Brake Connection Diagram
Brake Assembly
1
2
L2
A
L1
T1 T2 T3
Circuit Breakers
or
Fused Inputs
Motor
Fuse
Stop Start
M
Surge Suppressor
M
OL
OLOLOL
MMM
Control Board
T1
T2
T3
J5
Existing
Site Wiring
CPT
460V
230V
208V
L2
L1
F1
F2
TB1
Notes:
TB1 pins 1 and 4 must be jumpered
together.
TB1 pins 2, 3, 5 and 6 are not used.
Add surge suppressor if not
included in contactor coil.
115VAC for the Start / Stop control
circuit may be obtained from 1. the
secondary of the line transformer. or
2. Control circuit TB1 pins 9 and 10
(115VAC) may optionally be used.
Schematic applies to Brake in Basic
Mode only.
BC
6543
Input Line
Phase
BC
87 109
F3
LB0085A00
1–17 seconds brake time
Zero speed sensing active
Brake is operational
Off/On
Basic operating mode
7/00