e-mail: info@moxa.com.tw www.moxa.com
2-8
Total Solution for Industrial Device Networking
Serial Device Server Solutions
e-mail: info@moxa.com.tw www.moxa.com
2-9
NPort 5410, 5430, 5430I
Features
World’s First LCM Display Serial Device Server
Easy-to-use LCM (Liquid Crystal Module) interface for setting
up IP address
Auto-detecting 10/100 Mbps Ethernet
4 ports with RS-232 or RS-422/485 interface
Surge protection for all serial signals (15 KV ESD)
Supports TCP Server, TCP Client, UDP, and Real COM Modes
Supports web, telnet, console
Supports SNMP MIB-II for network management
NPort 5430I has 2 KV isolation protection
The NPort 5400 series provides a convenient and transparent
way to connect serial devices to an Ethernet, with basic
conguration all that’s needed to network your existing
serial devices. Protect your current hardware investment,
but also ensure future network expandability. Moreover, the
NPort 5400 series can transparently transmit data bi-direc-
tionally between the serial and Ethernet interfaces. You can
simultaneously centralize your serial device management
and distribute management hosts over the network.
Make Up to 4 RS-232 or RS-422/485
Serial Devices Internet Ready
The built-in LCM human-machine interface displays all con-
guration parameters, and includes 4 buttons for inputting
data, or for selecting the operation mode, making it easy
to set up server parameters, including IP address, netmask,
and gateway address. Furthermore, you can also monitor
server status and data transmission, eliminating the need
to prepare additional PCs during installation.
Easy-to-use Serial Device Server
The NPort 5400 series works like an add-on multiport
serial board to the Windows host, but with one major
advantage—the TCP/IP network.
With NPorts Real COM/TTY drivers, the serial ports on NPort
5400 series products are recognized as Real COM ports by
the Windows operating system, or Real TTY ports by Linux
environments. Basic transmit/receive data functions are
provided, as well as RTS, CTS, DTR, DSR, and DCD (input)
control signals.
Real COM/TTY Port
Versatile operation is ensured since different modes can be
used for different serial ports. NPort 5400 Series products are
suitable for connnecting different devices for remote data
polling, event handling, or data multicasting via the TCP/IP
network. For example, you can congure NPort 5400’s port
1 for driver mode, port 2 for TCP server mode, and ports 3
and 4 for TCP client mode.
4 Independent Serial Ports Can be Congured
for Different Operation Modes
NPort 5410
NPort 5430
5410, 5430, 5430I
Serial Device Server Solutions
Serial Device Server Solutions
e-mail: info@moxa.com.tw www.moxa.com
2-8
Total Solution for Industrial Device Networking
Serial Device Server Solutions
e-mail: info@moxa.com.tw www.moxa.com
2-9
Window Host A Window Host B
Ethernet
NPort 5410
RS-232
RTU RTU RTURTU
Host As
COM3
Host As
COM4
Host B’s
COM3
Host B’s
COM4
NPort 5430I
Host A Host B
Ethernet
PLC
4-wire RS-422
Meter
2 or 4-wire RS-485 Multidrop
Typical Applications
4-Port RS-232 and RS-422/485 Serial Device Servers
Use only one IP address to control multiple serial
devices over the Internet
To establish automatic or remote data acquisition, NPort
5400 series products can connect up to 4 serial devices
with only one IP address.
By specing the IP address and the TCP port number, a
host computer can access different serial devices over the
Internet. For example, connect to 192.168.10.2:4001 to
access data from NPort 5410’s rst serial port.
Server sharing extends exibility by allowing serial
device management from a centralized connection
Different host computers can share the same NPort
5400 series to control different devices. For example,
NPort 5410’s ports 1 and 2 can be congured to Host As
COM3 and COM4, and NPort 5410’s ports 3 and 4 can be
congured for Host B’s COM3 and COM4.
Centralize RS-422/485 serial device control
Up to 31 RS-485 (2-wire or 4-wire) devices or up to 9 RS-
422 (4-wire) devices can be connected via Ethernet with
NPort 5430I’s serial port. Use the Web console or NPort
5000 series Windows utility to congure each serial port
for either RS-422 or RS-485.
Remote host
Local host
Internet
NPort 5410
192.168.10.2
RS-232
4004
4003
4002
TCP Port
4001
PLC Fire Alarm
Control
Temprature
Control
Entrance
Control
Ethernet
5410, 5430, 5430I
Serial Device Server Solutions
Serial Device Server Solutions
e-mail: info@moxa.com.tw www.moxa.com
2-10
Total Solution for Industrial Device Networking
Serial Device Server Solutions
e-mail: info@moxa.com.tw www.moxa.com
2-11
Specications
An Amazingly Simple and Exquisite Device Server
LAN
Ethernet: 10/100 Mbps, RJ45
Protection: Built-in 1.5 KV magnetic
isolation
Serial
Interface:
NPort 5410:
RS-232, DB9 Male
RS-232: TxD, RxD, RTS, CTS,
DTR, DSR, GND
NPort 5430, NPort 5430I:
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485 (4-wire): Tx+, Tx-, Rx+, Rx-, GND
RS-485 (2-wire): Data+, Data-, GND
Serial line protection:
15 KV ESD for all signals
2 KV Isolation for NPort 5430I
Power Line protection:
4 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5
RS-485 data direction: Patented
Automatic Data Direction Control
(ADDC
TM
)
Built-in HMI
LCM display with four push buttons
Built-in Buzzer
Built-in Real Time Clock
Built-in Watch Dog Timer
Serial Communication Parameters
Parity: None, Even, Odd, Space, Mark
Data bits: 5, 6, 7, 8
Stop bit: 1, 1.5, 2
Flow control: RTS/CTS, XON/XOFF
Speed: 50 bps to 230.4 Kbps
Software Features
Protocols: ICMP, IP, TCP, UDP, DHCP,
BootP, Telnet, DNS, SNMP, HTTP, SMTP,
SNTP
Utilities: NPort Administrator for
Windows 95/98/ME/NT/2000/XP
Real COM/TTY Drivers: Windows 95/
98/ME/NT/2000/XP Real COM drivers,
Linux real tty driver
Conguration: Web browser, telnet
console, or Windows utility
Power Requirments
Power Input: 12 to 48 VDC
Power Consumption:
5410: 385 mA (at 12V max.)
5430: 380 mA (at 12V max.)
5430I: 600 mA (at 12V max.)
Mechanical Specications
Material: SECC sheet metal (0.8 mm)
Gross Weight:
5410: 0.5 kg (1.10 lb)
5430: 0.5 kg (1.10 lb)
5430I: 0.5 kg (1.10 lb)
Environmental
Operating Temperature:
0 to 55˚C (32 to 131˚F), 5 to 95% RH
Storage Temperature:
-20 to 85˚C (-4 to 185˚F), 5 to 95% RH
Agency Approvals
EMC: FCC Class A, CE Class A
Safety: UL, CUL, TÜV
LCM Display Panel
DB9 Male connector
RS-232 with 15 KV ESD protection
DIN-Rail or Panel mounting
Optional DIN-Rail (35 mm) Mounting Kit
Power input
Terminal block 12-48 VDC
Ethernet
RJ45 10/100 Mbps
Reset Button
Push Button
LEDs
LAN and Serial status
5410, 5430, 5430I
Serial Device Server Solutions
Serial Device Server Solutions
e-mail: info@moxa.com.tw www.moxa.com
2-10
Total Solution for Industrial Device Networking
Serial Device Server Solutions
e-mail: info@moxa.com.tw www.moxa.com
2-11
Ease Your Installation with the User
Friendly LCM Display Panel
Ordering Information
Dimensions
4-Port RS-232 or RS-422/485 Serial Device Server
NPort 5400 series products have 4 push buttons for inputting data and
for selecting the operation mode. The LCM display panel rst shows the
“Server Name,” “Serial Number,” and “IP Address.” Use the LCM display
panel and push buttons to congure the IP address, netmask, gateway,
as well as all other parameters quickly and easily.
NPort 5410’s Pin Assignment
NPort 5410: 4-Port RS-232 Serial
Device Server
NPort 5430: 4-Port RS-422/485 Serial
Device Server
NPort 5430I: NPort 5430 with 2 KV
isolation
All Items include:
• 4-port serial device server
• Quick Installation Guide
• NPort Document and Software
CD-ROM
Optional Accessory
DK-35A: DIN-Rail Mounting Kit
(35 mm)
1 2 3 4 5
6 7 8 9
Pin RS-232
1 DCD (in)
2 RxD (in)
3 TxD (out)
4 DTR (out)
5 GND
6 DSR (in)
7 RTS (out)
8 CTS (in)
9 ---
Unit: mm (inch)
5410, 5430, 5430I
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Moxa Technologies 5430I User manual

Category
Servers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI