Vexar CD36TN-M User manual

Category
Fireplaces
Type
User manual
Save this manual for future reference.
For more information, visit www.desatech.com
WARNING: If the information in this manual is not fol-


         


WHAT TO DO IF YOU SMELL GAS
 
Do not touch any electrical switch; do not use any

 

 

 -

DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
NATURAL OR PROPANE/LP GAS
MODEL CD36TN-M
www.desatech.com
118531-01A2
    -
-

      -




in accordance with the manufacturer's instructions and
the Manufactured Home Construction and Safety Stan-
dard, Title 24 CFR, Part 3280 in the United States or the
    





TABLE OF CONTENTS
Safety Information ............................................... 3
Product Identication ........................................... 4
Local Codes......................................................... 5
Product Features ................................................. 5
Pre-Installation Preparation ................................. 5
Location of Termination Cap ................................ 9
Venting Installation Instructions ......................... 10
Fireplace Installation.......................................... 18
Operating Fireplace ........................................... 28
Inspecting Burners............................................. 31
Conversion Instructions ..................................... 31
Cleaning and Maintenance ................................ 33
Troubleshooting ................................................. 35
Specications .................................................... 38
Replacement Parts ............................................ 38
Service Hints ..................................................... 39
Technical Service............................................... 39
Accessories ....................................................... 39
Illustrated Parts Breakdown and Parts List........ 40
Warranty Information ...........................Back Cover
www.desatech.com
118531-01A 3
   

    
-



-



  





WARNING: Do not allow fans



    



    
   



-

-
   
adults away from hot surface to




SAFETY INFORMATION
-




   



-

   



This replace must be installed by the O.E.M.
builder or by a qualied (certied or licensed)
service person. It has a sealed gas combustion
chamber that uses a coaxial pipe (pipe within a
pipe and having the same center) venting system.
It brings in fresh air for combustion through the
outer pipe and combustion gases are exhausted
through the inner pipe. If the glass door assembly
and venting pipe are not properly seated, con-
nected and sealed, carbon monoxide leakage
(spillage) can occur.
   Early signs of
carbon monoxide poisoning resemble the u, with
headaches, dizziness or nausea. If you have these
signs, the replace may not be working properly.
Get fresh air at once! Have replace serviced.
Some people are more affected by carbon monoxide
than others. These include pregnant women, people
with heart or lung disease or anemia, those under the
inuence of alcohol and those at high altitudes.
    Propane/LP and
natural gas are odorless. An odor-making agent is
added to the gas. The odor helps you detect a gas
leak. However, the odor added to the gas can fade.
Gas may be present even though no odor exists.
Make certain you read and understand all warnings.
Keep this manual for reference. It is your guide to
safe and proper operation of this replace.
www.desatech.com
118531-01A4
   -
dren when they are in the room


   
   

    

1. For propane/LP replace, do not place pro-
pane/LP supply tank(s) inside any structure.
Locate propane/LP supply tank(s) outdoors.
To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lbs.
capacity.
2. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not use
any phone in your building
immediately call your gas supplier from a
neighbors phone. Follow the gas supplier's
instructions
if you cannot reach you gas supplier, call the
re department.
3. Never install the replace
in a recreational vehicle
in windy or drafty areas where curtains or
other combustible (ammable) objects can
make contact with the replace front
in high trafc areas
4. Turn replace off and let cool before servicing,
installing or repairing. Only a qualied service
person should install, service or repair this
replace. Have replace inspected annually
by a qualied service person.
5. You must keep control compartments, burn-
ers and circulating air passages clean. More
frequent cleaning may be needed due to ex-
cessive lint and dust from carpeting, bedding
material, etc. Turn off the gas valve and pilot
light before cleaning replace.
6. Have venting system inspected annually by a
qualied service person. If needed, have vent-
ing system cleaned or repaired. See Cleaning
and Maintenance, page 33.
SAFETY INFORMATION
Continued
7. Do not use any solid fuels (wood, coal, paper,
cardboard, etc.) in this replace. Use only the
gas type indicated on replace nameplate.
8. This appliance, when installed, must be elec-
trically grounded in accordance with local
codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA
C22.1.
9. Do not use replace if any part has been ex-
posed to or under water. Immediately call a
qualied service person to arrange for replace-
ment of the unit.
10. Do not operate replace if any log is broken.
11. Do not operate fireplace with glass door
removed, cracked or broken.
12. Provide adequate clearances around air
openings.
PRODUCT
IDENTIFICATION
Figure 1 - Direct-Vent Fireplace
Nailing
Flange
Top Vent
Flue Collar
Door
Latch
Log
Set
Ember
Tray
Junction
Box
Lower
Louver
Panel
Control Valve
Variable Input
Adjustment
Piezo Ignitor
with Optional
Remote
and Blower
Control Mount
Upper Louver Panel
Glass
Door
Assembly
www.desatech.com
118531-01A 5
LOCAL CODES
Install and use replace with care. Follow all local
codes. In the absence to local codes, use the cur-
rent National Fuel Gas Code ANSI Z223.1/NFPA
54* (USA) or the current CSA-B149.1 Installation
Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
These are a few facts that can help you understand
and enjoy your direct-vent replace:
The dedicated top vent for this replace is suited
for any application where height is necessary
to terminate the venting system either through
the roof (vertical) or to gain sufcient height
and offset to vent to an outside/exterior wall
(horizontal).
The vent pipe installation is very important to
allow for proper operation. You must select the
appropriate vent kits and components for your
application and follow the venting instructions
to plan your installation.
This replace may be installed in any room pro-
vided that all rules of the housing authority and
these installation instructions are followed.
This replace is equipped with a millivolt gas
control system that does not require electricity to
operate. A piezo ignitor is provided to light the
pilot without using matches or lighters.
This model can accept an optional circulating
air blower when 120 VAC connection is sup-
plied. If you plan to install an optional blower,
do not forget to wire the replace outlet when
framing.
Each time you turn on your replace, you may
notice some amount of condensation on the in-
side of the replace glass. This is normal and will
disappear after 10-20 minutes of operation.
Your direct-vent gas replace system (replace
and venting) is a balanced and sealed gas oper-
ating unit. It is highly efcient because it uses
outside air for combustion while independently
heating the indoor air.
Figure 2 - Common Fireplace Locations
Flush with
a wall
Through exterior wall
enclosed in a chase
Corner
installation
PRE-INSTALLATION
PREPARATION
LOCATION AND SPACE
REQUIREMENTS
Determine the safest and most efcient location for
your DESA/Vexar direct-vent replace. Make sure
that rafters and wall studs are not in the way of the
venting system. Choose a location where the heat
output is not affected by drafts, air conditioning
ducts, windows or doors. Figure 2 shows some
common locations. Be aware of all restrictions and
precautions before deciding the exact location for
your replace and termination cap.
When deciding the location of your replace,
follow these rules:
Do not connect this replace venting to a chim-
ney ue serving a separate solid fuel burning
replace or appliance.
Due to high temperatures, do not locate this
replace in high trafc areas, windy or drafty
areas or near furniture or draperies.
Proper clearances must be maintained.
If your replace is to be installed directly on
carpeting, vinyl tile or any combustible material
other than wood, it must be installed on a metal
or wood panel extending the full width and depth
of the replace. See Figure 3, page 6.
Your replace is designed to be used in zero
clearance installations. Wall or framing material
can be placed directly against any exterior sur-
face on the back, sides or top of your replace,
except where standoff spacers are integrally
attached. If standoff spacers are attached to your
replace, these spacers can be placed directly
against wall or framing material. See framing
details on page 6.
If you plan on installing a television or enter-
tainment center recessed above your replace, it
is recommended that you maintain a minimum
18" above top of louver opening.
www.desatech.com
118531-01A6
When locating termination cap, it is important
to observe the minimum clearances shown in
Figure 7, page 8.
If recessing into a wall, you can avoid extra
framing by positioning your replace against
an already existing framing member.
Do not recess termination cap into a wall or
siding.
You may paint the termination cap with 450ºF
(232ºC) heat-resistant paint to coordinate with
the exterior nish.
There must not be any obstruction such as
bushes, garden sheds, fences, decks or util-
ity buildings within 24" from the front of the
termination cap.
Do not locate termination cap where excessive
snow or ice build up may occur. Be sure to
clear vent termination area after snow falls to
prevent accidental blockage of venting system.
When using snow blowers, do not direct snow
towards vent termination area.
PRE-INSTALLATION
PREPARATION
Continued

This direct-vent gas replace heater is packaged
with:
one box containing a 4 piece log set located on
the burner in the rebox.
one bag containing the owners manual with
installation instructions, operators guide, and
warranty information.
one bag of glowing ember material.
one bag of vermiculite hearth treatments.
Remove the shrink-wrap securing the 2 carton
trays to the unit. Lift the top carton tray off and
remove the 4 corner posts. Discard the bottom tray
once the unit is moved into position.
CLEARANCES
Minimum clearances to combustibles for the re-
place are as follows:
Back and sides* 0"
Perpendicular walls 12"
Floor 0"
Ceiling to louver opening 40"
Front 36"
Top of Standoffs 0"
Vent Surfaces 1" (See venting
instructions fo r
s p e c i f i c v e n t
clearances.)
Mantel Clearances ( S e e M a n t e l
Clearances, page 8
for specifics on
mantel clearances.)
*Combustible material with a maximum thick-
ness of 5/8" may be ush with the top front of
replace.
    -







    
-



FRAMING AND FINISHING
Figure 4, page 7, shows typical framing of this
replace. Figure 5, page 7, shows framing for
corner installation. All minimum clearances must
be met.
For overall unit dimensions, framing allowances
and vent collar locations, see Figure 6, page 7.
For available accessories for this replace, see
Accessories on page 39. If you are using a separate
combustible mantel piece, refer to Figures 7 and
8, page 8 for proper height and clearances. You
can install noncombustible mantels at any height
above the replace.
Note: Noncombustible mantels may discolor!
Figure 3 - Fireplace Bottom Dimensions
15"
36"
25"
www.desatech.com
118531-01A 7
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
36"
36
1
/
4
"
Figure 5 - Framing Clearances for Corner
Installation
PRE-INSTALLATION PREPARATION
Continued
14
3
/
4
"
2 - 2"x4" Vertical
Double Stud
14
3
/
4
"
21"
TO CENTER OF
TOP VENT
14
3
/
4
"
TO NAILING
FLANGES
56
3
/
4
"
12
1
/
4
"
TO
OPENING
28
5
/
8
"
These dimensions allow for 1" of
clearance at the sides and back of
replace. 0" clearance is also permitted
at all sides if framed.
Figure 6 - Unit Dimensions
7
5
/
8
"
TO CENTER OF
8" TOP VENT
14
3
/
4
"
TO NAILING
FLANGES
5/8"
36"
FACE DIM.
36
1
/
4
"
FACE DIM.
15
3
/
8
"
35
3
/
4
"
2 "
37"
TO NAILING
FLANGE
4
1
/
2
"
ELECTRICAL
INLET
8"
GAS SUPPLY
INLET
36
3
/
4
"
36
1
/
4
"
TO NAILING
FLANGE
2"
2"
38"
4"
TO
NAILING
FLANGE
WALL SWITCH
WIREWAY
WALL SWITCH
WIREWAY
2
1
/
2
"
www.desatech.com
118531-01A8
PRE-INSTALLATION
PREPARATION
Continued
Figure 8 - Side Clearances for Combustible Materials
33°
SAFE
ZONE
1
1
/
2
"
3
3
/
4
"
6"
5
1
/
2
"
12"
Perpendicular
Side Wall
Combustible
Material May
Be Used
Outer Surround
To Fireplace
Opening
C
B
A
D
E
F
G
3
2
1
4
5
6
7
Ref.
Mantel
Depth Ref.
Mantel from
Top of Louver
Opening
1 16" A 14"
2 14" A 12"
3 12" B 10"
4 10" C 8"
5 8" D 6"
6 4" F 4"
7 2" G 2"
Figure 7 - Clearances for Combustible Mantels
MANTEL CLEARANCES
Figure 7 shows projected mantel depths at various
heights above the top of the louver opening. Figure
8 shows the minimum allowable distances from
various mantel components in relation to the both
sides of the replace opening.
   
  -


   

    

used and the face are sealed with

www.desatech.com
118531-01A 9
Fixed
Closed
Openable
Fixed
Closed
Openable
V
V
V
V
V
V
V
V
X
X
V
X
G
G
J
F
B
B
K
N
H
I
A
N
E
L
D
B
M
A
C
B
V
V
A
G
G
B
TERMINATION CAP
AIR SUPPLY INLET
GAS METER RESTRICTED AREA
(TERMINATION PROHIBITED)
A = clearance above grade, veranda, porch, deck, or balcony
[*12 inches (30.5mc) minimum]
B = clearance to window or door that may be opened
[12 inches (30.5cm) minimum]
C = clearance to permanently closed window [minimum 12 inches
(30.5cm) recommended to prevent condensation on window]
D = vertical clearance to ventilated soffit located above the terminal
within a horizontal distance of 24 inches (61cm) from the
center-line of the terminal [18 inches (45.7cm) minimum]
E = clearance to unventilated soffit [12 inches (30.5cm) minimum]
F = clearance to outside corner (see below)
G = clearance to inside corner (see below)
H = *not to be installed above a meter/regulator assembly within
36 inches (91.4cm) horizontally from the center-line of the regulator
I = clearance to service regulator vent outlet [*72 inches (182.9cm)
minimum]
J = clearance to non-mechanical air supply inlet to building or the
combustion air inlet to any other fireplace [*12 inches (30.5cm)
minimum]
K = clearance to a mechanical air supply inlet [*72 inches (182.9cm)
minimum]
L = † clearance above paved side-walk or a paved driveway located on
public property [*84 inches (213.3cm) minimum]
M = clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ‡]
N = clearance above a roof shall extend a minimum of 24 inches (61cm)
above the highest point when it passes through the roof surface and
any other obstruction within a horizontal distance of 18 inches (45.7cm)
vent shall not terminate directly above a side-walk or paved driveway which is located between two
single family dwellings and serves both dwellings*
only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*
* as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.
Note: Local codes or regulations may require different clearances
A = 6" (15.2cm)
Inside Corner
V
B
E
V
B = 6" (15.2cm)
C = Maximum depth of 48" (121.9cm) for
recessed location
D = Minimum width for back wall of
recessed location -
Combustible - 38" (965mm)
Noncombustible - 24" (61cm)
E = Clearance from corner in
recessed location-
Combustible - 6" (15.2cm)
Noncombustible - 2" (5.1cm)
Outside Corner Recessed Location
G
H
G = 12" (30.5cm) minimum clearance
Balcony with No Side Wall
V
J
Combustible &
Noncombustible
H = 24" (61cm)
J = 20" (50.8cm)
Balcony with Perpendicular Side Wall
C
D
C
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Figure 9 - Minimum Clearances for Termination Cap
LOCATION OF TERMINATION CAP
www.desatech.com
118531-01A10
VENTING INSTALLATION
INSTRUCTIONS
NOTICE: Read these instruc-
-

These models are tested and approved for use
with DESA/Vexar (direct-vent) pipe components
and terminations.
The venting system must terminate on the outside of
the structure and can not be attached to a chimney
or ue system serving a separate solid fuel or gas
burning appliance. A direct-vent appliance must
have its own venting system. DO NOT common
vent this appliance.
This model is approved to be vented either
horizontally through an outside wall or vertically
through a roof or chase enclosure using the fol-
lowing:
When venting system terminates horizontally
on an outside wall, you may install a standoff
if the termination cap is to be installed directly
on a combustible nish such as vinyl, wood,
stucco, etc.
Never run the vent downward as this may
cause excessive temperatures which could
cause a re.
Vent pipe air space clearances to combustibles
are 1" on all sides except on the horizontal
sections, which requires 2" clearance from
the top of the pipe. Where the termination cap
penetrates a combustible wall, 1" air space
clearance is required.
Have replace and selected vent components on
hand to help determine the exact measurements
when elbowing or offsetting. Always use wall
restops when penetrating walls, ceilings or
attic spaces.
Install horizontal venting with a 1/4" rise for
every 12" of run toward the termination.
WARNING: Read all instruc-

  
Failure to do so could result in


IMPORTANT: Do not seal vent cap to pipe. Cap
must be removable for servicing.
NOTICE: Failure to follow these in-

NOTICE: Do not seal termination

   

INSTALLATION PRECAUTIONS
Wear gloves and safety glasses for protection
Use extreme caution when using ladders or
when on roof tops
Be aware of electrical wiring locations in walls
and ceilings
The following actions will void the warranty on
your venting system:
Installation of any damaged venting com-
ponent
Unauthorized modication of the venting system
(Do not cut or alter vent components)
Installation of any component part not manu-
factured or approved by DESA/Vexar
Installation other than as instructed by these
instructions






   


   







www.desatech.com
118531-01A 11
INSTALLATION PLANNING
There are two starter vent kits available for
either a horizontal or a vertical installation:
CHVK-58 Corner Horizontal Vent Kit - Intend-
ed for corner or ush installations with less than
24" of horizontal distance to the termination.
CVVK-58 - Ceiling Vertical Vent Kit - Intended
for a straight vertical installation through a ceil-
ing with less than 9' to a roof termination.
Horizontal Termination Installation
IMPORTANT: Horizontal square terminations
require only inner portion of wall restop.
1. Set the replace in its desired location and deter-
mine the route your horizontal venting will take.
Do not secure the replace until all venting has
been installed. Some installations require sliding
the replace in and out of position to make nal
venting connections. Figures 14 through 18 on
pages 13 and 14 show different congurations
for venting with horizontal termination that will
help you decide which application best suits your
installation. Check to see if wall studs or roof
rafters are in the path of your desired venting
route. If they are, you may want to adjust the
location of thereplace.
2. Direct vent pipe sections and components are
designed with special twist-lock connections.
 The female ends of the
pipes have locking lugs (indentations). These
lugs will slide straight into matching slots on
the male ends of adjacent pipes. Push pipe sec-
tions together and twist one section clockwise
approximately one-quarter turn until the sections
are fully locked (see Figure 10). Note: Horizon-
tal runs of vent must be supported every three
feet. Use wall straps for this purpose.
3. Any straight pipe section, a 45° or 90° elbow
can be used when rst connecting the venting
system to the replace. Elbows are designed
to twist-lock into any of four 90° positions to
direct the venting system to the desired loca-
tion. IMPORTANT: Do not attempt to alter
the conguration of the elbow by cutting,
twisting, bending, etc.
4. Assemble the desired combination of pipe and
elbows to the replace ue collar. If there are
long portions of venting run, pre-assembled
pipe sections may be installed as subassem-
blies for convenience.
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 10 - Vent Pipe Connections
Female
Locking Lugs
Male
Slots
Figure 11 - Vent Opening Requirements
Center of
Hole
5. Carefully determine the location where the vent
pipe assembly will penetrate the outside wall.
The center of the hole should line up with the
center-line of the horizontal vent pipe. Mark the
wall for a 10
3
/4" x 10
3
/4" square hole. Cut and
frame the square hole in the exterior wall where
the vent will be terminated (see Figure 11).
(Framing
Detail)
10
3
/
4
"
10
3
/
4
"
Inside Framing
10
3
/
4
"
8
1
/
2
"
Vent
O
pening
Combustible Wall
Vent Opening
Noncombustible Wall
www.desatech.com
118531-01A12
VENTING INSTALLATION
INSTRUCTIONS
Continued
WARNING: Do not recess
  

6.  For vinyl siding,
stucco or wood exteriors, a siding standoff
may be installed between the vent cap and
exterior wall. The siding standoff prevents
excessive heat from damaging the siding
materials. Siding material must be cut to
accommodate standoff. Bolt the vent cap
to the standoff. Apply nonhardening mastic
around outside edge of standoff. Position the
standoff/cap assembly in the center of the
10
3
/
4
" square hole and attach to exterior wall
with wood screws provided (see Figure 12).
The siding standoff must sit ush against the
exterior fascia material.
7.  Fit the outer
and inner wall restop into wall before connect-
ing horizontal run to vent cap (see Figure 13).
8. Carefully move replace, with vent assembly
attached, toward wall and insert vent pipe
into horizontal termination. The pipe overlap
should be a minimum of 1
1
/
4
".
9. Place replace into position and shim with
noncombustible material, if needed. Nail or
screw side anges to framing to secure unit in
place. IMPORTANT: Make sure replace is
level before securing. If replace is not level
it will not work properly.
Figure 12 - Installing Siding Standoff
(Combustible Exterior Wall)
Cut Siding Away
to Fit Standoff
Screws
Standoff
Vent
Cap
Apply Mastic
to All Four Sides
Figure 13 - Installing Outer Wall Firestop
(Combustible Exterior Wall)
Inner Wall
Firestop
Inner Wall
Firestop
Outer Wall
Firestop
NOTICE: Do not seal termination

   

WARNING: Never run vent
downward as this may cause
  

-
   


www.desatech.com
118531-01A 13
H
V
GROUND FLOOR INSTALLATION
Recommended CHVK-58 Corner Horizontal
Vent Kit:
Installation using cabinet surrounds
Through the wall using square termination
(up to 24" horizontal pipe)
Corner installation (Using one 6" vertical sec-
tion, one 90° elbow and a maximum of 24" of
horizontal pipe)
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 14 - Horizontal Termination
Conguration For Corner Installation
Using One 90° Elbow
Figure 15 - Horizontal Termination
Conguration with Vertical Rise and One
90° Elbow






51" 6" 26" Max.
57
1
/
4
" Min. 1' 30" Max.
69
1
/
4
" Min. 2' 74" Max.
81
1
/
2
" Min. 3' 98" Max.
94" Min. 4' 122" Max.
106" Min. 5' 146" Max.
159" Min. 9' 20' Max.
Wall
Firestop
Straight/
Adjustable
Pipe 24" Max.
Horizontal
Square
Termination
90°
Elbow
Corner Installation
 
51" Min. 32
1
/
2
" Max
90° Elbow
Wall
Firestop
Square
Termination
Not to Exceed
(H) Limits
As
Required
for (V),
See Chart
for Pipe
Section
Required

Figures 14 through 18 show different congura-
tions and alternatives for venting with horizontal
termination. Each figure includes a chart with
critical minimum and maximum dimensions which
MUST be met. IMPORTANT: Remember that a
horizontal run of venting must have a 1/4" rise for
every 12" of run toward the termination.
Figure 16 - Square Termination
Clearance at Ground Floor Installation
12"
Min.
www.desatech.com
118531-01A14
VENTING INSTALLATION INSTRUCTIONS
Continued
HORIZONTAL VENT INSTALLATIONS
USING MULTIPLE 90° ELBOWS
The following congurations show the minimum
vertical rise requirements for a horizontal system
using two 90° elbows.
Figure 17 - Horizontal Termination Conguration For Venting Using Two 90° Elbows



Horizontal (H
2
7' Min. 10' Max
8' Min. 12' Max
9' Min. 14' Max
10' Min. 16' Max
11' Min. 18' Max
13' Min. 20' Max
90°
Elbow
90°
Elbow
T
O
H
Figure 18 - Horizontal Termination Conguration for Venting Using Three 90° Elbows

 

Horizontal (H
2
5' Min. 2' Max. 6' Max
6' Min. 3' Max. 8' Max
7' Min. 4' Max. 10' Max
8' Min. 5' Max. 12' Max
12' Min. 8' Max. 20' Max
20' Min. 8' Max. 20' Max
90°
Elbow
90°
Elbow
90°
Elbow
www.desatech.com
118531-01A 15
VENTING INSTALLATION INSTRUCTIONS
Continued
INSTALLATION FOR VERTICAL
TERMINATION
Note: Vertical restrictor must be installed in all
vertical installations.
1. Determine the route your vertical venting
will take. If ceiling joists, roof rafters or other
framing will obstruct the venting system,
consider an offset (see Figure 19) to avoid cut-
ting load bearing members. Note: Pay special
attention to these installation instructions for
required clearances (air space) to combustibles
when passing through ceilings, walls, roofs,
enclosures, attic rafters, etc. Do not pack air
spaces with insulation. Also note maximum
vertical rise of the venting system and any
maximum horizontal offset limitations.
2. Set the replace in desired location. Drop a
plumb line down from the ceiling to the posi-
tion of the replace exit ue. Mark the center
point where the vent will penetrate the ceiling.
Drill a small locating hole at this point.
Drop a plumb line from the inside of the roof
to the locating hole in the ceiling. Mark the
center point where the vent will penetrate the
roof. Drill a small locating hole at this point.
Figure 19 - 45° and 30° Offset with Wall
Strap
Roof
Flashing
Wall
Strap
45°
Elbows
WS-58
Wall Strap
2 - 2 x 4
Vertical
Header
OSR58-30
30° Offset
Return
Horizontal
Frame Member

1. Cut a 10
3
/
4
" square hole in the ceiling using
the locating hole as a center point. The open-
ing should be framed to 10
3
/
4
" x 10
3
/
4
" inside
dimensions, as shown in Figure 11 on page
11 using framing lumber the same size as the
ceiling joists. If the area above the ceiling is
an insulated ceiling, you must use the restop
thimble and special restop included with the
kit to prevent insulation from contacting the
vent pipe (see Thimble Installation, page 16).
Otherwise, install restop below the framed
hole. The restop should be installed with no
less than three nails per side (see Figure 20).
2. Assemble the desired lengths of pipe and
elbows necessary to reach from the replace
ue up through the restop. Be sure all pipe
and elbow connections are fully twist-locked
(see Figure 10, page 11).
3. Cut a hole in the roof using the locating hole
as a center point. (Cover any exposed open
vent pipes before cutting hole in roof.) The
10
3
/
4
" x 10
3
/
4
" hole must be measured on
the horizontal; actual length may be larger
depending on the pitch of the roof. There
must be a 1" clearance from the vent pipe to
combustible materials. Frame the opening as
shown in Figure 11, page 11.
4. Connect a section of pipe and extend up
through the hole.
Note: If an offset is needed to avoid obstruc-
tions, you must support the vent pipe every 3
feet. Use wall straps for this purpose (see Fig-
ure 19). Whenever possible, use 45° elbows
instead of 90° elbows. The 45° elbow offers
less restriction to the ow of the ue gases
and intake air.
Figure 20 - Installing Firestop
If area above is a room, install restop
above framed hole.
If area above is an insulated area, install
restop below framed hole.
www.desatech.com
118531-01A16
5. Place the ashing over the pipe section(s)
extending through the roof. Secure the base of
the ashing to the roof and framing with roof-
ing nails. Be sure roong material overlaps the
top edge of the ashing as shown in Figure 19,
page 15. There must be a 1" clearance from
the vent pipe to combustible materials.
6.
Continue to add pipe sections until the height of
the vent cap meets the minimum building code
requirements described in Figure 9 on page 9.
Note: You must increase vent height for steep roof
pitches. Nearby trees, adjoining rooines, steep
pitched roofs and other similar factors may cause
poor draft or down-drafting in high winds. Increas-
ing the vent height may solve this problem.
7. Twist-lock the vent cap onto the last section
of vent pipe.
Note: If the vent pipe passes through any occupied
areas above the rst oor, including storage spaces
and closets, you must enclose pipe. You may frame
and sheetrock the enclosure with standard construc-
tion material. Make sure and meet the minimum
allowable clearances to combustibles. Do not ll
any of the required air spaces with insulation.

1. Plumb and locate knockout area for vent pipe.
2. Cut and frame ceiling joist to dimensions
shown in Figure 11, page 11.
3. Determine where restop plate should be at-
tached to thimble by test-tting thimble into
framing. Thimble should be at or above the
height of the insulation.
4. Attach thimble into restop plate using 4 hex
screws provided (see Figure 21).
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 22 - Vertical Venting
Conguration using Three 90° Elbows
(Vertical Round High Wind Termination)


Horizontal (H
1

Horizontal (H
2
8' Min. 5' Max
10' Min. 8' Max
12' Min. 11' Max
14' Min. 14' Max
16' Min. 17' Max
18' Min. 20' Max
40' Min. 20' Max
90° Elbow
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.
Framing
Top of
Thimble
Should
Measure
to Top of
Insullation
Hex Screw
to Attach
Firestop to
Thimble
Phillips Screws
to Attach
Firestop to
Framed Hole
Firestop
Figure 21 - Installing Thimble with
Firestop
5. Ret assembly into opening and attach to
framing with 8 phillips screws provided (see
Figure 20, page 15).
6. Thimble installation is ready to receive vent
pipe. Follow venting installation instructions.


Figures 22 through 25 show four different con-
gurations for vertical termination.
VERTICAL VENT INSTALLATIONS USING
MULTIPLE 90° ELBOWS
www.desatech.com
118531-01A 17
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 24 - Vertical Venting
Conguration Using Two 90° Elbows
(Vertical Round High Wind Termination)
Note: Vertical (V
1
)
+ Vertical (V
2
) =
40' Max.
Horizontal Above
14' Vertical =
20' Max.


Vertical
(V
1
Horizontal

8' Min. 9' Max
9' Min. 11' Max
10' Min. 13' Max
12' Min. 17' Max
14' Min. 20' Max

 
8' Min. 6' Max
9' Min. 8' Max
10' Min. 10' Max
12' Min. 14' Max
14' Min. 18' Max
40' Min. 20' Max
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.
90° Elbow
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination cap.
90°
Elbow
Figure 23 - Vertical Venting
Conguration Using Two 90° Elbows
(Vertical Round High Wind Termination)
Figure 25 - Vertical Venting
Conguration with No Horizontal Run
(Vertical Round High Wind Termi
nation)

V = 40' Max.
Note: Install a VR-58
vertical restrictor ring
into inner pipe section
prior to attaching vent
termination cap.
Note: Install an
OSR58-30 30°
offset return
with WS-58 wall
strap supports
as necessary
to maintain 1"
Clearance to all
horizontal wood
frame members.
WS-5 8

AND COMPONENTS

 
P58-6 6" Section Double Wall Pipe,
Galv.
P58-12 12" Section Double Wall Pipe,
Galv.
P58-24 24" Section Double Wall Pipe, Galv.
P58-36 36" Section Double Wall Pipe, Galv.
P58-48 48" Section Double Wall Pipe,
Galv.
PA58-712 Adjustable 7"-12" Section Double
Wall Pipe, Galv.
E58-45 45° Elbow, Galv.
E58-90 90° Elbow, Galv.
Note: Install a Firestop
Plate FP-58 or a Firestop
Thimble FTA-58 to
maintain cleaance to
combustible ceiling or
insulating materials.
www.desatech.com
118531-01A18
VENTING INSTALLATION
INSTRUCTIONS
Continued
 
CVVK-58 Ceiling Vertical Vent Kit
(Includes: 3 Offset Return, 7"-12"
Adjustable Pipe, Flue Restrictor,
Vertical High Wind Termination,
3' Pipe, 4' Pipe, Firestop Plate,
Firestop Thimble, Storm Collar,
Roof Flashing [0/12 - 6/12], 38
Screws)
CHVK-58 Corner Horizontal Vent Kit,
(Includes 90° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
6" Pipe, 18 Screws)
HHTK-58 High Wind Round Horizontal
Termination Kit (Includes Round
Termination, Wall Firestop, 45°
Elbow)
HHT-58 High Wind Round Horizontal
Termination Kit, Galv.
HTS-58 Horizontal Square Termination,
Galv. HTKS-58 Horizontal Square
Termination Kit (Includes: Square
Termination, Wall Firestop, 45°
Elbow)
VT-58 Vertical Round Termination, Galv.
SC-58 Storm Collar, Galv.
WF-58 Wall Firestop, Galv.
RF-58-6 Roof Flashing - 0 to 6/12 Pitch,
Galv.
RF-58-12 Roof Flashing - 6/12 to 12/12
Pitch, Galv.
VR-58 Vertical Restrictor, Galv.
S-58 Vinyl Siding Standoff, Galv.
WS-58 Wall Strap
CS-58 Cathedral Ceiling Support
FP-58 Firestop Plate
SF-58 Stucco Flashing -
For use with HTS-58
RF-58 Flat Roof Flashing
FIREPLACE
INSTALLATION
ELECTRICAL SUPPLY CONNECTION
CAUTION:
Disconnect the
    
-

WARNING:
 
-
   
      -
sence of local code, with the
current National Electric Code,
ANSI/NFPA 70, or the Canadian
Electric Code, CSA C22.1
A prewired junction box receptacle with strain
relief is provided on the right side of the cabinet
for hard wiring the unit to a 15 Amp, 120VAC,
60Hz grounded branch circuit. If the installation
demands that the electrical supply be connected
from the left side, the entire receptacle box can
be relocated to the left side by following these
instructions:
Note: If you do not need to relocate the junction
box, to connect the electric supply follow steps 8
through 11 only:
1. Remove 2 screws and outer cover with strain
relief bushing on right side of cabinet (see
Figure 26).
2. Remove inner retaining screw on junction box
mounting tab.
3. Slide junction box up until screw mounting
tab is lined up to notch in outer cabinet.
Figure 26 - Relocating Junction Box
Receptacle and Electrical Supply
Connection
J-Box Cover
with Strain
Relief
J-Box
Cover
Romex
Cable
J-Box with
Receptacle
J-Box Cover with
Strain Relief
Screw/Tab
Retainer
www.desatech.com
118531-01A 19
4. Swing the junction box out and slip retaining
ange out through the slot in outer cabinet.
5. Remove two screws and outer cover on the
left side of the outer cabinet.
6. Reinsert junction box retaining ange through
slot now on the left side and swing screw
mounting tab back through notch as before.
7. Slide the junction box down till mounting tab
holes line up and replace the inner retaining
screw.
8. With junction box cover removed, pull the end
of 3-wire Romex supply line through universal
strain relief bushing on cover (see Figure 26,
page 18).
9. Strip back the outer Romex to about 4" and
connect black, white and green wires accord-
ingly using 3 wire nut connectors.
10. Tuck tailing wires into junction box and
replace junction box cover using 2 remaining
screws.
11. Tighten down strain adjustment on universal
bushing until Romex sheathing is secured.
The electrical connection is now complete.

ACCESSORIES
   
    
-



WARNING: If there is a du-
   

     
    

-
     


Follow all instructions provided in the blower
accessory kit.
FIREPLACE
INSTALLATION
Continued
1. Attach power cord to blower motor by rmly
pushing the two female terminals at the end of
power cord onto the two spade terminals on
blower motor (see Figure 27).
2. Attach green ground wire from power cord
to blower housing using screw provided (see
Figure 27). Tighten screws securely.
3. Place blower against lower rear wall of the
rebox outer wrapper with exhaust port di-
rected upward. The blower will t inside the
back opening and be held in position against
the back wall by magnets (see Figure 27).
4.
Be certain that all wire terminals are securely at-
tached to terminals on blower motor and that the
screw retaining the green ground wire is tight.
5. Mount speed control box by placing plastic
control shaft through opening in switch
bracket (see Figure 28).
Blower Location
Side View
Figure 27 - Blower Model BK
Magnetic
Strips
Exhaust Port
Screw
Green
Ground
Wire
Spade
Terminals
Lower Firebox
Cavity
Figure 28 - Attaching Speed Control to
Firebox (Millivolt Models)
Speed Control
Control Shaft
Locknut
Control
Knob
Switch
Bracket
Blower
Plug-In
Duplex Outlet
(Located underneath
rebox oor against
lower right outside wall)
www.desatech.com
118531-01A20
6. While supporting speed control, secure control
shaft with lock nut by pushing and turning
lock nut with pliers clockwise until it is tight
against front panel. Place control knob pro-
vided on shaft.
7. Turn on power to duplex outlet if previously
turned off per the warningon page 19.
8. Plug in blower power cord.
a. If your rebox is installed as a free-
standing unit with an accessory mantel,
determine whether the power cord will exit
the left side or the right side of the rebox.
Route power cord through exit hole and
plug the power cord into a wall receptacle
near the rebox.
b. If your rebox installation is recessed
and/or prewired, plug the power cord into
the duplex outlet provided. Refer to your
rebox owner’s manual for instructions
on wiring the duplex outlet.
CAUTION: Never touch the

9. Check to make sure that the power cord is com-
pletely clear of the blower wheel and that there
are no other foreign objects in blower wheel.
Turn blower on and check for operation. Turn
blower off by turning knob fully counterclock-
wise before continuing.
10. Peel off the backing paper and stick the sup-
plied wiring diagram decal on the rebox bot-
tom approximately 12" in front of the blower
(see Figure 29).
V
ar
ia
bl
e
F
a
n
Sw
it
c
h
W
hi
t
e
W
hi
te
Bl
a
c
k
Gr
e
en
On
11
0
/
1
1
5
V
.
A
.
C
.
Bl
o
w
e
r
M
o
t
o
r
B
l
a
c
k
B
l
ac
k
Bl
a
ck
Of
f
Figure 29 - Location of Wiring Diagram
Decal (Model May Vary From Illustration)
Wiring Diagram Decal
6" in Front of Blower
FIREPLACE
INSTALLATION
Continued

Note: When installing the BKT thermostati-
cally-controlled blower, you must rst secure the
thermal switch bracket to the blower if it has not
already been factory installed.
1. Place the green ground wire with ring terminal
between the bottom hole on the thermal switch
bracket and the top ear hole on the blower as-
sembly. Insert the phillips screw into all three
pieces and tighten securely (see Figure 30).
2. Connect wire harness and power cord ter-
minals. Connect the blue jumper wire to the
blower motor terminal and the right side ter-
minal of the thermal switch. Connect the black
wire to the left side of the thermal switch and
the white wire to the other remaining blower
motor terminal.
Note: The power cord outer insulation sleeve may
have to be stripped slightly to allow enough wire
length to reach and make all connections. DO NOT
trim excessive length away. Just enable enough to
make all connections securely.
Thermodisc
Figure 30 - Blower Model BKT
Air Flow
Direction
Route BKT Blower
Through This Area
Magnets
Blower
Location
Side View Firebox Bottom
Black
Wire
Phillips
Screw
Blue Wire
Ring Terminal on
Green Wire
White Wire
Thermal
Switch
Thermal
Switch
Bracket
Power Cord
Air Flow
Direction
Magnetic
Strips
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Vexar CD36TN-M User manual

Category
Fireplaces
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI