Eneo EDC-IPC-1 Mounting instructions

Category
Security cameras
Type
Mounting instructions

This manual is also suitable for

1
Montageanleitung
Gehäuse EDC-IPS-1, EDC-IPC-1, EDC-OPS-1, EDC-OPC-1
für Wand- und Deckenmontage und EDC-IDF für Deckeneinbau,
für Fastrax Dome-Videokamera-Serie
Mounting Instructions
Housing EDC-IPS-1, EDC-IPC-1, EDC-OPS-1, EDC-OPC-1
for wall and ceiling mounting, and EDC-IDF for in-ceiling installation
for the Fastrax Dome video camera series
Mode d’installation
Boîtiers EDC-IPS-1, EDC-IPC-1, EDC-OPS-1, EDC-OPC-1
pour xation murale et plafond et boîtiers EDC-IDF à encastrer dans le plafond
pour caméra dôme vidéo Fastrax
2
3
Inhalt
1. Sicherheitshinweise............................................................................3
2. Allgemeine Beschreibung....................................................................3
3. Montage des Wand- und Deckenabhängegehäuses ............................4
4. Montage des Deckeneinbaugehäuses .................................................6
5. Technische Daten ...............................................................................7
6. Maßzeichnungen ..............................................................................18
Contents
1. Safety instructions ..............................................................................8
2. General description.............................................................................8
3. Assembling the wall mounted and ceiling suspended housing ............9
4. Assembling the in-ceiling housing.....................................................11
5. Technical specications ....................................................................12
6. Dimensional drawings.......................................................................18
Sommaire
1. Consignes de sécurité.......................................................................13
2. Description générale.........................................................................13
3. Installation du boîtier pour xation murale et au plafond ...................14
4. Installation du boîtier à encastrer dans le plafond..............................16
5. Caractéristiques techniques..............................................................17
6. Croquis.............................................................................................18
Betriebsanleitung
Installation and Operating Instructions
Mode d’emploi
www.eneo-security.com/manuals
8
9
1. Safety instructions
Read these safety instructions and the operation manual rst before you install and commission the camera.
Keep the manual in a safe place for later reference.
Protect your camera from contamination with water and humidity to prevent it from permanent damage. Never switch the camera on when it gets wet.
Have it checked at an authorized service center in this case.
Do not operate the cameras beyond their specied temperature, humidity or power ratings.
Operate the camera only at a temperature range of -10°C to +50°C and at a humidity of max. 90%.
To disconnect the power cord of the unit, pull it out by the plug. Never pull the cord itself.
Pay attention when laying the connection cable and observe that the cable is not subject to heavy loads, kinks, or damage and no moisture can get in.
Do not attempt to disassemble the camera board from the dome.
The warranty becomes void if repairs are undertaken by unauthorized persons.
Use a dry cloth to clean the dome surface. In case the dirt is hard to remove, use a mild detergent and wipe gently.
Note: This is a class A digital device. This digital device can cause harmful interference in a residential area; in this case the user may be required
to take appropriate corrective action at his/her own expense.
2. General description
Indoor housing for Fastrax Series wall and ceiling mounted cameras
Standard version with fan
Housing with tinted bubble: 6.8" (172mm), EDP No. 74075
Housing with clear bubble: 6.8" (172mm), EDP No. 74077
Protection class: IP65
Accessories pack: 3x dowel
3x screws with O-type sealing rings
1x Allen key 2mm for grub screw
3x screws M4x8
3x screws, tapping 4mm with O-type sealing ring
1x headless screw M4x4 for securing the housing to the pipe
1x Teon tape
Outdoor housing for cameras of the Fastrax series for wall and ceiling mounting
Standard version with heater, fan and sunshield
Housing with tinted bubble: 6.8” (172mm), EDP No. 74078
Housing with clear bubble: 6.8” (172mm), EDP No. 74076
Protection class: IP65
Accessories pack: 3x dowel
3x screws with O-type sealing rings
1x Allen key 5mm for sun shield
1x Allen key 2mm for grub screw
3x screws M4x8
3x screws, self tapping 4mm with O-type sealing ring
1x grub screw M4x4 for securing the housing to the tube
1x Teon tape
1x silicone (for sealing between mounting surface and mounting plate on the housing)
Dome housing for mounting of dome cameras in suspended ceilings, EDP No. 74057
For in-ceiling installation of dome cameras of the Fastrax series
Tinted bubble: 4.9” (125mm)
Accessories pack: 1x safety ring string (wire)
5x screws, self-tapping (M4, 12mm long)
1x screw, self-tapping (M4, 12mm long)
8
9
3. Mounting the wall mounted and ceiling suspended housing
A B
push
push
Remove window
Bubble
Srew
Fan & heater board
Loosen 3 screws
Dome base
Dome base board
Dome connector
Dome camera
Housing ring
1. Use the enclosed screws (M6) with O-type sealing rings and dowels to secure the enclosed mounting plate to the wall or ceiling.
2. Type EDC-OPS/C: If the housing is mounted in the outdoor area or in an area with intense insolation, the sunshield
112
(metal bubble) is placed
over the indoor housing
102
. The hexagon spacer bolts with internal screw thread
106
are pre-assembled on the internal housing.
Type: EDC-IPS/C: The system does not contain a sunshield
112
(metal bubble); no hexagon head screws are assembled on the indoor housing.
3. Wrap the enclosed Teon tape
520
around the screw thread of the pipe (respectively approx. 20 wraps).
4. Push all required cables through assembly plate
101
and tube.
5. Screw the tube wrapped in Teon tape into the enclosed assembly plate until rmly in place. If the length of the tube exceeds 1m, a metal socket
must be screwed in-between. Every extension must have a PT1 1/4"-screw thread.
6. Camera bracket
200
is pre-assembled in the indoor housing
102
and must be unscrewed. Insert the drop shaped indoor housing
102
into the
tube and twist until rmly in place.
7. Connect 24VAC-cable for heater and fan (outdoor housing only) to the connector board
400
; lay onward from the connector board to the dome
camera (cables are not enclosed).
8. Rescrew camera bracket
200
to the indoor housing. Connect the external video cable (with BNC-connector) to the video cable of the dome
connector plate.
9. Screw dome connector plate of the camera housing into the spacer bolts with internal screw thread of the camera bracket
200
by means of the
3 enclosed screws. Connect power supply and data cable to the contact strip with the plug of the camera.
Note: When connecting several cameras, the second 24VAC-connector can be used as an output.
10. Install dome-ID (identication) (refer to operating instructions of the dome camera)
11. It is recommended, not to assembly the dome enclosed with the camera and to remove the window in front of the lens (refer to g. A and B).
12. Insert the dome camera into the dome connector plate. The indicator „lock open“ must thereby snap into place in the nib of the connector plate.
Twist the dome camera to the right until a clear click can be heard. Check whether the camera is securely in place.
13. Remove safety strip from the dome camera.
14. Insert bubble
105
with housing ring
104
incl. sealing ring
103
(the components
105
,
104
and
103
are provided pre-assembled as 1 component)
into the indoor housing
102
(M4-screws
107
are enclosed). For easier insertion or removal, the sealing ring should previously be treated with
talcum or the like. The 3 nibs in the ring serve as a guide on insertion into the internal housing.
Seal using silicone rub-
ber around the circle
24VAC
OUT
24VAC
IN
10
11
112
111
113
101
106
109
102
201
301
108
105
103
107
104
110
204
108
201
207
202
206
205
203
208
Parts list, No. refer to exploded diagram
No. Part Description Quant.
301 assembly plate for fan and heater aluminium 1
302 fan 40x40x10 DC 24V 2
303 heater 50W AC 24V 1
304 machine screws M3x5 6
305 machine screws M3x10 8
400 connector board f. fan and heater 1
No. Part Description Quant.
101 assembly plate aluminium 1
102 indoor housing aluminium 1
103 sealing ring silicone 1
104 housing ring ABS 1
105 bubble acrylic 1
106 spacer bolt for sunshield 3
107 screws M4x25 3
108 machine screws M4x8 ZN 6
109 O-ring 12cm 1
110 O-ring AN-158 3
111 O-ring 5mm 6
112 sunshield aluminium 1
113 Allen screws M6x16 3
200 camera bracket metal
201 base plate metal 1
202 guide rails metal 3
203 assembly ring metal 1
204 spacer bolt M6x48 3
205 machine screws M6x16 3
206 spacer bolt M4x15 3
207 machine screws M4x12 6
208 machine screws M4x12 3
No. Part Description Quant.
501 plastic connector 4
502 tapping screws M6x30 4
503 adjusting screw M4x4 2
504 machine screws M4x25 3
505 machine screws M4x8 3
506 O-ring 4mm 3
507 O-ring 5mm 3
508 Allen key 5mm 1
509 Allen key 2mm 1
510 tube of silicone 1
520 Teon tape 1
Accessories kit
400
304 305 301
302
304
303
10
11
Illustrations Note: The ceiling plate must be no thicker than 2.4cm.
1 Mark and cut out a section with 184 in the ceiling plate by means of a stencil (packaging box).
2 Screw dome connector plate to the ceiling bracket 2 + 3 (screw No. 6).
Pull power supply cable, video cable and data cable through the gap in the dome connector plate.
3 Insert bracket into the ceiling gap and secure.
4 In order to secure the bracket, this may be attached to the ceiling by means of the arrester cable 10 .
Connect the external video cable (with BNC-socket) to the video cable of the dome connector plate. Connect power supply and data cable
to the contact strip.
Note: When connecting several cameras, the second 24VAC-connector can be used as an output.
Install dome-ID (identication).
Pull off safety strip.
5 Insert the camera into the ceiling connector plate. The indicator „lock open” must thereby snap into the nib of the connector plate.
Twist the dome camera to the right until a clear click can be heard. Check whether the camera is rmly in place.
6 Place trim ring 1 on the ceiling bracket and insert into the track.
7 Ready assembled dome camera with bubble.
Note: The clear bubble is included in delivery of the camera. By request, this may be exchanged against the tinted bubble (included in
delivery of the housing for ceiling installation). To assemble the dome, unscrew the grub screw on the housing ring (black) of the camera
and remove the ring. Place clear or tinted bubble onto the camera and secure to the camera by means of the grub screw.
4. Assembling the in-Ceiling Housing
1
2
4
3
7
6
5
12
10
11
12
13
without camera bubble with camera bubble
are supplied pre-assembled)
5. Technical specications
No. Quant. Component Description
1 1 trim ring plastic
2 1 plate for ceiling bracket aluminium (No. 2, 3 and 5
3 3 braces for ceiling bracket
4 3 retaining clip aluminium
5 1 ring for ceiling bracket aluminium
6 6 screws tapping M4x12mm
7 3 screws M4x55mm
8 1 screw M4x6mm
9 3 E-rings 4mm
Accessories kit
1 1 arrester cable
2 5 tapping screws M4x12mm
3 1 tapping screw M4x12mm
Type EDP-IPC-1 EDC-IPS-1 EDC-OPC-1 EDC-OPS-1 EDC-IDF
Indoor housing for wall/ceiling mounting Outdoor housing for wall/ceiling mounting Housing for in-ceiling mounting
EDP No.
74077 74075 74076 74078 74057
Connection
1 1/4” tube thread
Installation
In suspended ceiling (ceiling plate
up to max. 2.4cm in thickness)
Colour
Light grey polyester powder coating Black cover
Housing
Aluminium, pipes: steel, dome holder: plastic Base frame: steel, cover: alumini-
um, bubble: tinted plexiglass
Bubble
Clear Tinted (loss of light:
0.5 aperture stops)
Clear Tinted (loss of light:
0.5 aperture stops)
Tinted
Housing ring
with bubble
ABS ring
Power consumption Approx. 76W (for heating 50W, fan 6W and camera 20W)
Switching point of
the heating themostat
+5°C (± 5K) On
+15°C (± 5K) Off
Weight
Approx. 3.5kg Approx. 4.3kg Approx. 300g
Protection rating
IP 65 IP 65
Power supply
24VAC, 50/60Hz
Accessories
EDP No.
Description
70449
Power supply unit NE-122, 230V/24VAC-4A, IP66
74054, EDC-CMA2
Corner mount adapter for EDC-IPS/C or OPS/C-housing
74055, EDC-PM7
Pole mount adapter for EDC-IPS/C or OPS/C-housing
74074, EDC-RTB
Amounting rack (pillar) for EDC-IPS/C or OPS/C-housing
74090, EDC-PRMB
Parapet and roof mount bracket
Accessories of
EDP No.
Description
74049
1/4” colour high-speed dome camera, 18x zoom lens
74050
1/6” colour high-speed dome camera, 25x zoom lens
74081
1/4” colour high-speed dome camera, 18x zoom lens
74086
1/4” colour high-speed dome camera, 18x zoom lens
6. Dimensional Drawings
See page 18
18
19
6. Maßzeichnungen/Dimensional drawings/
Croquis
Maße / Dimensions / Croquis: mm
EDV-Nr./EDP No./Code inf. 74057
mit montierter Kamera / with mounted camera / avec caméra
170
145
1 1/4”
600
6
200
160
200
160
8.5
20
ohne Kamerakuppel /
without camera bubble /
sans coupole
mit Kamerakuppel /
with camea bubble /
avec coupole
Ständer für die Dome-Kamera /
Support for dome camera /
Support pour la caméra dôme
EDV-Nr./EDP No./Code inf. 74074
Deckenplatte /
Ceiling plate /
Plaque de plafond
4x 10
P.C, D. 130.0
90.0
3
8.5
50
48.7
160
PT 1 1/4"
P.C, D. 107.0
3x 6.5
680 max.
235
680 max.
280
370
370
173
100
~270
420
100
~270
420
173
Außengehäuse /
Outdoor housing /
Boîtier extérieur
Innengehäuse /
Indoor housing /
Boîtier interne
Deckenplatte /
Ceiling plate /
Plaque de plafond
18
19
WEEE (Waste Electrical & Electronic Equipment)
Korrekte Entsorgung dieses Produkts
(Anzuwenden in den Ländern der Europäischen Union und anderen europäischen Ländern mit einem separaten
Sammelsystem)
Die Kennzeichnung auf dem Produkt bzw. auf der dazugehörigen Literatur gibt an, dass es nach seiner Lebensdauer nicht
zusammen mit dem normalen Haushaltsmüll entsorgt werden darf. Entsorgen Sie dieses Gerät bitte getrennt von anderen
Abfällen, um der Umwelt bzw. der menschlichen Gesundheit nicht durch unkontrollierte Müllbeseitigung zu schaden.
Recyceln Sie das Gerät, um die nachhaltige Wiederverwertung von stofichen Ressourcen zu fördern.
Private Nutzer sollten den Händler, bei dem das Produkt gekauft wurde, oder die zuständigen Behörden kontaktieren,
um in Erfahrung zu bringen, wie sie das Gerät auf umweltfreundliche Weise recyceln können.
Gewerbliche Nutzer sollten sich an Ihren Lieferanten wenden und die Bedingungen des Verkaufsvertrags konsultieren.
Dieses Produkt darf nicht zusammen mit anderem Gewerbemüll entsorgt werden.
Correct Disposal of This Product
(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the
end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government ofce, for
details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product should not be mixed with other commercial wastes for disposal.
Élimination conforme du présent produit
(Applicable dans l’Union européenne et dans d’autres pays européens disposant de systèmes de collecte distincts)
Le marquage indiqué sur le produit ou dans le mode d’emploi indique qu’il ne devrait pas être éliminé avec d’autres déchets
ménagers à la n de sa vie de service.
Pour éviter tout effet néfaste sur l’environnement ou sur la santé humaine résultant de l’élimination non contrôlée de déchets,
séparez ce produit des autres types de déchets et recyclez-le de manière responsable an de promouvoir l’utilisation durable
des ressources matérielles.
Les utilisateurs ménagers doivent contacter soit le revendeur où ils ont acheté ce produit, soit leur organisme gouvernemental
local pour obtenir plus d’informations sur le recyclage correct de cet article an de protéger l’environnement.
Les utilisateurs commerciaux doivent contacter leur fournisseur et vérier les modalités du contrat de vente.
Ce produit ne doit pas être mélangé à d’autres déchets commerciaux lors de leur élimination.
20
eneo
®
ist eine eingetragene Marke der Videor Technical E. Hartig GmbH
Vertrieb ausschließlich über den Fachhandel.
eneo
®
is a registered trademark of Videor Technical E. Hartig GmbH
Exclusive distribution through specialised trade channels only.
eneo
®
est une marque propriété de Videor Technical E. Hartig GmbH
Distribution et vente à travers les distributeurs spécialisés.
VIDEOR TECHNICAL E. Hartig GmbH
Carl-Zeiss-Straße 8 · 63322 Rödermark/Germany
Tel. +49 (0) 60 74 / 888-0 · Fax +49 (0) 60 74 / 888-100
www.videortechnical.com
Änderungen vorbehalten.
Technical changes reserved.
Nous nous réservons toutes modications techniques.
© Copyright by VIDEOR TECHNICAL 01/06
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Eneo EDC-IPC-1 Mounting instructions

Category
Security cameras
Type
Mounting instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages