LSI 3ware SAS 9750-8i User guide

Category
RAID controllers
Type
User guide

This manual is also suitable for

3war
SATA+SAS
Controller Card
Software User Guide
Supports the 9750-4I and 9750-8I Models
PN: 45414-00, Rev. A
November 2009
User Guide
Document Description
Document 45414-00, Rev. A. November 2009.
This document will remain the official reference source for all revisions and
releases of this product until rescinded by an update.
Disclaimer
It is the policy of LSI Corporation to improve products as new technology,
components, software, and firmware become available. LSI reserves the right
to make changes to any products herein at any time without notice. All
features, functions, and operations described herein may not be marketed by
LSI in all parts of the world. In some instances, photographs and figures are of
equipment prototypes. Therefore, before using this document, consult your
LSI representative for information that is applicable and current. LSI DOES
NOT ASSUME ANY RESPONSIBILITY OR LIABILITY FOR THE USE
OF ANY PRODUCTS DESCRIBED HEREIN EXCEPT AS EXPRESSLY
AGREED TO IN WRITING BY LSI.
LSI products are not intended for use in life-support appliances, devices, or
systems. Use of any LSI product in such applications without written consent
of the appropriate LSI officer is prohibited.
License Restriction
The purchase or use of an LSI Corporation product does not convey a license
under any patent, copyright, trademark, or other intellectual property right of
LSI or third parties.
Copyright Notice
© 2009 LSI Corporation. All rights reserved.
Trademark Acknowledgments
LSI, the LSI logo design, 3ware
®
, 3DM
®
, StorSwitch
®
, and TwinStor
®
are all
registered trademarks of LSI Corporation. StorSave, and StreamFusion are
trademarks of LSI. Linux
®
is a registered trademark of Linus Torvalds in the
United States, other countries, or both. SUSE
®
is a registered trademark of
Novell, Inc. Windows
®
is a registered trademark of Microsoft Corporation in
the United States and other countries. Firefox
®
is a registered trademark of
the Mozilla Foundation. Safari
®
is a registered trademark of Apple Inc.,
registered in the U.S. and other countries. PCI Express
®
is a registered
trademark of PCI-SIG
®
. All other brand and product names may be
trademarks of their respective companies.
www.lsi.com/channel/products iii
Table of Contents
About this User Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
How this User Guide is Organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Screenshots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Using the 3ware HTML Bookshelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Chapter 1. Introducing the LSI 3ware SATA+SAS RAID Controller Card. . . . . . . . . .1
Highlights of the 10.0 Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Understanding RAID Concepts and Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
RAID Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Available RAID Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Determining What RAID Level to Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Using Drive Capacity Efficiently . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Support for Over 2 Terabytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3ware Tools for Configuration and Management . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Monitoring, Maintenance, and Troubleshooting Features . . . . . . . . . . . . . . . . . . . . . 15
Chapter 2. First-Time RAID Configuration Using 3BM. . . . . . . . . . . . . . . . . . . . . . . .18
Basic Steps for Creating a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Specifying a Hot Spare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Making Drives Visible to the Operating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Checking the Motherboard Boot Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
What Next? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Chapter 3. Getting Started with Your 3ware RAID Controller . . . . . . . . . . . . . . . . . .28
Chapter 4. Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Driver Installation Under Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Materials Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Creating a 3ware Driver Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Installing the 3ware Driver and Windows on a New RAID Unit . . . . . . . . . . . . . 34
Installing the 3ware Driver on a Windows System that Boots
from a Different Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Making Units Managed by a 3ware Controller Available to Windows . . . . . . . . 38
Driver Installation Under Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Obtaining 3ware Linux Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Driver Installation Under Red Hat or Fedora Core Linux . . . . . . . . . . . . . . . . . . 41
Driver Installation Under SUSE Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Compiling a 3ware Driver for Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Chapter 5. 3ware BIOS Manager (3BM) Introduction . . . . . . . . . . . . . . . . . . . . . . . . .51
Starting 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Exiting the 3BM Configuration Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Working in the 3BM Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Adjusting BIOS Option Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Displaying Information About the Controller and Related Devices . . . . . . . . . . . . . . 59
Getting Help While Using 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Chapter 6. 3DM 2 (3ware Disk Manager) Introduction . . . . . . . . . . . . . . . . . . . . . . . .61
iv 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Browser Requirements for 3DM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Installing 3DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Starting 3DM 2 and Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Logging In to the 3DM 2 Web Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Managing the 3DM 2 Daemon under Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Starting the 3DM 2 Process under Microsoft Windows . . . . . . . . . . . . . . . . . . . 65
Viewing 3DM 2 Remotely Using a Web Browser . . . . . . . . . . . . . . . . . . . . . . . . 65
Working with the 3DM 2 Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
3DM 2 Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Viewing Information About Different Controllers . . . . . . . . . . . . . . . . . . . . . . . . 68
Refreshing the Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
3DM 2 Screens and What They're Used For . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Setting Up 3DM 2 Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Setting and Changing 3DM 2 Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Managing E-mail Event Notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Enabling and Disabling Remote Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Setting the Listening Port # . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Setting the Frequency of Page Refreshes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Controlling Command Logging in 3DM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Chapter 7. Configuring Your Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Viewing Information About a Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
About Controller Policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Viewing Controller Policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Setting the Auto Rebuild Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Using Auto-Carving for Multi LUN Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Setting the Size of Volumes Created with Auto-Carving . . . . . . . . . . . . . . . . . . . . . . 86
Enabling and Setting Up Staggered Spin-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Viewing Information About a Phy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Changing the Phy Link Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Chapter 8. Configuring Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
Configuring a New Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Configuration Options When Creating a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Creating a Unit through 3DM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Creating a Unit through 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Ordering Units in 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Partitioning, Formatting, and Mounting Units . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Creating a Hot Spare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Specifying a Hot Spare through 3DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Specifying a Hot Spare through 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Naming a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Setting Unit Policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Enabling and Disabling the Unit Write Cache . . . . . . . . . . . . . . . . . . . . . . . . . 109
Working with Read Cache Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Enabling or Disabling Auto Verify for a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Setting Overwrite ECC (Continue on Source Error When Rebuilding) . . . . . . 116
Enabling and Disabling Queuing for a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Setting the StorSave Profile for a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Rapid RAID Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Changing An Existing Configuration by Migrating . . . . . . . . . . . . . . . . . . . . . . . . . 123
RAID Level Migration (RLM) Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Changing RAID Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Expanding Unit Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Informing the Operating System of Changed Configuration . . . . . . . . . . . . . . 127
Deleting a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
www.lsi.com/channel/products v
Deleting a Unit through 3DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Deleting a Unit through 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Removing a Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Removing a Unit Through 3DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Removing a Unit Through 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Moving a Unit from One Controller to Another . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Moving Units from an Earlier 9000 Series to a 9750 Controller . . . . . . . . . . . . 134
Adding a Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Removing a Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Rescanning the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Chapter 9. Maintaining Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Checking Unit and Drive Status through 3DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Viewing a List of Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Enclosure Drive LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Unit Statuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Drive Statuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
About Degraded Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
About Inoperable Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Locating a Drive by Blinking Its LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Alarms, Errors, and Other Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Viewing Alarms, Errors, and Other Events . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Using the Alert Utility Under Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Downloading an Error Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Viewing SMART Data About a Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Background Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
About Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
About Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Using Auto Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Starting a Verify Manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Rebuilding Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Cancelling a Rebuild and Restarting It with a Different Drive . . . . . . . . . . . . . 165
Working with the Background Task Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Setting the Background Task Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Setting Background Task Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Background Task Prioritization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Scheduling Background Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Viewing Current Task Schedules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Turning On or Off Use of a Rebuild/Migrate Task Schedule . . . . . . . . . . . . . . 171
Selecting Advanced or Basic Verify Schedules . . . . . . . . . . . . . . . . . . . . . . . . 172
Removing a Task Slot from a Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Adding a New Task Schedule Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Selecting Self-tests to be Performed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Chapter 10. Maintaining Your Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Determining the Current Version of Your 3ware Driver . . . . . . . . . . . . . . . . . . . . . . 176
Updating the Firmware and Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Downloading the Driver and Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Updating the Firmware Through 3DM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
Updating the Firmware Through DOS Using the 3ware Bootable CD . . . . . . . 180
Updating the 3ware Driver Under Windows . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Updating the 3ware Driver Under Red Hat or Fedora Core . . . . . . . . . . . . . . 183
Updating the 3ware Driver Under SUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
Viewing Battery Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Testing Battery Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
vi 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Chapter 11. Enclosure Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
Viewing a List of Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Checking Enclosure Component Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Fan Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Temp Sensor Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Power Supply Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Slot Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Locating a Specific Enclosure Component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Working with Enclosure Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Controlling an Enclosure Alarm In 3DM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Turning Off an Enclosure Alarm in 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Downloading an Enclosure Diagnostic Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Chapter 12. 3DM 2 Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
Controller Summary page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Controller Details page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Unit Information page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Unit Details page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Drive Information page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Drive Details window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Controller Phy Summary page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Controller Settings page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Scheduling page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Maintenance page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Alarms page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Battery Backup page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Enclosure Summary page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Enclosure Details page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
3DM 2 Settings page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Chapter 13. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238
Web Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Before Contacting Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Basic Troubleshooting: Check This First . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Command Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Drive Performance Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Types of DPM Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Available DPM Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Problems and Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Enclosure-Related Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Hardware Installation Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Software Installation Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Problems in 3DM and 3BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Error and Notification Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
Error and Notification Message Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .302
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
Installing Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
Installing Software from a Graphical User Interface (GUI) . . . . . . . . . . . . . . . 310
Installing Software on Linux from the Command Line . . . . . . . . . . . . . . . . . . . 314
Uninstalling 3ware Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
Uninstalling 3ware Software under Microsoft Windows . . . . . . . . . . . . . . . . . . 316
Uninstalling 3ware Software under Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
www.lsi.com/channel/products vii
Compliance and Conformity Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317
FCC Radio Frequency Interference Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
Canadian Compliance Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
European Community Conformity Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Warranty, Technical Support, and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Warranty Service and RMA Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
LSI Technical Support and Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Sales and ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Feedback on this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
viii 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
About this User Guide
This document, 3ware SATA+SAS RAID Controller Card Software User
Guide, Version 10.0, provides instructions for configuring and maintaining
RAID units on LSI
®
3ware
®
9750 series RAID controllers, using software
and firmware version 10.0.
This guide assumes that you have already installed your 3ware RAID
controller and drives in your system and any enclosures, if you have them. If
you have not yet done so, see the installation guide that came with your
controller. If you do not have the printed copy, a PDF of the installation guide
is available on your 3ware CD, or you can download it from:
http://www.lsi.com/channel/ChannelDownloads.
There are often multiple ways to accomplish the same configuration and
maintenance tasks for your 3ware RAID controller. This manual includes
instructions for performing tasks using two tools:
3ware BIOS Manager (3BM), which runs at the BIOS level
3ware Disk Manager 2 (3DM
®
2), which runs in a browser
You can also perform many tasks at the command line, using 3ware’s
Command Line Interface (CLI). The CLI is described in a separate manual:
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.0.
Information from both this Users Guide and the CLI Guide are also available
in the 3ware HTML Bookshelf, available in the 3ware Documentation folder
and on your 3ware CD. (For more information, see “Using the 3ware HTML
Bookshelf” on page xi.)
How this User Guide is Organized
www.lsi.com/channel/products ix
How this User Guide is Organized
Table 1: Chapters and Appendices in this Guide
Chapter/Appendix Description
1. Introduction Provides an overview of product features for the
3ware 9750 controller models. Includes system
requirements and an introduction to RAID concepts
and levels.
2. Getting Started Provides a summary of the process you should follow
to get started using your 3ware RAID controller.
3. First-Time RAID
Configuration Using
3BM
Provides step-by-step instructions for configuring
RAID units in the BIOS (3BM) if you have just installed
the controller.
4. Driver Installation Describes how to install drivers for the 3ware
controller if you have just installed and configured it.
Includes information for Windows
®
, and Linux
®
.
5. 3ware BIOS Manager
(3BM)
Describes the basics of using 3BM.
6. 3ware Disk Manager 2
(3DM 2)
Describes the basics of using 3DM. Also includes
information about installing and uninstalling 3DM, and
how to start the 3DM process manually, if required.
7. Configuring Your
Controller
Describes how to view details about the controller,
check its status, and change configuration settings
that affect the controller and all associated drives.
8. Configuring Units Describes how to configure new units and hot spares,
change existing configurations, move units from one
controller to another, and set unit policies.
9. Maintaining Units Describes how to check unit and drive status, review
alarms and errors, schedule background maintenance
tasks, and manually start them, when necessary or
desirable. Includes explanations of initialization,
verify, rebuild, and self-tests.
10. Maintaining Your
Controller
Describes how to update the driver and firmware.
Also includes information about checking battery
status on a BBU (Battery Backup Unit).
11. Enclosure
Management
Describes how to view details about an enclosure,
check the status of enclosure components, and locate
specific enclosure components by blinking an
associated LED.
12. 3DM 2 Reference Describes the features and functions on each of the
pages in 3DM.
13. Troubleshooting Provides common problems and solutions, and
explains error messages.
x 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Conventions
The following conventions are used throughout this guide:
3BM refers to the 3ware BIOS Manager.
3DM and 3DM 2 both refer to the 3ware Disk Manager, version 2.
In the sections that describe using 3DM 2, current controller is used to
refer to the controller which is currently selected in the drop-down list.
Unit refers to one or more disks configured through 3ware to be treated by
the operating system as a single drive. Also known as an array. Array and
unit are used interchangeably throughout this manual.
Boldface is used for buttons, fields, and settings that appear on the screen.
Monospace font is used for code and to indicate things you type.
Screenshots
The screenshots in this documentation are examples only, and may not exactly
reflect the operating system and browser you are using. 3ware software works
on a number of different operating systems, including Mac OS X, Microsoft
Windows
®
, FreeBSD
®
, and Linux
®
, and runs in a number of different
browsers. In addition, the version numbers shown in screenshots for drivers,
firmware, and software may not match your version. For the current released
and tested version number, see the latest release notes.
In addition, the fields and columns in 3DM 2 vary for different models of
3ware RAID controllers. If you have multiple controllers of different models,
you may notice some differences when switching between them in 3DM. For
example, when displaying information about the 9750 or 9690SA controllers,
3DM displays “VPorts” (for virtual port) on some screens while for earlier
controllers the label is “port.”
A. Glossary Includes definitions for terms used throughout this
guide.
B. Software Installation Provides instructions for installing software
management tools (3DM 2 and CLI) and
documentation.
C. Compliance and
Conformity Statements
Provides compliance and conformity statement.
D. Warranty, Technical
Support, and Service
Provides warranty information and tells you how to
contact technical support.
Table 1: Chapters and Appendices in this Guide (Continued)
Chapter/Appendix Description
Using the 3ware HTML Bookshelf
www.lsi.com/channel/products xi
Using the 3ware HTML Bookshelf
The 3ware HTML Bookshelf is an HTML version of this user guide and the
CLI Guide, combined as one resource. It is available on your 3ware CD, in the
/doc/3wareHTMLBookshelf folder.
To make use of the 3ware HTML Bookshelf
To launch the bookshelf at the opening page:
Navigate to the folder
/doc/3wareHTMLBookshelf on the 3ware
CD and double-click the file
index.html.
When you use either of these methods, a navigation panel at the left
automatically opens. It includes a Table of Contents, Index, and Search.
You can also open the bookshelf by double-clicking any other html file in
the 3wareHTMLBookshelf folder. When you open an individual file, the
navigation pane does not automatically open. In this case, you can display
the navigation pane by clicking the
Show Navigation button at the left.
Figure 1. Navigation Button in the 3ware HTML Bookshelf Window
Click the Show
Navigation button to
display the Table of
Contents
xii 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Note: The 3ware HTML Bookshelf is created as a set of HTML documents
that are often displayed from a website. When installed on your personal
computer, some browsers flag them as “active content,” and require your
approval before displaying the content.
If you see messages similar to the following, you must confirm the display of
active content in order to see the pages.
www.lsi.com/channel/products 1
1
Introducing the LSI 3ware
SATA+SAS RAID Controller
Card
LSI 3ware RAID controllers deliver full-featured, true hardware RAID to
servers and workstations. 3ware RAID controllers offer Serial Attached SCSI
(SAS) and Serial ATA (SATA) interfaces. Combined with an advanced RAID
management feature-set that includes web-based, command-based, and API
(application programming interface) software components, LSI RAID
controllers provide compelling RAID solutions.
This section introduces the features and concepts of 3ware RAID controllers.
It is organized into the following topics:
Highlights of the 10.0 Release
System Requirements
Understanding RAID Concepts and Levels
3ware Tools for Configuration and Management
Monitoring, Maintenance, and Troubleshooting Features
Highlights of the 10.0 Release
Version 10.0 of the 3ware RAID Software and Firmware provides the
following features and benefits to the 3ware 9750 model RAID controllers.
Support for 6 Gbps SATA+SAS RAID On-a-Chip devices available on
the 3ware 9750 RAID controllers, with continued support for the 3ware
RAID software feature-set.
Read cache settings let you enable either Basic Read Caching or
Intelligent Read Caching to improve performance.
Background task mode provides low latency settings to improve
performance in video and audio applications.
Enclosure alarm support allows you to turn off or mute audible alarms in
supported enclosures that provide alarms.
Introducing the LSI 3ware SATA+SAS RAID Controller Card
2 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Advanced Content Streaming, a performance feature, provides increased
speeds for streamed data, such as video playback and editing, through
improved algorithms.
Rapid RAID Recovery increases the speed with which a degraded unit
can be rebuilt. It can also increase the speed of verification or
initialization that may occur in the event of an unclean shutdown.
Improved and simplified auto-verification and scheduling to help insure
your RAID units are verified on a regular basis.
Drive performance monitoring provides statistics to help trouble-shoot
performance issues.
Simultaneous RAID 6 parity generation to maximize RAID 6
performance
StreamFusion™ optimizes RAID 5 and RAID 6 disk accesses to
maximize application performance under heavy loads
StorSave™ BBU with write journaling optimizes data protection and
performance
RAID levels 0, 1, 5, 6, 10, 50, and Single Disk
With the 9750 models:
PCI Express
®
x8 Gen 2.0
Ability to have SAS and/or SATA drives on the same controller (see
“Drive Requirements” on page 3)
Connectivity with up to 96 single-ported drives or 48 dual-ported
drives
Up to 32 drives in a unit
Up to 32 active units
System Requirements
3ware 9750 model RAID controllers have the following requirements:
Motherboard and Slot Requirements
A workstation-class or server-class motherboard, with an available PCI
Express x8 or x16 slot that complies with PCIe Gen 2.0 (recommended for
best performance) or PCIe 1.1.
A list of motherboards that have been tested is available at
http://www.lsi.com/channel/support/marketing_resources, through the Data &
Interoperability tab.
System Requirements
www.lsi.com/channel/products 3
Drive Requirements
The 3ware 9750 RAID controller may be connected to up to 48 SAS and/or
SATA dual-ported drives, or 96 SAS and/or SATA single-ported drives, when
using one or more enclosures. A maximum of 32 drives are allowed per RAID
unit and up to 32 active RAID units per controller.
You cannot mix SAS and SATA drives in the same unit.
Drives and drive enclosures must meet SAS (3.0 Gbps and 6.0 Gbps) and
SATA (3.0 Gbps) standards.
A list of drives that have been tested is available at
http://www.lsi.com/channel/support/marketing_resources, through the Data &
Interoperability tab.
Drives may be of any capacity or physical form factor.
The length of internal unshielded interface cables may not exceed 1 meter (39
inches).
Enclosure Management Requirements
For 9750 controllers and release 10.0, enclosure management features in
3ware software are available for supported chassis that provide SCSI
Enclosure Services 2 (SES-2) through an internal sideband connection, or via
an expander.
When chassis enclosures are cascaded, expanders of the same type are
recommended. A limit of 4 cascaded expanders is supported.
A list of supported enclosures is available at
http://www.lsi.com/channel/support/marketing_resources, through the Data &
Interoperability tab.
Operating System
3ware 9750 RAID controllers may be used with the following operating
systems for Intel and AMD 32-bit and 64-bit x86 based motherboards:
Microsoft Windows Server 2003 and 2008
Microsoft Windows Vista and Windows 7
Red Hat Enterprise Linux
®
openSUSE Linux
SUSE
®
Linux Enterprise Server
Fedora Core Linux
Other Linux distributions based on open source Linux 2.6 kernel
Introducing the LSI 3ware SATA+SAS RAID Controller Card
4 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
For the latest supported operating systems, see the current Release Notes at
http://www.lsi.com/channel/ChannelDownloads or the file versions.txt,
available on the 3ware CD.
Other Requirements
Adequate air flow and cooling
Adequate power supply for drives
3DM 2 (3ware Disk Manager) displays information in a browser. It
requires one of the following browsers:
Internet Explorer 5.5 and later
Mozilla Firefox
®
1.2 and later
Safari
®
In addition:
JavaScript must be enabled
Cookies must be enabled
For best viewing, screen resolution should be 1024 x 768 or greater,
with 16-bit color or greater.
For a complete listing of features and system requirements, refer to the 3ware
SATA+SAS RAID Controller datasheets, available from the website at
http://www.lsi.com/channel/products/megaraid/sassata/index.html.
Understanding RAID Concepts and Levels
www.lsi.com/channel/products 5
Understanding RAID Concepts and Levels
3ware RAID controllers use RAID (Redundant Array of Independent Disks)
to increase your storage system’s performance and provide fault tolerance
(protection against data loss).
This section organizes information about RAID concepts and configuration
levels into the following topics:
“RAID Concepts” on page 5
“Available RAID Configurations” on page 6
“Determining What RAID Level to Use” on page 11
RAID Concepts
The following concepts are important to understand when working with a
RAID controller:
Arrays and Units. In the storage industry, the term “array” is used to
describe two or more disk drives that appear to the operating system as a
single unit. When working with a 3ware RAID controller, “unit” is the
term used to refer to an array of disks that is configured and managed
through the 3ware software. Single-disk units can also be configured in
the 3ware software.
Mirroring. Mirrored arrays (RAID 1) write data to paired drives
simultaneously. If one drive fails, the data is preserved on the paired
drive. Mirroring provides data protection through redundancy. In
addition, mirroring using a 3ware RAID controller provides improved
performance because 3ware’s TwinStor® technology reads from both
drives simultaneously.
Striping. Striping across disks allows data to be written and accessed on
more than one drive, at the same time. Striping combines each drive’s
capacity into one large volume. Striped disk arrays (RAID 0) achieve
highest transfer rates and performance at the expense of fault tolerance.
Distributed Parity. Parity works in combination with striping on RAID 5,
RAID 6, and RAID 50. Parity information is written to each of the striped
drives, in rotation. Should a failure occur, the data on the failed drive can
be reconstructed from the data on the other drives.
Hot Swap. The process of exchanging a drive without having to shut
down the system. This is useful when you need to exchange a defective
drive in a redundant unit.
Array Roaming. The process of removing a unit from a controller and
putting it back later, either on the same controller, or a different one, and
having it recognized as a unit. The disks may be attached to different ports
than they were originally attached to, without harm to the data.
Introducing the LSI 3ware SATA+SAS RAID Controller Card
6 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Available RAID Configurations
RAID is a method of combining several hard drives into one unit. It can offer
fault tolerance and higher throughput levels than a single hard drive or group
of independent hard drives. LSI's 3ware controllers support RAID 0, 1, 5, 6,
10, 50, and Single Disk. The information below provides a more in-depth
explanation of the different RAID levels.
RAID 0
RAID 0 provides improved performance, but no fault tolerance. Since the
data is striped across more than one disk, RAID 0 disk arrays achieve high
transfer rates because they can read and write data on more than one drive
simultaneously. The stripe size is configurable during unit creation. RAID 0
requires a minimum of two drives.
When drives are configured in a striped disk array (see Figure 2), large files
are distributed across the multiple disks using RAID 0 techniques.
Striped disk arrays give exceptional performance, particularly for data
intensive applications such as video editing, computer-aided design and
geographical information systems.
RAID 0 arrays are not fault tolerant. The loss of any drive results in the loss of
all the data in that array, and can even cause a system hang, depending on
your operating system. RAID 0 arrays are not recommended for high
availability systems unless additional precautions are taken to prevent system
hangs and data loss.
Figure 2. RAID 0 Configuration Example
RAID 1
RAID 1 provides fault tolerance and a speed advantage over non-RAID disks.
RAID 1 is also known as a mirrored array. Mirroring is done on pairs of
drives. Mirrored disk arrays write the same data to two different drives using
RAID 1 algorithms (see Figure 3). This gives your system fault tolerance by
preserving the data on one drive if the other drive fails. Fault tolerance is a
basic requirement for critical systems like web and database servers.
3ware uses a patented technology, TwinStor
®
, on RAID 1 arrays for improved
performance during sequential read operations. With TwinStor technology,
Understanding RAID Concepts and Levels
www.lsi.com/channel/products 7
read performance is twice the speed of a single drive during sequential read
operation.
The adaptive algorithms in TwinStor technology boost performance by
distinguishing between random and sequential read requests. For the
sequential requests generated when accessing large files, both drives are used,
with the heads simultaneously reading alternating sections of the file. For the
smaller random transactions, the data is read from a single optimal drive head.
Figure 3. RAID 1 Configuration Example
RAID 5
RAID 5 provides performance, fault tolerance, high capacity, and storage
efficiency. It requires a minimum of three drives and combines striping data
with parity (exclusive OR) to restore data in case of a drive failure.
Performance and efficiency increase as the number of drives in a unit
increases.
Parity information is distributed across all of the drives in a unit rather than
being concentrated on a single disk (see Figure 4). This avoids throughput
loss due to contention for the parity drive.
RAID 5 is able to tolerate 1 drive failure in the unit.
Figure 4. RAID 5 Configuration Example
Introducing the LSI 3ware SATA+SAS RAID Controller Card
8 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
RAID 6
RAID 6 provides greater redundancy and fault tolerance than RAID 5. It is
similar to RAID 5, but has two blocks of parity information (P+Q) distributed
across all the drives of a unit, instead of the single block of RAID 5.
Due to the two parities, a RAID 6 unit can tolerate two hard drives failing
simultaneously. This also means that a RAID 6 unit may be in two different
states at the same time. For example, one sub-unit can be degraded, while
another may be rebuilding, or one sub-unit may be initializing, while another
is verifying.
The 3ware implementation of RAID 6 requires a minimum of five drives.
Performance and storage efficiency also increase as the number of drives
increase.
Figure 5. RAID 6 Configuration Example
RAID 10
RAID 10 is a combination of striped and mirrored arrays for fault tolerance
and high performance.
When drives are configured as a striped mirrored array, the disks are
configured using both RAID 0 and RAID 1 techniques, thus the name RAID
10 (see Figure 6). A minimum of four drives are required to use this
technique. The first two drives are mirrored as a fault tolerant array using
RAID 1. The third and fourth drives are mirrored as a second fault tolerant
array using RAID 1. The two mirrored arrays are then grouped as a striped
RAID 0 array using a two tier structure. Higher data transfer rates are
achieved by leveraging TwinStor and striping the arrays.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342

LSI 3ware SAS 9750-8i User guide

Category
RAID controllers
Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI