Amperes AS4000 User manual

Type
User manual
by amperes electronics
www.ampereselectronics.com
VER1 /0202
INSTRUCTION MANUAL
AS 4000
AMPLIFIER LINE SURVEILLANCE MODULE
CONT N/O
FAILURE DETECTED
amperes electronics
CONT N/C
CONT COM
SIG OUT -
SIG OUT +
GND
SIG IN +
SIG IN -
Ensure correct power polarity
Use recommended power supply only
with PA amplifier of 70/100V line only
This appliance is intended to be used
amplifier line surveillance module
AS4000
WARNING :
PILOT SIGNAL TRANSMIT
DC24V +
DC24V -
AMP +
AMP -
POWER AMPLIFIER
PROFESSIONAL PA SYSTEM
PROTECTION
DCOUTPUT
ACINPUT
POWER
24V DC SUPPLY
AUDIO IN (FROM MIXER)
PT/AUDIO OUT
70/100 V
NC/NO CONTACT
AMPERES
AS4000
POWER AMPLIFIER
AMPERES AX700
AUTO-CHANGEOVER
TO SPEAKER
ZONE SELECTOR
1 6
DUPLICATE THE CONFIGURATION
FOR MORE THAN 1 AMPLIFIER
CASCADE AX700 IF MORE THAN 6 AMPLIFIERS
COM
20KHz
INTERNAL
OSCILLATOR
AUDIO IN
(FR.MIXER)
PT + AUDIO
OUT (BALANCE)
INTERNAL
MIXER
70/100 V LINE
AMP.OUT
N/O & N/C
DRY CONTACT
COMMON
PILOT TONE
SENSING
RELAY /
CONTACT
24V DC REG.
PS INPUT
PAGE 2
Block Diagram / Schematic
The block diagram shown is for the installer
to have a better understanding on how the
unit works when interfacing it with other
brands of PA equipment.
It is however not recommended that the
internal circuitry of the unit be modified
without prior consultation with the
manufacturer.
Thank you
for selecting another product from Amperes Electronics and we truly believe that by
incorporating AS4000 into your system, you would find them more than satisfactory in what you expected.
Introduction .....
Installing Amperes AS4000 together with Amperes AX700 ( Automatic Amplifier Changeover Unit )
shall establish an automatic amplifier line surveillance setup in your public address system.
AS4000 shall be connected to each power amplifier and shall monitor the line condition
continuously by injecting an inaudible frequency to the pack at repeated intervals. Failure to sense
the monitor signal in return shall confirm the failure of the power amplifier or if when the line out is
shorted. Upon detection of the failure, a dry contact shall be established to provide a signal to AX700,
which would then perform a standby changeover to the duty amplifier concerned.
AS4000 is designed with fine circuitry, is an ideal choice for an automatic surveillance installation
setup, made in modular form which proved to be cost effective.
application schematic
block diagram
Connecting The Unit
Technical Specifications
NOTE :
Amperes Electronics Sdn Bhd has the policy of improving or reviewing its products in design, performance as well as quality from time to time. It is
therefore, Amperes Electronics has the right to change the above specifications without prior notice.The specification change shall cover the physical
appearance, features as well as components used. However, amperes Electronics shall maintain at all times that the products manufactured are of
highest quality.
PAGE 3
Operating Voltage
Wattage
Input impedance
Output impedance
Max audio input
Max signal output
Transmit interval
Detection delay
Failure recovery time
Dry contact rating
Frequency response
Line Detection
Connection
Indications
Weight
Dimensions
: 24V
: 200 mW nominal
: 10 K Ohm balanced
: 600 Ohm balanced
: 0.75 V
: 1.20 V
: 10 seconds
: 38 seconds
: Up to 22 secs ( max for idle amp startup)
: 3 A DC
: 20 - 20 kHz
: 70/100 V line with sensitivity adjustment
: Audio signal input
Audio and pilot tone signal output
Amplifier 70/100V line input
NC or NO dry contact
: LED for Failure Detected and Pilot Tone tx
: 350 gms
: 120 (w) x 36 (l) x 28 (h) mm
CONNECTOR ASSIGNMENTS
RLY NC
RLY COM
SIG OUT -
SIG OUT +
GND
SIG IN +
SIG IN -
DC24V +
DC24V -
AMP +
AMP -
RLY NO
24V DC
(PS301S)
AC INPUT
DCOUTP UT
PROTECTION
PROFESSIONAL PA SYSTEM
POWER AMPLIFIER
POWER
POWER AMPLIFIER
70/100V
COLD
CH 1
POWER
PROFESSIONAL AUDIO MIXER
CH 2 CH 3 CH 4 CH 5 CH8CH 7CH 6 MASTER
- VE (COLD)
+VE (HOT)
SCREEN
-VE (COLD)
+VE (HOT)
SCREEN
TRIGGER INPUT TO
RESPECTIVE AMPLIFIER-AS4000 ASSIGNMENT
FOR APPLICATION OF AS4000 TRIGGER CONTACT
OTHER THAN AX700 ( eg.ALARM, MIMIC PANEL, ETC )
PLEASE REFER TO THE INSTALLATION GUIDE OF
THE RESPECTVIE EQUIPMENT
BALANCE AMPLIFIER
INPUT SIGNAL
BALANCE MIXER OUTPUT
FROM TOP VIEW
COM
REPEAT TO OTHER AS4000
NOTE :
LOOP "COM" FROM AX700
ONLY TO RESPECTIVE
"RLY COM" OF AS4000
CONNECTED TO THE
SAME AX700
AMPERES AX700
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes
Electronics Service Centres may be asked for by the purchaser or send directly to Amperes
Electronics Sdn Bhd 70 Jalan Industri 3, Tmn Industri Pusat Bandar Puchong, 47100 Puchong or its
authorized master distributor, Amperes Global Marketing. This warranty is not valid if repairs are
performed by unauthorized personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of
transportation as well as removal and installation of the product from the main system are for the
account of the purchaser.This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as
using the product with power supply voltage other than shown on the product, or any other power
supply source / adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods. lightning and every cause
not directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period
out of use of the unit; moreover the warranty does not cover any damages which may be caused to
people and things when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are
made on this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 12
months from the date of purchase or for a longer period in countries where this is stated by a
national law. In this case, the extension is valid only in the country where the product is purchased.
Amperes Elec
tronics Sdn Bhd is not obliged to modify
previously manufactured products under
warranty if the design changes or improvements are made.
Warranty Conditions
PAGE 4
Disclaimer
Information contained in this manual is subject to change without prior notice and does not
represent a commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be
liable for any loss or damages whatsoever arising from the use of information or any error contained
in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES
ELECTRONICS SDN BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in
conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages
caused by service, maintenance or repair by unauthorized personnel, or by use other than that
intended by the manufacturer.
by AMPERES ELECTRONICS
www.ampereselectronics.com
ISO 9001: 2008
Design & Manufacture of Public Address Equipment and Systems
Certicate No. 16895 / A / 0001 / UK / En
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Amperes AS4000 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI