MMT2
2/2 50.0051.01.00
CONNECTING THE MMT2
To carry out the connection of this module you should follow the steps indicated in the figure on next page:
Choose an operating mode with the jumper marked with nr.1: This module can operate respecting the priority and zone
system (ALAR) or as BGA.
ATTENTION: You can have only one module acting as BGA. Remember that to work in this operating mode, you must
remove all zone assignment and priority jumpers.
If you decide the module to work in ALAR. mode, select now its priority. To do that, you will have to place two PRIORITY
jumpers according to the priority you wish this module to have. (indication nr.2 of the figure on next page). For example:
To set the priority to 3, place the two jumpers at positions J112 and J115.
ATTENTION: There can only be one module with Priority 1. Remember that every module containing
PRIORITY
information must be mounted on the same chassis.
If you configure the module to operate in ALAR. mode, define now the zone or zones to which the message has to be sent
by means of the jumpers indicated with nr.3. For example: If you wish the module to act in zones 3 and 5, insert two
jumpers at position J118 and J121.
Set the input sensibility of the XLR-3 connector with the jumpers indicated with nr. 4: ATT: -30dBV / 1K8 NOT ATT: -
50dBV / 1K8 and LINE: -10dBV / 1K8.
Use the following table, where X means that the jumper is inserted.
LINE J105 MIC J106 LINE J107 MIC J108 MIC ATT J109
LINE X - X - -
MIC - X - X -
MIC ATT - X - - X
If you are going to use a microphone that requires Phantom power, insert a jumper in the position indicated with nr. 5.
When inserted, the phantom power is enabled; when not, it is disabled.
Choose whether the module should activate using the
Voice Over
function or not. For that purpose, set the jumper
indicated with nr.6 to ON or OFF.
ATTENTION: This Jumper must be set either ON or OFF. The module would otherwise not operate correctly.
Insert and screw the module and the chassis together in the front and back panels.
Connect the data buses (Flat 10- and 20-way cables) to the connectors marked with nr. 7 in the next figure.
Link together the front and back panel. In this case you will have to connect following connector pair marked with nr. 8:
J120-WI101.
Once the complete installation of one or various chassis and the peripherals connections to ENVIRO has been carried out,
you should adjust the volume of this module so that the SIGNAL LEVEL LED lights up green while talking normally. As the
final step in the modules configuration, you may wish to adjust the tone controls.
MMT2 MODULE
J101
1
WI1 0 1
J120
1
On Off
VO I C E- O VER
J126
ALAR.
J138
J104
BGA
J131
J105
J107
LI N E
MIC
MIC ATT
J108
J109
J106
LI NE
MIC ATT
MIC
PHANTOM
J129
J130
J124
J125
101112
ZO N E
9 8
J121
J123
J122
57 6
123
J157
J112
J119
J118
J116
J117
ZO N E
4 3 12
J111
J113
J115
J114
J110
PRI O RI TY
R143 R156 R1 62R14 4
S102
J133
D127
D120
D128
PRIORITIES:
Priority 1: J110-J113
Priority 2: J111-J114
Priorit
3: J112-J115
3
2
1
4
5
6
8