Triax CCE 210 Assembly Instructions Manual

Type
Assembly Instructions Manual
TRIAX - your ultimate connection
A
CLASS
KLASSE
Assembly Instructions
Art. No. 325166 GB
CCE 210
Head-End Digital Encoder
- 2 - CCE 210
Contents
1 Safety regulations and notes ........................................................................4
2 General information ....................................................................................5
2.1 Packing contents ..............................................................................5
2.2 Meaning of the symbols used ............................................................5
2.2 Technical data .................................................................................5
2.3 Description ......................................................................................7
Software versions .............................................................................7
3 Assembly ....................................................................................................8
3.1 Installing the cassette ........................................................................8
3.2 EMC regulations ..............................................................................9
3.3 Cassette overview ..........................................................................10
3.4 Connecting the cassette ..................................................................10
4 The control panel at a glance .....................................................................11
4.1 Menu items ...................................................................................11
4.2 Control panel ................................................................................11
5 Programming ............................................................................................12
5.1 Programming procedure .................................................................12
5.2 Programming the cassette ...............................................................15
Selecting the cassette .....................................................................15
Ethernet parameters .......................................................................16
IP address of the cassette .............................................................16
Address range (subnet mask) .......................................................17
Address of the gateway ...............................................................17
UDP port ...................................................................................18
Output signal path .........................................................................18
Output signal path "ASI" .............................................................18
ASI transfer rate .........................................................................19
ASI options ................................................................................19
Output signal path "IP MPTS"/"IP SPTS" ........................................20
Transmission protocol ..................................................................21
Port number ...............................................................................21
Quantity of data packets .............................................................22
Forward error correction ..............................................................22
Transmission channel .................................................................22
Output IP address .......................................................................23
Input parameter .............................................................................23
Data rate of the video signal ........................................................24
- 3 - CCE 210
Video signal type ........................................................................24
TV standard ...............................................................................25
Aspect ratio ...............................................................................25
Sharpness ..................................................................................25
Teletext option ............................................................................26
Audio signal type and bit rate ......................................................26
Level of the audio signal ..............................................................27
Programme number (SID - Service ID) ............................................27
Channel name ............................................................................27
ASI station filter .............................................................................28
Transport stream ID and ORGNET ID ...............................................30
NIT ..............................................................................................30
Factory reset .................................................................................31
Saving settings .............................................................................31
6 Final procedures ........................................................................................32
6.1 Combination with other cassettes .....................................................32
- 4 - CCE 210
1 Safety regulations and notes
• Assembly,installationandservicingshouldbecarriedoutbyauthorised
electricians.
• Switchofftheoperatingvoltageofthesystembeforebeginningwithassem-
bly or service work or pull out the mains plug.
• Donotperforminstallationandserviceworkduringthunderstorms.
• Installthesystemsoitwillnotbeabletovibrate
- inadust-free,dryenvironment
- insuchamannerthatitisprotectedfrommoisture,fumes,splashingwa-
ter and dampness
- somewhere protected from direct sunlight
- not within the immediate vicinity of heat sources
- in an ambient temperature of 0 °C to +50 °C. In case of the formation of
condensation wait until the system is completely dried.
• Ensurethatthehead-endstationisadequatelyventilated.Donotcoverthe
ventilation slots.
• Bewareofshortcircuits
• Noliabilityisacceptedforanydamagecausedbyfaultyconnectionsor
inappropriate handling.
• Observetherelevantstandards,regulationsandguidelinesontheinstalla-
tion and operation of antenna systems.
• ThestandardsIEC/EN/DINEN50083resp.IEC/EN/DINEN60728must
be observed.
For further information please read the assembly instructions for the head-
end station used.
• Test the software versions of the head-end station and the cassette and
update them if necessary. The current software versions can be found at
"www.triax.com".
Take action to prevent static discharge when working on the device!
Electronic devices should never be disposed of in the household rubbish. In
accordance with directive 2002/96/EC of the European Parliament and the
European Council from January 27, 2003 which addresses old electronic and
electrical devices, such devices must be disposed of at a designated collection
facility. At the end of its service life, please take your device to one of these
public collection facilities for proper disposal.
- 5 - CCE 210
2 General information
2.1 Packing contents
1 Cassette CCE 210
1BNCcable 1LANcable(RJ45)
1Briefassemblyinstructions 1 CD (assembly instructions)
2.2 Meaning of the symbols used
Important note
> General note
• Performingworks
2.2 Technical data
The devices meet the following EU directives:
73/23/EWG,89/336/EWG
The product fulfils the guidelines and standards for CE labelling.
Unless otherwise noted all values are specified as "typical".
CVBS Video Input:
Standard: .....................................................................DIN EN 50049-1
Input level: .....................................................................................1 V
pp
Input impedance: ............................................................................ 75 Ω
Frequencyrange: ........................................................... 20Hz…5MHz
S-Video (Y/C) Input:
Standard: .....................................................................DIN EN 50049-1
Input level:
Y (Luminance) ................................................................................. 1 V
pp
C (Chrominance) ............................................................................1 V
pp
Input impedance: ............................................................................ 75 Ω
Frequencyrange: ........................................................... 20Hz…5MHz
Audio Input:
Standard: .....................................................................DIN EN 50049-1
Input level: ..............................................................................500 mV
rms
Input impedance: ...........................................................................10 k
Frequencyrange: ........................................................... 20Hz…15kHz
- 6 - CCE 210
Encoder:
Transport stream: ..............................................MPEG2 (ISO/IEC 13818-1)
Output data rate: .......................................................2Mbit/s…15Mbit/s
Video data stream: .......................................... MPEG2 (ISO/IEC 13818-2)
Audio data stream: ........................................... MPEG1 (ISO/IEC 11172-3)
Audio data rate: ........................................................192kb/s…384kb/s
ASI Interfaces
Standard: .....................................................................DIN EN 50083-9
Format: ................................................................MPEG ISO IEC 13818-1
max. data rate .......................................................................108 Mbit/s
User data rate: ................................................................. 2…90Mbit/s
Impedance: .................................................................................... 75
Level (input / output): ..................................................... 800 mV
pp
± 10%
Rise/Fall Time: ..............................................................< 1.2 ns (20-80%)
Reflexion loss (input): ........................................... >17dB(5…270MHz)
LAN Interface
Standard: .................................................................10/100/1000MB/s
Transport streams: .................... SPTS (Single Programme Transport Stream),
MPTS (Multi Programme Transport Stream)
Protocols: .......................................................... UDP(UserDataProtocol),
RTP (Real-Time Transport Protocol)
Connections:
Audio inputs: ...................................................................4 Cinch sockets
Video inputs: ..................................................................2Cinchsockets,
2 S-Video sockets (Mini-DIN)
LAN: ................................................................................1RJ45socket
ASI input: .................................................................1BNCsocket,75
ASI output: ................................................................1BNCsocket,75
Connection strip (10-pin): .........................................
for supply voltages and
control circuit
RS-232 socket: ....................................................... serial update interface
Remote maintenance
Remotely controllable (via
CCRS 1000
*): ................................................yes
Remoteupdate(viaBEflash*): ..............................................................yes
(* and a corresponding management unit)
- 7 - CCE 210
2.3 Description
In the cassette CCE 210 two analogue audio and video signals are converted
into MPEG2 data streams (transport streams).
The transport streams are emitted via the LAN interface or the ASI output.
Thecassetteisequippedwithtwostereo/audioinputs,two(S-)videoinputs
and one ASI data stream input. The fed in analogues signals are digitized and
supplied to an encoder that encodes them in real time.
The stereo audio signals are transferred via an adjustable amplifier to the
encoder. The bit rates are adjustable. A transport stream fed via the ASI input
socket will be inserted into the transport streams of the encoded analogous
signals. In this way it is possible to connect several
CCE 210
in series.
AttheASIoutputsockets(BNC)atransportstreamisprovidedaccordingto
ISO/IEC 13818-1. Alternatively one IP MPTS data stream or two IP SPTS data
streams(equippedwithIPaddresses)canbeprovidedatthenetworksocket.
The cassette is designed for use in head-end systems CSE 3300.
Software versions
Cassette
After activating the cassette the software version of the cassette is displayed
(see page 15).
Control unit
To operate these cassettes the software version of the control unit must be
"V43" or higher. Approx. 5 minutes after the last keypress the software version
of the control unit is displayed.
- 8 - CCE 210
Ifnecessary, youcanactivatetheindicationofthesoftwareversionof the
control unit manually:
• Pressanytwokeysonthecontrolunitofthehead-endstationsimultaneously
untilthedisplaygoesdarkandthesoftwareversion,e.g.
"
V 43
"
appears
.
3 Assembly
3.1 Installing the cassette
Ensure the head-end station is mounted so it will not be able to vibrate.
Avoid,forexample,mountingthehead-endstationontoaliftshaftorany
other wall or floor construction that vibrates in a similar way.
Beforeinstallingorchangingacassetteunplugthepowercablefromthe
mains power socket.
• Removethefasteningscrews1 of an unoccupied slot from the bracket of
the head-end station.
• Insertthecassetteinthisslotandpushitintothehousing.
• Alignthecassetteandapplyslightpressuretoconnectittotheconnections
of the board and the HF bus bar.
• Fastenthecassettewiththescrews1.
1
1
- 9 - CCE 210
3.2 EMC regulations
To comply with the current EMC regulations, it is necessary to connect the lines
leading in and out of the head-end station using cable terminals.
When mounting the cassette in a head-end station which is installed in a 19"
cabinet, make sure the connections leading in and out for the 19" cabinet are
made using cable terminals.
CLASS
KLASSE
The attenuation of shielding of the connection lines for ASI and antenna must
meet the requirements for "Class A".
• Inserttherequirednumberofcableterminalsintheopeningsprovidedin
the head-end station or in the 19
"
cabinet.
Tighten the nuts on the cable terminals until the teeth on the lock washer have
penetrated the exterior coating and a good connection is made between the hous-
ing and cable terminals.
- 10 - CCE 210
3.3 Cassette overview
12
13
11
10
9
8
7
6
5
4
3
2
1
1 D-SUBsocket"RS232"
2 Audio input R AV1 (Cinch)
3 Audio input L AV1 (Cinch)
4 Video input AV1 (Cinch)
5 S-Video input AV1 (Mini-DIN)
6 ASIoutput(BNC)
7 ASIinput(BNC)
8 Ethernetsocket(RJ45)
9 Audio input R AV2 (Cinch)
0 Audio input L AV2 (Cinch)
! Video input AV2 (Cinch)
@ S-Video input AV2 (Mini-DIN)
# MAC Address (at the frame)
The operating software of the cassette can be updated via
the9-pinD-SUBsocket"RS232"usingaPCornotebookand
the software "BE-Flash". You can find the current operating
software on the website "www.
triax.com
".
3.4 Connecting the cassette
• Connect the
peripheral devices via cable terminals to the input sockets
"Video" 4/! or "S-Video" 5/@, "Audio R" 2/9 and "Audio L"
3/0 of the channel strips "A" and "B".
—> Connect a mono audio signal to input "Audio L"
3/0
.
• Connectthe
ASI input
7
and the
ASI output 6
to the peripheral devices
-
or
• connecttheLANsocket8.
• Connectthehead-endstationtothemains.
- 11 - CCE 210
4 The control panel at a glance
4.1 Menu items
Program the cassette using the buttons on the control unit of the head-end sta-
tion. The two-line display of the control unit then shows the menus.
Use the key to select the following main menu items:
– Cassette
– Ethernet
– Output
– Input
– ASI
– TS/ONID
– Factory reset
4.2 Control panel
The key pad on the head-end station is used to scroll through the menus:
scrolls forward through the menus.
scrolls backward through the menus.
select parameters in the menus
selects sub-menus
setvalues,.
saves all entries.
BE-Remote
V43
please wait . . .
- 12 - CCE 210
5 Programming
5.1 Programming procedure
Bedienhinweise
"blättert" Menüs vorwärts.
"blättert" Menüs rückwärts.
wählen die Eingabeposition
wählt Untermenü
stellen Werte ein,.
speichert alle Eingaben.
1 zeigt die Eingabeposition
Operating Hints
scrolls forward through the menu.
scrolls backward through the menu.
select the enter position.
selects a submenu.
set values and triggers actions.
saves all entries.
1 shows the enter position
BE–Remote V 43
Bx 2
V 3
ENCODER
Bx 2
0x0001,0100
TS/ONID
Bx 1
……
……
……
Bx 3
……
> 2 sec. = abbrechen / cancel
……
……
t > 10 s
Bx 2
off =>
ETHERNET
Options
stat
DHCP
Bx 2
192.168.
IP-ADDR
0.128
Bx 2
255.255.
IP-MASK
255. 0
Bx 2
192.168.
IP-GATEWAY
0. 1
Bx 2
60000
UDP-PORT
A
B
Ein/On
Bx 2
ASI
ASI
OUTPUT
=>
IP MPTS
IP SPTS
IP MPTS
IP SPTS
nur/only
IP SPTS
Bx 2
108000 KBits
ASI RATE
Bx 2
188 pos.
/204
/neg.
/burst
ASI OPTION
cont.
IP 1
UDP
/RTP
1…7
/ 10/09 AnnexB /
/ 20/19 AnnexB
1…7
/ 10/09 AnnexB /
/ 20/19 AnnexB
/RTP
MODE/PORT
1234
Bx 2
AV 1
INPUT
=>
Bx 2
Filter
ASI
off
on
/AV 2
AV 1/2
5 Mbps
BITRATE
AV 1/2
Composite
INPUT
AV 1/2
PAL BG
NORM
4.43 MHz
AV 1/2
4:3
ASPECT
AV 1/2
normal
SHARPNESS
AV 1/2
Stereo
AUDIO
256 kbps
AV 1/2 VOLUME
0 dB
AV 1/2
1
PRG-NUM
(0x0020. . . )
AV 1/2
PROG 1
NAME
/S-Video
/Audio only/2…15/off
/PAL N
/16:9
/sharp/soft
AV 1/2
ON
TELETEXT
/OFF
/Joint/Dual/Mono L
/256/320/384
1…255 !
-11…+11
! = Programmnummer
ist bereits belegt
! = Programme number
is already in use
IP 1
7 off
PKTS/FEC
IP 1
227. 40.
OUT-IP
50. 60
IP 2
UDP
RTP
MODE/PORT
1234
IP 2
7 off
PKTS/FEC
IP 2
227. 40.
OUT-IP
50. 61
Services entfernen / hinzufügen
Removing / activating services
nächster Service (Programm)
next service (station)
on / off
on / off
01/07ASI TV +
Das Erste
Bx 2
off
NIT
M
B
A
Bx 2
Defaults
FACTORY
=>
Bx 2
STORE
FACTORY
=> M
auf Werkseinstellung
zurücksetzen und speichern
reset to factory defaults
and store
REMOTE
- 13 - CCE 210
Bedienhinweise
"blättert" Menüs vorwärts.
"blättert" Menüs rückwärts.
wählen die Eingabeposition
wählt Untermenü
stellen Werte ein,.
speichert alle Eingaben.
1 zeigt die Eingabeposition
Operating Hints
scrolls forward through the menu.
scrolls backward through the menu.
select the enter position.
selects a submenu.
set values and triggers actions.
saves all entries.
1 shows the enter position
BE–Remote V 43
Bx 2
V 3
ENCODER
Bx 2
0x0001,0100
TS/ONID
Bx 1
……
……
……
Bx 3
……
> 2 sec. = abbrechen / cancel
……
……
t > 10 s
Bx 2
off =>
ETHERNET
Options
stat
DHCP
Bx 2
192.168.
IP-ADDR
0.128
Bx 2
255.255.
IP-MASK
255. 0
Bx 2
192.168.
IP-GATEWAY
0. 1
Bx 2
60000
UDP-PORT
A
B
Ein/On
Bx 2
ASI
ASI
OUTPUT
=>
IP MPTS
IP SPTS
IP MPTS
IP SPTS
nur/only
IP SPTS
Bx 2
108000 KBits
ASI RATE
Bx 2
188 pos.
/204
/neg.
/burst
ASI OPTION
cont.
IP 1
UDP
/RTP
1…7
/ 10/09 AnnexB /
/ 20/19 AnnexB
1…7
/ 10/09 AnnexB /
/ 20/19 AnnexB
/RTP
MODE/PORT
1234
Bx 2
AV 1
INPUT
=>
Bx 2
Filter
ASI
off
on
/AV 2
AV 1/2
5 Mbps
BITRATE
AV 1/2
Composite
INPUT
AV 1/2
PAL BG
NORM
4.43 MHz
AV 1/2
4:3
ASPECT
AV 1/2
normal
SHARPNESS
AV 1/2
Stereo
AUDIO
256 kbps
AV 1/2 VOLUME
0 dB
AV 1/2
1
PRG-NUM
(0x0020. . . )
AV 1/2
PROG 1
NAME
/S-Video
/Audio only/2…15/off
/PAL N
/16:9
/sharp/soft
AV 1/2
ON
TELETEXT
/OFF
/Joint/Dual/Mono L
/256/320/384
1…255 !
-11…+11
! = Programmnummer
ist bereits belegt
! = Programme number
is already in use
IP 1
7 off
PKTS/FEC
IP 1
227. 40.
OUT-IP
50. 60
IP 2
UDP
RTP
MODE/PORT
1234
IP 2
7 off
PKTS/FEC
IP 2
227. 40.
OUT-IP
50. 61
Services entfernen / hinzufügen
Removing / activating services
nächster Service (Programm)
next service (station)
on / off
on / off
01/07ASI TV +
Das Erste
Bx 2
off
NIT
M
B
A
Bx 2
Defaults
FACTORY
=>
Bx 2
STORE
FACTORY
=> M
auf Werkseinstellung
zurücksetzen und speichern
reset to factory defaults
and store
- 14 - CCE 210
Bedienhinweise
"blättert" Menüs vorwärts.
"blättert" Menüs rückwärts.
wählen die Eingabeposition
wählt Untermenü
stellen Werte ein,.
speichert alle Eingaben.
1 zeigt die Eingabeposition
Operating Hints
scrolls forward through the menu.
scrolls backward through the menu.
select the enter position.
selects a submenu.
set values and triggers actions.
saves all entries.
1 shows the enter position
BE–Remote V 43
Bx 2
V 3
ENCODER
Bx 2
0x0001,0100
TS/ONID
Bx 1
……
……
……
Bx 3
……
> 2 sec. = abbrechen / cancel
……
……
t > 10 s
Bx 2
off =>
ETHERNET
Options
stat
DHCP
Bx 2
192.168.
IP-ADDR
0.128
Bx 2
255.255.
IP-MASK
255. 0
Bx 2
192.168.
IP-GATEWAY
0. 1
Bx 2
60000
UDP-PORT
A
B
Ein/On
Bx 2
ASI
ASI
OUTPUT
=>
IP MPTS
IP SPTS
IP MPTS
IP SPTS
nur/only
IP SPTS
Bx 2
108000 KBits
ASI RATE
Bx 2
188 pos.
/204
/neg.
/burst
ASI OPTION
cont.
IP 1
UDP
/RTP
1…7
/ 10/09 AnnexB /
/ 20/19 AnnexB
1…7
/ 10/09 AnnexB /
/ 20/19 AnnexB
/RTP
MODE/PORT
1234
Bx 2
AV 1
INPUT
=>
Bx 2
Filter
ASI
off
on
/AV 2
AV 1/2
5 Mbps
BITRATE
AV 1/2
Composite
INPUT
AV 1/2
PAL BG
NORM
4.43 MHz
AV 1/2
4:3
ASPECT
AV 1/2
normal
SHARPNESS
AV 1/2
Stereo
AUDIO
256 kbps
AV 1/2 VOLUME
0 dB
AV 1/2
1
PRG-NUM
(0x0020. . . )
AV 1/2
PROG 1
NAME
/S-Video
/Audio only/2…15/off
/PAL N
/16:9
/sharp/soft
AV 1/2
ON
TELETEXT
/OFF
/Joint/Dual/Mono L
/256/320/384
1…255 !
-11…+11
! = Programmnummer
ist bereits belegt
! = Programme number
is already in use
IP 1
7 off
PKTS/FEC
IP 1
227. 40.
OUT-IP
50. 60
IP 2
UDP
RTP
MODE/PORT
1234
IP 2
7 off
PKTS/FEC
IP 2
227. 40.
OUT-IP
50. 61
Services entfernen / hinzufügen
Removing / activating services
nächster Service (Programm)
next service (station)
on / off
on / off
01/07ASI TV +
Das Erste
Bx 2
off
NIT
M
B
A
Bx 2
Defaults
FACTORY
=>
Bx 2
STORE
FACTORY
=> M
auf Werkseinstellung
zurücksetzen und speichern
reset to factory defaults
and store
- 15 - CCE 210
5.2 Programming the cassette
—> Pressing the button for longer than 2 seconds cancels the
programming procedure. This takes you back to the programme
item "Selecting the cassette" from any menu. Any entries that have
not been saved are reset to the previous settings.
—> Entries in the menus can be saved by pressing the key. You are
taken back to the "Selecting the cassette" menu item.
—> The parameters and functions to be set are underlined (Cursor).
• Switchonthehead-endstation.
—> The display shows the software version (e.g. V 43)
—> The processor reads the
cassettes
data (approximately 10 sec-
onds).
BERemote V 43
t > 10 s
Ein/On
Selecting the cassette
• Ifnecessaryselectthecassettetobeprogrammedbyrepeatedlypressing
the button (e.g. Box 2).
—>
The display shows e.g. the menu "Bx 2 ENCODER":
"Bx 2" stands for slot 2
"
ENCODER
" type of cassette
"V 2" software version of the cassette
Bx 2
V 2
ENCODER
Bx 1
……
……
……
Bx 3
……
……
……
• Pressthe button.
- 16 - CCE 210
—> The "Ethernet parameters" – "ETHERNET" main menu is activated
.
—> IfyoudonotwanttodoEthernetsettings,pressthe but-
ton.
The "Output signal path" "OUTPUT" main
menu is activated
(page 18).
Ethernet parameters
In this menu you specify whether the Ethernet parameters for the prospectively
intendedcontrolofthecassetteareentered…
– automatically by a connected server ("DHCP"),
– manually via the menu ("stat")
– or whether you will not use the Ethernet output ("off").
Toassignthecassetteuniquely,eachIPTVcassettemustbeallocateditsown
IP address.
Bx 2
stat
ETHERNET
=>
Bx 2
DHCP
ETHERNET
=>
Bx 2
off
ETHERNET
=>
• Pressthe buttonstoselect…
– manual setting ("stat")oftheEthernetparameter,
– automatic setting ("DHCP") of the Ethernet parameter or
– to deaktivate Ethernet ("off").
• Pressthe
button to activate the setting options ("Options").
—> The "IP address of the cassette" – "IP-ADDR" submenu is activated.
IP address of the cassette
IfyouchoosetoentertheEthernetparametersmanually,settheIPaddressof
the cassette in this menu. If "DHCP"isselected,the"IP-ADDR","IP-MASK" and
"IP-GATEWAY" sub-menus display the parameters that were assigned automati-
callybyaconnectedserver.Ifaserverisnotconnected," 0. 0. 0. 0*"
appears in the corresponding menu. The star " * " in the display means that
the data is provided by a DHCP server.
Bx 2
192.168.
IP-ADDR
0.128
- 17 - CCE 210
• Usethe
buttons
to select the digits of the IP address displayed to be
set and use to set the IP address wished.
• Pressthe button.
—> The "Address range (subnet mask)" "IP-MASK" submenu is activated.
Address range (subnet mask)
In this menu you define the address range for the cassettes connected to the
LAN network.
Bx 2
255.255.
IP-MASK
255. 0
• Usethe
buttons to select the digit of the subnet mask displayed to be set
and use
to set the subnet mask wished.
• Pressthe button.
—> The "Address of the gateway" – "IP-GATEWAY" submenu is activated
Address of the gateway
The address of a gateway (server) can be set in this menu. If no gateway is
used you can skip this setting.
Bx 2
192.168.
IP-GATEWAY
0. 1
• Usethe
buttons to select the digit of the IP address displayed to be
set and use to set the IP address wished.
• Pressthe button.
—> The "UDP port" – "UDP-PORT" submenu is activated
.
- 18 - CCE 210
UDP port
TheUDPportsettingisrequiredifthecassetteneedstobereachedexternally
for remote maintenance.
Bx 2
60000
UDP-PORT
• Usethe
buttons to select the digit of the port number displayed to be set
and use
to set the port number wished ("0"…"65535").
• Pressthe button.
—> Return to the main menu "Ethernet parameters"
• Pressthe button.
—> The "Output signal path" – "OUTPUT" main menu is activated.
—> Ifyoudonotwanttodooutputsettings,pressthe button.
The "
Input parameter
" "INPUT" main
menu is activated
(page 23).
Output signal path
In this menu you define the signal path of the output transport streams.
Bx 2
ASI
OUTPUT
=>
Bx 2
IP SPTS
OUTPUT
=>
Bx 2
IP MPTS
OUTPUT
=>
• Usethe buttons to set the signal path wished.
—> Output signal path "IP MPTS"/"IP SPTS" see page 20.
Output signal path "ASI"
In this setting the output transport stream is provided via the ASI output. For this
please also note chapter 6.1 "Combination with other cassettes" (page 32).
Bx 2
ASI
OUTPUT
=>
- 19 - CCE 210
• Pressthe
button.
—> The "ASI transfer rate" – "ASI RATE" submenu is activated.
ASI transfer rate
In this menu you set the transfer rate for the ASI component connected (incl.
stuffing - filled up user data rate).
Forthissettingpleasetaketherequiredinformationfromthedocumentation
(technical data) of the ASI component to be connected.
Bx 2
108000 KBits
ASI RATE
• Usethe
buttons
to select the digits to be set for the transfer rate then
use the buttons to set the transfer rate wished.
• Pressthe button.
—> The "ASI options"
– "ASI OPTION" submenu is activated.
ASI options
Inthismenuyoudefinethesizeofthedatapackets,theirpolarityandthetype
of transmission.
Forthissettingpleasetaketherequiredinformationfromthedocumentation
(technical data) of the ASI component to be connected.
Bx 2
188 pos.
ASI OPTION
cont.
• Pressthe buttons to set the size of the data packets ("188" or "204"
bits).
• Ifthepolarityofthedatatobetransmittedhastobechanged,pressthe
to select
"pos." (positive – standard) and using the buttons set
to "neg." (negative).
• Tochangethetypeoftransmissionpressthe
buttons to select
"cont."
- 20 - CCE 210
(continuous – standard) and using the buttons set to "burst".
—> Setting "cont."
The data packets of the user data are collected to a great data
packet in the transport stream.
—> Setting "burst"
The data packets of the user data are spaced out evenly in the trans-
port stream.
• Pressthe button.
—> Return to the main menu "Output signal path"
Output signal path "IP MPTS"/"IP SPTS"
In this setting the output transport stream is provided via the Ethernet socket.
If "
IP MPTS" (Internet Protocol Multi Programme Transport Stream)isselected,
allservices(programmes)fedinviatheAV1,AV2andASIinputsareprovided
in one multi programme transport stream with one IP address.
If "
IP SPTS" (Internet Protocol Single Programme Transport Stream)isselected,
the signal from input
- AV1 is provided in one single programme transport stream with one output
IP address (IP 1).
- AV2 is provided in one single programme transport stream with one output
IP address (IP 2).
• Pressthe buttons to select the signal path wished.
Bx 2
IP SPTS
OUTPUT
=>
Bx 2
IP MPTS
OUTPUT
=>
• Pressthe button.
—>
The"Transmissionprotocol, Port number" – "MODE / PORT" sub-
menu is activated.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

Triax CCE 210 Assembly Instructions Manual

Type
Assembly Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI