Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Also available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue, or visit our website.
ThisproductconformstoBSEN60669-2-1andBSEN55015:1993
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.6ampsovercurrent,1kVovervoltage.Pleaseensure
thatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Plated rotary 2-way (push-on, push-off)
Dimmer
for wire wound transformer loads
DP1D 250WI DP1D 400WI DP1D 630WI DP2D 160WI
DANLERSplatedrotary2-way‘leadingedge’dimmersareavailable
aseitheronegang(250,400or630W)ortwogang(160W)dimmers.
They are supplied on a square plate except for the DP1D 630WI
dimmerwhichissuppliedonarectangularplate.
Presstheknobtoturnthelamponandoff,rotateitclockwisetobrighten
thelampandanti-clockwisetodimit.
The lamp can be switched from other locations by using standard
2-way and intermediate wall switches. It cannot be dimmed from
another location and no other dimmer should be connected into the
sameswitchcircuit.
These plated rotary dimmers can control wire-wound transformers
(inductiveload)usedtodimlowvoltagelamps.
Eachgangofeachdimmerswitchcandimwithinthefollowingloading
limits,theyneedthefollowingwallboxdepthandaresuppliedonthe
followingplateshape.Aguide-linemaximumnumberoftransformers
(TXs)isalsoincluded,butthisdependsonthequalityofthetransformers
being used.
Part Code Gang Min Max Box depth Plate style Max TXs
(per gang) (per gang) (per gang)
DP1D250WI 1 60W 250W 16mm Square 6
DP1D400WI 1 60W 400W 40mm Square 8
DP1D 630WI 1 60W 630W 25mm Rectangular 12
DP2D160WI 2 40W 160W 16mm Square 4
23/09/11 INS916 DPxDWI
Loading
Rotary dimmer ‘buzzes’:
• Thiscanoccurwithleadingedgedimmers.
Rotary dimmer gets warm:
• Thiscanoccurwithdimmers,especiallywhencontrollinglargeloads.
Troubleshooting