10. Error List
Item
Code
TYPE
Error character string Error description
Remedy
1 0001 e BAD_SEQUENCE Communication sequence error
Wait until the response is received to send the
command.
2
0002
e
INVALID_COMMAND Command is invalid (undefined).
Send the correct command.
3 0003 e INVALID_MODE
The designated command cannot be
executed in this mode.
Switch the mode using the REMOTE or
LOCAL command.
4
0004
e
INVALID_FORMAT The command format is incorrect.
Send in the correct command format.
5
0005
e
NOT_POWER_SUPPLIED Power is not being supplied.
Use the POWER ON command to turn on the
power.
6 - i BUSY
Transition between states or processing is in
progress in the SX50.
Wait until the power supply state changes to
“ON”, “OFF”, or “PMM”.
7 000A e INVALID_PARAMETER
The parameter (type) is invalid (undefined).
This includes the case when the number of
parameters is incorrect.
Use the correct parameter(s).
8
000B
e
JOB_TIMEOUT SX50 internal processing has timed out. Resend the command.
9- w
USER_COMMAND_VERSION_IS_UPDA
TED
The user command version is being updated.
Use GET COMVER to obtain the latest user
command version.
10
F001
e
SYSTEM (UNKNOWN) An internal error occurred. Resend the command.
11 E0XX e COMMUNICATION_ERROR
A communication protocol violation occurred
in the projector.
Resend the command.
12 200X e INVALID_SOURCE (****)
This cannot be executed with the current input
source.
Change the input source.
The current input source is indicated in
parentheses.
13
2010
e
NO_SIGNAL There is no signal input.
Input the signal.
201X e INVALID_SIGNAL (****)
This cannot be executed with the current input
signal.
Change the input signal.
The current input signal is indicated in
parentheses.
14 -
i
BUSY (NOW_SETTING) Signal setting (detection) is in progress.
Wait until the processing is completed.
i
BUSY
(POWER_MANAGEMENT_READY)
Preparing to switch to power management
standby.
i
BUSY (INTERNAL_PROCESS) Heavy processing is in progress.
15
0801
0802
e
INVALID_VALUE
Numerical parameters are invalid or outside
the range.
Use the RANGE command to obtain the
parameter range, and then use a parameter
within the range.
16
1001 e TERMINAL_OUT
The input cannot be selected since the
terminal is set to output.
Use the TERMINAL command to set the
terminal to input, and then select the input
again.
1002 e NO_LOGO_CAPTURED
Processing cannot be executed since the user
image is not registered.
Register the user image.
1003
e
IP_NOT_AVAILABLE
IP conversion cannot be performed. Change to the correct input signal.
203X e INVALID_RESOLUTION (***) The input signal resolution is not correct.
Change to the correct resolution of the input
signal.
※
The error code is expressed as a four-digit hexadecimal character string. ‘X’ is a number from ‘0’ to ‘9’ or letter from ‘A’ to ‘F’.
※
Errors with the newer item numbers have higher priority. (When there is more than one error, the highest level error is returned. However, error priority is
the same within the same item number.)