Astria Fireplaces Devonshire - Legacy is a gas fireplace that provides supplemental heat for your home. It features a realistic log set and glowing ember bed, creating a cozy and inviting ambiance. With its convenient remote control, you can easily adjust the flame height and temperature to suit your comfort level. The fireplace also includes a safety screen to protect against accidental burns, making it a safe and enjoyable addition to any room.

Astria Fireplaces Devonshire - Legacy is a gas fireplace that provides supplemental heat for your home. It features a realistic log set and glowing ember bed, creating a cozy and inviting ambiance. With its convenient remote control, you can easily adjust the flame height and temperature to suit your comfort level. The fireplace also includes a safety screen to protect against accidental burns, making it a safe and enjoyable addition to any room.

Removing Barrier/Glass Door
Gloves must be worn when removing/replacing glass door. If glass
is broken, tape remaining glass frame before removing.
1. Remove bottom access panel.
2. Remove barrier by holding the barrier in front of the glass door
and slide it up into the channel underneath the upper front face
to release it from bottom channel then pull it out and away from
the fireplace (see Figure 1a, page 2).
3. Unlock 2 door latches on bottom of firebox.
4. Tilt open glass door 30° from bottom of firebox and lift up to
release door from firebox top retainer (see Figure 2, page 2).
5. To replace the barrier and glass door, reverse steps above.
WARNING: Reinstall any barrier removed before
operating the fireplace. The barrier is designed to
reduce the risk of burns from hot glass. Do not operate
the fireplace without the barrier installed.
IHP.US.com
This conversion kit must be installed by a qualified
service agency.
Read these instructions completely before installing this conversion kit.
Before proceeding, make sure gas control valve is in the OFF posi-
tion, all electrical power to the appliance is off and fireplace is cool
to the touch.
CAUTION: The gas supply shall be shut off prior to disconnect-
ing the electrical power before proceeding with the conversion.
Parts included with this kit:
Part No. Description Quantity
127179-01 Instruction Sheet 1
23773 Burner Orifice LP (#54) 2
127216-01 Conversion Label 1
106080-01 Conversion Information Label 1
125132-01 Set Screw #51 1
125240-02 Pilot Orifice LP (0.011") 1
Tools Required
• 3/8" Hex Socket Wrench or Adjustable Wrench
• 7/8" Open End Wrench or Adjustable Wrench
• 3/4" Open End Wrench or Adjustable Wrench
• Slotted Screwdriver
• Needle Nose Pliers
• #2 Short Phillips Screwdriver
• Thread Sealant (Resistant to Propane/LP)
ACCESSING FIREPLACE
The gas control valve and main burner orifice are located under firebox
floor of appliance and are accessed by removing bottom access door.
2 orifices are located in burners and are accessed by removing the
bottom access panel, barrier, glass door and burner.
Removing Bottom Access Panel
Remove bottom access panel by pulling top end forward and away
from appliance (see Figure 1). To replace removed item, reverse
procedure above. Figure 1 - Removing Bottom Access Panel
Bottom Access
Door
Barrier
PCDE-36D (F1108) CONVERSION KIT
INSTALLATION INSTRUCTIONS
For use when Converting Devonshire36TEN Fireplaces
From Natural Gas to Propane/LP Gas
P127179-01
P/N 127179-01 Rev. B 01/2015
For more information, visit IHP.US.com
IHP.US.com 127179-01B
2
Grate
Base
Burner
Base
Rear
Orice
Logset
Bulkhead
Fitting
BURNER ORIFICE CONVERSION
1. Remove andiron by lifting up and away from back of fireplace
(see Figure 3).
2. Carefully lift 3 loose logs from log stack.
3. Remove hex nuts that attach pilot shield and grate base to burner
base and 2 screws on side of pilot shield top.
4. Remove main burner from grate base by removing screw located
at right inner corner of firebox, and lifting up and toward the right
(see Figure 3).
5. Remove log set with grate base by holding sides of grate base
and lifting carefully to clear front burner orifice on right and pilot
shield on the left.
6. Remove NG orifice from elbow and bulkhead fittings. Apply a
light amount of propane/LP resistant sealant to threaded end of
propane/LP orifices (#54) supplied with kit. Thread propane/LP
orifices into fittings and tighten.
7. Adjust front burner air shutter to fully open and rear tube burner
air shutter to fully open.
8. Reinstall log set with grate base, main burner and loose logs
removed in step 2, 3 and 4.
GAS CONTROL VALVE CONVERSION
The gas control valve is convertible from propane/LP to natural gas
by a simple rotary knob located on the front face of the valve (see
Figure 4, page 3).
1. Remove the black cap by pulling the cap straight off. Note: the position
of the marker on the shaft of the simple rotary knob. This mark will
point to NAT to LP that indicates the type of gas the valve is set on.
2. To convert the control valve back to the factory setting (LP), push
in the simple rotary knob and rotate 90°. Note: the marker will
now point to LP and the shaft will stay in.
3. After the conversion has been made, check the outlet pressure
with a manometer. The factory setting on the internal regulator
is 3.5" w.c. for natural and 10.5" w.c. for propane/LP.
4. Replace black cover cap.
5. Remove flow control set screw and replace with set screw #51
provided with this kit.
Note: in replacement and conversion use only new parts provided.
When converting to different gas you must also change pilot and
burner orifices.
Main
Burner
Andiron
Assembly
Pilot
Shield
Top Pilot
Shield
Front
Orice
Elbow
Fitting
Air
Shutter
Figure 3 - Removing Orifice for Conversion (Valve Shown
Removed from Base for Clarity
Figure 1a - Removing Barrier
Channel
Barrier
Frame
Slot
Figure 2 - Removing Glass Door
Glass Door
Door Latch
IHP.US.com
127179-01B 3
Figure 4 - Change Simple Rotary Knob from LP to NAT and
Replace Set Screw
Lighting Instruction Plate
Conversion Label
Pilot Adj.
Inlet
Outlet
NATURAL TO PROPANE
CONVERSION SHAFT
(UNDER CAP)
LP
NAT
NAT
LP
Main
Pilot
Flow
Control
Set
Screw
Pilot
Bracket
Pilot Hood
Pilot
Orice
Pilot Barrel
Pilot Clip
Figure 5 - Apply Conversion Labels over Existing Certification
Label on Lighting Instruction Plate
CONVERSION LABELING AND PLACEMENT
1. Apply conversion label over top of existing certification label (see
Figure 5). Existing certification label is located on lighting instruc-
tions plate inside gas valve compartment area. With permanent
ink, print previous model number on label in space provided (see
Figure 6).
2. After filling data required on conversion information label (see
Figure 7), affix it to floor of appliance where it is easily seen when
bottom access door is removed.
Conversion Label
VENTED GAS FIREPLACE
Conversion Kit Model
Type of Gas
Previous Model #
PFS
®
Figure 6 - Print Previous
Model Number on
Conversion Label
Figure 7 - Conversion
Information Label
PILOT ORIFICE CONVERSION
1. Remove pilot hood from barrel using tweezers or needle nose
pliers to open clips (see Figure 8).
2. Remove pilot orifice from inside barrel with slotted screwdriver.
3. Replace pilot orifice with orifice supplied with this kit. Insert open
end of new pilot orifice inside barrel and thread pilot orifice with
slotted screwdriver.
4. Reinstall pilot hood into barrel then install clip to secure pilot
hood.
IMPORTANT: Be careful not to bend or kink aluminum tubing
during conversion. Make sure pilot hood and orifice are properly
mated and aligned after finishing this conversion.
Figure 8 - Converting Pilot Orifice
CONVERSION INFORMATION LABEL
This appliance was converted on
___ - ___ - ___ to ______________ gas
with Kit No. _______________________
by _____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
(name and address of organization making
this conversion), which accepts the
responsibility that this conversion has been
properly made.
106080-01
Day Month Year
FINAL PREPARATION
1. Leak check gas control and any connections you've made be-
fore operating appliance. Refer to Checking Gas Connections in
owner's manual.
2. Reinstall glass door and close latches.
3. Replace barrier and reinstall bottom access panel.
The conversion is now complete.
To operate your fireplace, refer to Operating Fireplace in your appli-
ance owners manual.
Innovative Hearth Products reserves the right to make changes at any time, without
notice, in design, materials, specifications, prices and also to discontinue colors, styles
and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2014 IHP LLC
P/N 127179-01 Rev. B 01/2015
P127179-01 1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
1-800-655-2008
IHP.US.com
WARNING: Test all gas piping and connections,
internal and external to unit, for leaks after installing
or servicing. Correct leaks at once.
WARNING: Never use an open flame to check for
a leak. Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct all
leaks at once.
WARNING: This conversion kit shall be installed
be a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction.
If the information in these instruction is not followed
exactly, a fire, explosion or production of carbon mon-
oxide may result causing property damage, personal
injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The
installation is not proper and complete until the opera-
tion of the converted appliance is checked as specified
in the manufacturer's instructions supplied with the kit.
You may have further questions about installation, operation, or
troubleshooting. If so, contact INNOVATIVE HEARTH PRODUCTS
at 1-800-655-2008. When calling please have your model and serial
numbers of your heater ready.
You can also visit our web site at
IHP.US.com.
TECHNICAL SERVICE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Astria Fireplaces Devonshire - Legacy Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet

Astria Fireplaces Devonshire - Legacy is a gas fireplace that provides supplemental heat for your home. It features a realistic log set and glowing ember bed, creating a cozy and inviting ambiance. With its convenient remote control, you can easily adjust the flame height and temperature to suit your comfort level. The fireplace also includes a safety screen to protect against accidental burns, making it a safe and enjoyable addition to any room.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI