ESAB EPP-200 Precision Plasmarc Cutting System User manual

Category
Welding System
Type
User manual

ESAB EPP-200 Precision Plasmarc Cutting System combines cutting-edge technology with user-friendly features for precise and efficient plasma cutting applications. With a cutting current range of 50 to 200 amperes, it delivers up to 32 kilowatts of cutting power, ensuring clean and accurate cuts on various materials.

ESAB EPP-200 Precision Plasmarc Cutting System combines cutting-edge technology with user-friendly features for precise and efficient plasma cutting applications. With a cutting current range of 50 to 200 amperes, it delivers up to 32 kilowatts of cutting power, ensuring clean and accurate cuts on various materials.

EPP-200
Precision Plasmarc Cutting System
0558007005 10 / 2007
Instruction Manual
2
This equipment will perform in conformity with the description thereof contained in this manual and accompa-
nying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instruc-
tions provided. This equipment must be checked periodically. Malfunctioning or poorly maintained equipment
should not be used. Parts that are broken, missing, worn, distorted or contaminated should be replaced imme-
diately. Should such repair or replacement become necessary, the manufacturer recommends that a telephone
or written request for service advice be made to the Authorized Distributor from whom it was purchased.
This equipment or any of its parts should not be altered without the prior written approval of the manufacturer.
The user of this equipment shall have the sole responsibility for any malfunction which results from improper
use, faulty maintenance, damage, improper repair or alteration by anyone other than the manufacturer or a ser-
vice facility designated by the manufacturer.
BE SURE THIS INFORMATION REACHES THE OPERATOR.
YOU CAN GET EXTRA COPIES THROUGH YOUR SUPPLIER.
These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the
principles of operation and safe practices for arc welding and cutting equipment, we urge
you to read our booklet, “Precautions and Safe Practices for Arc Welding, Cutting, and
Gouging,” Form 52-529. Do NOT permit untrained persons to install, operate, or maintain
this equipment. Do NOT attempt to install or operate this equipment until you have read
and fully understand these instructions. If you do not fully understand these instructions,
contact your supplier for further information. Be sure to read the Safety Precautions be-
fore installing or operating this equipment.
CAUTION
USER RESPONSIBILITY
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
PROTECT YOURSELF AND OTHERS!
3
SECTION TITLE PAGE
SECTION 1 SAFETY .................................................................................................................................... 5
SECTION 2 DESCRIPTION .......................................................................................................................................................... 7
SECTION 3 INSTALLATION ......................................................................................................................................................13
SECTION 4 OPERATION ............................................................................................................................................................21
TABLE OF CONTENTS
DECLARATION OF CONFORMITY
According to
The Low Voltage Directive 2006/95/EC of 12 December 2006, entering into force 16 January 2007
The EMC Directive 2004/108/EC
FÖRSÄKRAN OM ÖVERENSSTÄMMELSE
Lågspänningsdirektivet 2006/95/EG från 12 december 2006, ikrafsat 16 januari 2007
EMC-Direktivet 2004/108/EG
Type of equipment Materialslag
Plasma Cutting Console
Brand name or trade mark Fabrikatnamn eller varumärke
ESAB
Type designation etc. Typbeteckning etc.
EPP-200, (0558004315)
Manufacturer or his authorised representative established within the EEA
Name, address, telephone No, telefax No: Tillverkarens namn, adress, telefon, telefax:
ESAB AB
Esabvägen, SE-695 81 Laxå, Sweden
Phone: +46 586 81000, Fax: +46 584 411 924
The following harmonised standard in force within the EEA has been used in the design:
Följande harmoniserande standarder har använts i konstruktionen:
EN 60974-1, Arc welding equipment – Part 1: Welding power sources
EN 60974-10, Arc welding equipment – Part 10: Electromagnetic compatibility (EMC) requirements
Additional information: / Tilläggsinformation: Restrictive use, Class A equipment, intended for use in locations other than
residential
By signing this document, the undersigned declares as manufacturer, or the manufacturer’s authorised
representative established within the EEA, that the equipment in question complies with the safety requirements
stated above.
Genom att underteckna detta dokument försäkrar undertecknad såsom tillverkare, eller tillverkarens representant inom
EES, att angiven materiel uppfyller säkerhetskraven angivna ovan.
Date / Datum
Laxå 2009-02-18
Signature / Underskrift Position / Befattning
Global Director
Equipment and Automation
Kent Eimbrodt
Clarification
5
SECTION 1 SAFETY PRECAUTIONS
1.0 Safety Precautions
Users of ESAB welding and plasma cutting equipment have the ultimate responsibility for ensuring that anyone
who works on or near the equipment observes all the relevant safety precautions. Safety precautions must meet
the requirements that apply to this type of welding or plasma cutting equipment. The following recommendations
should be observed in addition to the standard regulations that apply to the workplace.
All work must be carried out by trained personnel well acquainted with the operation of the welding or plasma
cutting equipment. Incorrect operation of the equipment may lead to hazardous situations which can result in
injury to the operator and damage to the equipment.
1. Anyone who uses welding or plasma cutting equipment must be familiar with:
- its operation
- location of emergency stops
- its function
- relevant safety precautions
- welding and / or plasma cutting
2. The operator must ensure that:
- no unauthorized person stationed within the working area of the equipment when it is started up.
- no one is unprotected when the arc is struck.
3. The workplace must:
- be suitable for the purpose
- be free from drafts
4. Personal safety equipment:
- Always wear recommended personal safety equipment, such as safety glasses, ame proof
clothing, safety gloves.
- Do not wear loose tting items, such as scarves, bracelets, rings, etc., which could become
trapped or cause burns.
5. General precautions:
- Make sure the return cable is connected securely.
- Work on high voltage equipment may only be carried out by a qualied electrician.
- Appropriate re extinquishing equipment must be clearly marked and close at hand.
- Lubrication and maintenance must not be carried out on the equipment during operation.
6
SECTION 1 SAFETY PRECAUTIONS
WELDING AND PLASMA CUTTING CAN BE INJURIOUS TO YOURSELF AND
OTHERS. TAKE PRECAUTIONS WHEN WELDING OR CUTTING. ASK FOR
YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE BASED ON
MANUFACTURERS’ HAZARD DATA.
ELECTRIC SHOCK - Can kill.
- Install and earth (ground) the welding or plasma cutting unit in accordance with applicable standards.
- Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
- Insulate yourself from earth and the workpiece.
- Ensure your working stance is safe.
FUMES AND GASES - Can be dangerous to health.
- Keep your head out of the fumes.
- Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone
and the general area.
ARC RAYS - Can injure eyes and burn skin.
- Protect your eyes and body. Use the correct welding / plasma cutting screen and lter lens and wear
protective clothing.
- Protect bystanders with suitable screens or curtains.
FIRE HAZARD
- Sparks (spatter) can cause re. Make sure therefore that there are no inammable materials nearby.
NOISE - Excessive noise can damage hearing.
- Protect your ears. Use earmus or other hearing protection.
- Warn bystanders of the risk.
MALFUNCTION - Call for expert assistance in the event of malfunction.
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
PROTECT YOURSELF AND OTHERS!
WARNING
7
SECTION 2 DESCRIPTION
The EPP-200 Power Console is designed for mechanized plasma
applications. It can be used with other ESAB products such as the
PT-24 and PT-600 torches, an optional plumbing box and a remote
set-up pendant.
• 50to200Amperescuttingcurrentrange
• Forcedaircooled
• SolidstateDCpower
• Integralwatercooler
• Inputvoltageprotection
• Localorremotefrontpanelcontrol
• Thermalswitchprotectionformaintransformerand
power semiconductor components
• LEDstatustroubleshooting
2.1 Introduction
2.2 General Specications
EPP-200 Power Console (0558004315):
OUTPUT (100% duty cycle)
Voltage ......................................................................................................... 160VDC
Current range DC .................................................................................50A to 200A
Power ................................................................................................. 8000 W to 32000 W
Open Circuit Voltage (OCV) .................................................................. 325VDC
INPUT
Voltage (3-phase) .............................................................. 200/230/380/415/460/575 Volts
Current (3-phase) ...............................................................115/100/60/55/50/40 Amperes
Frequency ....................................................................................................50/60Hz
KVA .................................................................................................................39.8 kW
Power .............................................................................................................37.8 kW
PowerFactor ...................................................................................................95%
InputFuse .................................................................................. See Section 3, Installation
8
Electric Shock Can Kill!
Use of torches not designed for this console could result in a haz-
ardous electric shock.
Use only torches designed for the EPP-200 Console.
WARNING
2.3 Dimensions and Weight
44 in. (1100mm)
42in. (1050mm)
22in. (550mm)
Weight = 725 lbs. (330 kg)
SECTION 2 DESCRIPTION
9
2.4 EPP-200 Options and Accessories
Options
5 ft. (1.5m)
10 ft. (3.0m)
20 ft. (6.1m)
25 ft. (7.6m)
30 ft. (9.1m)
40 ft. (12.2m)
50 ft. (15.2m)
75 ft. (22.9m)
100 ft. (30.5m)
125 ft. (38.1m)
150 ft. (45.7m)
* Cooling Water Hoses (2)
Console to Plumbing Box
Control Cable
Plumbing Box to Console
Pilot Arc Lead
Plumbing Box to Console
Power Lead
Console to Plumbing Box
0558003979
0558003980
0558003981
33132
0558003982
0558003983
33133 (4495019)
33134 (4495020)
33135 (4495021)
33136 (4495022)
0558003984
N / A
N / A
N / A
0558004651
N / A
N / A
0558004652
0558004653
0558004654
0558003978
0558004655
0558003985
0558003986
0558003987
33303
0558003988
0558003989
33304 (4495034)
33305 (4495035)
33306 (4495036)
33307 (4495037)
0558003990
0558003991
0558003992
0558003993
22001 (4495038)
0558003994
0558003995
22002 (4495039)
22003 (4495040)
22004 (4495041)
22005 (4495042)
0558003996
SECTION 2 DESCRIPTION
NOTE:
Part Numbers in parenthesis apply to "CE"/European units only.
* Use with one adaptor fitting (41V12) included with unit.
10
2.5 Gas Hoses
Gas Type 25 ft. 50 ft. 75 ft. 100 ft. 125 ft.
(7.6m) (15.2m) (22.8m) (30.4m) (38.1m)
Nitrogen (clear) 33122 33123 33124 33125 33126
Oxygen (clear - USA) 33117 33118 33119 33120 33121
Oxygen (blue - Euro) 0558002973 0558002974 0558002975 0558002976 0558002977
Argon/Hydrogen (H-35) (1) 33122* 33123* 33124* 33125* 33126*
Air (clear - USA) 33122** 33123** 33124** 33125** 33126**
Air (black - Euro) (2) 0558002978** 0558002979** 0558002980** 0558002981** 0558002982**
Note: * = Requires adapter P/N 19X54 (4494001) (order separately)
** = Requires adapter P/N 74S76 (0558004057) (order separately)
2.6 Gas Regulators
Station Regulator Cylinder Regulator
Nitrogen .....................................................19155 ............................................998343
Oxygen .......................................................19151 .............................................998336
Argon/Hydrogen (H-35) .......................19153 .............................................998341
Air .................................................................30338 (4492008) .......................N/A
A separate start gas regulator is always required:
• Forairplasmauseairstartgas.
• Foroxygenornitrogenusenitrogenstartgas.
• ForH-35(argon/hydrogen)H-35ornitrogenstartgas.
A total of 3 regulators will be required (plasma, start and
secondary).
When using a plumbing box:
• Gashosesfromsupplycylindersgodirectlytothe
plumbing box.
• Consolegasmanifoldisnotused.
NOTICE
NOTICE
SECTION 2 DESCRIPTION
NOTE:
Part Numbers in parenthesis apply to "CE"/European units only.
11
2.7 Basic Packages
The EPP-200 system is available as a pre-engineered package or can
be ordered as individual parts as listed.
Basic Packages include:
• EPP-200Console
• PlasmaTorch
• Appropriateregulatorsforthegasesindicated
• Gashosesfromregulatorstoconsole
• Torchcoolant
Torch Coolant (25%) – 1 gallon (3.8 L) P/N 0558004297
25% PG coolant improves electrode life in applications using oxygen or
aircutgasbutonlyprovidesfreezeprotectiondownto13°F(-10.6°C)
TorchCoolant(50%)–1gallon(3.8L)P/N156F05(7810012)
50%EGcoolantprovidesfreezeprotectiondownto-40°F
(-40.0° C)
SECTION 2 DESCRIPTION
NOTE:
Part Numbers in parenthesis apply to "CE"/European units only.
12
SECTION 2 DESCRIPTION
13
SECTION 3 INSTALLATION
3.1 General
Failure To Follow Instructions Could Lead To Death,
Injury Or Damaged Property
Followtheseinstructionstopreventinjuryorpropertydamage.
You must comply with local, state and national electrical and safety
codes.
WARNING
Use Lifting Eye When Hoisting From Overhead
Use safe practices when transporting with overhead method.
Unit weighs over 700 lbs (318 kg). Use approved straps or cables
in good condition.
CAUTION
3.2 Unpacking
• Inspectfortransitdamageimmediatelyuponreceipt.
• Removeallcomponentsfromshippingcontainerand
check for loose parts in container.
• Inspectlouversforairobstructions.
14
WARNING
CAUTION
CAUTION
Do Not Restrict Air Flow
Restricting intake air with any type of lter on or around the Plasma
console will result in overheating and may void the warranty.
3.3 Placement
• Aminimumof2ft.(0.61m)clearanceforcoolingairow.
• Planfortoppanelandsidepanelshavingtoberemoved
for maintenance, cleaning and inspection.
• LocatetheEPP-200relativelyclosetoaproperlyfused
electrical power supply.
• Keepareabeneathpowersourceclearforcoolingair
ow.
• Environmentshouldberelativelyfreeofdust,fumesand
excessive heat. These factors will aect cooling
eciency.
Conductive Dust And Dirt Inside Power Source May
Cause Arc Flash Over
Equipment damage may occur. Electrical shorting may occur if
dust is allowed to buildup inside power source. See maintenance
section.
Electric Shock Can Kill!
Provide maximum protection against electrical shock.
Before any connections are made inside the machine, open the
line wall disconnect switch to turn power o.
3.4 Input Connections to Console
Plasma
Console
SECTION 3 INSTALLATION
15
NOTICE
3.4.1 Primary Power Specications
EPP-200 is a 3-phase unit. Input power must be provided from a line
(wall) disconnect switch that contains fuses or circuit breakers in
accordance to local or state regulations.
Recommended input conductor and line fuse sizes:
Dedicated power line may be necessary.
EPP-200 is equipped with line voltage compensation but to avoid
impaired performance due to an overloaded circuit, a dedicated
power line may be required.
*SizesperNationalElectricalCodefora75°C(165°F)ratedcopper
conductors@40°C(104°F)ambient.Notmorethanfourconductors
in raceway or cable. Local codes should be followed if they specify sizes
other than those listed above. Input current values given in this table
are at maximum output power (32kW) 200 amps at 160VDC.
Rated Load Input and Ground
conductor*
CU/AWG
Time delay
Fusesize
(amperes)
Volts Amperes
200/208 115 1 150
230 100 2 125
380 60 4 80
415 55 6 70
460 50 6 70
575 40 8 60
SECTION 3 INSTALLATION
16
3.4.2 Primary Power Hookup Procedure
The following procedure explains the proper installation steps for
connecting primary electrical power to the plasma console.
NOTE: Safety codes specify the power ground wire be the last
connection to break should the cable be pulled out of the unit.
When preparing the cable for connection, make the ground wire
6 inches (152mm) longer than the three pr primary wires.
1. Ensure input power cable is disconnected from all electrical
sources.
2. Remove right side panel (as viewed from front of console).
3. Route input power cable through the strain relief located at the rear
panel.
4. Pull input power cable through the strain relief to allow cable wires
sucient length to connect to main contactor. Tighten strain relief to
ensure input power cable is secured.
5. Connect input power cable ground wire to the ground lug provided
above TB2 (7 position terminal block).
6. Connect three power leads of input power cable to terminals located
atop the main contactor. Secure the leads by tightening each screw.
7. Connect jumper power cables from bottom of the main contactor
to proper input voltage marked on auto transformer. Unit is factory set
for 575V as shown at the left.
8. Connect jumper on TB2 to proper input voltage. This 7 position
terminal block jumper is factory set to 575V.
Input Power Jumper Connection
Ensure each input power jumper cable is connected to correct input
voltage on autotransformer and on TB2.
Factorywiredfor575Volts
CAUTION
Input Power Cable
Strain Relief
Main
Contactor
Ground
Connection
7 Position
Terminal
Block
Auto
Transformer
Factorywired
for 575 volts
SECTION 3 INSTALLATION
17
9. Connect input conductors to line (wall) disconnect.
10. Replace side panel. Replace only if all connections have made.
Output connections require this panel to be removed.
11. Connect the other end of work cable to workpiece or cutting table.
Connection must be made to a clean, exposed metal surface, free of
paint, rust, mill scale, etc.
Electric Current Is Hazardous.
It is important to have a good earth ground connected to the
workpiece or cutting table.
WARNING
Work ground to work piece
Work ground to cutting table
SECTION 3 INSTALLATION
18
3.5 Connecting Plasma Torches to EPP-200 Console and Options
3.5.1 EPP-200 Output Cables, Hoses and Adapters (customer supplied)
EPP-200:
Lengths vary depending on system.
• CoolantReturn
• CoolantSupply
• PilotArcCable
• ElectrodeCable
• ShieldGas(directlytothePlumbingBox)
• StartGas(directlytothePlumbingBox)
• CutGas(directlytothePlumbingBox)
• WorkCable
• PendantCable(ifpendantoptionisordered)
See Description, Section 2 for part numbers.
A remote SETUP Panel option is available on Avenger 1 and larger ESAB
cut cutting machines. This panel operates the same as the pendant.
Refer to your machine manual for replacement parts.
SECTION 3 INSTALLATION
19
Commercial Antifreeze Will Cause Torch To
Malfunction.
Use special torch coolant.
Do to high electrical conductivity, DO NOT use tap water or
commercial automotive type antifreeze for torch cooling. A specially
formulated torch coolant is REQUIRED. This coolant also protects
fromfreezingto-34°C(-29°F).
Operating the unit without coolant will cause permanent damage
to the coolant pump.
Check coolant level frequently.
Remove coolant ll cap at front console and ll coolant tank with 4
gallons (15 liters) of plasma torch coolant.
• Donotllaboveindicatedmaximumlevel.
• Reinstallcap.
CAUTION
Electric Current Is Hazardous.
It is important to have a good earth ground connected to the
workpiece or cutting table.
WARNING
3.6 Coolant Installation
CoolantFillCap
SECTION 3 INSTALLATION
20
SECTION 3 INSTALLATION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

ESAB EPP-200 Precision Plasmarc Cutting System User manual

Category
Welding System
Type
User manual

ESAB EPP-200 Precision Plasmarc Cutting System combines cutting-edge technology with user-friendly features for precise and efficient plasma cutting applications. With a cutting current range of 50 to 200 amperes, it delivers up to 32 kilowatts of cutting power, ensuring clean and accurate cuts on various materials.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI