GSS PTIS 1000 Assembly Instructions Manual

Category
Musical Equipment
Type
Assembly Instructions Manual
English
PTIS 1000
Head-End DVB-T Converter to IP
DVB-T to SPTS
CLASS
KLASSE
GSS
Grundig SAT Systems GmbH
Beuthener Strasse 43
D-90471 Nuremberg
Phone: +49 (0) 911 / 703 8877
Fax: +49 (0) 911 / 703 9210
Internet: http://www.gss.de
- 2 - PTIS 1000
Contents
1 Safety regulations and notes .....................................................................................4
2 General information .................................................................................................5
2.1 Packing contents ..........................................................................................5
2.2 Meaning of the symbols used ........................................................................5
2.3 Technical specifications ................................................................................5
2.4 Description .................................................................................................7
2.5 Software query ............................................................................................8
3 Assembly .................................................................................................................9
3.1 Installing the cassette ....................................................................................9
3.2 EMC regulations ..........................................................................................9
3.3 Overview of the cassette ............................................................................10
3.4 Connecting the cassette ..............................................................................11
3.5 Updating the software ................................................................................11
3.6 Retrofitting a CA module ............................................................................12
4 The control panel at a glance ..................................................................................13
4.1 Menu items ...............................................................................................13
4.2 Control panel ............................................................................................13
5 Programming .........................................................................................................14
5.1
Programming procedure ................................................................................. 14
Channel strips "Tuner A" (without CA module) and "Tuner B" ..........................14
Channel strip "Tuner A" with CA module ......................................................16
5.2 Programming the cassette ..........................................................................17
Selecting the cassette, displaying the software version ....................................17
Setting the Ethernet parameters ...................................................................18
Setting the IP address of the cassette ............................................................18
Setting the address range ...........................................................................19
Setting the address of the gateway ..............................................................19
Setting the UDP port .................................................................................... 19
Selecting the input transport stream ..............................................................20
Setting the input channel ............................................................................21
Setting the hierarchical modulation ..............................................................22
Allocating the IP addresses .........................................................................23
Switching the IP address off or on ................................................................23
Selecting the transmission protocol ...............................................................23
Setting the port number ..............................................................................23
Copying the settings to all IP addresses ........................................................24
Defining the quantity of data packets ...........................................................25
Setting the forward error correction .............................................................25
Setting the transmission channel ..................................................................25
Copying the settings to all IP addresses ........................................................25
Setting IP addresses for services ..................................................................26
Allocating IP addresses to services manually .................................................26
Allocating IP addresses to services automatically ...........................................26
- 3 - PTIS 1000
Allocating services manually .......................................................................27
Selecting the sound options of the service .....................................................28
Switching DVB service information on or off ..................................................28
Displaying the output data rate ....................................................................29
Factory reset .............................................................................................29
Saving settings ..........................................................................................30
5.2.1 Operation with a CA module ............................................................31
Setting the PID monitoring ................................................................31
Configuring the CA module ..............................................................31
Descrambling services .....................................................................33
6 Final procedures .....................................................................................................34
- 4 - PTIS 1000
1 Safety regulations and notes
• Assembly,installationand servicingshouldbe carried outbyauthorised
electricians.
• Switchofftheoperatingvoltageofthesystembeforebeginningwithassem-
bly or service work or pull out the mains plug.
• Donotperforminstallationandserviceworkduringthunderstorms.
• Installthesystemsoitwillnotbeabletovibrate…
- inadust-free,dryenvironment
- insuchamannerthatitisprotectedfrommoisture,fumes,splashingwa-
ter and dampness
- somewhere protected from direct sunlight
- not within the immediate vicinity of heat sources
- in an ambient temperature of 0 °C to +50 °C. In case of the formation of
condensation wait until the system is completely dried.
• Ensurethatthehead-endstationisadequatelyventilated.Donotcoverthe
ventilation slots.
• Bewareofshortcircuits
• Noliabilityisacceptedforanydamagecausedbyfaultyconnectionsor
inappropriate handling.
• Observetherelevantstandards,regulationsandguidelinesontheinstalla-
tion and operation of antenna systems.
• The standards IEC/EN/DINEN50083 and IEC/EN/DINEN60728 must
be observed.
For further information please read the assembly instructions for the head-
end station used.
• Test the software versions of the head-end station and the cassette and
update them if necessary. The current software versions can be found at
"www.gss.de".
Take action to prevent static discharge when working on the device!
Electronic devices should never be disposed of in the household rubbish. In
accordance with directive 2002/96/EC of the European Parliament and the
European Council from January 27, 2003 which addresses old electronic and
electrical devices, such devices must be disposed of at a designated collection
facility. At the end of its service life, please take your device to one of these
public collection facilities for proper disposal.
- 5 - PTIS 1000
2 General information
2.1 Packing contents
1 Cassette PTIS 1000
2 HF cables
1 CD (assembly instructions)
1 Brief assembly instructions
1 Measuring log
2.2 Meaning of the symbols used
Important note
—> General note
•  Performingworks
2.3 Technical specifications
The devices meet the following EU directives:
2006/95/EC,2004/108/EC
The product fulfils the guidelines and standards for CE labelling.
Unless otherwise noted all values are specified as "typical".
HF input
Channels: .........................................................C05…C12,C21…C69
Frequencyrange: ................................... 177.5…226.5,474…858MHz
Input level: ...............................................................60dBμV…80dBμV
Loop through output gain ......................................................0dB…3dB
Return loss: ..................................................................................> 8 dB
Impedance: .................................................................................... 75
Symbol rate ...............................................................acc. to EN 300744
LAN interface
Standard: .............................................................................100-BASE-T
Data rate: ............................................................................... 80 MBit
Protocols: .......................................................... UDP(UserDataProtocol),
RTP (Real-Time Transport Protocol)
- 6 - PTIS 1000
ASI interfaces
Standard: .....................................................................DIN EN 50083-9
Format: ................................................................MPEG ISO IEC 13818-1
User data rate: ................................................................. 2…90Mbit/s
Impedance: .................................................................................... 75
Level (input / output): ..................................................... 800mV
pp
± 10%
Return loss (input): ............................................... >17dB(5…270MHz)
Connections
HF inputs: ...........................................................................2 IEC sockets
HF loop-through outputs: .......................................................2 IEC sockets
HF output: ..........................................................1 IEC socket (no function)
LAN: ................................................................................1 RJ 45 socket
ASI input: ..........................................................................1 BNC socket
ASI output: .........................................................................1 BNC socket
Connection strip (10-pin): ...................for supply voltages and control circuits
RS 232 socket: ..................................... serial interface for software update
Common Interface: ....................... 1 (several services can be descrambled).
- 7 - PTIS 1000
2.4 Description
The cassette is a
DVB-T/SPTS
converter which combines COFDM-modulated
services (programmes) and transport streams supplied via the ASI interface
into one transport stream in the TPS module. This is emitted via the LAN inter-
faceandcancontainupto16services.ForoperatingthecassetteinaLAN
networkitcanbeassigneditsownIPaddress.Thecassetteisequippedwith
two tuners. The accompanying channel strips consist of the digital tuners and
the digital signal processing levels. The resulting transport streams from the
"
Tuner A
"/"
Tuner B
" channel strips and from the transport streams supplied
via the ASI socket (ASI – Asynchronous Serial Interface according to DIN EN
50083-9)cantakeupto16servicesandareeachassignedanIPaddress.
The signal supplied into the ASI input is provided again via the ASI output.
Principle signal path:
TPS
"Tuner A"
"Tuner B"
CA-ModulCA module
ASI input
ASI output
IP address: Port:
Service 1 212.40.50.90 : 1234
Service 2 212.40.50.91 : 1234
Service 3 212.40.50.92 : 1234
Service 4 212.40.50.93 : 1234
Service 5 212.40.50.94 : 1234
Service 6 212.40.50.95 : 1234
Service 7 212.40.50.96 : 1234
Service 8 212.40.50.97 : 1234
Service 9 212.40.50.98 : 1234
Service 16 212.40.50.105 : 1234
Inthehead-endstationdisplay,thechannelstripsofthecassetteareindicated
with "
Bx …A
" ("
Tuner A
") or "
Bx …B
" ("
Tuner B
"). The channel strip "
Tuner A
"
can decode encoded services via a corresponding CA module and a dedicat-
ed smart card. The cassette is programmed using the head-end station control
unit.
Two LEDs in the channel strips provide an indication with their colour whether
anHFsignalispresentornot.Inamenu,thetransmissionofDVBservicein-
formation(EIT,TDTandSDT)orteletext(TXT)canbeindividuallyactivatedor
deactivated.
EIT (Event Information Table):
Foreachservice,eventinformationistransmitted(suchasstartingtime,dura-
tion,scramblingetc.)
- 8 - PTIS 1000
TDT (Time Date Table):
The transmitted table contains the current time and date.
SDT (Service Description Table):
Information relating to the
scrambling
is also sent with the name of each serv-
ice.
The LEDs for the LAN interface show whether a network connection exists and
whether a data transfer is in progress.
When the head-end station is switched on, the two-line LC display shows the
software version of the control unit.
To operate this cassette the software version of the control unit must be "V 41"
or higher. You can find the current operating software for the control unit and
the cassette, the software "BE-Flash" and the current assembly instructions on
the website "www.gss.de".
The cassette is designed for use in the following head-end stations:
PSU12,PSU8,PGT8 and PST 19-1.
2.5 Software query
Control unit
If necessary, you can activate the indication of the software version of the
control unit manually:
• Pressanytwokeysonthecontrolunitofthehead-endstationsimultaneously
until the display goes dark and the software version, e.g. "V 41" appears.
Cassette
After activating the cassette the software version of the cassette is displayed
(see page 17).
- 9 - PTIS 1000
3 Assembly
3.1 Installing the cassette
– Ensure the head-end station is mounted so it will not be able to vibrate.
Avoid,forexample,mountingthehead-endstationontoaliftshaftorany
other wall or floor construction that vibrates in a similar way.
Before installing or changing a cassette unplug the power cable from the
mains power socket.
• Removethefasteningscrews1 of an unoccupied slot from the bracket of
the head-end station.
• Insertthecassetteinthisslotandpushitintothehousing.
• Alignthecassetteandapplyslightpressuretoconnectittotheconnections
of the board and the HF bus bar.
• Fastenthecassettewiththescrews1.
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
AUSGANG
max. 90 dBµV
ACHTUNG!
Vor dem Kassettenwechsel
unbedingt
denNetzstecker ziehen.
CAUTION!
Before
changing cassettes remove
mains plug.
GrundigSATSystems
1
1
3.2 EMC regulations
To comply with the current EMC regulations, it is necessary to connect the lines
leading in and out of the head-end station using cable terminals.
When mounting the cassette in a head-end station which is installed in a 19"
cabinet, make sure the connections leading in and out for the 19" cabinet are
made using cable terminals.
CLASS
KLASSE
The attenuation of shielding of the connection lines for ASI and antenna must
meet the requirements for "Class A".
- 10 - PTIS 1000
• Inserttherequirednumberofcableterminalsintheopeningsprovidedin
the head-end station or in the 19
"
cabinet.
—> Cable terminals are not included in the scope of delivery.
Tighten the nuts of the cable terminals until the teeth on the lock washers
put un-
der
have penetrated the exterior coating and a good connection is made between
the housing
/ 19" cabinet
and cable terminals.
3.3 Overview of the cassette
7 8 9 0 ! # $32 65 @ %41
1 HF input
(channel strip "
B
")
2 Status LED
of the channel strip "
B
"
3
Loop-through output of
HF
input
1
4
HF input
(channel strip "
A
")
5 Status LED
of the channel strip "
A
"
6
Loop-through output of
HF
input
4
7 Status LED of the LAN interface (yellow LED – data transfer)
8
LAN socket
9 Status LED of the LAN interface (green LED – network connection)
0 ASI input
! ASI output
@ Type label
# Slot for a CA module
$ D-SUB socket "RS 232"
% MAC address
- 11 - PTIS 1000
3.4 Connecting the cassette
• Connectthe HF connectionstotheinputs
4
(channel strip "
A
") and
1
(channel strip "
B
").
• ConnecttheLANsocket
8
.
• ConnecttheASIinput
0
and the ASI output
!
to the peripheral ASI devices.
3.5 Updating the software
The RS 232 interface of the cassette $ enables you to use a PC or a notebook
and the "BE-Flash" software to update the software of the cassette.
You can find the "BE-Flash" software and the current operating software of the
cassette at the website "www.gss.de".
•Usea"one-to-onecable"toconnectthecassettesRS232interfaceandthe
PC according to the wiring scheme below.
9-pin
D-SUB socket
9-pin
D-SUB plug
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
—> If necessary use a standard RS-232/USB adapter.
• Startthe"BE-Flash" software and update the software of the cassette.
- 12 - PTIS 1000
3.6 Retrofitting a CA module
Thecassetteisequippedwithacommoninterface.Itallowsyoutoconnecta
CA module for various scrambling systems and service providers. Scrambled
services can only be descrambled with a CA module suitable for the scram-
bling system and the corresponding smart card. The smart card contains all the
informationforauthorisation,descramblingandsubscription.
Check with the distributor or manufacturer of the CA module to be used
to ensure that it is suitable for descrambling several
services
.
The hardware and software of this cassette have been thoroughly prepared
and tested.
Any changes made by
service
providers in the data structures might impair
or even prevent this function.
– WhenworkingwiththeCAmodule,pleasereadthecorrespondingoperat-
ing manual from the respective provider.
• Insertthesmartcard
1
into the CA module
2
so that the chip
3
on the
smart card faces the thicker side (top) of the CA module.
• InserttheCAmoduleintotheguiderailsoftheCAslot
4 with the top side
of the CA module facing the top side of the cassette.
• PushtheCAmodulewithoutcantingintotheguiderailsoftheCAslot
4
and contact it to the common interface.
3
4
1
2
- 13 - PTIS 1000
4 The control panel at a glance
4.1 Menu items
Programme the
cassette
using the buttons on the control unit of the head-end
station. The two-line display of the control unit then shows the menus.
The parameters and functions to be set are underlined.
Use the key to select the following main menu items:
Setting Ethernet parameters
Selecting the input
Allocating the IP addresses
Displaying the data rate
Factory reset
4.2 Control panel
The key pad on the head-end station is used to scroll through the menus:
scrolls forward through the menus.
select parameters in the menus.
setvalues,initiateactions.
selects sub-menus.
scrolls backward through the menus.
saves all entries.
BE-Remote V41
PROFESSIONAL
- 14 - PTIS 1000
5 Programming
5.1
Programming procedure
Channel strips "Tuner A" (without CA module) and "Tuner B"
BERemote
please wait
V 41
Box 4
V 12
DVBT-SPTS
Box 1
……
……
……
Bx 1A
C5-12,S3-24
TWIN-SAT
C07
x 4
C5-12,S3-24
TWIN-SAT
C07
Box 5
……
……
……
+
t > 10 s
Bx 4
stat =>
ETHERNET
Options
stat / DHCP
A
Bx 4
192.168. 0. 1
IP-GATEWAY
Bx 4
255.255.255. 0
IP-MASK
/
Bx 4
192.168. 0.128
IP-ADDR
/
/
Bx 4
60000
UDP-PORT
/
B
0 … 65535
Ein / On
Tuner A /
Tuner B /
ASI
Bx 4A
C30 (546.0)
INPUT
OK
/
Bx 4
Tuner A OK
INPUT
=>
C
D
Kanalzug “Tuner A” mit CA-Modul
Channel strip “Tuner A“ with
CA module
Kanalzug “Tuner A” ohne CA-Modul,
Kanalzug “Tuner B” /
Channel strip “Tuner A“ without CA
module, Channel strip “Tuner B“
Frequenz / Feinabstimmung
Frequency / Fine tuning
C5…C12, C21…C69
-64…+64
IP-OUT 1
IP-OUT 16
Bx 4
72.956 Mbps
DATARATE
IP 1
227. 40. 50. 60
OUT-IP
IP 1
7 off
PKTS / FEC
/
IP 1
on UDP
MODE / PORT
1234
/
Bx 4
Das Erste
IP-OUT 1
=>
on / off
UDP / RTP,
0 … 65535
copy
off / 10/9 … 20/19
Annex A / Annex B
001/016IP 1 TV
Das Erste
Bx 4
EIT TDT TXT SDT
OPTIONS
/
EIT / eit, TDT / tdt,
TXT / txt, SDT / sdt
(ON / off)
all / 01/…
IP 1
all
AUDIO
copy1 … 7
copy
/
auto
Tuner A
Tuner B
Bx 4A
Priority: high
INPUT
high / low
auto
M
B
A
Bx 4A
Defaults
FACTORY
=>
Bx 4A
STORE
FACTORY
=> M
Werkeinstellwerte
aufrufen
invoke factory defaults
page 15
page16
- 15 - PTIS 1000
BERemote
please wait
V 41
Box 4
V 12
DVBT-SPTS
Box 1
……
……
……
Bx 1A
C5-12,S3-24
TWIN-SAT
C07
x 4
C5-12,S3-24
TWIN-SAT
C07
Box 5
……
……
……
+
t > 10 s
Bx 4
stat =>
ETHERNET
Options
stat / DHCP
A
Bx 4
192.168. 0. 1
IP-GATEWAY
Bx 4
255.255.255. 0
IP-MASK
/
Bx 4
192.168. 0.128
IP-ADDR
/
/
Bx 4
60000
UDP-PORT
/
B
0 … 65535
Ein / On
Tuner A /
Tuner B /
ASI
Bx 4A
C30 (546.0)
INPUT
OK
/
Bx 4
Tuner A OK
INPUT
=>
C
D
Kanalzug “Tuner A” mit CA-Modul
Channel strip “Tuner A“ with
CA module
Kanalzug “Tuner A” ohne CA-Modul,
Kanalzug “Tuner B” /
Channel strip “Tuner A“ without CA
module, Channel strip “Tuner B“
Frequenz / Feinabstimmung
Frequency / Fine tuning
C5…C12, C21…C69
-64…+64
IP-OUT 1
IP-OUT 16
Bx 4
72.956 Mbps
DATARATE
IP 1
227. 40. 50. 60
OUT-IP
IP 1
7 off
PKTS / FEC
/
IP 1
on UDP
MODE / PORT
1234
/
Bx 4
Das Erste
IP-OUT 1
=>
on / off
UDP / RTP,
0 … 65535
copy
off / 10/9 … 20/19
Annex A / Annex B
001/016
IP 1 TV
Das Erste
Bx 4
EIT TDT TXT SDT
OPTIONS
/
EIT / eit, TDT / tdt,
TXT / txt, SDT / sdt
(ON / off)
all / 01/…
IP 1
all
AUDIO
copy1 … 7
copy
/
auto
Tuner A
Tuner B
Bx 4A
Priority: high
INPUT
high / low
auto
M
B
A
Bx 4A
Defaults
FACTORY
=>
Bx 4A
STORE
FACTORY
=> M
Werkeinstellwerte
aufrufen
invoke factory defaults
page16
page 14
- 16 - PTIS 1000
Channel strip "Tuner A" with CA module
Bx 4A
Menu <=
CA
=> Edit
*) Die angezeigte Information ist
abhängig vom verwendeten
CA-Modul.
The information displayed is
dependent on the CA module
used.
Bx 4A 01/03
Information *)
MENU
Bx 4A TV X
. . . .
04/09
X entschlüsseln
descrambling
0 nicht entschlüsseln
no descrambling
X / 0
nächster Service
next service
Bx 4A
PID Check
CA
on
on / off
M
/
D
C
page 14
page 15
- 17 - PTIS 1000
5.2 Programming the cassette
> Pressing the button for longer than 2 seconds cancels the pro-
gramming procedure. This takes you back to the program item "Selecting
the cassette" from any menu. Any entries that have not been saved are
reset to the previous settings.
> Entries in the menus can be saved by pressing the key. You are taken
back to the "Selecting the cassette" menu item.
>
Using the
button previous menus can be activated.
• Switchonthehead-endstation
> The display shows the software version (e.g. V 41)
> The processor reads the
cassettes
‘ data (approx. 10 seconds).
Ein / On
BE–Remote
please wait
V 41
t > 10 s
Selecting the cassette, displaying the software version
Box 4
V 12
DVBT-SPTS
Box 1
……
……
……
Bx 1A
C5-12,S3-24
TWIN-SAT
C07
x 4
C5-12,S3-24
TWIN-SAT
C07
Box 5
……
……
……
+
• Selectthe
cassette
you want to program (e.g. Box 4) by repeatedly pressing
the button if necessary.
> The display shows e.g. the menu
"Box 4 DVBT-SPTS"
:
"Box 4" stands for
slot
4
"
DVBT-SPTS
" type of cassette
"V 12" software version of the cassette
• Pressthe button.
> The "Setting the Ethernet parameters" – "ETHERNET" menu is activated.
- 18 - PTIS 1000
Setting the Ethernet parameters
In this menu you specify whether the Ethernet parameters for the cassette are
entered automatically by a connected server ("DHCP"), or whether you want
to enter them manually ("stat"). To assign the cassette uniquely, each IPTV cas-
sette must be allocated its own IP address.
Bx 4
stat =>
ETHERNET
Options
• Pressthe buttons to select manual setting ("stat") or automatic setting
("DHCP") of the Ethernet parameters.
• Pressthe
button to activate the setting options
("Options")
.
> The "Setting the IP address of the cassette"
menu "IP-ADDR" is activated.
Setting the IP address of the cassette
If you choose to enter the Ethernet parameters manually, set the IP address of
the cassette in this menu. If "DHCP" is selected, the "IP-ADDR", "IP-MASK" and
"IP-GATEWAY" sub-menus display the parameters that were assigned automati-
cally by a connected server. If a server is not connected, " 0. 0. 0. 0*"
appears in the corresponding menu. The star " * " in the display means that
the data is provided by a DHCP server.
Bx 4
192.168. 0.128
IP-ADDR
• Usethe
buttons to place the cursor under the digit of the IP address
displayed to be set and use to set the IP address wished.
• Pressthe
button.
> The "Setting the address range"
– "IP-MASK" menu is activated.
- 19 - PTIS 1000
Setting the address range
In this menu you define the address range for the cassettes connected to the
LAN network.
Bx 4
255.255.255. 0
IP-MASK
• Usethe
buttons to place the cursor under the digit of the IP address
displayed to be set and use to set the IP address wished.
• Pressthe
button.
> The "Setting the address of the gateway"
"IP-GATEWAY" menu is acti-
vated.
Setting the address of the gateway
The IP address of a gateway (server) can be set in this menu. If no gateway is
used you can skip this setting.
Bx 4
192.168. 0. 1
IP-GATEWAY
• Usethe
buttons to place the cursor under the digit of the IP address
displayed to be set and use to set the IP address wished.
• Pressthe
button.
> The "Setting the UDP port"
– "UDP-PORT" menu is activated.
Setting the UDP port
The UDP port setting is required if the cassette needs to be reached externally
to make the setting, such as from another input frequency. This setting is in-
tended for future functions and can be skipped for this cassette.
Bx 4
60000
UDP-PORT
- 20 - PTIS 1000
• Usethe
buttons to place the cursor under the digit of the port number
displayed to be set and use to set the port number wished ("0"
"65535").
• Pressthe
button.
> The "Selecting the input transport stream"
– "
INPUT
" menu is activated.
Selecting the input transport stream
In this menu you select the signal source for the selection of the services. The
transport streams to be processed are provided by "Tuner A","Tuner B" and
the ASI interface "ASI".
Bx 4A
Lan
INPUT
• Pressthe buttons to select the signal source of the input transport
stream ("Tuner A","Tuner B","ASI").
—> "OK" indicates that an input signal is present. If there is no input signal
available "
– –
" is displayed instead of "OK".
Input transport stream selected: "ASI"
• Pressthe button.
—>
The menu "Allocating IP addresses" – "
IP-OUT 1" is activated (page 23).
Input transport stream selected: "Tuner A" or "Tuner B"
• Pressthe button.
—>
The menu "Setting the input channel" – "
INPUT" is activated.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

GSS PTIS 1000 Assembly Instructions Manual

Category
Musical Equipment
Type
Assembly Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI