The OFSM-RCN Kit contains the following:
• 1 Remote Receiver 111441-02
• 1 Remote Control 111442-01
• 1 Conversion Instructions 114370-05
• 4 Batteries AA 1.5v 111836-02
• 2 Cable Ties 11407
• 1 Bracket 117074-02
• 1 Step Motor 117075-01
• 2 Screws 8-32 x 3/8" 111782-01
For more information, visit www.desatech.com
WARNING: This conversion kit shall be installed
by a qualied service agency in accordance with the
manufacturer's instructions and all applicable codes and
requirements of the authority having jurisdiction. The
information on this instruction must be followed to mini-
mize the risk of re or explosion or to prevent property
damage, personal injury or death. The qualied service
agency performing this work assumes responsibility for
the proper conversion of this appliance with this kit.
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
WARNING: Improper installation, adjustment, al-
teration, service or maintenance can cause injury or
property damage. Refer to this manual for correct in-
stallation and operational procedures. For assistance
or additional information consult a qualied installer,
service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
APPROVED
TESTED AND
LISTED BY
OFSM-RCN AND OFSM-RCP ON-OFF/HI-LO
REMOTE CONVERSION KIT
For All Millivolt Cascade Natural and Propane/LP Gas Logs
(NOT A GAS CONVERSION KIT)
ANSI Z21.60
CSA 2.26
The OFSM-RCP Kit contains the following:
• 1 Receiver 111441-02
• 1 Remote Control 111442-01
• 1 Conversion Instructions 114370-05
• 4 Batteries AA 1.5v 111836-02
• 2 Cable Ties 11407
• 1 Bracket 117074-02
• 1 Step Motor 117075-02
• 2 Screws 8-32 x 3/8" 111782-01
IHP.us.com 126916-01A
2
www.desatech.com 114370-05C2
CHECK GAS TYPE
The Hi/Lo conversion kit comes in natural gas
(OFSM-RCN) or propane/LP (OFSM-RCP). If
you are unsure of the proper application, call
dealer where you bought your appliance.
INSTALLATION ITEMS NEEDED
Before installing the kit, make sure you have
the items listed below.
• torx wrench T20 or slotted screwdriver
• Phillips screwdriver
Figure 1 - Technical Information Charts
OFSM-RCN ANd OFSM-RCP
(ON/OFF ANd HI/LO)
Remote Conversion Kit or Replacement
Instructions
1. Turn control knob to the OFF position, and
shut off gas supply to valve.
2. Remove 4 screws and face plate. See
Figure 2.
3. Remove On/Off knob.
Figure 3 - Removing Mounting Screws,
Pressure Regulator Tower, and
Diaphragm/Spring Components
O
F
F
P
I
L
O
T
O
N
Mounting
Screws
Pressure
Regulator
Tower
Diaphragm/
Spring
Components
Screws Valve
ON/OFF Knob
Faceplate
Figure 2 - Changing Burner Orice and
Air Shutter
Pilot
Adjustment
Screw
MODEL
BTU/HR
INPUT
NATURAL
GAS
BTU/HR
INPUT
PROPANE/
LP
VTD-18NV-JHB
VTD-18PV-JHB
59,000
59,000
41,000
46,000
VTD-24NV-JHB
VTD-24PV-JHB
69,000
69,000
49,000
50,000
VTD-30NV-JHB
VTD-30PV-JHB
74,000
74,000
54,000
55,000
FUEL PRESSURE
SPECIFICATION (W.C.)
INLET MANIFOLd
NG 5.0"-10.5" 3.5"
LP 11"-14" 10"
BURNER ORIFICE
LOG SIZE IN NUM.
VTD-18NV-JHB
VTD-18PV-JHB
0.1495
0.0935
25
42
VTD-24NV-JHB
VTD-24PV-JHB
0.1570
0.0980
22
40
VTD-30NV-JHB
VTD-30PV-JHB
0.1660
0.1015
19
38
4. Using Torx T20, or slotted screwdriver,
remove and discard three pressure regu-
lator mounting screws, pressure regulator
tower, and spring and diaphragm assem-
bly (see Figure 3).
5. Insure that rubber gasket is properly posi-
tioned and install new step motor pressure
regulator assembly to valve using new
screws supplied with kit. Tighten screws
securely (see Figure 4, page 3) (reference
torque=25 in-lbs).
IHP.us.com
126916-01A 3
www.desatech.com 3114370-05C
To
Thermopile
Figure 4 - Installing Step Motor Pressure
Regulator Assembly
O
F
F
P
I
L
O
T
O
N
Mounting
Screws
Rubber
Gasket
Identication
Label
Pilot
Adjustment
Screw
Location
Step Motor Pressure
Regulator Assembly
6. Install enclosed identification label to
valve body where it can easily be seen.
7. Connect step motor cable (supplied) to
receiver (see Figure 4 and Figure 6).
8. Connect "+" (positive) terminal of thermo-
pile to TP terminal of gas valve. Connect
"-" (negative) terminal of thermopile to
TPTH terminal of gas valve (see Figure 5).
Set BACKUP switch to the AUTO position
(see Figure 6).
9. Connect supplied receiver cable to re-
ceiver gas valve connector (see Figure 8
and Wiring Diagram, page 5). The red wire
must be connected to TH terminal of gas
valve and black wire must be connected
to the TPTH terminal of the gas valve (see
Figure 7 and Wiring Diagram, page 5).
10. Reinstall face plate and screws (see
Figure 4, page 3).
11. Install supplied 4 AA batteries 1.5v to
receiver (see Figure 7).
12. Install receiver using supplied bracket and
zip ties (see Figure 8).
Figure 5 - Connecting Wire Terminals
Control
Valve Black
Red
MOTOR AUTO MAN
Figure 6 - Knob and Switch Locations
Figure 7 - Battery Installation in Receiver
Receiver Gas
Valve Connector
Backup Switch
in Auto Position
Figure 8 - Installing Bracket and Receiver
Zip Ties
Receiver
Bracket
Receiver
Step
Motor
Cable
Connector
Step Motor
Cable
IHP.us.com 126916-01A
4
www.desatech.com 114370-05C4
Figure 9 - Address Location on Receiver
Figure 10 - Address Location on Remote
Dip Switches
Dip Switches
WIRING DIAGRAM
Black
Red
To Thermopile
Figure 11 - Wiring Diagram
13. Set remote control and receiver to same
address using dip switches (see Figures
9 and 10 for address locations). Switch
#8 must always be in the ON position
(down).
IHP.us.com
126916-01A 5
www.desatech.com 5114370-05C
Piezo
Ignitor
Control
Knob
Figure 12 - Control Knob in OFF Position
CAUTION: After shutting
off appliance, wait at least ve
minutes before reigniting. This
will allow the safety interlock
to reset.
OPERATION
WARNING: If you do not fol-
low these instructions exactly,
a re or explosion may result
causing property damage, per-
sonal injury or loss of life.
Follow all safety information given in your ap-
pliance owner’s manual under Operation.
WARNING: Do not force the
control knob on the gas valve.
Use only your hand to turn the
knob. If knob does not move by
hand, valve should be replaced
by a trained service technician.
LIGHTING
INSTRUCTIONS
1. With remote control turned off, press
lightly and turn the control knob clock-
wise to the OFF position. Wait ve
minutes for any gases to escape that may
have accumulated.
2. Press lightly and rotate control knob coun-
terclockwise to the PILOT position.
Holding knob pressed in, push the piezo
ignitor to light pilot. Keep knob pressed in
for at least 30 seconds until a strong pilot
ame is present. Release the knob.
3. Turn the control knob counterclockwise
to the ON position. The gas valve
is ready to be operated by the remote
control.
4. To shut off burner and leave pilot lit, turn
control knob clockwise to the PI-
LOT position.
TO TURN GAS OFF
TO APPLIANCE
Shutting off Fireplace
1. Turn the control knob clockwise to
the OFF position.
2. Close equipment shutoff valve.
OPERATING
REMOTE CONTROL
Note: To operate appliance with remote
control, it is necessary that the pilot ame be
lit and that the thermopile is hot enough to
supply the power required by the gas valve.
The gas valve control knob must be in the
ON position.
Note: The receiver has a temporary memory
to store the commands sent by the remote
control. When a command is received, an
acoustic signal is sounded. The command
will be executed as soon as allowed by the
control logic of the receiver. Commands given
too quickly after the unit is turned on or off may
not be executed immediately.
Turn On Appliance
Press the ON key (|) on remote control (see
Figure 13). The main burner will come on and
the receiver will give a signal that the com-
mand has been received.
Note: The ame height will be at maximum
for 5 seconds to allow proper ignition of the
burner. The receiver will not recognize an
increase or decrease for the ame height
during this 5 seconds.
Turn Off Appliance
Press OFF key (0) on remote control to turn
appliance off. An acoustic signal will be give
by the receiver that the command has been
received.
IHP.us.com 126916-01A
6
www.desatech.com 114370-05C6
Note: The step motor modulator will drive the
ame height to maximum to prepare for the
next ignition. If the ON command is sent be-
fore this is completed, it will not be recognized
until the modulator has reached the maximum
ame height position.
Flame Height
Use the up or down arrow keys to adjust the
ame height to the desired level (see Figure
13). There are six ame height levels. A signal
is given from the receiver to conrm the com-
mand was received.
Low Battery Detection and Backup
When the receiver detects low batteries it will
do one of the following:
• three acoustic signals are generated
• the appliance goes off
• commands given by the remote are ignored
by the receiver
When the batteries are replaced, the receiver
will restart its normal operation. When the
batteries are low, the appliance will not start
using the remote. You will still be able to turn
the unit on manually with the backup switch
on the receiver in the MAN position.
Figure 13 - Remote Control
ON
Key (|)
OFF
Key (0)
DOWN Key
to Decrease
Flame
UP Key to
Increase
Flame
Indicator
Light
Time-out
If the appliance is turned on and the receiver
does not receive and command for 24 hours,
it will turn the appliance off.
IHP.us.com
126916-01A 7
www.desatech.com 7114370-05C
NOTES
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
IHP.us.com 126916-01A
8
126916-01 Rev. A 03/14
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
IHP.us.com
P126916-01
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Astria Fireplaces Cascade Instruction Sheet

Type
Instruction Sheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI