Altair EF-200 Owner's manual

Type
Owner's manual
EF- 2 0 0
DUAL CHANNEL MASTER STATION
E- 2 0 0 SERI ES I N TERCO M SYST EM
OWNERS MANUAL
AUDIO ELECTRONICS DESIGN
AUDI O ELECTRONI CS DESI GNAUDI O ELECTRONI CS DESI GN
AUDI O ELECTRONI CS DESI GN
EQUIPOS EUROPEOS ELECTRÓNICOS, S.A.L
Avda. de la Industria, 50. 28760 TRES CANTOS-MADRID (SPAIN).
34-91-761 65 80 34-91-804 43 58 altair@altairaudio.com
www.altairaudio.com
Downloaded from www.Manualslib.com manuals search engine
2
E- 2 0 0 SER I ES I N T ERC O M SYS TEM
E
F
-200 DUAL CHANNEL MASTER STATION
1. I N T RO D U CT I O N .................................................................................................................................................................................. 3
2. SWITCHES, CONTROLS, ADJUSTMENTS AND CONNECTORS.................................................................................................... 4
FRON T PAN EL ...................................................................................................................................................................................4
REA R PA N EL ...................................................................................................................................................................................... 5
3. WORKING PRECAUTIONS................................................................................................................................................................ 6
4. INSTALLATION ...................................................................................................................................................................................6
UNPACKING .....................................................................................................................................................................................6
MOUNTING....................................................................................................................................................................................... 6
CHANGING THE FUSE.....................................................................................................................................................................6
CONNECTING TO THE M AINS........................................................................................................................................................ 7
EM ER G EN C Y B A T TER Y PL A CEM EN T .............................................................................................................................................. 7
PROGRAM INPUT CONNECTION ................................................................................................................................................... 7
UNBALANCED INPUT:
..................................................................................................................................................................8
BALANCED INPUT:
.......................................................................................................................................................................9
PA OUTPUT CONNECTION .............................................................................................................................................................9
UNBALANCED OUTPUT:
.............................................................................................................................................................10
BALANCED INPUT:
...................................................................................................................................................................... 11
PA OUTPUT RELAY CONNECTION ................................................................................................................................................ 11
EX T ER N A L U N I TS C O N N EC T I O N ...................................................................................................................................................12
MULTICHANNEL SYSTEM CONNECTION (MASTER-SLAVE).......................................................................................................13
CONNECTION OF INTERCOM SYSTEM S WITH M ORE THAN 5 0 BELTPACKS.........................................................................15
5. OPERATION.......................................................................................................................................................................................15
HEADSET CONNECTION.................................................................................................................................................................15
HEADSET VOLUME CONTROL.......................................................................................................................................................16
PA- M IC OUTPUT + RELAY CONTROL SWITCH ...........................................................................................................................16
BU Z Z ER ON / OFF SW ITCH ..............................................................................................................................................................16
REM O TE M U TE A LL M I C S AN D BU Z Z ER SW I TC H ES ..................................................................................................................17
CALL SWITCH...................................................................................................................................................................................17
MIC ON/OFF/PUSH TO TALK SWITCH.........................................................................................................................................17
SIDETONE CONTROL.......................................................................................................................................................................18
LI N E A A N D B LI S TEN BA LA N CE C O N TRO L .................................................................................................................................18
PROGRAM INPUT LEVEL CONTROL..............................................................................................................................................18
PROGRAM SENDING TO LINES A/ B SWITCHES .........................................................................................................................18
PROGRAM TO H EADPHONES CONTROL....................................................................................................................................18
LI N ES A A N D B LI N K S W I TCH ........................................................................................................................................................18
SLAVE CHANNELS LINK SWITCH ..................................................................................................................................................19
EM ER G EN C Y SW I TC H ( BA T TERY O PERA T I O N ) ............................................................................................................................19
6. OPTIONS............................................................................................................................................................................................19
PROGRAM INPUT TRANSFORM ER (IT- DA) ..................................................................................................................................19
PA OUTPUT TRANSFORM ER (OT- DA) ..........................................................................................................................................19
SECURITY COVER (TP- 1)..................................................................................................................................................................19
KEY LOCKED SECURITY COVER (TS- 1) ..........................................................................................................................................19
7. SPECIAL OPERATIONS.....................................................................................................................................................................20
PROGRAM INPUT TRANSFORM ER (IT- DA) .................................................................................................................................20
OUTPUT TRANSFORMER (OT- DA)................................................................................................................................................20
OPENING THE INTERCOM LINE TERMINAL IMPEDANCE...........................................................................................................21
CHANGING THE M IC GAIN ...........................................................................................................................................................21
PA OUTPUT CONFIGURATION ......................................................................................................................................................21
ACTIVATING THE M ICROPHONE PHANTOM POWER..............................................................................................................22
PROGRAM INPUT CONFIGURATION IN A M ULTICHANNEL SYSTEM (M ASTER- SLAVE) ......................................................22
CHANGING THE BUZZER LEVEL...................................................................................................................................................23
PROGRAM INTERRUPT WITH THE PA- M IC SWITCH CONFIGURATION .................................................................................23
CONFIGURATION OF THE M ULTIPURPOSE RELAY ACTIVATION ............................................................................................23
PROGRAM INTERRUPT WITH THE M IC SWITCHES CONFIGURATION ...................................................................................24
8. BLOCK DIAGRAM AND HOW IT WORKS.....................................................................................................................................25
9. REPAIR GUIDE..................................................................................................................................................................................27
10 . A P P LI C A T I O N EX A M P LE................................................................................................................................................................28
11. T EC H N I C A L S P EC I F I C AT I O N S ........................................................................................................................................................29
12 . W A RRAN T Y .....................................................................................................................................................................................30
Downloaded from www.Manualslib.com manuals search engine
3
E- 2 0 0 SER I ES I N T ERC O M SY ST EM
E
F
-200 DUAL CHANNEL MASTER STATION
1. I N T RO D U C T I O N
Cong ratulation s on your p urcha se of th e ALTAIR dual channel master station EF - 2 0 0 of the
E- 2 0 0 series intercom system. There is a lot the characteristics that make of the ALTAIR E- 2 0 0 series
one of the most highlighted in the audio professional market, some are enumerated here:
The new ALTAIR E-200 SERIES add more features to our popular Espiral E-100 series, maintaining
compatibility. All the components in the system incorporate a microcontroller to implement different
tasks as Mic Killer, Remote all Buzzer switch-off, Mic Switch Latch or Push To Talk, Program Interrupt,
etc.
Re m o t e A l l M i c s w i t c h - o f f h e l p s t h e o p e r a t o r t o m a i n t a i n a l o w e r n o i s e c o n v e r s a t i o n i n n o i s y
environments. Also implemented is the remote All Buzzers switch-off feature to avoid undesired
audible CALL signalling during performances.
Th e M a s t e r St a t i o n u n i t p o w e r s a l l t h e Sy s t e m c o m p o n e n t s a n d i n c o r p o r a t e s n e w s p e c i a l f e a t u r e s
as System Expandability or Battery Operation.
System Expandability permits creating a multichannel (4, 6, or more channels) Intercom System by
using more Master Stations in a daisy chain arrangement. This feature enables freedom in the System
design and in-site future upgrades. Rental companies can benefit with lower component inventories.
Our new internal Battery operation permits short-time communications in difficult situations (= no
Po w e r ) o f e m e r g e n cy.
The ALTAIR EF-200 unit incorporates an internal worldwide voltage operation power supply that
powers all the system. In case of a short circuit on any point of the line, the unit shuts down with
automatic and instantaneous reset.
Befo r e b eg inn ing i t is i m p o r ta nt to r ea d this m a nu a l. Th is m anua l w ill h el p you to i nsta ll a nd use
your new intercom master station. It is very important to read it carefully, mainly the paragraphs
marked as NOTE, PRECAUTION and DANGER, for your security.
Sa v e t h e o r i g i n a l p a c k i n g , y o u c a n r e - u s e i t t o t r a n s p o r t t h e u n i t . NEVER SHIP THE ALTAIR EF-200
WITHOUT ITS ORIGINAL PACKING.
Downloaded from www.Manualslib.com manuals search engine
4
E- 2 0 0 SER I ES I N TER CO M SYS TEM
E
F
-200 DUAL CHANNEL MASTER STATION
2. SWITCHES, CONTROLS, ADJUSTMENTS AND CONNECTORS
These are the switches, controls, adjustments and connectors that you can find in your ALTAIR intercom master station. The description and
explanation of each one will be found in the corresponding section.
FRO N T PA N EL
CALL SWITCH.
HEADSET CONNECTOR.
MIC ON/ OFF/PUSH TO TALK SWITCH.
SI D ETON E CON TROL.
HEADSET VOLUME CONTROL.
LIN E A A N D B LI STEN B A LA N C E C O N TROL.
PA - M IC OU TPUT + RELAY CON TROL SWITCH.
PROGRA M IN PUT LEVEL CON TROL.
BUZZER ON/ OFF SWITCH.
PROGRA M SEN DIN G TO LIN ES A/ B SWITCHES.
REM OTE M U TE A LL M I C S A N D B U Z Z ER SW ITCH ES. P RO G RA M TO H EA DP H O N ES C O N TRO L.
Downloaded from www.Manualslib.com manuals search engine
5
E- 2 0 0 SER I ES I N TER CO M SYS TEM
E
F
-200 DUAL CHANNEL MASTER STATION
LIN ES A A N D B LI N K SW ITC H . EM ERG EN C Y SW I TC H ( B A TTERY OP ERA TI O N ) .
SLA VE C H A N N ELS LI N K SWI T C H .
POWER SWITCH.
REA R PAN EL
MAINS CONNECTOR AND FUSEHOLDER. PA OUTPUT CONNECTOR XLR-3-32.
BATTERY HOLDER. PA OUTPUT RELAY CONNECTOR JACK ¼ ” .
PROGRA M INPUT M IC/ LINE SELECTOR SWITCH. INTERCOM LIN E CON NECTORS XLR- 3 - 3 1 A ND
XLR-3-32.
PROGRA M IN PUT CONNECTOR XLR- 3 - 3 1.
MULTICHANNEL LINKS CONNECTORS FCC-68.
Downloaded from www.Manualslib.com manuals search engine
6
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
3. WORKING PRECAUTIONS
Th e m a n u f a c t u r e r i s n o t r e s p o n s i b l e o f a n y d a m a g e t h a t c a n p o s s i b l y h a p p e n t o t h e i n t e r c o m
master station outside the limits of the warranty or those produced by not taking care with the
working precautions.
Mains voltage must be between the limits of the admitted power supply (90-264 VAC, 50-
60 Hz) and that the fuse must be the appropriate (2A slow blow type: T2A). Damage caused
by connection to improper AC voltage is not covered by any warranty.
DANGER: Inside the unit there are high voltages, do not open it. The unit does not
contain elements that could be repaired by the user. Whenever the intercom master
station is connected to the mains, it carries elements with high voltages. In order to
disconnect the unit completely, you must disconnect it from the mains.
CAUTION: Protect the unit from the rain and moisture. Ensure that no objects or liquids enter it. If
liquid is spilled into the unit, disconnect it from the mains and consult a qualified service technician.
Do not place the unit close to heat sources.
4. INSTALLATION
UNPACKING
Before leaving the factory, each intercom master station has been carefully inspected and
tested. Unpack and inspect the unit for any damage that may have occurred during shipment. If
any damage is found, does not connect the unit to the mains; notify the salesperson immediately;
a qualified service technician should inspect the unit.
Save the original packing, you could use if you need to transport the unit. NEVER SHIP THE
INTERCOM MASTER STATION WITHOUT ITS ORIGINAL PACKING.
MOUNTING
It is always recommended to mount the unit in rack, either for mobile or fixed installations, for
protection, safety, aesthetics, etc.
The ALTAIR EF-200 is designed for standard 19" rack mounting, and takes up 1u high rack
space.
CHANGING THE FUSE
This unit incorporates an internal, worldwide voltage operation power supply, and it is
prepared to work from 90 to 264 VAC, 50-60Hz.
Make sure that the unit is disconnected from the mains.
In the unit rear panel are placed the mains connector, the mains selector
and the fuse holder. The box bellow this mains connector is called fuse holder.
Ta k e o u t t h e f u s e h o l d e r .
After extracting the fuse holder, the fuse will appear, take out it and change
for the new one.
Insert the fuse holder into the mains connector again.
Downloaded from www.Manualslib.com manuals search engine
7
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
Make sure that the fuse is the right one: 2A slow blow type - T2 A
CAUTION: Always make sure after changing the fuse, that it is the right one.
CONNECTING TO THE M AINS
The connection of the intercom master station power supply to the mains takes
place by a standard cord included in the box.
Make sure that the unit power switch is at 0 position (turned off).
Insert the fema le I.E.C. connector of the tripola r cable into the unit power supply
male connector, placed at the rear panel.
Insert the male connector of the tripolar cable into the mains plug.
Tu r n o n t h e u n i t p o w e r s w i t c h . In t h a t m o m e n t t h e C A LL LED i n d i c a t o r
will light slightly, indicating that the unit is turned on.
CAUTION: Make sure that the mains voltage is the correct as well as their fuse is the right one.
EM ERG EN C Y B A TT ER Y PLA C EM EN T
The central unit has a lodging for a 9VDC battery (6LR61 type) located in the rear panel, that
allows the system operation in no power difficult situations during a short period of time. The use of
alkaline batteries is recommended.
Make sure that the unit power switch is at 0 position (turned
off).
In the unit rear panel is placed the battery holder. Take out
the battery holder, pushing up and toward you with a coin
Insert the battery into the battery holder, taking into account
the polarity that comes indicated inside the battery holder.
Insert the battery holder into its rear panel plastic box.
NOTE: The battery power has an internal fuse, located inside the unit, in order to protect the unit of
excessive currents in the battery. If it is necessary to change the fuse, make sure that the device is
disconnected from the mains, and open the top cover according to the indications of the section
special operations. The fuse is placed in the top right corner, just beside the battery holder. After
changing make sure that it is the adequate T1A (1 ampere, slow blow type).
PROGRAM INPUT CONNECTION
Th e i n t e r c o m m a st e r s t a t i o n p r o g r a m i n p u t s i g n a l i s c a r r i e d o u t t h r o u g h a X LR- 3 - 3 1 f e m a l e
connector. The input connection is balanced, with a nominal impedance of 40 K (20 K
Downloaded from www.Manualslib.com manuals search engine
8
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
unbalanced). The next list shows the input pins correspondence as A.E.S recommends:
PROGRAM INPUT - XLR- 3 - 3 1
PIN 1
0 V
PIN 2 HOT (+ )
PIN 3
COLD (- )
Th e i n p u t c o n n e c t i o n d e p e n d s o n t w o f a c t o r s , t h e f i r s t i s t h e t y p e o f i n p u t s i g n a l b a l a n c e d o r
unbalanced, and the second the ground configuration of the sound source (floating or ground-
referenced). The next pictures show some of the different possibilities of connection, relying on the
type of input signal, balanced or unbalanced and according to the ground configuration of the
equipment (floating or ground-referenced).
In the next diagrams, we use the following symbols:
Sound source with mains cord without ground connection.
Sound source with mains cord with ground connection.
Sound source with the EARTH-LINK OFF.
Sound source with the EARTH LINK ON.
UNBALANCED INPUT:
Th i s t yp e o f c o n n e c t i o n w i l l b e u s e d w h e n t h e s o u n d s o u r c e d o e s n o t p r o vi d e b a l a n c e d
output. If it’s possible it is better using the connection type 1.
1) U s i n g t w i n - l e a d s h i e l d e d c a b l e :
Downloaded from www.Manualslib.com manuals search engine
9
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
2) Using single conductor shielded cable:
BALANCED INPUT:
PA OUTPUT CONNECTION
Th e PA o u t p u t s i g n a l i s c a r r i e d o u t t h r o u g h a X LR- 3 - 3 2 m a l e c o n n e c t o r . Th e o u t p u t i s
balanced, with a nominal impedance of 100 . The next list shows the input pins correspondence
as A.E.S recommends:
Downloaded from www.Manualslib.com manuals search engine
10
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
PA OUTPUT - XLR- 3- 32
PIN 1
0 V
PIN 2 HOT (+ )
PIN 3
COLD (- )
Th e o u t p u t c o n n e c t i o n d e p e n d s o n t w o f a c t o r s , t h e f i r s t i s t h e t y p e o f i n p u t s i g n a l b a l a n c e d o r
unbalanced, and the second the ground configuration of the sound destination unit (floating or
ground-referenced). The next pictures show some of the different possibilities of connection,
relying on the type of output signal, balanced or unbalanced and according to the equipments
ground configuration (floating or ground-referenced).
In the next diagrams, we use the following symbols:
Sound destination unit with mains cord without ground connection.
Sound destination unit with mains cord with ground connection.
Sound destination unit with the EARTH-LINK OFF.
Sound destination unit with the EARTH LINK ON.
UNBALANCED OUTPUT:
Th i s t yp e o f c o n n e c t i o n w i l l b e u s e d w h e n t h e s o u n d d e s t i n a t i o n u n i t d o e s n o t p r o v i d e a
balanced input. If its possible it is better using the connection type 1.
1) U s i n g t w i n - l e a d s h i e l d e d c a b l e :
Downloaded from www.Manualslib.com manuals search engine
11
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
2) Using single conductor shielded cable:
BALANCED INPUT:
PA OUTPUT RELAY CONNECTION
Th e P A o u t p u t r e l a y c o n n e c t i o n a l l o w s t o c a r r y o u t a c o n t r o l o n a n e x t e r n a l a p p l i c a t i o n e ve r y
time the PA output is activated (connection with unidirectional transmission systems - radio
stations. Lights turn on/ off, motors, etc.).
Th e m u l t i p u r p o s e r e l a y c o n n e c t i o n t a k e s p l a ce w i t h a JA C K ¼ c o n n e c t o r . Th e n e x t l i s t s h o w s
the multipurpose relay PIN correspondence with the JACK ¼":
Downloaded from www.Manualslib.com manuals search engine
12
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
RELAY JACK ¼
COM M ON TIP
NORMALLY CLOSE RING
NORMALLY OPEN SLEEVE
In the factory configuration, the PA output relay is activated with the PA output switch, but the
multipurpose relay can be configured to be activated upon activating the channel A and/or B
microphone or upon activating the remote mute buzzers signal. In order to obtain more
information, consult the special operation section.
NOTE: The NORMALLY CLOSE terminal is joined with the COMMON terminal when the PA output is
not activated, and the NORMALLY CLOSE is joined with the COMMON terminal when the PA output
is activated.
EX T ER N A L U N I TS C O N N EC T I O N
Th e e x t e r n a l u n i t s c o n n e c t i o n t o t h e m a s t e r s t a t i o n i s c a r r i e d
through twin-lead shielded cable and XLR-3-31/ XLR-3-32
connectors. Each master station channel provides two XLR-3-31
connectors and a XLR-3-32 connector wired internally in parallel
mode.
Th e n e x t l i s t s h o w s t h e s i g n a l d i s t r i b u t i o n i n t h e p i n X LR
connectors.
XLR-3-31/ XLR-3-32 INTERCOM LINE
PIN 1
GND
PIN 2 + VDC
PIN 3
SI GN A L
Certa in rul es ha ve to b e follow ed w hen insta lli ng th e ca b les o f a n i ntercom system . This is to
avoid ground loops and to minimize the power loss and the possible effect of electromagnetic
fields.
Do not connect the XLR pin 1 to the XLR metal housing or to metal wall boxes to avoid ground
loops. The ground loop could increases notably the system background noise.
Do not close the intercom line connection (avoid closed loops). Each intercom line leaves from
the master station towards the remote stations, but it does not return to the master station. If the
connection is closed, a ground loop with the increase from the system noise will take place.
Use high quality cables and minimize its longitude. The DC resistance of a low quality cable or
very long affects to the power consumption, the channels crosstalk and the system frequency
response.
Place the master station the closest possible to the maximum consumption zone; that is to say
to the zone in which more external units are placed.
Th e n e x t p i c t u r e s h o w s t h e h a b i t u a l c o n n e c t i o n o f a n i n t e r c o m s y s t e m f o r m e d b y f o u r
beltpacks units (two for each channel) and a master station EF-200. In the section APPLICATION
EX A M PL ES a r e s h o w n a n o t h e r t y p e o f c o n n e c t i o n s .
T
IP.
RI N G.
SLEEVE.
Downloaded from www.Manualslib.com manuals search engine
13
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
MULTICHANNEL SYSTEM CONNECTION (MASTER-SLAVE)
Th e M A STER- SLA V E c o n n e c t i o n o f m a s t e r s t a t i o n s a l l o w s t o c a r r y o u t
multichannel systems and use an only headphone for all the intercom lines.
Th e c o n n e c t i o n i s m a d e w i t h a n 8 p i n RJ4 5 c a b l e (o f w i d e u s e i n c o m p u t e r
networks) without inverting (extension). We will introduce in the central unit that
we want to configure as master the cable connector FCC-68 in the master station
connector marked as MASTER, and in the master station we want to configure as
slave the other cable end in the master station connector marked as SLAVE. If we want to configure
more slave units, we will use another 8 pin RJ45 cable and we will connect the cable connector
FC C- 6 8 i n t h e f i r s t s l a v e u n i t , a n d t h e o t h e r c a b l e e n d i n t h e c o n n e c t o r FCC - 6 8 m a r k e d a s SLA VE o f
the following slave unit, and so forth up to one maximum of 5 master stations, what would give us
a maximum of 10 intercom lines controlled by this system.
Th e o p e r a t i o n i n M A STER- SLA V E m o d e i s v e r y s i m p l e . Th a t w a y , w e w i l l l i s t e n a l l t h e i n t e r c o m
lines in the headset connected to the master station. The volume control of each main station
adjusts the headset level of its local intercom lines (MASTER 1,2- SLAVE Nº1 3,4- SLAVE Nº2 5,6-
SLA VE N º 3 7 , 8 - SLA VE N º 4 9 , 10 ) a n d t h e l o c a l l i s t e n b a l a n c e c o n t r o l b e t w e e n i n t e r c o m l i n e s t h e
channel mix controlled by the main station.
Th e m i c s e n d i n g t o t h e d i f f e r e n t i n t e r c o m l i n e s i s c a r r i e d o u t w i t h t h e m i c o n / o f f s w i t c h o f
each intercom line (each main station controls two intercom lines).
Th e c a l l s i g n a l t o e a c h i n t e r c o m l i n e i s c a r r i e d o u t w i t h o f t h e C A LL s w i t c h a s s o c i a t e , a s w e l l
as each received call is shown in their associate channel (the associated led starts blinking and if
the buzzer is activated, the unit emits an intermittent sound). The buzzer on/ off switch is controlled
by each main station, as well as the remote mutes of all mics and buzzers.
In multichannel operation, it is possible to enable/ disable the microphones of all the stations
(m a ster o r sl aves), a s th e rem o te m u te b uzzers fu ncti on of a ll the sta tions a nd ca r r y o ut a ca ll to a ll
the system intercom lines (in order to obtain more information consult the section BUZZER
ON/ OFF SWITCH).
Th e p r o g r a m i n p u t c o r r e s p o n d i n g t o t h e m a i n s t a t i o n c o n f i g u r e d a s M A STER w i l l w o r k a l o n e
(ea ch m a in sta ti o n ca n b e co nfig ured so tha t i n sl ave m od e the p r og r a m inp ut w o rks- in o rd er to
Downloaded from www.Manualslib.com manuals search engine
14
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
obtain more information consult the section SPECIAL OPERATIONS), but it can be sent to all the
intercom lines with the local program send to lines A/ B switches and program input level control.
Fi n a l l y , u p o n p r e s s i n g t h e s l a ve l i n k s w i t c h o f t h e s l a v e u n i t ( t h e s l a ve l i n k s w i t c h o f t h e m a s t e r
unit is disable), the slave unit channel A will be linked with the master unit channel A, so that the
units connected to the master unit channel A can communicate with the slave unit channel A and
vice versa, and the calls carried out in any channel A will arrive to all the units connected to both
channels A. This switch, together with the channel A and B link switch allows linking all the
multichannel system channels.
Downloaded from www.Manualslib.com manuals search engine
15
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
CONNECTION OF INTERCOM SYSTEM S WITH M ORE THAN 5 0 BELTPACKS
It is possible connect two master stations (EF-200) in installations where it is necessary work
with more than 50 beltpacks (EM-201), with their lines in parallel (A with A and/or B with B), always
having the caution of opening the terminal impedance (in order to obtain more information,
consult the special operation section), of the secondary master station lines that serves us simply
how power reinforcement. In this type of operations, the master station unit is connected at the
beginning of the intercom chain, and the secondary unit at the end of this line, in this way, we will
reinforce the beltpack units power placed to the other end of the primary master station unit.
5. OPERATION
Th e E- 2 0 0 s e r i e s i n t e r c o m s y s t e m a r e d e s i g n e d t o a l l o w m a x i m u m e a s y c o m m u n i c a t i o n
operations between the different control areas in music or theatre live performances, television,
cinema, conference halls, and whatever broad events where multiple and fast communications are
required, by means of its simultaneous listening-speaking operation system.
Th e EF- 2 0 0 s y s t e m m a s t e r s t a t i o n p r o v i d e s t w o i n d e p e n d e n t i n t e r c o m c h a n n e l s , a n d t h e
capacity to feed up to 50 beltpacks (EM-201). Each channel provides a CALL switch, a MIC on/ off
switch (TALK), a listen balance control allows to listen to the channels independently, or a mix
between the two channels.
Th e p r o g r a m i n p u t a l l o w s t o i n s e r t e x t e r n a l a u d i o s i g n a l s i n t h e i n t e r c o m s ys t e m . Th e e x t e r n a l
audio signals could be sent to each channel or to the headphones, independently.
Th e h e a d s e t m i c r o p h o n e s i g n a l i s a v a i l a b l e t o d r i ve P. A . s y s t e m s . Re l a y c o n t a c t s a r e p r o v i d e d
that follows the P.A. key action, helping the installer to automate multiple tasks as Tally, switching
speakers, cue lights, etc.
Sy s t e m Ex p a n d a b i l i t y p e r m i t s c r e a t i n g a m u l t i c h a n n e l ( 4 , 6 , o r m o r e c h a n n e l s ) i n t e r c o m Sy s t e m
by using more Master Stations in a daisy chain arrangement. This feature enables freedom in System
design and in-site future upgrades. Rental companies can benefit in lower component inventories.
Th e g l o b a l a l l m i c (M i c - K i l l ) a n d b u z z e r s ( Bu z z - Ki l l ) m u t e s y s t e m s i n b o t h c h a n n e l s , a l l o w t o
control the line noise, as well as the ambient noise.
Our new internal Battery op eration permits short- time communications in difficult situations ( =
no Power) of emergency..
HEADSET CONNECTION
A XLR-4 type connector (XLR-4-32) allows to connect a headset and a microphone to the
master station. The headset impedance must be 200 or higher (up to 2 K) a nd the m icro p ho n e
must be dynamic or electret type.
Th e m i c r o p h o n e p r e a m p l i f i e r g a i n c a n b e c o n f i g u r e d w i t h a n i n t e r n a l p r e s e t i n + 3 0 o r + 4 0
dB. (In the factory set-up the microphone preamplifier gain is adjusted to +40 dB)
Fo r t h e e l e c t r e t m i c r o p h o n e t y p e i t i s n e c e s s a r y t o e n a b l e t h e p h a n t o m p o w e r o f 9 VD C w i t h
an internal preset. In order to obtain more information, consult the special operation section.
Th e n e x t l i s t s h o w s t h e X LR p i n s c o r r e s p o n d e n c e :
HEADSET - XLR-4-32
PIN 1
0 V (MICROPHONE)
PIN 2
SI GN A L (M I CRO P H O N E)
PIN 3
0 V (HEADPHONES)
PIN 4
SI GN A L ( H EA D P H O N ES)
Downloaded from www.Manualslib.com manuals search engine
16
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
NOTE: Headphones can be with a double or single muff. In case of using a double muff
headphone, the two speakers should be wired in parallel mode.
HEADSET VOLUME CONTROL
Th e vo l u m e c o n t r o l a l l o w s a t t e n u a t i n g o r a m p l i f yi n g t h e s i g n a l s e n t t o t h e
headphones. This control adjusts the listen level to the headphones as you wish.
PA- M IC OUTPUT + RELAY CONTROL SWITCH
Th e PA - M I C s w i t c h a l l o w s t o e n a b l e t h e PA OU TPU T p l a c e d a t t h e r e a r p a n e l ,
which normally is disabled, and to carry out this way the microphone signal sending
picked up in the HEADSET to other audio systems, activating at the same time the
multipurpose relay (PA OUTPUT RELAY) placed at the rear panel (factory set-up).
In fact, we have explained the factory set- up in the previous paragraph. The PA OUTPUT can
be configured to always be enable, one can enable the PA OUTPUT and the multipurpose relay
activating the channel A and/or B microphone independently or activating the buzzer mute signal
(BUZZER REM OTE M UTES). When ever the PA OUTPUT a nd the m u l ti purp ose r el ay a re a cti va ted , the
PA- M IC sw i t ch a s so c i a t ed LED w i l l tu r n o n (i n th e ca se o f a c ti va t i n g t h e PA OUTPUT p e r m a n e n tl y,
the multipurpose relay won't be always activated, and the PA-MIC associated LED will turn off). In
order to obtain more information, consult the special operations section.
BUZ Z ER ON/ OFF SWITCH
Th i s s w i t c h e n a b l e s / d i s a b l e s t h e b u z z e r s o u n d w h e n t h e u n i t r e c e i v e s a c a l l .
When this sw itch is p ressed q uickly, a nd the b uzzer is ena b led , it w ill be d isa b led ,
and the LED indicator will turn off. On the other hand, if the buzzer was disabled, it
will be enabled and the LED indicator will lighten up.
Th e b u z z e r s o u n d i s d i f f e r e n t w h e n a c a l l f r o m t h e c h a n n e l A i s r e c e i ve d t h a t w h e n i s
received from the channel B, as well as when a simultaneous call from both channels takes place.
Th e b u z z e r a l s o s o u n d s w h e n a n y s w i t c h i s p r e s s e d , e m i t t i n g a s h o r t h o o t , w h o s e l e ve l i s
higher when it is enabled than when it is disabled.
Th e b u z z e r s o u n d l e ve l c a n b e c o n f i g u r e d w i t h a n i n t e r n a l j u m p e r ( i n t h e f a c t o r y s e t - u p t h e
buzzer sound level is configured high). In order to obtain more information, consult the special
operations section.
When the b uzzer sw itch is p ressed a nd hold s o n e second , the u nit enter s in g lob a l m od e
and the LED associated with the buzzer switch begins to blink.
When the u nit is in g lob a l m od e, it is p ossi b le to ca rr y out ca ll s from th e m a ster unit to a ll the
intercom channels (to all channels of the master unit and to all channels of the slave units), simply
pressing the CALL switch of any of the master unit channels.
Also in global mode, we can turn on/ off the microphones and the buzzer remote mute
signal (see the next paragraph for more information) of the master unit and all their associated
slave units. If the mic switch (TALK) of any of the intercom channels is pressed (when the system is
in global mode), and the microphone was disabled (the associated LED was turn off), all the
microphones of the master unit and all their associated slave units will be enabled. On the other
hand, if the microphone was enabled (the associated LED was turn on), all the microphones of the
master unit and all their associate slave units will be disabled.
Th e b u z z e r r e m o t e m u t e s i g n a l w o r k s i n a s i m i l a r w a y . I f t h e b u z z e r r e m o t e m u t e w a s
disabled, upon pressing the buzzer remote mute switch (when the system is in global mode), the
buzzer remote mute signal of the master station and all their associated slave units will be
enabled. On the other hand, if the buzzer remote mute signal was enabled, the buzzer remote
mute signal of the master station and all their associated slave units will be disabled.
Once the call sw itch, the microphone sw itch or the buzzer remote m ute sw itch w as pressed
Downloaded from www.Manualslib.com manuals search engine
17
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
the system will leave the global mode, stopping blinking the associated LED to the buzzer switch.
If we want to leave the global mode without carrying out any of the functions previously
mentioned, we simply will press quickly the BUZZER switch and the system will leave the global
mode, stopping blinking the associated LED to the buzzer switch.
REM O TE M U TE ALL M I CS AN D BU Z Z ER SW I TCH ES
Th e s e s w i t c h e s a l l o w t o d i s a b l e a l l t h e m i c r o p h o n e s ( A LL M I C S) a n d a l l t h e
buzzers (BUZZERS) of both channels of the intercom system (including all the
beltpacks, desk station units and master station units) except the one from the
master station from that these switched are activated.
Th e r e m o t e m u t e A LL M I C S s w i t c h c a r r i e s o u t t h e f u n c t i o n u p o n p r e s s i n g i t . Th i s
means that the units (beltpacks, desk stations units, etc.) connected to the system can turn on the
microphones again when its required. When this switch is pressed, its associated LED turns on
during a moment.
Th e B U Z Z ERS s w i t c h , o n t h e o t h e r h a n d , c a r r i e s o u t a n o n / o f f f u n c t i o n . If t h e r e m o t e m u t e
buzzers function was enabled, when the remote mute buzzers switch is pressed the remote mute
buzzers function is disabled and the associated LED becomes turned off (in this moment all the
external units could enable their local buzzers again); if, on the other hand, it was disabled, when
the remote mute buzzers switch is pressed the remote mute buzzers function is enabled and the
associated LED becomes turned on (at this moment the buzzers of all the external units will be
disabled and they can not be enabled again locally).
CALL SWITCH
Th e EF- 2 0 0 m a s t e r u n i t i s p r o vi d e d w i t h t w o c a l l s w i t c h e s , o n e p e r i n t e r c o m
channel. When one of these switches is pressed a call signal is sent to the
corresponding intercom channel. The call signal makes the LED associated with the
switch start blinking; if the buzzer is enabled (consult buzzer on/ off section for more
information) an intermittent sound takes place during three seconds (the LED blinking, as well as
the buzzer sound is different if the call takes place in the channel A or B), the same as in all the
units (beltpacks, desk stations, master stations, etc.), connected to the same intercom channel.
If the CALL switch is pressed continuously, the duration of the call signal will be higher (the
time that the switch is pressed, and approximately 3 seconds more).
If a call signal is generated in an external unit (beltpacks, desk stations, master stations, etc.),
the LED associated to the CALL switch of the channel in which the call signal is received, will start
blinking and if the buzzer is enabled (see buzzer on/ off section for more information) an
intermittent sound will take place during about three seconds.
MIC ON/OFF/PUSH TO TALK SWITCH
Th e EF- 2 0 0 m a s t e r u n i t i s p r o vi d e d w i t h t w o t a l k s w i t c h e s , o n e p e r i n t e r c o m c h a n n e l .
Th e TA LK s w i t c h a l l o w s t o e n a b l e / d i s a b l e t h e m i c r o p h o n e , s o t h a t w e a r e a b l e t o s p e a k
with other units connected to the same intercom channel. If the channel A micro-phone
isn’t activated (for example), and the channel B microphone is activated, we will speak with
the stations connected to the channel B, but the connected stations to the channel won’t hear us.
If the microphone is activated, its associated LED will light up, and on the other hand, if it is
disabled, its associated LED will turn off.
Th e TA LK s w i t c h e s h a v e t w o o p e r a t i o n m o d e s . W h e n t h i s s w i t c h i s p r e s s e d q u i c k l y , t h e
microphone changes its state; if it was enabled, being pressed it gets disabled and turns off the
associated LED, and if it was disabled, being pressed it gets enabled and turns on the associated
LED.
Downloaded from www.Manualslib.com manuals search engine
18
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
When the TALK sw itches are p ressed a nd h el d , the uni t w ill en ter i n th e sp ecia l fu n ctio n PUSH
TO TA LK ; t h i s m e a n s t h a t t h e m i c r o p h o n e w i l l b e e n a b l e d u n t i l t h e s w i t c h i s r e l e a s e d .
SIDETONE CONTROL
Th e s i d e t o n e c o n t r o l a d j u s t s t h e l e ve l o f yo u r o w n vo i c e a s y o u h e a r i t i n y o u r
headphones. It is designed to make approximately at the potentiometer halfway travelling
the maximum cancellation of your own voice (that is to say that you won't hear your voice
through the headphones), totally to the right or to the left giving the maximum level of voice,
passing through all the intermediates level positions.
Th e m a s t e r s t a t i o n u n i t h a s t w o s i d e t o n e c o n t r o l s , o n e f o r e a c h c h a n n e l . I t i s n e c e s s a r y t o
adjust each sidetone control independently, disabling a channel and adjusting the other and vice
versa.
LI N E A A N D B LI ST EN B A LAN C E C O N TRO L
Th e l i s t e n b a l a n c e c o n t r o l b e t w e e n l i n e s A a n d B a l l o w s t o a d j u s t t h e s i g n a l
mix of both channels that appears in the headset of the main station. Totally to the
left, the signal that appears in the headset is only the channel A signal, totally to the
right, the signal that appears in the headset is only the channel B signal, centered it
appears a mix between both channels and in intermediates positions, it adjusts the
level that we want to listen of each channel.
PROGRAM INPUT LEVEL CONTROL
Th e p r o g r a m i n p u t l e v e l c o n t r o l a d j u s t s t h e s i g n a l l e ve l s e n t t o t h e c h a n n e l s A a n d
B of the p rog ra m inp u t signa l (the sig na l introd u ced b y the p ro g ra m inp ut connecto r
XLR-3-31 placed at the rear panel). Next to the program input level control is marked the
position in which the gain is 0, that is to say the same signal as in the input. Totally to the
left the signal decreases in 10 dB and totally to the right the signal increases in 20 dB.
Keep in m ind that these gains are influenced by the position of the progra m input
MICRO/ LINE switch selector (placed at the rear panel), becouse if this switch is in mode micro, we
have 30 dB of additional gain.
PROGRAM SENDING TO LINES A/ B SWITCHES
Th e p r o g r a m s e n d i n g t o l i n e s A / B s w i t c h e s i n j e c t s t h e p r o g r a m s i g n a l i n t h e
corresponding channel (there is a switch for each channel) and all the units connected
to the corresponding channel will listen the program signal.
PROGRAM TO HEADPHONES CONTROL
Th e p r o g r a m t o h e a d p h o n e s c o n t r o l a l l o w s t o r e g u l a t e t h e p r o g r a m s i g n a l l e ve l t h a t
appears in the headsets connected to the master station unit EF-200, independently if the
program sending to lines A/ B switches is pressed or not. Keep in mind that if the program
input signal is sent to the lines, the signal sent directly to the headphones directly will be
added to the signal sending directly to the lines (attenuated by the sidetone control, previously
explained).
LI N ES A A N D B LI N K SW I T C H
Th e l i n e s A a n d B l i n k s w i t c h a l l o w s t o j o i n t h e t w o c h a n n e l s , s o t h a t t h e s a m e s i g n a l
appears in both channels. If the channels A and B are linked, the units connected to the
channel A can communicate with the one connected to the channel B and vice versa, and
the calls carried out in any channel will arrive to all the units connected to both channels.
Downloaded from www.Manualslib.com manuals search engine
19
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
SLAVE CHANNELS LINK SWITCH
Th i s s w i t c h i s o n l y e n a b l e d w h e n t h e u n i t i s c o n f i g u r e d i n s l a v e m o d e , i n m a s t e r m o d e
it is disabled. In a multichannel system, the slave channels link switch of the slave station
allows to join the master station unit channel A with the slave station unit channel A, this
way the same signal appears in both channels. If the channels are linked, the units connected to
the master station channel A can communicate with the connected to the slave station channel A,
and the calls carried out in any channel A (master or slave) will arrive to all the units connected to
both channels A.
Th i s s w i t c h , t o g e t h e r w i t h t h e l i n e s A a n d B l i n k s w i t c h a l l o w s t o j o i n a l l t h e c h a n n e l s o f a
multichannel system.
EM ERG EN C Y S W I T CH ( B A T T ER Y O PERA TI O N )
Th e e m e r g e n c y s w i t c h a l l o w s t h e b a t t e r y o p e r a t i o n o f t h e i n t e r c o m s ys t e m i n
mains power failures.
If a battery (6LR61 type - 9VDC, the use of alkaline batteries is recommended) is
installed in the battery holder placed at the rear panel (consult emergency battery
placement section for more information), and there is a cut in the mains power supply,
upon pressing this switch, the system will turn on for 10 minutes or until the mains power supply is
recovered (what happens before).
Th e a p p r o x i m a t e d u r a t i o n o f a n a l k a l i n e b a t t e r y, i n a s y s t e m w i t h a m a s t e r s t a t i o n u n i t a n d
four beltpacks, is an hour.
6. OPTIONS
In this section we will explain the different available options for the master station EF-200 unit.
PROGRAM INPUT TRANSFORM ER (IT- DA)
In order to improve the common mode rejection ratio and get a galvanic isolation with the
previous part of the audio system, an input transformer for the program input is available.
Th e p r o v i d e d t r a n s f o r m e r s f u l f i l t h e i s o l a t i o n r u l e o f 1. 5 k V .
PA OUTPUT TRANSFORM ER (OT- DA)
In order to get a galvanic isolation with the next part of the audio system, an output
transformer for the PA output is available.
Th e p r o v i d e d t r a n s f o r m e r s f u l f i l t h e i s o l a t i o n r u l e o f 2 k V .
SECURITY COVER (TP- 1)
In some installation, it may be necessary to tamper proof the front panel controls avoiding
unwanted or accidental manipulations. For this purpose, it is available as an option, a transparent
plastic security cover. The installation is very easy, only with two provided screws.
KEY LOCKED SECURITY COVER (TS- 1)
In some installations it is necessary to isolate the master station unit controls with more
security than with the plastic security cover. For this extra protection, it is available an all-metallic
and lockable security cover. This option cover fits into the four rack holes of the unit and includes
rear nut-bars allowing the installation as a stand-alone unit.
Th i s c o ve r p r e v e n t s a l s o f r o m u n a u t h o r i s e d e x t r a c t i o n w h e n t h e u n i t i s r a c k m o u n t e d .
Downloaded from www.Manualslib.com manuals search engine
20
E- 2 0 0 SER I ES I N T ERC O M SY ST EM EF- 2 0 0 D U A L C H A N N EL M A ST ER S TA T I ON
7. SPECIAL OPERATIONS
In order to set-up some of the master station possibilities, the unit must be opened removing
the eight screws of the unit top cover, and for the input and output transformers placement also the
eight screws of the unit bottom cover, to solder the transformers.
NOTE: This type of operations takes place with the unit is opened; the best thing should be to carry it
out by a qualified technician.
DANGER: Before opening the unit, disconnect it from the mains. It is important to indicate that
although the unit is switched off (with the power switch in 0 position), if it keeps being connected to
the mains there are different parts of the unit that are subjected to high voltage.
CAUTION: Protect the master station from the rain and moisture, mostly if it is open. If liquid is spilled
into the unit, disconnect it from the mains and consult a qualified service technician.
PROGRAM INPUT TRANSFORM ER (IT- DA)
In order to improve the input common mode rejection ratio and for a galvanic isolation with
the previous part of the audio system, an input transformer is available.
Th e p r o g r a m i n p u t h a s a n i n s e r t p o i n t f o r t h e i n p u t t r a n s f o r m e r (TR2 ) p l a c e d j u s t b e s i d e t h e
XLR-3-31 program input connector, in the rear right corner of the main PCB.
Befo r e p la cin g the tra nsfo r m er, you sh ould rem ove the tw o lin ks corresp on d in g to th e
program input transformer (LK3 and LK4).
In the following picture is shown the placement of the input transformer TR2. It is important to
keep in mind the placement of the input transformer pins to make it coincide with the main PCB
(fo ur b eh in d a nd th re e forw a rd ).
Remove the links corresponding to the program input
transformer (LK3 and LK4).
Place the input transformer, keeping in mind the position of their
pins (four behind and three forward), and solder it to the main PCB.
OUTPUT TRANSFORMER (OT- DA)
In order to make a galvanic isolation with the next part of the audio system, an output
transformer is available.
Th e PA o u t p u t h a s a n i n s e r t p o i n t f o r t h e o u t p u t t r a n s f o r m e r (TR1) p l a c e d j u s t b e s i d e t h e X LR-
3-32 pa output connector, in the rear right corner of the main PCB.
Th e f o l l o w i n g p i c t u r e i s s h o w i n g t h e p l a c e m e n t o f t h e o u t p u t t r a n s f o r m e r TR1. It i s i m p o r t a n t
to keep in mind the placement of the output transformer pins to make it coincide with the main
PCB (seven b e h in d a n d si x f o r w a r d ).
Befo r e p la cin g the tra nsfo r m er, you sh ould rem ove the tw o lin ks corresp on d in g to th e p a
output transformer (LK1 and LK2).
Downloaded from www.Manualslib.com manuals search engine
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Altair EF-200 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI