Using the Flomatic Valve with Gauges 5029717 1/11
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
6. Remove the valve from unit by pulling the valve away from dispenser. (Figure 5)
7. Install the Flomatic Valve with Gauges on dispenser by lining the valve stems
up with back block and pushing into place. (Figure 6)
8. Push the latch pin down to secure valve into place. (Figure 7)
9. Turn both back block shutoff valves to the on position. (Figure 8)
10. Plug the 24v low voltage connector into the solenoid of the Flomatic Valve with
Gauges. (Figure 9)
11. Now the gauges on the valve should be reading the Static pressure on the
valve. (Figure 10) Note: The gauge on the left side of the valve is reading water
pressure, and the gauge on the right side of the valve is reading syrup
pressure.
12. Next read the Dynamic Pressure by monitoring the gauges while activating the
valve. The pressure each gauge reads when dispensing a beverage is the
Dynamic Pressure of the fluid being applied to the valve. Dynamic pressure
tells you how much pressure you have to a valve under a specific load. See the
chart below for minimum and maximum dynamic pressures for Flomatic
valves.
13. When finished using Flomatic valve with gauges for testing water and syrup
pressures, replace the original beverage valve by following steps 1-10 in
reverse order.
MINIMUM DYNAMIC PRESSURES
FOR FLOMATIC VALVES
Flomatic Valve Type Minimum Pressure
424 20 psi
464 20 psi
FIGURE 5
FIGURE 6
FIGURE 7
FIGURE 8
FIGURE 9
FIGURE 10
WATER
PRESSURE
GAUGE
SYRUP
PRESSURE
GAUGE