Fujitsu T5220 User manual

  • Hello! I am an AI chatbot trained to assist you with the Fujitsu T5220 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SPARC
®
Enterprise
T5120 and T5220 Servers
Installation Guide
Manual Code : C120-E462-01EN
Part No. 875-4191-10
August 2007, Revision A
Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.
FUJITSU LIMITED provided technical input and review on portions of this material.
Sun Microsystems, Inc. and Fujitsu Limited each own or control intellectual property rights relating to products and technology described in
this document, and such products, technology and this document are protected by copyright laws, patents and other intellectual property laws
and international treaties. The intellectual property rights of Sun Microsystems, Inc. and Fujitsu Limited in such products, technology and this
document include, without limitation, one or more of the United States patents listed at http://www.sun.com/patents and one or more
additional patents or patent applications in the United States or other countries.
This document and the product and technology to which it pertains are distributed under licenses restricting their use, copying, distribution,
and decompilation. No part of such product or technology, or of this document, may be reproduced in any form by any means without prior
written authorization of Fujitsu Limited and Sun Microsystems, Inc., and their applicable licensors, if any. The furnishing of this document to
you does not give you any rights or licenses, express or implied, with respect to the product or technology to which it pertains, and this
document does not contain or represent any commitment of any kind on the part of Fujitsu Limited or Sun Microsystems, Inc., or any affiliate of
either of them.
This document and the product and technology described in this document may incorporate third-party intellectual property copyrighted by
and/or licensed from suppliers to Fujitsu Limited and/or Sun Microsystems, Inc., including software and font technology.
Per the terms of the GPL or LGPL, a copy of the source code governed by the GPL or LGPL, as applicable, is available upon request by the End
User. Please contact Fujitsu Limited or Sun Microsystems, Inc.
This distribution may include materials developed by third parties.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark
in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd.
Sun, Sun Microsystems, the Sun logo, Java, Netra, Solaris, Sun StorEdge, docs.sun.com, OpenBoot, SunVTS, Sun Fire, SunSolve, CoolThreads,
J2EE, and Sun are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries.
Fujitsu and the Fujitsu logo are registered trademarks of Fujitsu Limited.
All SPARC trademarks are used under license and are registered trademarks of SPARC International, Inc. in the U.S. and other countries.
Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems, Inc.
SPARC64 is a trademark of SPARC International, Inc., used under license by Fujitsu Microelectronics, Inc. and Fujitsu Limited
.
The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN
LOOK GUIs and otherwise comply with Sun’s written license agreements.
United States Government Rights - Commercial use. U.S. Government users are subject to the standard government user license agreements of
Sun Microsystems, Inc. and Fujitsu Limited and the applicable provisions of the FAR and its supplements.
Disclaimer: The only warranties granted by Fujitsu Limited, Sun Microsystems, Inc. or any affiliate of either of them in connection with this
document or any product or technology described herein are those expressly set forth in the license agreement pursuant to which the product
or technology is provided. EXCEPT AS EXPRESSLY SET FORTH IN SUCH AGREEMENT, FUJITSU LIMITED, SUN MICROSYSTEMS, INC.
AND THEIR AFFILIATES MAKE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND (EXPRESS OR IMPLIED) REGARDING SUCH
PRODUCT OR TECHNOLOGY OR THIS DOCUMENT, WHICH ARE ALL PROVIDED AS IS, AND ALL EXPRESS OR IMPLIED
CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE
EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Unless otherwise expressly set forth in such agreement, to the
extent allowed by applicable law, in no event shall Fujitsu Limited, Sun Microsystems, Inc. or any of their affiliates have any liability to any
third party under any legal theory for any loss of revenues or profits, loss of use or data, or business interruptions, or for any indirect, special,
incidental or consequential damages, even if advised of the possibility of such damages.
DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
v
Contents
Preface xiii
1. Preparing for Installation 1
Tools and Equipment Needed 3
Optional Component Installation 3
ESD Precautions 4
Installation Overview 4
Cabling Notes for Both Servers 6
Port Locations for Both Servers 7
Slide Rail Assembly Notes for Both Servers 10
Cable Management Notes for Both Servers 13
Safety Precautions 14
2. Installing the SPARC Enterprise T5120 and T5220 Servers 15
Installing the Servers in a Rack 16
To Install the Slide Rail Assemblies 16
To Insert and Lock the Server in the Rack 23
Installing the Cable Management Arm for Both Servers 25
To Install the Cable Management Arm 25
To Verify the Operation of the Slide Rails and the CMA 30
vi SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
Connecting the Server Cables for Both Servers 32
Connector Locations 32
To Connect the Service Processor Serial Management Port 35
To Connect the Service Processor Network Management Port 36
To Connect the Ethernet Network Cables 36
TTYA Serial Port 37
USB Ports 37
To Connect the AC Power Cable to the Server 38
Managing Cables With the CMA 38
Securing the Server Cables in the CMA 38
Dismounting the Servers 39
3. Powering On the System 41
Powering On the System for the First Time 41
ILOM System Console 41
ILOM Service Processor 42
CLIs, User Accounts, and Passwords for Connecting to the ILOM Service
Processor 42
To Power On the System for the First Time 43
To Avoid Booting the Solaris Operating System at Start Up 45
Enabling the Service Processor Network Management Port 46
Logging Into the Service Processor 46
To Log Into the Service Processor Using the Serial Management Port 47
To Configure the Service Processor Network Management Port 48
To Reset the Service Processor 51
To Log Into the Service Processor Using the Network Management Port
52
Using the Service Processor for Common Operations 53
To Power On the System 53
To Connect to the System Console 55
Contents vii
To Perform a Normal System Initialization 55
Booting the Solaris Operating System 57
To Boot the Solaris Operating System 57
To Reset the System 59
To Power Cycle the System 59
Verifying System Functionality 60
A. Updating the Firmware 61
Updating the Firmware 61
To Update the Firmware 61
B. Selecting a Boot Device 65
To Select a Boot Device 65
C. Installing the Servers With the Express Rail Rackmounting Kit 67
Slide Rail Assembly Notes for the Express Rail Rackmounting Kit 68
Installing the Servers in a Rack With Express Rails 71
To Install the Slide Rail Assemblies 71
To Insert and Lock the Server in the Rack 76
Installing the Cable Management Arm 79
Connecting the Server Cables 79
Managing Cables With the CMA 79
Dismounting the Server 79
Index 81
viii SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
ix
Figures
FIGURE 1-1 SPARC Enterprise T5120 Server 2
FIGURE 1-2 SPARC Enterprise T5220 Server 2
FIGURE 1-3 Rear Panel Cable Connectors and LEDs on the SPARC Enterprise T5120 Server 8
FIGURE 1-4 Front Panel USB Ports on the SPARC Enterprise T5120 Server 8
FIGURE 1-5 Rear Panel Cable Connectors and LEDs on the SPARC Enterprise T5220 Server 9
FIGURE 1-6 Front Panel USB Ports on the SPARC Enterprise T5220 Server 10
FIGURE 1-7 Sections of the Slide Rail Assembly on the SPARC Enterprise T5220 Server 11
FIGURE 1-8 Locating the Locks on the Slide Rail Assembly for the SPARC Enterprise T5220 Server 12
FIGURE 1-9 Cable Management Arm for Both Servers 13
FIGURE 2-1 Unlocking the Slide Rail Assembly (Either Server) 17
FIGURE 2-2 Location of the Mounting Bracket Release Button (Either Server) 18
FIGURE 2-3 Unlocking the Slide Rail Middle Section (Either Server) 19
FIGURE 2-4 Attaching a Mounting Bracket to the Chassis (Either Server) 20
FIGURE 2-5 Mounting a Slide Rail (Either Server) 21
FIGURE 2-6 Using the Slide Rail Spacing Tool to Adjust the Distance Between the Slide Rails (Either
Server) 22
FIGURE 2-7 Mounting the Chassis on the Slide Rails (Either Server) 24
FIGURE 2-8 Inserting the CMA Rail Extension Into the Rear of the Left Slide Rail (Either Server) 26
FIGURE 2-9 Mounting the Inner CMA Connector (Either Server) 27
FIGURE 2-10 Attaching the Outer CMA Connector (Either Server) 28
FIGURE 2-11 Mounting the Left Side of the Slide Rail (Either Server) 29
x SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
FIGURE 2-12 Unlocking the Slide Rail Assembly (Either Server) 30
FIGURE 2-13 Rail Mounting Bracket Release Button (Either Server) 31
FIGURE 2-14 Rear Panel Connectors on the SPARC Enterprise T5120 Server 33
FIGURE 2-15 Front Panel USB Ports on the SPARC Enterprise T5220 Server 33
FIGURE 2-16 Rear Panel Features on the SPARC Enterprise T5220 Server 34
FIGURE 2-17 Front Panel USB Ports on the SPARC Enterprise T5220 Server 34
FIGURE 2-18 Service Processor Serial Management Port – Rear Panel 35
FIGURE 2-19 Service Processor Network Management Port – Rear Panel 36
FIGURE 2-20 Service Processor Ethernet Network Ports – Rear Panel 37
FIGURE 2-21 Securing the Server Cables With the CMA and Velcro Straps (Either Server) 39
FIGURE 3-1 Rear Panel Power Connectors of a SPARC Enterprise T5120 Server 44
FIGURE 3-2 Rear Panel Power Connectors of a SPARC Enterprise T5220 Server 44
FIGURE C-1 Sections of the Express Rail Slide Rail Assembly 68
FIGURE C-2 Locating the Locks on the Slide Rail Assembly for the SPARC Enterprise T5220 Server 70
FIGURE C-3 Unlocking the Express Rail Slide Rail Assembly 72
FIGURE C-4 Express Rail Mounting Bracket Release Button 73
FIGURE C-5 Attaching an Express Rail Mounting Bracket to the Chassis 74
FIGURE C-6 Express Rail Slide Rails Orientation for Installation 75
FIGURE C-7 Attaching Express Slide Rails to the Rack 76
FIGURE C-8 Inserting Express Rail Mounting Brackets Into the Slide Rails 77
FIGURE C-9 Sliding the Express Rail Release Tab and Securing the Server in the Rack 78
xi
Tables
TABLE 1-1 Ethernet Connection Transfer Rates 7
TABLE 3-1 Disk Slot Numbers, Logical Device Names, and Physical Device Names 56
TABLE 3-2 Device Identifiers and Devices 56
xii SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
xiii
Preface
The SPARC Enterprise T5120 and T5220 Servers Installation Guide provides
instructions, background information, and reference material to help you install
SPARC
®
Enterprise T5120 and T5220 servers.
The installation instructions in this document assume that a system administrator is
experienced with the Solaris™ Operating System (Solaris OS).
Note All internal components except hard drives must be installed by qualified
service technicians only.
FOR SAFE OPERATION
This manual contains important information regarding the use and handling of this product.
Read this manual thoroughly. Pay special attention to the section “Notes on Safety” on
page xx. Use the product according to the instructions and information available in this
manual. Keep this manual handy for further reference.
Fujitsu makes every effort to prevent users and bystanders from being injured or from
suffering damage to their property. Use the product according to this manual.
xiv SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
Structure and Contents of This Manual
This manual is organized as described below:
CHAPTER 1 Preparing for Installation
Provides an installation overview for the servers.
CHAPTER 2 Installing the SPARC Enterprise T5120 and T5220 Servers
Provides instructions for installing the servers into a rack.
CHAPTER 3 Powering On the System
Provides instructions for configuring and powering on the servers and for
installing additional software.
APPENDIX A Updating the Firmware
Provides instructions for updating the service processor firmware and the
system firmware.
APPENDIX B Selecting a Boot Device
Provides instructions for selecting a boot device.
APPENDIX C Installing the Servers With the Express Rail Rackmounting Kit
Provides instructions for installing the servers into a rack with the Express rail
rackmounting kit.
INDEX
Provides keywords and corresponding reference page numbers so that the
reader can easily search for items in this manual as necessary.
Preface xv
Shipping Kit Inventory List for Both
Servers
Standard components of the SPARC Enterprise T5120 and T5220 are installed at the
factory. However, if you ordered options such as PCI cards or a monitor, these are
shipped to you separately.
Note Inspect the shipping cartons for evidence of physical damage. If a shipping
carton appears damaged, request that the carrier’s agent be present when the carton
is opened. Keep all contents and packing material for the agent’s inspection.
Verify that you have received all of the following:
Server
Either the regular rackmounting kit or the express rail rackmounting kit:
Regular rackmounting kit
Two slide rail assemblies
Slide spacing tool
Package of mounting screws and nuts in assorted sizes to fit various types of
equipment racks
Cable management arm
Two extension brackets for use with racks up to 39.5 in. (1000 mm) in depth
Express rail rackmounting kit
Two slide rail assemblies
Two inner section mounting brackets (locked inside the slide rail assemblies)
Cable management arm (CMA) shipped in different box (included only with
Express rail and CMA combination kit)
Cable fasteners installed on the CMA (included only with Express rail and
CMA combination kit)
One removable rear left attachment bracket secured to CMA with removable
tape
Ten M4x5 bracket attachment screws (only for select servers)
xvi SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
Related Documentation
The latest versions of all the SPARC Enterprise Series manuals are available at the
following Web sites:
Global Site
http://www.fujitsu.com/sparcenterprise/manual/
Japanese Site
http://primeserver.fujitsu.com/sparcenterprise/manual/
Note Product Notes is available on the website only. Please check for the recent update on
your product.
Title Description Manual Code
SPARC Enterprise T5120 and T5220
Servers Product Notes
Information about the latest product
updates and issues
C120-E458
SPARC Enterprise T5120 and T5220
Servers Overview Guide
Product features C120-E460
SPARC Enterprise T5120 and T5220
Servers Site Planning Guide
Server specifications for site planning C120-H027
SPARC Enterprise T5120 and T5220
Servers Service Manual
How to run diagnostics to
troubleshoot the server, and how to
remove and replace parts in the
server
C120-E463
SPARC Enterprise T5120 and T5220
Servers Administration Guide
How to perform administrative tasks
that are specific to the servers
C120-E464
Integrated Lights Out Manager 2.0
Users Guide
Information that is common to all
platforms managed by ILOM
C120-E474
Integrated Lights Out Manager 2.0
Supplement for SPARC Enterprise
T5120 and T5220 Servers
How to use the Integrated Lights Out
Manager (ILOM) software on the
servers
C120-E465
(Varies based
on version)
SPARC Enterprise T5120 and T5220
Servers Safety and Compliance Guide
Safety and compliance information
that is specific to the servers
C120-E461
Preface xvii
Using UNIX Commands
This document might not contain information about basic UNIX® commands and
procedures such as shutting down the system, booting the system, and configuring
devices. Refer to the following for this information:
Software documentation that you received with your system
Solaris Operating System documentation, which is at:
http://docs.sun.com
Text Conventions
This manual uses the following fonts and symbols to express specific types of
information.
* The settings on your browser might differ from these settings.
Typeface* Meaning Example
AaBbCc123 The names of commands, files and
directories; on-screen computer
output
Edit your.login file.
Use ls -a to list all files.
% You have mail.
AaBbCc123 What you type, when contrasted
with on-screen computer output
% su
Password:
AaBbCc123 Book titles, new words or
terms, words to be
emphasized.
Replace command-line
variables with real names or
values.
Read Chapter 6 in the Users
Guide.
These are called class options.
You must be superuser to do
this.
To delete a file, type
rm
filename.
xviii SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
Prompt Notations
The following prompt notations are used in this manual.
Conventions for Alert Messages
This manual uses the following conventions to show alert messages, which are
intended to prevent injury to the user or bystanders as well as property damage, and
important messages that are useful to the user.
Warning This indicates a hazardous situation that could result in death or serious
personal injury (potential hazard) if the user does not perform the procedure correctly
Caution This indicates a hazardous situation that could result in minor or moderate
personal injury if the user does not perform the procedure correctly. This signal also
indicates that damage to the product or other property may occur if the user does not perform
the procedure correctly.
Tip This indicates information that could help the user to use the product more
effectively.
Shell Prompt Notations
C shell machine-name%
C shell superuser machine-name#
Bourne shell and Korn shell $
Bourne shell and Korn shell and Korn shell superuser #
Preface xix
Alert messages in the text
An alert message in the text consists of a signal indicating an alert level followed by
an alert statement. Alert messages are indented to distinguish them from regular
text. Also, a space of one line precedes and follows an alert statement.
Caution The following tasks regarding this product and the optional products provided
from Fujitsu should only be performed by a certified service engineer. Users must not
perform these tasks. Incorrect operation of these tasks may cause malfunction.
Unpacking optional adapters and such packages delivered to the users
Also, important alert messages are shown in “Important Alert Messages” on page xx
xx SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
Notes on Safety
Important Alert Messages
This manual provides the following important alert signals:
Caution This indicates a hazardous situation could result in minor or moderate
personal injury if the user does not perform the procedure correctly. This signal also
indicates that damage to the product or other property may occur if the user does
not perform the procedure correctly.
Task Warning
Installation Electric shock
There is a potential for electric shock if the server and related equipment
are not properly grounded.
Damage
Deploy the antitilt feature on the rack before beginning an installation.
The SPARC Enterprise T5220 server weighs approximately 46 lb
(20.7 kg). Two people are required to lift and mount the system into a
rack enclosure when using the procedures in this book.
When completing a two-person procedure, always communicate your
intentions clearly before, during, and after each step to minimize
confusion.
The weight of the server on extended slide rails can be enough to
overturn an equipment rack.
Preface xxi
Product Handling
Maintenance
Warning Certain tasks in this manual should only be performed by a certified
service engineer. User must not perform these tasks. Incorrect operation of these
tasks may cause electric shock, injury, or fire.
Installation and reinstallation of all components, and initial settings
Removal of front, rear, or side covers
Mounting/de-mounting of optional internal devices
Plugging or unplugging of external interface cards
Maintenance and inspections (repairing, and regular diagnosis and maintenance)
Caution The following tasks regarding this product and the optional products
provided from Fujitsu Siemens Computers should only be performed by a certified
service engineer. Users must not perform these tasks. Incorrect operation of these
tasks may cause malfunction.
Unpacking optional adapters and such packages delivered to the users
Plugging or unplugging of external interface cards
Remodeling/Rebuilding
Caution Do not make mechanical or electrical modifications to the equipment.
Using this product after modifying or reproducing by overhaul may cause
unexpected injury or damage to the property of the user or bystanders.
xxii SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
Alert Labels
The followings are labels attached to this product:
Never peel off the labels.
The following labels provide information to the users of this product.
Fujitsu Welcomes Your Comments
We would appreciate your comments and suggestions to improve this document.
You can submit your comments by using "Reader's Comment Form".
Example: SPARC Enterprise T5220
/