American Standard 775B305.002 Installation guide

Category
Sanitary ware
Type
Installation guide
1
© 2016 AS America Inc.
Installation Instructions
Certied to comply with ASME A112.18.1
© 2016 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic
®
Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
NextGen Selectronic
®
Integrated Faucet with Optional Above-Deck
Mixing & SmarTherm
Temperature Limiter
MODEL NUMBERS
7755.1xx 775B.1xx
7755.2xx 775B.2xx
7755.3xx 775B.3xx
M965754 (9/16)
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Product No’.s & Options 2
Specications 3
Faucet Installation 3
Electrical Installation 4-5
FAQ’s / Troubleshooting 9
Parts 10
Start-up / Maintenance 6-8
2
Thank you for selecting American-Standard...the benchmark of ne quality for over 100 years. To ensure that your
installation proceeds smoothly--please read these instructions carefully before you begin.
Remove the tting and loose items from the carton. The illustration below shows all the ttings and loose items after they
have been removed from the carton. Some items may be packaged partially assembled to other items.
UNPACKING
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
1. Installation Instructions
2. Spout Assembly (less mixing)
2a. Spout Assembly (mixing)
3. Mounting Kit
4. 4" and 8" Deck plate (optional,
must be ordered separately)
5. Thermostatic Mixing Valve (optional, must be ordered separately)
6. Filter Screen
7. Assembly Parts
8. Battery Back-Up Unit (optional, must be ordered separately)
775P.400 775P.800
4
605XTMV1070
3
2
5
6
1
Deck Plate
Mixing Valve
2a
Plug-In AC
Power Kit
Hard-Wired AC
Power Kit
Multi-AC
Power Kit
PWRX
Power Kit
PK00.PACPK00.WRK
PK00.HAC PK00.MAC
DO NOT REMOVE
PROTECTIVE
FILM FROM
SENSOR EYE UNTIL
INSTALLATION IS
COMPLETE.
DO NOT REMOVE
PROTECTIVE
FILM FROM
SENSOR EYE UNTIL
INSTALLATION IS
COMPLETE.
7
PK00.BBU
Battery
Back-Up
Kit
8
POWER KITS SOLD SEPARATELY
1
© 2016 AS America Inc.
Installa tion Instr uctions
© 2016 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic
®
Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
NextGen Selectronic
®
Integrated Faucet with Optional Above-Deck
Mixing & Temperature Limiter
MODEL NUMBERS
7755.1xx 775B.1xx
7755.2xx 775B.2xx
7755.3xx 775B.3xx
M965754 (8/16)
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Product No’.s & Options 2
3
Faucet Installation 3
Electrical Installation 4-5
FAQ’s / Troubleshooting 9
Parts 10
Start-up / Maintenance 6-8
M965754 (9/16)
3
1
SPOUT ASSEMBLY
INSTALLATION; Fig. 1
1. Make sure O-RING (1) is installed in spout base.
IMPORTANT: Do not use putty when installing faucet
without escutcheon.
2. If installing DECK PLATE (2) (optional): Apply a bead
of putty to bottom edge of PUTTY PLATE (2). Install
SCREW (11) into the MOUNTING BASE OF THE
FAUCET (13) and allign SCREW (11) with HOLE (12).
3. Insert SUPPLY HOSES (3), SHANK (4) and SENSOR
CABLE (5) (only included in base model) through hole
in DECK PLATE with PUTTY PLATE (2) and mounting
surface.
4. Assemble RUBBER WASHER (7), BRASS WASHER (8)
and THREADED LOCKNUT (9) onto SHANK (4) from
underside of sink or mounting surface. Hand tighten
LOCKNUT (9).
5. Use a screwdriver to tighten SCREWS (10) on
LOCKNUT (9). Work your way around LOCKNUT (9),
tightening the screws slightly each time until all are
snug to ensure even pressure.
Roughing-in Dimensions
1. 2.5 mm Hex Wrench
(Included)
2. Adjustable Wrench
3. Plumbers Putty or Caulking
4. Phillips Screwdriver
5. Tape Measure
6. 2.0 mm Hex Wrench
(Included)
M965754 (9/16)
RECOMENDED CONTROL BOX OR
EQUIVALENT BY OTHERS
4" (102mm) SQ. X 3-1/2" (89mm) DEEP CONTROL BOX
Hubbel-RACO #256 OR EQUAL (BY OTHERS).
(Used with Hard-Wired AC Transformer)
CLEARANCE
25mm (min) - 127mm (max)
(1" min - 5" max)
FINISHED WALL
OR BACKSPLASH
126 mm
(5")
146 mm
(5-3/4")
48 mm
(1-7/8")
28 mm
(1-1/8")
3/8" COMPRESSION
CONNECTORS
174 mm
(6-7/8")
125 mm
(4-15/16")
38 mm
(1-1/2")
597 mm
(23-1/2")
39 mm
(1-1/2")
61 mm
(2-7/16")
Note: All plumbing and electrical wiring must be installed in
accordance with applicable codes, regulations and standards.
CAUTION: Use only American Standard
supplied transformers and cable sets.
Using non-AS supplied cables, or cutting,
splicing or modifying any components
will void the warranty.
RECOMMENDED TOOLS
CAUTION
Turn off hot and cold water
supplies before beginning
Fig. 2
1
2
3
4
5
10'
6
Fig. 1
10
PUTTY
(If required)
MOUNTING
SURFACE
(OPTIONAL)
TIGHTEN
SPIN NUTS
2
1
4
12
13
3
7
8
9
5
I
MPORTANT: Do not
use putty when installing
faucet without escutcheon.
IMPORTANT: Do not
use sealent on threads
11
4
M965754 (9/16)
ELECTRICAL INSTALLATION
Product Page
PWRX Power Kit
(PK00.WRK)
4
Plug-In AC Power Kit (PK00.PAC)
5
Hard-Wired AC Power Kit (PK00.HAC)
5
Multi-AC Power Kit (PK00.MAC)
5
Important: All product with standard battery come
with electrical connections preaseambled at the
factory. No further action necessary.
A
PWRX 10 YEAR BATTERY
SYSTEM; Fig. 1
PWRK
VERSION;
1. Connect PWRX BATTERY PACK (1) to SENSOR
CABLE (2).
2. Secure the connections by installing into CONNECTOR
LOCKING DEVICE (3) as shown. Rotate the END CAPS
(4) to secure the connection within the CONNECTOR
LOCKING DEVICE (3).
3. Determine the mounting location of the PWRX BATTERY
PACK (1) by marking center lines as shown.
4. Place the BRACKET (5) on the horizontal center line
and mark the location of the mounting holes to be drilled.
5. Using 1/4" diameter drill bit, drill two mounting holes
aproximately 1" deep.
6. Install the two ANCHORS (6) provided into the mounting
holes.
7. Place the BRACKET (5) over the ANCHORS (6)
and secure with the SCREWS (7) provided.
Do not overtighten.
8. Insert PWRX BATTERY PACK (1) into BRACKET (5).
7
6
5
VERTICAL
C/L
HORIZONTAL
C/L
1
BRACKET INSTALLATION
Fig. 1
1
3
2
3
4
4
5
M965754 (9/16)
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
B
AC VERSIONS (HARD-WIRED /
PLUG-IN POWER SUPPLY); Fig. 2
Important: Turn off power to outlet or control box.
1. Connect PLUG-IN AC POWER SUPPLY (5) or
10' EXTENSION CABLE (2) if using HARD-WIRED AC
TRANSFORMER (7) to SINGLE AC ADAPTER (3).
2. Connect SENSOR CABLE (4) to the other terminal of
the SINGLE AC ADAPTER (3).
3. Connect PLUG-IN AC POWER SUPPLY (5) to wall outlet,
or connect other end of 10' EXTENSION CABLE (2) to
the HARD-WIRED AC TRANSFORMER (7).
FOR HARD-WIRED VERSION;
4. Make Black and White power line connections to
HARD-WIRED AC TRANSFORMER (7) and mount
into CONTROL BOX (6).
WALL
OUTLET
4" CONTROL BOX
OR EQUIVALENT BY
OTHERS (6)
Fig. 2
3
4
1
5
BLACK & WHITE
POWER
CONNECTIONS
10' EXTENSION
7
CONNECTOR NOT
USED IN THIS
INSTALLATION
7
6
2
Unit #1
(Already Installed)
Fig. 3
Unit #2 Unit #3 Unit #4
1
2
4
3
MAXIMUM OF 15 UNITS PER TRANSFORMER.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
BLACK & WHITE
POWER
CONNECTIONS
C
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3
Important: Disconnect the rst unit’s Multi-AC Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to Figure 2 (above).
For subsequent Units, refer to instructions below...
1. Connect one end of the 10' EXTENSION (1) to the available terminal of the previous unit’s MULTI-AC ADAPTER (2), and
the other end to the single terminal of the current unit’s MULTI-AC ADAPTER (3).
2. Connect SENSOR CABLE (4) to either of the two available terminals of MULTI-AC ADAPTER (3).
3. Repeat Steps above for each additional Unit, for a Max. of 15 Units on one AC POWER SUPPLY.
Recommended Control Box or Equivalent
by others
4" (102 mm) SQ. x 3-1/2" (89 mm) DEEP
ELECTRICAL BOX Hubbel-RACO #256
OR EQUAL (BY CONTRACTOR).
6
M965754 (9/16)
D
MAKE WATER SUPPLY
CONNECTIONS; Fig. 4
1. Turn off hot and cold water supplies before beginning.
2. Place each SCREEN FILTER (3) on each wall supply
outlet. Be sure that SCREEN FILTER (3) is inserted
in the correct direction. (See Illustration)
3. Connect HOT FLEXIBLE SUPPLY (marked with red
stripe) (1) to hot water control stop (4). Connect COLD
FLEXIBLE SUPPLY (marked with blue stripe) (2) to cold
water control stop (5). Use adjustable wrench to tighten
connections. Do not over tighten.
4. Faucet supplies are 24" long from faucet base.
Note; If additional supply length is required, installer
must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long, loop
as illustrated to avoid kinking.
Fig. 4
Fig. 5
DETECTION
ZONE
PROTECTIVE FILM
IMPORTANT: Do not
use sealent on threads
1
2
3
COLD
HOT
(3) SCREEN
FILTER
BULGE
SIDE DOWN
Fig. 1
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Thermostatic Mixing Valve
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-80 0-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
605XTMV
Specifications
Installation
Adjust Temperature
Service
Replacement Parts
1
2
3
3
4
No. M968808
HOT
SUPPLY
COLD
SUPPLY
TEE
FITTING
Optional Mixing Valve
(Sold Separately)
TEMPERED
WATER SUPPLY
COLD
WATER
5
4
E
INSTALL OPTIONAL MIXING
VALVE; Fig. 5
Note: An optional Thermostatic Mixing Valve (sold
separately) may be installed on faucets 775X.1XX &
775X.2XX in addition to Above Deck Mixing valve.
See setup diagram Fig. 5.
Te etting is not supplied with Faucet or Thermostatic
Mixing valve and must be purchased separately. If faucet
inlet hoses will not reach water supplies, longer hoses
must be purchased separately.
For complete detailed installation and operating
instructions, see installations instructions (No. M968808)
supplied with Thermostatic Mixing Valve.
MAINTENANCE
A
HAND WASH SENSOR
OPERATION; Fig. 1
REMOVE PROTECTIVE FILM FROM SENSOR EYE
WHEN INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water immediately
starts to ow. Water ow will stop 1.5 seconds after user is
out of sensor range. This Comfort delay allows the user to
comfortably move their hands without the water turning off.
As a precaution, a Safety Timer will turn off the water, after
the sensor has been blocked for 59 seconds. The water will
stay off until the blockage is removed from the detection
zone.
The Comfort and Safety time settings can be adjusted using
the Optional Remote Control (605XRCT).
7
M965754 (9/16)
B
REPLACE BATTERY; Fig. 5, 7
1. Remove COVER SCREW (1) and lift COVER (15) off.
2. Disconnect SENSOR CABLES (6) and (7) from the
BATTERY and SOLENOID VALVE. (Fig. 7)
3. Push BATTERY (17) forward and Pull it out. (Fig. 5)
4. Replace the new battery with the same placement.
(Insert terminal side rst)
C
REPLACE SENSOR; Fig. 5, 6, 7
1. Remove COVER SCREW (1) and lift COVER (15) off.
2. Disconnect SENSOR CABLES (6) and (7) from the
BATTERY and SOLENOID VALVE. (Fig. 7)
3. Remove the AERATOR RETAINER SCREW (2) and
BODY FIXATION SCREW (3). (Do not remove SPOUT
TUBE 16)
4. FOR ABOVE DECK MIXING FAUCETS
Remove FIXATION SCREW (13). Pull the HANDLE
ASSEMBLY (11) to remove the shaft from the
MANIFOLD (14).
5. Lift BODY (12) off of MANIFOLD (14).
6. Remove SENSOR (9) by carefully pushing on the face
of the sensor. Once removed, peal the SENSOR
ADHESIVE off of the BODY and clean the remaining
residue.
7. To install the new SENSOR, peal the paper liner from the
double sided tape and carefully place the SENSOR in its
original position so that the WIRES point upward. Press
and hold the sensor for 5 - 10 seconds to ensure it sticks
properly.
Note: To prevent damage to the wires, verify that they
are tucked inside the hooks which are located on both
sides of the sensor.
8. FOR ABOVE DECK MIXING FAUCETS
Slide SPOUT (12) over the MANIFOLD (14) being careful
to avoid interference between the SPOUT TUBE (16) and
SENSOR (9). Tighten the BODY FIXATION SCREW (3).
Insert HANDLE ASSEMBLY (11) into the MANIFOLD (14)
and secure it with FIXATION SCREW (13). Move the
SPOUT TUBE (16) and AERATOR RETAINER (2) into
position and tighten the AERATOR RETAINING SCREW
(2) to secure the assembly. Reconnect SENSOR
CABLES (6 and 7) to the BATTERY and SOLENOID
VALVE. Install COVER (15) and secure it with COVER
SCREW (1). Tuck extra lengths of wire in the empty
space located above FIXATION SCREW (13)
9. Slide SPOUT (12) over the MANIFOLD (14) being careful
to avoid interference between the SPOUT TUBE (16) and
SENSOR (9). Tighten the BODY FIXATION SCREW (3).
Move the SPOUT TUBE (16) and AERATOR RETAINER
(2) into position and tighten the AERATOR RETAINING
SCREW (2) to secure the assembly. Reconnect
SENSOR CABLES (6 and 7) to the BATTERY and
SOLENOID VALVE. Install COVER (15) and secure it
with COVER SCREW (1). Tuck extra lengths of wire in
the empty space located above FIXATION SCREW (13)
15
16
2
1
4
9
14
3
13
7
Fig. 5
Fig. 6
Fig. 7
12
11
10
6
12
17
8
D
CHANGE SENSOR RANGE; Fig. 5, 6, 7
1. Remove the COVER SCREW (1).
2. Remove the COVER (15).
3. Disconnect the BLACK POWER SUPPLY CONNECTOR (7)
and reconnect. Fig. 7.
4. While the SENSOR CONTROL LED (9) is blinking slowly,
place your hand 1 - 2 in. (25.4-50.8mm) in front of the sensor.
5. When the LED stops blinking and stays “ON”, move your hand
to the desired position and hold in place until the LED begins
to blink again.
6. Once the SENSOR CONTROL LED (9) begins to blink again,
remove your hand from the detection zone. When the ashing
stops, the detection distance is set.
7. Reassemble the COVER (15) and secure it with COVER
SCREW (1).
E
ADJUST HOT LIMIT STOP; Fig. 12, 14
To reduce the amount of hot water that can mix with cold, the
installer can adjust hot limit stop (Four different settings).
1. Rotate LEVER HANDLE (3) counter-clockwise to its stop
position (100% cold).
2. Remove LEVER SCREW (5) and pull off the LEVER
HANDLE (3).
3. Pull out LIMIT STOP (1) from the VALVE STEM (5).
4. Rotate LIMIT STOP (1) between the shaded area and insert
back onto VALVE STEM (5).
5. Each notch on the LIMIT STOP (1) will reduce the amount of
hot water by approximately 3%. For example, the 2nd notch will
have 97% of maximum temp, the 3rd notch will have 94% and
the fourth will be 91%.
6. Replace LEVER HANDLE (3), LEVER HANDLE SCREW (5)
and tighten.
F
ADJUST MAXIMUM OUTLET
TEMPERATURE; Fig. 13
1. With the COVER off, the installer can reduce the maximum
mixed water temperature by turning the VALVE CAP (4)
clockwise with a screwdriver.
WARNING
Do not turn the VALVE CAP (4) More than 1 turn.
The maximum mixed water temperature can not be
increased due to ASSE 1070 requirements.
G
GENERAL CLEANING
1. Only use a damp, soft cloth to clean the spout and the sensor.
2. For tougher dirt, use a soft cloth with diluted dish washing
detergent. Wipe the area using a wet cloth and dry using a
soft cloth.
CAUTION
Do not scratch the sensor when cleaning. Avoid using
any abrasives or harsh detergents or chemicals.
M965754 (9/16)
Fig. 12
Fig. 13
Fig. 14
4
1
2
3
5
9
M965754 (9/16)
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names listed herein are trademarks of AS America, Inc. ©2016
To learn more about American Standard Selectronic
®
Products visit our website at:
www.americanstandard-us.com or e-mail us at: [email protected]
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
1 1
2 2
YES
YES
NO
NO
YES
NO
OPEN EXTERNAL SUPPLY STOPS.
CRITICALLY LOW BATTERY.
INSTALL NEW BATTERY.
DEAD BATTERY. INSTALL
NEW BATTERY. REPEAT.
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
ARE EXTERNAL SUPPLY
STOPS OPEN?
REPEATED DOUBLE FLASH
ON SENSOR?
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
REPLACE SOLENOID
YES
YES
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
NO
FULLY OPEN EXTERNAL SUPPLY STOPS BY
TURNING COUNTER CLOCKWISE.
INSPECT FILTER ASSEMBLY, AERATOR AND
SOLENOID VALVE. REMOVE, CLEAN AND INSERT
BACK TO ORIGINAL POSITION.
CHECK FOR BLOCKAGE
ARE EXTERNAL SUPPLY STOPS FULLY
OPEN?
REPLACE SOLENOID
WATER IS CONTINUOUSLY RUNNING
LOW FLOW ISSUES
10
M903708-0070A
SHAFT
M954480-0070A
SOLENOID VALVE
M910297-0070A
0.35 GPM AERATOR
M910290-0070A
0.5 GPM AERATOR
M964171-0070A
1.5 GPM AERATOR
M962061-0070A
MOUNTING KIT
775P400.002
4" ESCUTCHEON
775P800.002
8" ESCUTCHEON
M910513-0070A
FILTER SCREENS (2)
M970151-0020A
LEVER HANDLE
M924107-0070A
SENSOR
M950338-0070A
POWER SUPPLY
M950511-0070A
10' EXTENSION
M950511-0070A
10' EXTENSION
M950361-0070A
PWRX BATTERY PACK
M964455-0070A
BRACKET
A923654-0070A
BATTERY 6V CR-P2
M950399-0070A
SINGLE AC
ADAPTER
M950512-0070A
MULTI-AC ADAPTER
M950520-0070A
POWER SUPPLY
PWRX Power Kit
PK00.WRK
Plug-In AC
Power Kit
PK00.PAC
Hard-Wired AC
Power Kit
PK00.HAC
Multi-AC
Power Kit
PK00.MAC
CR-P2 Lithium Battery
7755. Series
A912746-0070A
SPOUT O-RING
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names listed herein are trademarks of AS America, Inc. ©2016
To learn more about American Standard Selectronic
®
Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
M970210-0070A
SCREW
M923155-0070A
HOT LIMIT STOP
M950399-0070A
SINGLE AC ADAPTER
M950360-0070A
CONNECTOR
LOCKING
DEVICE
M950360-0070A
CONNECTOR
LOCKING DEVICE
M950360-0070A
CONNECTOR
LOCKING DEVICE
M923290-0070A
HOT/COLD
SUPPLY HOSES
M965754 (9/16)
MODEL NUMBERS
7755.1xx 775B.1xx
7755.2xx 775B.2xx
7755.3xx 775B.3xx
NextGen Selectronic
®
Integrated Faucet with Optional Above-Deck
Mixing & SmarTherm
Temperature Limiter
Appropriate finish code
POLISHED CHROME 002
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

American Standard 775B305.002 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI