FMI VTD-30PV-JHB Owner's manual

Type
Owner's manual
APPROVED
TESTED AND
LISTED BY
The OF-RC Kit Contains the following:
• 1-On/OffRemoteControlKitHRC100
• 2-Battery9V 111836-01
For more information, visit www.desatech.com
OF-RC (ON/OFF) REMOTE
CONVERSION KIT
For All Millivolt Cascade Natural and
Propane/LP Gas Logs
(NOT A GAS CONVERSION KIT)
ANSI Z21.60
CSA 2.26
• 1-Bracket 117074-01
• 2-Screw8-32x3/8" 111782-01
• 1-Instructionmanual 114370-04
WARNING: This conversion kit shall be installed
by a qualied service agency in accordance with the
manufacturer's instructions and all applicable codes and
requirements of the authority having jurisdiction. The
information on this instruction must be followed to mini-
mize the risk of re or explosion or to prevent property
damage, personal injury or death. The qualied service
agency performing this work assumes responsibility for
the proper conversion of this appliance with this kit.
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
WARNING: Improper installation, adjustment, al-
teration, service or maintenance can cause injury or
property damage. Refer to this manual for correct in-
stallation and operational procedures. For assistance
or additional information consult a qualied installer,
service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
www.desatech.com
114370-04B2
Figure 3 - Connecting Wire Terminals
Control
Valve
INSTALLATION
ThisOF-RCOn/OffRemoteKitisdesignedto
beusedonMVCascadeseriesVTD-18NV-
JHB,VTD-18PV-JHB,VTD-24NV-JHB,VTD-
24PV-JHB,VTD-30NV-JHBandVTD-30PV-
JHB.ThiscanalsobeusedonMVCascade
seriesthathasbeenconvertedtoHi-Loknob
VTD-HLCNandVTD-HLCP.
Installation Items Needed
Beforeinstallingthekit,makesureyouhave
theitemslistedbelow.
• Phillipsscrewdriver
• needlenoseplier
• 5/16"socketoratheadscrewdriver
OF-RC Conversion Kit or Replacement
Instructions
1. TurncontrolknobtotheOFFposition,and
shutoffgassupplytovalve.
2. Remove4screwsandfaceplate.See
Figure1.
3. Disconnectmanualswitchterminals.This
switchwillbereplacedbyOF-RCremote
kit.Discarddisconnectedswitchwiresor
position and secureto avoid contacting
withotherconnectorsandwires.
4. Install included 9V battery into receiver
(seeFigure2).
5. Connectthe"+"(positive)terminalofre-
ceivertoTHterminalofgasvalveandthe
"-"(negative)terminalofreceivertoTPTH
terminalofgasvalve(seeFigure3).
6. Installincluded9Vbatteryintohandheld
transmitter(seeFigure4).
7. Installreceiverusingincludedbracketand
screws(seeFigure5).
8. Reinstallfaceplateandscrews.
Figure 2 - Installing Battery into Receiver
Figure 1 - Removing Face Plate
Figure 5 - Installing Receiver and
Faceplate
9VBattery
Backof
Receiver
Screws
Faceplate
Screws
9-VoltBattery
Battery
Housing
Figure 4 - Installing Battery in Hand-Held
Remote Control Unit
Battery
Cover
Terminal
Wires
RemoteControlUnit
Faceplate
Bracket
Receiver
GasValve
GasValve
www.desatech.com
3114370-04B
OPERATING REMOTE
NOTICE: You must light the pi-
lot before using the hand held
remote control unit. Refer to
Lighting Instructions in your
appliance owners manual.
1. Afterlighting,letpilotameburnforabout
oneminute.TurncontrolknobtotheON
position.Adjust ame adjustment knob
anywherebetweenHIandLOonmodels
withHi/Loknobconversion.Slideselector
switchtotheREMOTEposition.
Note: Burners may light if hand-held
remote ON button was on when selector
switch was last turned off. You can now
turn the burners on and off with the hand-
held remote control unit.
IMPORTANT:Donotleave the selector
switch in the REMOTE or ON position
whenthepilotisnotlit.Thiswilldrainthe
battery.
2. On/Off Operation: Holdcontrolbuttonon
hand-heldremote until burner turns on.
Holdcontrolbuttonagainuntilburnerturns
off(seeFigure6).Whenturningburners
off,thepilotwillremainlit.
To Lock:Pressbothbuttonsonhand-held
remote control untillight stops ashing.
Hand-heldremotecontrolisnowlocked.If
reisonitwillbeturnedoffautomatically.
Inthelockedstate,lightwillnotlightup
whenanybuttonispressed.
To Unlock:Pressbothbuttonstogether
on hand-held remote control until light
stopsashing.Thehand-heldremoteis
nowunlocked.
IMPORTANT:BesuretopressON/OFF
buttonsonhand-heldremotecontrolunit
for up to 3 seconds to assure proper
operation.
Figure 6 - ON/OFF Hand-Held Remote
Control Unit
Control
Button
IndicatorLight
114370-04
Rev.B
05/08
NOTAUPC
11437004
DESAHeating,LLC
2701IndustrialDrive
BowlingGreen,KY42101
www.desatech.com
1-866-672-6040
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

FMI VTD-30PV-JHB Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI