Remote Sensors
The SST-W100 supports connecting up to two remote temperature sensors (SST-TEMP1 and/or SST-OTEMP1). These sensors are wired to the SST-W100
using #24 AWG cable. The table below displays the configurations supported through software. Refer to the SST-W100 Wireless Thermostat
Deployment Guide (009-0802-xx) when connecting each of the sensors.
Sensor Descriptions
Internal Sensor - The thermostat has an internal temperature sensor mounted on the PCB circuit board.
RS1 (Remote Sensor 1) - RS1 is hardwired to the terminal block on back panel and is typically mounted in a location away from the thermostat. The
RS1 connection is for internal/indoor (SST-TEMP1) use only and when attached, this disables the internal sensor. RS1 cannot be configured for
outdoor use.
RS2 (Remote Sensor 2) - This sensor is hardwired to the terminal block on back panel of the SST-W100 and can be used as either an internal/indoor
(SST-TEMP1) or external/outdoor (SST-OTEMP1) sensor.
Connect to a Local Wireless Network
The SST-W100 integrates into the Savant Control system through the local wireless network. The SST-W100 can connect to a wireless network using a
few different methods. The information below describes how to join a wireless network using the SSID of the network. The remaining methods are
described in the SST-W100 Wireless Thermostat Deployment Guide (009-0802-xx). Click the link in Additional Information section below.
1. Press any button on front panel of the SST-W100 to light up LCD for viewing.
2. Press the MENU button from the lower left side of the display.
3. From the Menu Selection screen, scroll to the Wi-Fi Setup selection using the arrow buttons.
4. Press Select to open the Wi-Fi Setup menu.
5. Scroll to the SSID selection and press Select. A Wi-Fi Networks menu appears.
6. Scroll to the local Wi-Fi network where the SST-W100 will be connected. Press the Join button to join this network.
7. If this network is secured, enter the passphrase for the network.
•
The up/down buttons scroll through the upper and lowercase letters, numbers, and special characters.
•
The < > arrows on the LCD display move to the next character in the passphrase.
Refer to the table of supported SSID Guidelines section below.
8. Select Done once the passphrase has been entered. The SST-W100 will connect to the Wi-Fi network. A Wi-Fi Network Status screen will open
displaying the connection information.
9. The SST-W100 is now connected to the local wireless network. Select Done to exit the Wi-Fi Network Status screen.
10. Select Done to exit the Menu Selection screen.
SSID Guidelines
Savant Wi-Fi products can connect to Wi-Fi networks that meet the following SSID guidelines:
32 characters - Firmware 2.13.00 or later
16 characters - Firmware prior to 2.13.00
Maximum Passphrase Length:
WPA/WPA2: 8-63 characters
WEP: 10-26 characters
For a list of supported characters, refer to remote sensor section of the SST-W100 Wireless Thermostat Deployment Guide (009-0802-xx).
Additional Information
For additional information on how to program the SST-W100, refer to the following documents which can be found on the Savant Customer
Community.
Savant Store > Climate > Thermostats
•
SST-W100 Wireless Thermostat Deployment Guide (009-0802-xx)
•
Savant Wireless Thermostat User Guide (009-0957-xx)
Regulatory
The following statements are applicable to the SST-W100:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications of this product, not approved
by manufacturer will void the user’s authority to operate the equipment.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
SST-W100 | 009-1309-01 | 160229
SST-W100 | 009-1309-01 | 160229
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2016 Savant Systems, LLC
Savant.com | 508.683.2500