  • Hello! I've analyzed the provided installation instructions for the Exit/Emergency Light. This document details how to safely install the unit, its self-diagnostic features, testing procedures and operation. The unit has automatic self-testing and provides a minimum of 90 minutes of emergency operation during power failure. It is designed with safety in mind. I'm ready to assist with any questions you have.
  • How long should the battery charge initially?
    What does a steady green LED indicate?
    What does a flashing green LED mean?
    What does a red blinking LED indicate?
NOTE: The maximum mounting height for this model is 8.5 feet.
  
  
Connection of remote emergency lights
(If Applicable)
Use Yellow, Blue & White wires for remote
fixtures. Route wires outside of fixture separately
or with AC supply wires. Make sure to keep all
wires out of the way of the EXIT legend so there
are no shadows.
STANDARD
REMOTE CAPABLE
WIRING DIAGRAMS
SELFDIAGNOSTICSTESTING:
Introduction
OncetheunitisproperlyinstalledaccordingtotheInstallationinstructionsheetandACpowerissupplied,theEXITwill
comeON.ThedualcolorLEDindicatorwillalsocomeON,automaticallyinitiatingtheselfdiagnostictestfunction.TheLED
indicatorpointsoutthecurrentunitstatus.ASTEADYGREENontheLEDindicatorindicatesanormalservice;BLINKING
GREENindicatesthattheunitisintestingmode;GREEN/REDFLASHINGindicatesthatthebatteryischarging;RED(STEADY
andBLINKING)wouldindicateafaultoraservicealert.Refertosection3FaultIndicationformoredetails.TheLED
indicatorwouldbeOFFwhentheunitisinEmergencymode.
1) SelfDiagnosticService
Theselfdiagnosticfunctionisfactorypresetwithoutanyfieldadjustment.Theautomaticselfdiagnosticfeatureservesthe
followingtests
a. Onlinerealtimemonitoringofbattery,lampsandLED(s):Identifiesbatterycharging,disconnectionandfailurealong
withLEDfailures.
b. Selftestinganda30seconddischargeonceevery30days(conformingtoNFPAcoderequirements),afterACpower
hasbeensuppliedforaminimumof24hours.
c. Selftestinganda30minutedischargeonceevery180days,afterACpowerhasbeensuppliedforaminimumof24
hours.
d. Selftestinganda90minutedischargeonceevery365days(conformingtoNFPAcoderequirements),afterACpower
hasbeensuppliedforaminimumof24hours.
2) FaultIndication
FaultDescriptionLEDIndication
BatteryDisconnectionSTEADYRed
BatteryRechargeFailure* FLASHINGRed
BatteryFailure** RedBLINKING‘2’times
LEDFailure RedBLINKING‘3’times
LAMPFailure RedBLINKING‘4’times
RemotelampFailure RedBLINKING‘5’times
* AbatteryrechargefailurewillcomeupifthebatteryisNOTabletorechargewithinthe24hrschargingtime
**AbatteryfailurewillcomeupifthebatteryisNOTabletooperatetheLEDstrip/lampsfortheperiodofadischargetest
3) ManualTesting
Thisunitalsoprovidesformanualtestingbypushingthetestswitchinaspecificpattern.Thedifferentpatternsandthe
resultingtestsarelistedinthetablebelow.
ACTIONREACTIONANDLEDINDICATION
Pushtestbuttononce(within2seconds)30secondtest;FLASHINGGreen
Pushtestbutton‘2’times(within2seconds)30minutetest;GreenBLINKING‘2’times
Pushtestbutton‘3’times(within2seconds)90minutetest;GreenBLINKING‘3’times
Push&Holdtestbutton(35seconds)SystemInterruption
Push&Holdtestbutton(morethan6seconds)SystemReset
4) Operation
Duringapowerfailure,theLEDstrip/lampswilltransferintoEmergencymodeandstayLITforaminimumof90minutes.
Totestthisunit,thebatteryneedstobechargedinitiallyfor24hoursbeforedepressingthetestswitch(todomanualtest).
Onpressingthetestswitch,theLEDstrip/lampswilltransferintoaSIMULATEDEmergencymodewiththeLEDindicator
FLASHING/BLINKINGGreen.TheLEDstrip/lampswillturnOFFafter30seconds/30minutes/90minutesrespectively.
/