Amperes AM6000 User manual

Category
Audio amplifiers
Type
User manual
amperes electronics
www.ampereselectronics.com
INSTRUCTION MANUAL
Thank you for selecting and trusting another product from Amperes Electronics.
AM6000 monitor panel does not only provide audio monitoring of your pa power amplifiers of up to 6 units
connected to it with its high fidelity 1 watt speaker, but it offers 7 level LED monitoring as well as continuous
audio presence signal indicators. The LED level meter proves to be useful in the amplifier output calibration of
your installation.
With AM6000, we offer a product of easy installation, with the affordable price of a quality equipment. Though
it is rather simple in the installation works, a brief read through the manual is recommended.
AM6000
amplifier monitor panel
the emerging preference
amperes
AM 6000
4
32
1
OFF
MAX
MONITOR VOLUME
5
3 4
1
2
6
AMPLIFIER SELECT
AMPLIFIER OUTPUT LEVEL METER ( dB )
AMPLIFIER OUTPUT SIGNAL
1 2 4 53 6
-18-24 -21 -15 -9 -6-12 -3 0
PAGE 2
Parts Identification and Function
Thank you for selecting another product from Amperes Electronics and we truly believe that by
incorporating AM6000 into your system, you would find them operating more than satisfactory in what
you had expected
1
2
3
5
4
6
7
1. SPEAKER
Audio monitoring of selected amplifier output is monitored from this 1 watt speaker
2. MONITOR VOLUME KNOB
The loudness of speaker volume is controlled from this 5 steps attenuator.
3. AMPLIFIER SELECT
This knob is used to select the amplifier intended to be monitored.
4. LED BAR METER
The output level of the amplifier selected is monitored from the 9 segment LED bar meter. The meter
indicates the actual output level of amplifier regardless of the position of the monitor volume. The
reference of the reading shall be 0dB equivalent to 100V line output.
5. AMPLIFIER OUTPUT SIGNAL LED
These LED shall provide signal presence of all the amplifiers connected to the monitoring panel.
6. DC SUPPLY TERMINAL
AM6000 shall require 24V DC supply for its operation. Kindly use recommended power supply
(Amperes PS301S).
7. AMPLIFIER INPUT TERMINALS
Polarity of amplifiers to be connected to AM6000 shall be observed as wrong connection shall cause
your power pack faulty.
amperes
AM 6000
4
32
1
OFF
MAX
MONITOR VOLUME
5
3 4
1
2
6
AMPLIFIER SELECT
AMPLIFIER OUTPUT LEVEL METER ( dB )
AMPLIFIER OUTPUT SIGNAL
1 2 4 53 6
-18-24 -21 -15 -9 -6-12 -3 0
CAUTION : PLEASE OBSERVE POLARITY
AMPLIFIER INPUTS
AMP 4
100V
DC SUPPLY
24V,1A
+
AMP 2
AMP 3
AMP 1
COM
100V
-
100V
COM
COM
100V
AMP 5 AMP 6
COM
COM
100V
100V
COM
AMP 6
AMP IN - FROM AMPLIFIER OUTPUT
PLEASE OBSERVE LINE POLARITY
TO ZONE SELECTOR / SPK
AMP 1
AMP IN 6
AMP IN 1
AM 6000
AMPLIFIER MONITOR PANEL WIRING DIAGRAM
AM 6000
Connection Schematic
Technical Specifications
NOTE :
Amperes Electronics Sdn Bhd has the policy of improving or reviewing its products in design, performance as well as quality from time to time. It is
therefore, Amperes Electronics has the right to change the above specifications without prior notice. The specification change shall cover the physical
appearance, features as well as components used. However, amperes Electronics shall maintain at all times that the products manufactured are of
highest quality.
PAGE 3
Operating Voltage
Wattage
Amplifier inputs
Monitoring mode
Cabling connection
Colour
Dimensions
Weight
: 24V DC
: 50 mW nominal
: 6 uts with 70 / 100V line outputs.
: Audio - 1w speaker with 5 preset level.
: Visual - 9 segment LED meter
: All inputs continuous LED signal indicator.
: 2.5 mm using barrier connectors
: Black, powder epoxy finishing
: 482 (W) x 88 (H) x 90 (D) mm
: 2.2 kgs
100V
AMP. 3
CAUTION : PLEASE OBSERVE POLARITY
AMPLIFIER INPUTS
-
+
DC SUPPLY : 24V, 1A
COM
AMP. 2
100V100V
COM
AMP. 1
Another Quality Product From
AMP. IN - FROM AMPLIFIER OUTPUT
PLEASE OBSERVE LINE POLARITY
AMPLIFIER MONITOR PANEL WIRING DIAGRAM
AMP.6
AMP.1
100V
AMP. 6
COM
100V 100V
COM
AMP. 5AMP. 4
COM COM
TO ZONE SELECTOR / SPK
AM600
AMP.IN 6
AMP.IN 1
SER.NO :
A
MP
.INPUT
S
IGNAL
P.AMP #6
P.AMP #1
100V
COM
COM
100V
PLEASE OBSERVE CONNECTION
POLARITY
DC24V REG.SUPPLY
(AMPERES PS301S)
AMPERES AM600 SHALL OPERATE
WITH OR WITHOUT 24V DC SUPPLY
ONLY LED BAR METER IS NOT AVAILABLE
WITHOUT 24V DC SUPPLY
AMPERES AM6000
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes
Electronics Service Centres may be asked for by the purchaser or send directly to Amperes
Electronics Sdn Bhd or its authorized master distributor, Amperes Global Marketing. This warranty is
not valid if repairs are performed by unauthorized personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of
transportation as well as removal and installation of the product from the main system are for the
account of the purchaser. This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as
using the product with power supply voltage other than shown on the product, or any other power
supply source / adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods. lightning and every cause
not directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period
out of use of the unit; moreover the warranty does not cover any damages which may be caused to
people and things when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are
made on this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 12
months from the date of purchase or for a longer period in countries where this is stated by a
national law. In this case, the extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under
warranty if the design changes or improvements are made.
WARRANTY CONDITIONS
PAGE 4
DISCLAIMER
Information contained in this manual is subject to change without prior notice and does not
represent a commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be
liable for any loss or damages whatsoever arising from the use of information or any error contained
in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES
ELECTRONICS SDN BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in
conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages
caused by service, maintenance or repair by unauthorized personnel, or by use other than that
intended by the manufacturer.
by AMP
ER
ES
ELEC
TRONI
C
S
ww
w
.
am
pe
resel
e
ct
roni
cs.
c
om
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Amperes AM6000 User manual

Category
Audio amplifiers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI