Soyal AR-725E-M User manual

Category
Security device components
Type
User manual

This manual is also suitable for

SOYAL
ACCESS CONTROL SYSTEM
®AR-725E-M / AR-725E / AR-725X V090819
a.
d. e.
A.
A1.
A2. A3.
B.
E.
B.
C.
F.
C. H.G. D.
D.
b. c.
P1
P1
P5
P5
P2
P2
P6
P6
P3
P3
P7
P7
P4
P4
P8
P8
d x1
b x2
a x2
c x2
e x2
d x1
c x2
2C.
1
c.
A.
B.
3
4
5
A. B. C.
6
A.
B.
D.
7
8
A.
C.
g.
d.
F.
1
f.
A1.
F.
E.
2
4
5
e.
3
A3.
A1.
G.
1
f.
2
3
e.
b. A2.
A1.+A3.
H.
4
5
a.
D.
Contents
AR-725E-M
AR-725E
AR-725X
1Products
1Products
1Products
2User Guide
2User Guide
3Terminal Cables
3Terminal Cables
4Tools
4Tools
2Tools
Pull the cables from the square access hole of the mounting plate C.
Use a screwdriver to screw the metal plate C to the wall.
Take off the plastic mounting plate B from the body A, and pull the cables
through the access hole of C and B, then connect to the body A.
Assemble plate B with the body A, and embed the water proof strip D
onto the plastic side frame.
Assemble the body A onto the mounting plate C with the Allen key and
screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Use a screwdriver to screw the base F onto the wall.
Attach the water proof gasket to the body A1, and pull the cables
from the square hole of the base F, and connect to the body A1.
Assemble the body A1 with the base F.
Screw A1 and F tight with the Allen key and screws (accessories
supplied).
Turn on the power and LED will light and beep will sound.
Put on G, and attach A1 onto the plastic plate A3, and screw it with
the Allen key and screws (accessories supplied).
Put the ring O on the metal frame, and put them together onto the
reader A1+A3, and screw them and buckle up the 4 buckles on the
back.
Embed the water proof strip D onto the frame side of the base.
Following by the install process of AR-725E-M.
Button Head Pozidriv
Tapping Screw: M3x10
Security Torx Screw:
M3.5x15
Flat Head Cap Philips
Tapping Screw: 4x19.1
Button Head Pozidriv
Slotting Screw: 2.5x10
Flat Head Hex Socket
Screw: M3x8
Installation
AR-725E-M
AR-725E
AR-725X
Parts Description
V090819
8
7
6
5
4
3
2
1
1
2
1
2
3
4
5
6
7
6
5
4
3
2
1
6
5
4
3
2
1
3
2
1
1
2
4
3
2
1
P1
P5
P2
P6
P3
P7
P4
P8
AR-321H
EXIT
1
2
3
4
5
6
7
8
EXIT
1
2
3
4
5
6
7
8
E
N.C.
COM
PB
12V
GND
12V
GND
Exit Switch
12V
GND
12V
GND
12V
GND
12V
GND
12V
GND
N.O.
GND
N.O.
GND
N.O.
COM
PB
12V
GND
P1 P1
3 Door Controller
Illuminated Touch-panel
Notice
1. Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.
2. Cable selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring. Use CAT5 for TCP/IP connection.
3. Power supply: Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the
reader malfunction. The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.
4. Keypad lock: If 725E does not link [TCP / IP connection], the 725E keypad locks about 5 seconds after power transmission.Setting will work after
725E switches to stand-alone mode.
Connector Table
Wire Application
Door Relay
Common-COM-Point
Door Sensor
Exit Switch
Alarm Relay
Power
Wire Application
Beeper
LED
Door Output
Wiegand
Wire Application
Reservation
Reservation
TCP/IP Output
Reservation
Wire Application
WGB Exit Switch
WGB Door Sensor
WGA Exit Switch
WGA Door Sensor
Wire Application
Anti-Tamper
Switch
Wire Application
TTL Serial Port
Wire Application
RS-485 for Lift
Controller
P1Cable: P5Cable:
P6Cable:
P7Cable:
P8Cable:
P2Cable:
P3 P4Cable:
Description
(N.O.)DC24V1Amp
(N.C.)DC24V1Amp
(COM)DC24V1Amp
Negative Trigger Input
Negative Trigger Input
Transistor Output
Max. 12V/100mA
(Open Collector Active Low)
DC 12V
DC 0V
Description
Beeper Output
5V/100mA, Low
Red LED Output
5V/20mA, Max.
Green LED Output
5V/20mA, Max.
Transistor Output
Max. 12V/100mA
(Open Collector Active Low)
Wiegand DAT: 0 Input
Wiegand DAT: 1 Input
Description
Reservation
Reservation
Net - TX+
Net - TX-
Net - RX+
Net - RX-
Reservation
Description
Negative Trigger Input
Negative Trigger Input
Negative Trigger Input
Negative Trigger Input
Description
N.C.
COM
N.O.
Description
Transistor Output
Max. 12V/100mA
(Open Collector Active Low)
GND
Description
RS-485(B-)
RS-485(A+)
Color
Blue White
Purple White
White
Orange
Purple
Gray
Thick Red
Thick Black
Color
Pink
Yellow
Brown
Blue White
Thin Green
Thin Blue
Color
-
-
Orange White
Orange
Green White
Green
-
Color
Purple White
Orange White
Purple
Orange
Color
Red
Orange
Yellow
Color
Black White
Black
Color
Thick Green
Thick Blue
Wire
1
2
3
4
5
6
7
8
Wire
1
2
3
4
5
6
Wire
1
2
3
4
5
6
7
Wire
1
2
3
4
Connect to Electric Bolt
Electric Bolt
Magnet Lock
Controller Controller
Push Button Push Button
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Connect to Magnet Lock
Wiring Diagram
Wire
1
2
3
Wire
1
2
Wire
1
2
SOYAL
ACCESS CONTROL SYSTEM
®AR-725E-M / AR-725E / AR-725X V090819
EXIT
1
2
3
4
5
6
7
8
N.C.
N.O.
COM
CTL
12V
1
2
3
4
5
6
7
8
AR-321H
AR-321H
Door Sensor
ALM
12V
GND
12V
GND
12V
GND
12V
GND
12V
GND
12V
GND
12V
GND
N.O.
GND
N.O.
COM
PB
12V
GND
P1P1
BZ
RLED
GLED
WG 0
WG 1
12V
GND
BZ
RLED
GLED
WG 0
WG 1
12V
GND
1
2
3
4
5
6
7
8
1
2
3
4
5
6
1
2
3
4
5
6
BZ
RLED
GLED
WG 0
WG 1
BZ
RLED
GLED
WG 0
WG 1
12V
GND
P3
P4
P1
N.C.
N.O.
COM
CTL
12V
E
BZ
RLED
GLED
WG 0
WG 1
12V
GND
1
2
3
4
5
6
7
8
1
2
3
4
1
2
3
4
5
6
EXIT
12V
GND
Exit Switch
12V
GND
P3
P7
P1
BZ
RLED
GLED
Door Output
WG 0
WG 1
PB-A
DS-A
PB-B
DS-B
AR-321H
Connect to Electric Strike
Connect to 2 Readers
Electric Strike Alarm
Controller
Controller
Reader A
Reader A
Reader B
Controller
Controller
Push Button
Push Button
Door Sensor
Door Sensor
Relay Outpot Module
Relay Outpot
Module
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Connect to Door Sensor
Connect to Door Controller
Electric Bolt
Adding and Deleting Tag
Mode4/Mode8
Deleting All Tags
Input 123456 (or Master Code)29 29
Deleting the Single Tag
Input 123456 (or Master Code)10 SSSSS EEEEE
[e.g.] Delete User Address: 00058
Access programming mode10 00058 00058
9
9
Deleting a batch of Tags
Input 123456 (or Master Code)10 SSSSS EEEEE
[e.g.] Delete User Address: 00101~00245
Access programming mode10 00101 00245
9
9
Adding the Single Tag or the Random tags
Input 123456 (or Master Code)19 UUUUU 00001Get Tag close to RF Area(Present the tag to the controller.)OK (Memory location number)
[e.g.] User Address NO.100 and NO.101 have 2 pcs of random tags:
Access programming mode19 00100 00001Get Tag close to RF AreaOK
P.S. The First tag has now been added, present the rest of the tags one after the other to add them to the system as well.
Input 123456 (or Master Code)19 UUUUU QQQQQGet Tag close to RF Area (Present the tag with the lowest number to the controller.)
OK (Memory location number)
Adding the Sequential tags
[e.g.] User Address NO.101 to NO.120 have 20 pcs of sequential tags:(62312~62332)
Access programming mode19 00101 00120Get Tag close to RF Area(only use the tag NO.62312)OK
Mode6
At the Mode 6, User Address = Card Code
Adding Tag
Input 123456 (or Master Code)11 SSSSS EEEEEOK
[e.g.] Add User Address: 00100~01254
Access programming mode11 00100 01254OK
Deleting All Tags
Input 123456 (or Master Code)29 29
Deleting Tag
Input 123456 (or Master Code)10 SSSSS (or )EEEEEOK
[e.g.] Delete a tag with card code 62362
Access programming mode10 62362 62362OK
9
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
V090819
3 Door Controller
Illuminated Touch-panel
Mode 6 the number of users up to 65535, largely because of its read-only CARD CODE, unlike Mode4/Mode8 shall read the SITE CODE and CARD CODE.
Mode Support
Networking/
Stand-Alone
Stand-Alone
Networking/
Stand-Alone
User
Capacity Access Mode
M4
M6
M8
V
X
V
V
X
V
V
X
V
V
X
V
64
X
64
unlimited
X
unlimited
30,000
X
30,000
16,000
(0~15,999)
65,535
(1~65535)
16,000
(0~15,999)
Auto-show
Duty time
Event
Capacity
120
Holidays Duress Time
Zone
Lift
Control
Anti-pass-
back
1.Card only
2.Card and PIN (4-digit PIN)
3.Card or User address (5-digit) + Individual PIN
(4-digit individual PIN)
1.Card only
2.Card and PIN (4-digit public PIN= Arming PWD)
3.Card or PIN (4-digit public PIN= Duress code)
1.Card only
2.Card and PIN (4-digit individual PIN)
3.Card or PIN (4-digit individual PIN)
Changing the Master Code
Access programming mode09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] If want to changing the Master Code= 876112, input 12345609 876112876112
Exiting
Input
Access programming mode00 NNN MMM AAA BBB
[NNN= Node ID: 000~254; MMM=725E Door NO.:1~255; AAA=WGA Door NO.:1~255; BBB=WGB Door NO.:1~255]
B. Changing the Node ID of Reader
Access programming mode04 N [N=4/6/8]
C.Setting up the control mode (M4/M6/M8)
Programming
A. Entering and Exiting Programming Mode
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112Access programming mode
Enable device
Access programming mode20 U DDD [Please refer to function default value for details.]
[e.g.] If the AR-725E set to exit reader, WGA set to access reader.
Access programming mode20 0 128 20 1 192 [Please refer to function default value for details.]
Enable/Disable auto open zone
Access programming mode20 U DDD [Please refer to function default value for details.]
[e.g.] If the AR-725E set to Enable aut open zone.
Access programming mode20 0 004 [Please refer to function default value for details.]
[e.g.] If the WG-B set to Enable aut open door without presenting card.
Access programming mode24 2 128 [Please refer to function default value for details.]
Enable/Disable auto open door without presenting card
Access programming mode24 U DDD [Please refer to function default value for details.]
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0
Enable card user
Access programming mode26 SSSSS EEEEE N [N=0 Enable/ N=1 Disable/ N=2 Reset]
NN: 16 sets of auto-open zone (NN=00~15)
HHMMhhmm=Starting time to ending time (e.g.: 08301200=08:30 to 12:00)
6543217H= 7 days of week + Holiday (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; 1: enable)
Setting up access time
Access programming mode08 U NN HHMMhhmm 6543217H
Individual PWD (M4/M8)
Card or PIN: Access programming mode12 UUUUU PPPP [e.g. User address: 00001 and PWD: 1234. Input 12 00001 1234 ]
Card and PIN: Access programming mode13 UUUUU PPPP [e.g. User address: 00001 and PWD: 1234. Input 13 00001 1234 ]
Public PWD (M6)
PIN only: Access programming mode15 PPPP [Input 4-digit PWD, default value: 4321]
Card and PIN: Access programming mode17 PPPP [Input 4-digit PWD, default value: 1234, disable PIN: 0000]
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to
monitor not only the access but also exit condition.
Door will keep opening after rst man ashing card. When the reader is stand-alone, supporting only 16 sets of auto-open zone by device setting.
Auto-open zone can extend up to unlimited sets by Networking.
D. Setting up the password
E. Anti-pass-back(M4/M8)
F. Auto Open Zone
SOYAL
ACCESS CONTROL SYSTEM
®AR-725E-M / AR-725E / AR-725X V090819
1
2
3
5
4
G. Lift control
Single oor
[e.g.] User address NO. 45 only can reach the elevator to the 24th oor: 27 00045 24
Access programming mode27 UUUUU LL
UUUU=User Address LL=Floor number (01~64 oor/stop)
Connect with AR- 401RO16B to control which oors the user will be able to access. [BAUD9600]
Set
(G)
Floor/ Stop
L
8
16
24
32
40
48
56
64
0
1
2
3
4
5
6
7
L
6
14
22
30
38
46
54
62
L
7
15
23
31
39
47
55
63
L
5
13
21
29
37
45
53
61
L
4
12
20
28
36
44
52
60
L
3
11
19
27
35
43
51
59
L
2
10
18
26
34
42
50
58
L
1
9
17
25
33
41
49
57
Please refer to below oor chart
Enable all devices: Access programming mode Enable particular device: Access programming modeU
Enable Arming status:
Disable Arming status:
Standby Mode
Standby Mode
Enter Program Mode
Card only
Card only
Card or Passcode
Card or Passcode
Card and Passcode
Card and Passcode
There is NO arming mode for M6. Factory default armingcode is: 1234. U=Reader unit (0=725E, 1=WGA, 2=WGB).
H. Setting Up the Arming
Conditions:
1. Arming is enabled
2.Alarm system connected
Application:
1. Door open too long: Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal: When power is off and then on, reader on arming bffore power off.
[e.g.] User address NO. 168 can reach only the 6th and 20th oor:
Access programming mode21 00168 0 00100000
21 00168 2 00001000OK
Multi oors
Access programming mode21 UUUUU G LLLLLLLL
[UUUUU=User address G: 8 sets of lift control (Input: 0~7) LLLLLLLL:
8 oors/stop setting (L=0=Disable, L=1=Enable)
Restoring Factory Settings
Appendix-Firmware Upgrade
Reset all device parameters and user card data
Reset all user card data:
Access programming mode29 29
Reset IP Setting:
Press “IP Resent Button” of main board for few seconds
Reset all device parameters and user card data:
Access programming mode29 29 9
Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” software
Update the rmware
[Please login the SOYAL web to download the new ISP Firmware.]
1. Input the Target Address and Port
2. [Load Fide] open the documents that have the new ISP Firmware
3. Click the new ISP Firmware and [Open] it
4. Click [Update Device] to start the rmware update
5. Till the screen shown [Program Completed]
Execute the software
The software is within SOYAL CD or Login the
SOYAL web to downloads
Enable all devices
Induct valid card Input 4 digit
arming code
Enable particular device
Induct valid card Input 4 digit
arming code U
Disable particular device
Induct valid card Input 4 digit
arming code U
Input 5 digit user address Input 4
digit pass code → → Input 4 digits
arming code or U
Induct valid card Input 4 digit pass
code Input 4 digits arming
code or U
Disable all devices
Induct valid card Input 4 digit
arming code 9
Input 5 digit user address Input 4
digit pass code → → Input 4 digits
arming code or U
9
Induct valid card Input 4 digit pass
code Input 4 digits arming
code or U
9
V090819
3 Door Controller
Illuminated Touch-panel
IP Setting
Log-in User Password
When you choose the "Networking Setting" or "User Password" at rst.
Log-in window will pop out and please input
At the Factory Default
User name: admin
Password: No as default value,so please just press “OK” to log-in
Turn on your Web Browser and input factory default IP
address: http://192.168.1.127
adminadmin
Networking Setting
You will nd initial IP Address 192.168.1.127 and check
MAC Address is the same as sticker on Ethernet Module
device. Please revise IP address you want, and then click
Update” button. After updating the IP, please re-connect
the Web Browser by new IP address.
User Password
The password composes of 10 characters at most, it can be
either A~Z or 0~9.
Change the log-in password to lock the IP setting of
Ethernet Module.
Max. 10 characters allowed
(Composed of A~Z and 0~9)
After changed and updated IP to
new address, re-connect the Web
Browser by new IP address.
If the AR-725E of the IP address
has changed We must enter the
new IP address.
Show which computer is linking
on Ethernet Module.
Current IP address of the AR-725E.
Page menu
Current State
Online Status is able to monitor and show which computer is linking on
Ethernet Module
IP Setting
Monitor the on-line computer
Change the Log-in information
SOYAL
ACCESS CONTROL SYSTEM
®AR-725E-M / AR-725E / AR-725X V090819
Command List
Function
Entering programming mode
Exiting programming mode
Exiting programming mode and
enabling all device into arming
status. (Including 725E, WGA
and WGB)
Exiting programming mode and
enabling each device into arming
status. (725E, WGA or WGB)
Node ID setting
Door relay time setting
Alarm relay time setting
Control mode setting
Arming delay time setting
Alarm delay time setting
Master card setting
(For entering programming mode
instead of pressing master code)
Auto-open zone setting
Master code settings
Suspend or delete tags
M4/8: Recover tag
M6: Setting up a batch of users
to access by card only
Setting up the PWD/PIN
Setting up the PWD/PIN
Arming output setting
M4/M8: Duress code setting
M6: Public PIN setting
(Card or PIN)
M4/M8: Arming PWD setting
M6: Public PIN setting
(Card and PIN)
Enabling or Disabling into arming
status
Enabling or Disabling target unit
into arming status
Enabling all units into arming
status
Disabling all units into arming
status
Mode
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
M6
M4/M8
M4/M8
M4/M6/M8
M4/M8
M6
M4/M8
M6
M4/M6/M8
Command
PPPPPP
U
00 NNN MMM AAA BBB
02 U TTT
03 TTT
04 N
05 TTT
06 TTT
07 SSSSS EEEEE
08 U NN HHMMhhmm
6543217H
09 PPPPPPRRRRRR
Suspend= 10 SSSSS EEEEE
Delete= 10 SSSSS EEEEE
11 SSSSS EEEEE
11 SSSSS EEEEE
12 UUUUU PPPP
13 UUUUU PPPP
14 TTT
15 PPPP
17 PPPP
Flashing a valid card and input
NNNN
Flashing a valid card an input
NNNN U
Flashing a valid card and input
NNNN
Flashing a valid card and input
NNNN
9
Exposition
PPPPPP: Master Code, (Default value: 123456)
U= Enable target unit (0=725E, 1=WGA, 2=WGB)
NNN= Node ID of 725E: 001~254; MMM= Door number of 725E
AAA= Door number of WGA; BBB= Door number of WGB
U= Enable target unit (0=725E, 1=WGA, 2=WGB)
TTT= Door relay time
(Input 000=Normal open / Input 001~600=1~600 sec. /
Input 601~609=0.1~0.9 sec. )
TTT= Door relay time
(Input 000=Normal open / Input 001~600=1~600 sec.)
N= Mode: 4/6/8
Base on second, range: 001~255
Base on second, range: 001~255
Input a user or a batch of user as the master card: 00000~15999
SSSSS= starting user address; EEEEE= ending user address
U= Enable target unit (0=725E, 1=WGA, 2=WGB)
NN: 16 sets of auto-open zone (Range: 00~15)
HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
6543217: 7 days of week -Sat/Fri/Thu/Wed/Tue/Mon/Sun
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
PPPPPP= New master code
RRRRRR= Repeat the new master code
= Suspend; = Delete
SSSSS= starting user address; EEEEE= ending user address
Recover the paused tag
SSSSS=starting Card Code; EEEEE= ending Card Code
UUUUU= user address; PPPP=4-digit individual PWD
(Access mode: Card or PIN)
UUUUU= user address; PPPP=4-digit individual PWD
(Access mode: Card and PIN)
Base on 1ms, range:1~255, default value=10, Input 0= Timeless
PPPP=4-digit PWD
(P.S. Duress code will be unavailable and as public PIN at
access mode “Card or PIN” of M6)
(Default value=4321; disable PIN=0000)
PPPP=4-digit PWD
(Default value=1234; disable PIN=0000)
NNNN=4-digit arming PWD
U=Enable target unit (0=725E, 1=WGA, 2=WGB)
9
9
V090819
SOYAL http://www.soyal.com
3 Door Controller
Illuminated Touch-panel
Function
Door close time
Adding tags by induct
Factory setting-1
Lift control setting: multi-doors
Add/Delete tags by closing tags
into RF area (M6 only)
AR-401RO16/ AR-401RO16B
relay time setting
Factory setting-2
Real time clock setting
Anti-pass-back
(Enable user)
Lift control setting: single door
Duress Function and Arming
output setting
Delete all tag
Same tag reading interval time
Auto ring the clock alarm
schedule
Holiday Setting
Exposition
Base on second, range: 000~255, default value: 15 sec.
UUUUU= User address; QQQQQ= the amount of card
U=Enable target unit (0=725E, 1=WGA, 2=WGB)
DDD=Function default value
(Please refer to function default value for details)
UUUUU=User address
G: 8 groups of lift control (Input range: 0~7)
LLLLLLLL: 8 oors/stop setting (0=Disable, 1=Enable)
N=0=Delete tag; N=1=Add tag
Close tag into RF area one by one.
MMM= Node ID of lift controller
TTT= relay time: 000~600=1~600 sec.
U= Enable target unit (0=725E, 1=WGA, 2=WGB)
DDD= Function default value
(Please refer to function default value for details)
YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec.
SSSSS=starting user address; EEEEE=ending user address
P=0=Enable; P=1=Disable; P=2=Initial
UUUUU=User Address; LL=Floor number (01~63 oor/stop)
Arming output: FFF= 008 (default value)
Duress Function: FFF= 000
Base on 10ms, range from 0 to 6000
SS= 16 sets auto alarm schedule, range 0~15
HHMM= HH:MM (ex. 0830: Ring bell at 08:30)
TT=Period of time to ring bell
(Base on second, range 01~99 sec.)
6543217: 7 days of week -Sat/Fri/Thu/Wed/Tue/Mon/Sun
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
MM= Month of year (01=Jan...10=Oct.)
DD= Date of month (01=1st day of month)
F= 0:Del; 1: Add
Mode
M4/M6/M8
M4/M8
M4/M6/M8
M4/M8
M6
M4/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
Command
18 TTT
19 UUUUU QQQQQ
20 U DDD
21 UUUUU G LLLLLLLL
22 N
23 MMM TTT
24 U DDD
25 YYMMDDHHMMSS
26 SSSSS EEEEE P
27 UUUUU LL
28 FFF
29 29
31 TTTT
32 SS HHMMTT 6543217H
35 MMDD F
Thanks for You
To have more detailed information, E-learning, and Q&A, please visits our website.
Function Default Value
20 U DDD
Function Option Value Application
Default Value
Time Attendance
Auto Re-lock
Auto Open
When Access Mode is "Card and PIN", Readers can skip pressing PIN code.
Exit by Push Button
Enable force Open
As Access/Exit Reader
Anti-pass-back
0: Yes
0: Disable
0: Disable
0: Disable
0: Disable
0: Slave
0: Exit
0: Disable
Networking
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking
Networking
Networking
001
002
004
008
016
032
064
128
1: No
1: Enable
1: Enable
1: Enable
1: Enable
1: Mater
1: Access
1: Enable
24 U DDD
Function Option Value Application
Default Value
Stop Alarm by...
Open door immediately without 1st card presented at auto open zone.
0: None
0: Disable
Networking/Stand-Alone
Networking/Stand-Alone
064
128
1: Push button/
Door Closed
1: Enable
[e.g.] DDD value of AR-725E to Enable "Auto Open" + "Exit by Push Button" + "Anti-pass-back" =004+016+128= 148
As a result of that, the command will be 20 0 148
U = Enable target unit (0=725E, 1=WGA, 2=WGB); DDD = Value
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8