Samsung SOC-B120P User manual

Category
Security cameras
Type
User manual

This manual is also suitable for

E
R
User's guide
êÛÍÓ‚Ó‰ÒÚ‚Ó ÔÓθÁÓ‚‡ÚÂÎfl
Observation Camera
SOC-C120P
SOC-B120P
AB68-00471A
3
E
2
E
Important Safety Instructions
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE REAR COVER. NO
USER SERVICEABLE PARTS INSIDE. REFER TO
QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC
SHOCK DO NOT OPEN
This symbol indicates high voltage is
present inside. It is dangerous to
make any kind of contact with any
inside part of this product.
This symbol alerts you that important
literature concerning operation and
maintenance has been included with
this product.
5. If any unusual smells or smoke come from the unit,
stop using the product. In such case, immediately
disconnect the power source and contact the service
center. (Continued use in such a condition may cause
fire or electric shock.)
6. If this product fails to operate normally, contact the
store of purchase or your nearest service center.
Never disassemble or modify this product in any way.
(The manufacturer is not liable for any damage
resulting from unauthorized disassembly or repairs.)
7. When cleaning, do not spray water directly onto parts
of the product. (Doing so may cause fire or electric
shock.) Wipe the surface with a dry cloth. Never use
detergents or chemical cleaners on the product, as
this may result in discoloration of surface or cause
damage to the finish.
1. Do not drop objects on the product or apply strong
shock to it. Keep away from a location subject to
excessive vibration or magnetic interference.
2.. Do not install in a location subject to high temperature
(over 50°C/122°F), low temperature (below -10°C
/14°F), or high humidity. (Doing so may cause fire or
electric shock).
3. Avoid a location which is exposed to direct sunlight,
or near heat sources such as heaters or radiators.
(Neglecting to do so may result in a risk of fire).
4. If you want to relocate the already installed product, be
sure to turn off the power and then move or reinstall it.
5. Install in a well - ventilated location.
6. Remove the power plug from the outlet when there is
a lightning storm. (Neglecting to do so may cause fire
or damage to the product.)
1. Make sure that the cable is plugged in securely
before using. (A loose connection may result in fire.)
2. When installing the camera on a wall or ceiling,
mount it safely and securely. (A falling camera may
cause personal injury.)
3. Do not place conductive objects (e.g., screwdrivers,
coins, and metal things) or containers filled with
water on top of the camera. (Serious injury may
result from fire, electric shock, or falling objects.)
4. Do not install in a sooty, dusty, or humid location.
(Doing so may cause fire or electric shock.)
4 5
EE
Overview
Observation Camera is the monitoring camera
incorporated with the recent CCD that provides
the best monitoring function in connection with the
CCTV system equipment.
Number of CCD pixels
320,000 pixels
Power supply
SOC-C120P : DC12V From Monitor(SMO-150QP)
SOC-B120P
: DC12V From Monitor(SMO-120MP)
Automatic function and special function
ATW
ELC(Electronic shutter iris)
Alarm Sensor input
Audio input
The SOC-C120P is SMO-150QP(Monitor) only
The SOC-B120P is SMO-120MP(Monitor) only
Part Names and Function
!@#$%^
PIN NUMBER SPEC
1 SPEAKER(HOT)
2 VIDEO_OUT
3GND
4 SPEAKER(COLD)
5
AUDIO_OUT/ALARM_OUT
6 12V DC
a
Lens
It has a focal length of 3.8mm and makes it possible
for you to observe a relatively wide area.
b
Microphone
Capable of picking up all sound in the vicinity of the
camera location and transmitting to the monitor.
6 7
EE
c
Camera fitting groove
Enables the camera to be fixed onto the bracket.
You may install it either above or below the camera if
necessary.
d
6-pin modular jack
Used to connect the camera to the monitor.
e
SENSOR jack
Used to connect the sensor to the camera.
f
Speaker
It outputs the sound signal which was transfered from
the monitor.
Installation
Check what is inside the package
Check to see if the following parts are included in
the purchased package.
Camera Camera Mount Bracket
User’s Guide Alarm Terminal-Block Camera Cable
(Camera Kit option)
8 9
EE
Notes on installation and usage
1.Users should not disassemble the camera from
the front direction.
2.Always handle the camera with care.
Please do not apply a shock or vibration as
much as possible and take cautions not to cause
damage or make a scratch on the camera due to
careless storage.
3.Please do not install the camera with the rainy
place or highly humid areas. And do not operate
the camera in the wet place.
4.Do not clean the camera body with the strong
abrasives or soaps. When the camera becomes
dirty, clean it with the dry rugs. Especially, make
sure to use the dedicated rugs for lens to clean
the dome cover.
5.Please select the camera in the cool area that is
not exposed to the direct sunlight. If you do, it
can cause bad effects on the product.
Cable connection
Caution to install SOC-B120P/SOC-C120P out-
doors
SOC-B120P/SOC-C120P is designed to be protected
from the water drops which are falling on the
upper side of camera in a range of 15
°
.
(Dust-water protection level : IP42)
Therefore, be sure to install it in a location
which is fit in above condition when you install it
outdoor.
SOC-B120P/SOC-C120P
camera can be
attached to the wall,ceiling or shelf using the
camera mount bracket (SBR-110).
Choose an installation site that can sufficiently
support the weight of the equipments to be
installed.
Attach the camera mount bracket to the wall or
ceiling using the supplied three screws (M4 X L15).
Adjust the camera to target the video location
and tighten the bracket handle on the camera
mount bracket.
10 11
EE
4x15 sized screws
wall or ceiling
Connect the camera cable to the camera cable
jack on the camera,then connect,and the other
end of the cable to the monitor's channel input jack.
< SOC-B120P >
< SOC-C120P >
12 13
EE
An additional PIR sensor or external sensor can
also be connected.
The additional PIR sensor can be connected as
shown in the above graphic.
Sensor's trigger signal is NO (Normal Open).
Sensor is not supplied. (Sold separately)
External terminal connecting method for camera
Camera alarm in jack
Sensor
in put
Specifications
SOC-C120P / SOC-B120P : Standard Camera
Model Name
SOC-C120P/ SOC-B120P
Broadcast System
SOC-C120P: PAL STANDARD
SOC-B120P: CCIR STANDARD
Imaging Device
SOC-C120P:
1/4 SUPER HAD IT CCD
SOC-B120P: 1/3” B/W IT CCD
Effective Pixels
500(H) x 582(V)
Synchronization
Internal
Resolution
SOC-C120P:
H :330 TV Lines,
V :350 TV Lines
SOC-B120P: H:380 TV Lines,
V:350 TV Lines
Signal Output
VBS 1.0 Vp-p(75ohm composite)
S/N Ratio
SOC-C120P: 48 dB
SOC-B120P: 50 dB
Minimum Object
SOC-C120P: 2lux(F2.0, 50 IRE)
Illumination
SOC-B120P: 0.2lux(F2.0, 50 IRE)
Gamma Correction
0.45
Lens
Focal Length (f) : 3.8mm,
Relative Aperture (F) : 2.0
Auto Exposure
Electronic Shutter lris
Audio
-40dB Condenser
Microphone Inclusion
I/O Connectors
Modular jack
Operating Temperature -10 ~ + 50
°C
Power Source
DC 12V (From Monitor)
Power Consumption Approx. 2W
Dimensions
57(W)X47.2(H)X100.5(L)
Weight
130g
14
E
R
êÛÍÓ‚Ó‰ÒÚ‚Ó ÔÓθÁÓ‚‡ÚÂÎfl
SOC-C120P
SOC-B120P
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Samsung SOC-B120P User manual

Category
Security cameras
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI