The Kichler Lighting 52234BK is a versatile light fixture compatible with various ceiling types and bulb options. It features adjustable arms, a chain for height adjustment, and a threaded pipe for secure mounting. The fixture can accommodate multiple bulbs, allowing for customized lighting levels. With its classic design, it's suitable for both residential and commercial spaces, adding a touch of elegance to any room. Installation requires basic electrical knowledge and should be performed by a qualified electrician to ensure safety and proper functioning.

The Kichler Lighting 52234BK is a versatile light fixture compatible with various ceiling types and bulb options. It features adjustable arms, a chain for height adjustment, and a threaded pipe for secure mounting. The fixture can accommodate multiple bulbs, allowing for customized lighting levels. With its classic design, it's suitable for both residential and commercial spaces, adding a touch of elegance to any room. Installation requires basic electrical knowledge and should be performed by a qualified electrician to ensure safety and proper functioning.

IS-52234-US
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Rotate xture arms into their correct posions as shown (Figure 1).
2) Pass xture wire from main frame[I] through large loop[J].
3) Screw large loop onto threads protruding from top of main frame.
4) Take threaded pipe[L] from parts bag and screw in screw collar loop[B] a minimum
of 6 mm (1/4”). Lock into place with hexnut[C].
5) Run another hexnut down threaded pipe almost touching rst hexnut. Now screw
threaded pipe into mounng strap[D]. Mounng strap must be posioned with
extruded thread faced into outlet box[E]. Threaded pipe must protrude out the back
of mounng strap. Screw third hexnut onto end of threaded pipe protruding from
back of mounng strap.
6) Connect mounng strap[D] to outlet box using the strap mounng screws[K].
7) Unscrew the threaded ring[F] from screw collar loop. Take canopy[G] and pass over
screw collar loop. Approximately one half of the screw collar loop exterior threads
should be exposed. Adjust screw collar loop by turning assembly up or down in
mounng strap. Remove canopy.
8) Aer desired posion is found, ghten both top and boom hexnuts up against the
boom and top of the mounng strap.
9) Slip canopy over screw collar loop and thread on threaded ring.
10) Aach one end of chain[H] to boom of screw collar loop[B] by spreading end link
and then closing the link. Aach opposite end of chain to large loop[J] by spreading
opposite end link and then closing the link. To close the open chain links, place a piece
of cloth over the open link and use a pair of pliers to gently squeeze the link closed.
11) Unscrew threaded ring[F], let canopy[G] and threaded ring slip down.
12) Weave electrical wire and ground wire through chain links[H] no more than 3 inches
apart. Pass wire through screw collar loop[B], threaded ring[F], canopy[G], threaded
pipe[L], and into outlet box[E].
13) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw, and
thread into hole.
b) On xtures where a cupped washer is provided, aach ground wire from outlet
box under cupped washer and green ground screw, then thread into mounng
strap.
If xture is provided with ground wire, connect xture ground wire to outlet box
ground wire with wire connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
14) Make wire connecon. Reference chart below for correct connecons and wire
accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply Wire
to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other than
green) with silver conductor
*Note: When parallel wire (SPT 1 &
SPT 2) are used. The neutral wire
is square shaped or ridged and the
other wire will be round in shape or
smooth (See illus.)
Neutral Wire
15) Raise canopy to ceiling.
16) Secure canopy in place by ghtening threaded ring onto screw collar loop.
17) Slip one cup[M] down over end of threaded tube[N]. Screw threaded tube into
boom of coupling[A] in the center of socket cluster.
18) Screw hexnut[O] on threaded tube up against boom of coupling.
19) Slip decorave tube[P] over threaded tube. Slip other cup[M] over end of threaded
tube, up against decorave tube.
20) Slip steel washer[Q] over end of threaded tube, up against boom of cup.
21) Slip rubber washer[R] onto end of threaded tube, up against steel washer.
22) Li glass[S] over end of threaded tube, up against rubber washer. Slip another steel
washer[Q] over threads protruding out boom of glass and screw hexnut[O] onto
threads to secure.
23) Slip trim piece[T] over threads protruding below hexnut, making sure threads pass
through center hole in trim piece.
24) Screw nial[U] onto threads protruding out boom of trim piece to secure trim
piece.
25) Install the recommended bulbs (not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before starng and
during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical Code
(NEC) and all local code specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a so damp cloth should be used. Harsh cleaning products may damage
the nish.
Installaon Instrucons
[A] Coupling
[B] Screw Collar Loop
[C] Hexnut
[D] Mounting Strap
[E] Outlet Box
[F] Threaded Ring
[G] Canopy
[H] Chain
[I] Main Frame
[J] Large Loop
[K] Strap Mounting
Screws
[L] Threaded Pipe
[M] Cup
[N] Threaded Tube
[O] Hexnut
[P] Decorative Tube
[Q] Steel Washer
[R] Rubber Washer
[S] Glass
[T] Trim Piece
[U] Finial
Figure 1
H
B
G
E
D
C
K
L
F
J
I
M
N
P
M
Q
R
Q
O
T
U
O
S
A
  • Page 1 1
  • Page 2 2
  • Page 3 3

Kichler Lighting 52234BK User manual

Type
User manual

The Kichler Lighting 52234BK is a versatile light fixture compatible with various ceiling types and bulb options. It features adjustable arms, a chain for height adjustment, and a threaded pipe for secure mounting. The fixture can accommodate multiple bulbs, allowing for customized lighting levels. With its classic design, it's suitable for both residential and commercial spaces, adding a touch of elegance to any room. Installation requires basic electrical knowledge and should be performed by a qualified electrician to ensure safety and proper functioning.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI