Instructions
Flomatic 464 A-30 Autofil Valve to Flomatic Walrus Valve Kit
If you have any questions concerning this bulletin, please contact Manitowoc Beverage Equipment’s Technical Service Department at (800) 367-4233
5028132
REV2 04/24/07
NOTE: This kit will not work on valves ordered prior to
1/99. Use the date on the tag to verify the age.
1. Remove the cover from the valve.
2. Turn the syrup and water off to the valve at the back of
the valve with the two white shut-off plugs.
3. Activate the valve to release pressure, and to insure the
water and syrup are turned off to the valve.
4. Remove the electrical plug from the back of the coil.
5. Pull latch pin and remove valve from back block.
6. Remove the green wire between the lever retainer cap and
the green circuit board. Also remove the white wire between
the pin at the diffuser block and the green circuit board.
7. Remove the four screws that hold the solenoid coil in place,
and remove the coil from the valve body. (See Figure 1)
8. Pull the diffuser block off of the flow control base.
(See Figure 2)
9. Remove the two screws that hold the leaf style pallet retainer
spring in place. Then remove the spring. (See Figure 3)
10. Remove the retainer cap from the top of the metal lever.
Then remove the metal lever from the valve. (See Figure 4)
11. Hold the plastic retainer cap with fingers and with pliers pull
the green wire out of the lever retainer cap. (See Figure 5)
12. Locate the new lever supplied in the kit and attach the
lever to the pivot pin using the retainer cap. Route the
wires that are attached to the lever between the two ori-
fice caps. (See Figure 6)
Kit 5031018 Parts and Numbers
Solenoid, Auto Fill, Single .................................. 772-A36
Lever Sensor ....................................................... 516-10
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
FIGURE 5
FIGURE 6