MULTIPLEX Flomatic Valve Installation guide

Type
Installation guide
Instructions
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
Subject: Using the Flomatic Valve with Gauges
The Flomatic Valve with Gauges is designed to provide a trouble-shooting device to
determine whether or not you have adequate water and syrup pressures entering a
beverage dispensing valve. Please follow the steps below for installing, and using
the Flomatic Valve with Gauges. If you have any questions about the functionality of
the valve, or how to install the valve please contact the Service Department at
Manitowoc Beverage Systems, 1-800-367-4233.
Steps for using the Flomatic Valve with Gauges:
1. Remove the cover from the valve at location where incoming water & syrup
pressures need to be tested. (Figure 1)
2. Turn both shutoffs on valve back block to the off position. (Figure 2)
3. Press dispense switch on valve to release pressure in valve and to assure both
water and syrup are shut off at back block.
4. Disconnect the 24v low voltage connector from the valve solenoid. (Figure 3)
5. Pull latch pin up to release valve from back block. (Figure 4)
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
5029717
1/11
Using the Flomatic Valve with Gauges 5029717 1/11
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
6. Remove the valve from unit by pulling the valve away from dispenser. (Figure 5)
7. Install the Flomatic Valve with Gauges on dispenser by lining the valve stems
up with back block and pushing into place. (Figure 6)
8. Push the latch pin down to secure valve into place. (Figure 7)
9. Turn both back block shutoff valves to the on position. (Figure 8)
10. Plug the 24v low voltage connector into the solenoid of the Flomatic Valve with
Gauges. (Figure 9)
11. Now the gauges on the valve should be reading the Static pressure on the
valve. (Figure 10) Note: The gauge on the left side of the valve is reading water
pressure, and the gauge on the right side of the valve is reading syrup
pressure.
12. Next read the Dynamic Pressure by monitoring the gauges while activating the
valve. The pressure each gauge reads when dispensing a beverage is the
Dynamic Pressure of the fluid being applied to the valve. Dynamic pressure
tells you how much pressure you have to a valve under a specific load. See the
chart below for minimum and maximum dynamic pressures for Flomatic
valves.
13. When finished using Flomatic valve with gauges for testing water and syrup
pressures, replace the original beverage valve by following steps 1-10 in
reverse order.
MINIMUM DYNAMIC PRESSURES
FOR FLOMATIC VALVES
Flomatic Valve Type Minimum Pressure
424 20 psi
464 20 psi
FIGURE 5
FIGURE 6
FIGURE 7
FIGURE 8
FIGURE 9
FIGURE 10
WATER
PRESSURE
GAUGE
SYRUP
PRESSURE
GAUGE
  • Page 1 1
  • Page 2 2

MULTIPLEX Flomatic Valve Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI