-
ly observed.
Electrical connections
Electrical connections must made by qualified personnel in accordance with the guidelines and standards for low voltage in-
stallations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
Installation
The drawer must be secured by 4 screws to prevent tipping.
Ensuring that the mains cable is not pinched. After installation, the mains cable must not touch the back and the bottom of the
appliance.
A
Installation instructions
Warming drawer 60-283
J34006.113-0
18.7.12 FUW
2
Built-in solo
Installing with oven
min. 550
283
560–568
596
547
281
600
598281
596
547
600
min. 550
560–568
877
594
X
567
Detail X
594
Niche
598
Appliance
/