Version
This document applies to
NS3550-8T-2S.
FCC compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference,
and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
FCC compliance
Class A:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to pa
rt 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not i
nstalled and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correc
t the interference at his own expense.
Canada
This Class A digital apparatus complies with CAN ICES
-003 (A)/NMB-3 (A).
Cet appareil numérique de la classe A est conforme à la norme CAN ICES
-003
(A)/NMB
-3 (A).
ACMA compliance
Notice!
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
Certification
EU directives
This product and
- if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the
EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU.
2012/19
/EU (WEEE directive): Products marked with this symbol cannot be disposed of
as unsorted m
unicipal waste in the European Union. For proper recycling, return this
product to your local supplier upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more information see:
www.recyclethis.info.
Product
warnings and
disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN
EXPERIENCED SECURITY PROFESSIONAL. UTC FIRE & SECURITY CANNOT
PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”
OR “AUTHORIZED
RESELLER”
, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL
SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information, please
check www.firesecurityproducts.com
/policy/product-warning/ or scan the following code:
Contact information
and
manuals
For contact information
and manuals, go to: www.interlogix.com or
www.firesecurityproducts.com
NS3550-8T-2S Industrial Managed Switch User Manual 1
Content
Important information 3
Chapter 1 Introduction 4
Package contents 4
Product description 5
Product features 6
Product specifications 9
Chapter 2 Installation 13
Hardware description 13
Installing the industrial managed switch 18
Cabling 21
Chapter 3 Switch management 27
Requirements 27
Management access overview 27
Remote Telnet 28
Web management 29
SNMP-based network management 30
Chapter 4 Web management 31
Main web page 33
System 34
Simple Network Management Protocol (SNMP) 60
Port management 70
Link aggregation 77
VLAN 84
Spanning Tree Protocol (STP) 110
Multicast 128
Quality of Service (QoS) 151
Access Control Lists (ACL) 174
Authentication 188
Security 222
MAC address table 238
LLDP 244
Network diagnostics 258
Loop protection 263
RMON 265
Ring 274
Chapter 5 Command line interface 288
Accessing the CLI 288
Telnet login 288
2 NS3550-8T-2S Industrial Managed Switch User Manual
Chapter 6 Command line mode 289
System Command 290
IP Command 296
Port Management Command 302
MAC Address Table Command 306
VLAN Configuration Command 309
Private VLAN Configuration Command 316
Security Command 318
Spanning Tree Protocol Command 364
Link Aggregation Command 373
Link Aggregation Control Protocol Command 375
LLDP Command 378
LLDP MED Command 382
EEE Command 386
Thermal Command 387
Ethernet Virtual Connections Command 388
Ethernet Protection Switching Command 392
Maintainence entity End Point Command 393
Quality of Service Command 400
Mirror Command 413
Configuration Command 415
Firmware Command 415
UPnP Command 416
MVR Command 417
Voice VLAN Command 421
Ethernet Ring Protection Switching Command 425
Loop Protect Command 430
IPMC Command 432
VLAN Control List Command 440
SMTP Command 443
Chapter 7 Switch operation 446
Address table 446
Learning 446
Forwarding and filtering 446
Store-and-forward 446
Auto-negotiation 447
Chapter 8 Troubleshooting 448
Appendix A Networking connection 450
Glossary 452
NS3550-8T-2S Industrial Managed Switch User Manual 3
Important information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will UTCFS be liable
for any lost profits or business opportunities, loss of use, business interruption, loss of
data, or any other indirect, special, incidental, or consequential damages under any
theory of liability, whether based in contract, tort, negligence, product liability, or
otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages the preceding limitation may not apply to you.
In any event the total liability of UTCFS shall not exceed the purchase price of the
product. The foregoing limitation will apply to the maximum extent permitted by
applicable law, regardless of whether UTCFS has been advised of the possibility of
such damages and regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the
authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure
the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted
results. The advisory messages used in this document are shown and described below.
WARNING: Warning messages advise you of hazards that could result in injury or loss
of life. They tell you which actions to take or to avoid in order to prevent the injury or
loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell you
which actions to take or to avoid in order to prevent damage.
Note: Note messages advise you of the possible loss of time or effort. They describe
how to avoid the loss. Notes are also used to point out important information that you
should read.
4 NS3550-8T-2S Industrial Managed Switch User Manual
Chapter 1
Introduction
The description of the IFS NS3550-8T-2S model is as follows:
Industrial L2+ 8-port 10/100/1000T
+ 2-port 100/1000X managed switch
Unless specified, the term industrial managed switchmentioned in this user manual
refers to the NS3550-8T-2S.
Package contents
Open the box of the industrial managed switch and carefully unpack it. The box should
contain the following items:
The industrial managed switch × 1
Quick installation guide × 1
CD with user manual × 1
DIN rail kit x 1
Wall mounting kit x 1
SFP dust-proof cap x 2
RJ45 dust-proof cap x 8
If any of these are missing or damaged, contact your dealer immediately. If possible,
retain the carton including the original packing materials for repacking the product in
case there is a need to return it to us for repair.
Chapter 1: Introduction
NS3550-8T-2S Industrial Managed Switch User Manual 5
Product description
The industrial managed switch is specially designed to build a full Gigabit backbone to
transmit reliable and high-speed data in demanding heavy industrial environments and
forward data to a remote network through fiber optic cabling. It comes with an IP30
rugged case and redundant power system. Besides support for 20 Gbps switch fabric
to handle extremely large amounts of video, voice, and important data in a secure
topology, the industrial managed switch provides user-friendly, advanced IPv6/ IPv4
management interfaces and abundant L2/L4 switching functions. It is the best
investment for expanding industrial business or upgrading its network infrastructure..
IPv6/IPv4 full-function secure switch for building automation networking
The industrial managed switch is the ideal solution to fulfilling the demand of IPv6
management gigabit Ethernet switches, especially in the industrial-hardened
environment. It supports both IPv4 and IPv6 protocols, advanced Layer 2 to Layer 4
data switching and redundancy, QoS traffic control, network access control and
authentication, and secure management features to protect customer’s industrial and
building automation network connectivity with reliable switching recovery capability that
is suitable for implementing fault tolerant and mesh network architectures.
Redundant ring, fast recovery for critical network applications
The industrial managed switch supports redundant ring technology and features strong,
rapid self-recovery capability to prevent interruptions and external intrusions. It
incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching)
technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input
system into the customer’s industrial automation network to enhance system reliability
and uptime in harsh factory environments. In a certain simple ring network, the
recovery time of data link can be as fast as 20 ms.
Environmentally hardened design
With its IP30 aluminum case, the industrial managed switch provides a high level of
immunity against electromagnetic interference and heavy electrical surges which are
usually found on plant floors or in curb-side traffic control cabinets. It also possesses an
Chapter 1: Introduction
6 NS3550-8T-2S Industrial Managed Switch User Manual
integrated power supply source with a wide range of voltages (12 to 48 VDC or 24
VAC) for worldwide high availability applications requiring dual or backup power inputs.
Being able to operate under the temperature range from -40 to 75°C, the industrial
managed switch can be placed in almost any difficult environment.
Flexible and extendable solution
The industrial managed switch features 100BASE-FX and 1000BASE-SX/LX SFP
(Small Form-factor Pluggable) fiber-optic modules, meaning the administrator now can
flexibly choose the suitable SFP transceiver according to the transmission distance or
the transmission speed required to extend the network efficiently. The industrial
managed switch supports the SFP-DDM (Digital Diagnostic Monitor) function that can
easily monitor real-time parameters of the SFP for the network administrator such as
optical output power, optical input power, temperature, laser bias current, and
transceiver supply voltage
Product features
Physical port
Eight 10/100/1000BASE-T gigabit RJ45 copper ports.
Two 100/1000BASE-X mini-GBIC/SFP slots, SFP type auto detection.
Industrial case and installation
IP30 aluminum case
DIN-rail and wall-mount design
Redundant power design
12 to 48 VDC, redundant power with polarity reverse protect function
AC 24 V power adapter acceptable
Supports EFT protection 6000 VDC for power line
Supports Ethernet ESD protection for 6000 VDC
-40 to 75°C operating temperature
Chapter 1: Introduction
NS3550-8T-2S Industrial Managed Switch User Manual 7
Layer 2 features
Prevents packet loss with back pressure (Half-Duplex) and IEEE 802.3x PAUSE
frame flow control (Full-Duplex).
High performance of Store-and-Forward architecture and runt/CRC filtering
eliminates erroneous packets to optimize the network bandwidth.
Storm control support:
Multicast / Unknown-Unicast
Supports VLAN
IEEE 802.1Q tagged VLAN
Up to 255 VLANs groups out of 4094 VLAN IDs
Provider bridging (VLAN Q-in-Q) support (IEEE 802.1ad)
Private VLAN Edge (PVE)
Protocol-based VLAN
MAC-based VLAN
Voice VLAN
Supports STP
STP, IEEE 802.1D Spanning Tree Protocol
RSTP, IEEE 802.1w Rapid Spanning Tree Protocol
MSTP, IEEE 802.1s Multiple Spanning Tree Protocol, spanning tree by VLAN
BPDU Guard
Supports link aggregation
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
Cisco ether-channel (static trunk)
Maximum five trunk groups, up to 10 ports per trunk group
Up to 20 Gbps bandwidth (Duplex Mode)
Provides port mirror (many-to-1)
Port mirroring to monitor the incoming or outgoing traffic on a particular port
Supports Ethernet Ring Protection Switching (ERPS)
Quality of Service
Ingress shaper and egress rate limit per port bandwidth control
Eight priority queues on all switch ports
Traffic classification:
- IEEE 802.1p CoS
Chapter 1: Introduction
8 NS3550-8T-2S Industrial Managed Switch User Manual
- TOS / DSCP / IP Precedence of IPv4/IPv6 packets
- IP TCP/UDP port number
- Typical network application
Strict priority and Weighted Round Robin (WRR) CoS policies
Supports QoS and In/Out bandwidth control on each port
Traffic-policing policies on the switch port
DSCP remarking
Multicast
Supports IGMP snooping v1, v2, and v3
Supports MLD snooping v1 and v2
Querier mode support
IGMP snooping port filtering
MLD snooping port filtering
Multicast VLAN Registration (MVR) support
Security
Authentication
IEEE 802.1x Port-Based / MAC-Based network access authentication
Built-in RADIUS client to co-operate with the RADIUS servers
TACACS+ login users access authentication
RADIUS / TACACS+ users access authentication
Access Control List (ACL)
IPv4 / IPv6 IP-based ACL
MAC-based ACL
Source MAC / IP address binding
DHCP snooping to filter distrusted DHCP messages
Dynamic ARP inspection discards ARP packets with invalid MAC addresses to IP
address binding.
IP source guard prevents IP spoofing attacks.
Auto DoS rule to defend against DoS attacks.
IP address access management to prevent unauthorized intruders.
Management
Switch management interfaces:
Remote Telnet management
Chapter 1: Introduction
NS3550-8T-2S Industrial Managed Switch User Manual 9
Web switch management
SNMP v1 and v2c switch management
SSH / SSL and SNMP v3 secure access
IPv6 IP address/NTP/DNS management
Built-in Trivial File Transfer Protocol (TFTP) client
System maintenance
- Firmware upload/download via HTTP / TFTP
- Dual images
- Reset button for system reboot or reset to factory default
Four RMON groups (history, statistics, alarms, and events)
IPv6 IP address / NTP / DNS management and ICMPv6
BOOTP and DHCP for IP address assignment
DHCP relay
DHCP Option 82
User privilege levels control
NTP (Network Time Protocol)
Link Layer Discovery Protocol (LLDP) and LLDP-MED
Network diagnostic
Cable diagnostic technology provides the mechanism to detect and report
potential cabling issues
Reset button for system reboot or reset to factory default
Product specifications
Model Name
NS3550
-8T-2S
Hardware Specifications
Copper
Ports
Eight 10/100/1000BASE
-T RJ45 Auto-MDI/MDI-X ports
SFP
+ Slots
Two 100/1000BASE
-SX/LX/BX SFP interfaces (Port-9 and Port-10)
Compatible with 100Base
-FX SFP
Switch Architecture
Store
-and-Forward
Switch
Fabric
20
Gbps / non-blocking
Throughput
14.8
Mpps
Address Table
8
K entries, automatic source address learning and aging
Share
d Data Buffer
512 KB
Chapter 1: Introduction
10 NS3550-8T-2S Industrial Managed Switch User Manual
Flow Control
IEEE 802.3x
pause frame for full-duplex
Back pressure for
half-duplex
Jumbo Frame
9
K bytes
Reset Button
< 5 seconds: System reboot
>
5 seconds: Factory Default
Enclosure
IP30 aluminum case
Installation
DIN rail kit and wall
-mount kit
Alarm
One relay output for power failure. Alarm relay current carry ability:
1A @ 24
VDC
LED
System:
Power 1 (Green)
Power 2 (Green)
Fault Alarm (Green)
Ring (Green)
Ring Owner (Green)
Per 10/100/1000T RJ45 Ports:
1000 (Orange)
LNK/ACT (Green)
Per SFP
Interface:
1000 (Orange)
LNK/ACT (Green)
Dimensions
1
87.8 x 135 x 56 mm
Weight
720
g
Power Requirement
D
C 12 to 48 V, 24 VAC power adapter
Power
Consumption
10 W
/ 34 BTU (full loading)
ESD Protection
6K VDC
EFT Protection
6K VDC
Layer 2 Functions
Basic Management
Interfaces
Web browser;
Remote Telnet, SNMP v1, v2c
Secure Management
Interfaces
SSH, SSL, SNMPv3
Port
Configuration
Po
rt disable / enable
Auto
-negotiation 10/100/1000Mbps full and half duplex mode selection.
Flow
control disable/enable
Power saving mode control
Port Status
Display each port’s
speed duplex mode, link status, flow control status, auto-
negotiation status, trunk
status.
Port Mirroring
TX / RX / both
Many
-to-1 monitor
Chapter 1: Introduction
NS3550-8T-2S Industrial Managed Switch User Manual 11
VLAN
802.1Q tagged
-based VLAN, up to 255 VLAN groups
Q
-in-Q tunneling
Private VLAN
MAC
-based VLAN
Protocol
-based VLAN
Voice VLAN
MVR (Multicast VLAN Registration)
U
p to 255 VLAN groups, out of 4095 VLAN ID
Link Aggregation
IEEE 802.3ad LACP
/static trunk
Five groups with 10
ports per trunk
QoS
Traffic classification based,
strict priority and WRR
8
-level priority for switching
Port number
802.1p priority
802.1Q VLAN tag
DSCP/ToS field in IP packet
IGMP Snooping
IGMP (v1/v2
/v3) snooping, up to 255 multicast groups
IGMP
querier mode support
MLD Snooping
MLD (v1/v2)
snooping, up to 255 multicast groups
MLD
querier mode support
Access Control List
IP
-based ACL / MAC-based ACL
Up to
256 entries
Bandwidth Control
Per port bandwidth control
Ingress: 500 Kbps~1000 Mbps
Egress: 500 Kbps~1000 Mbps
Standards Conformance
Regulation Compliance
FCC Part 15 Class A, CE
Stability Testing
IEC60068
-2-32 (Free fall)
IEC60068
-2-27 (Shock)
IEC60068
-2-6 (Vibration)
Standards Compliance
IEEE
802.3 10Base-T
IEEE
802.3u 100Base-TX / 100Base-FX
IEEE
802.3z Gigabit SX/LX
IEE
E 802.3ab Gigabit 1000T
IEEE
802.3x Flow Control and Back pressure
IEEE
802.3ad Port trunk with LACP
IEEE
802.1D Spanning Tree Protocol
IEEE
802.1w Rapid Spanning Tree Protocol
IEEE 802.1s Multiple
Spanning Tree Protocol
IEEE
802.1p Class of service
IEEE
802.1Q VLAN Tagging
IEEE 802.1x Port
Authentication Network Control
IEEE 802.1ab LLDP
Chapter 1: Introduction
12 NS3550-8T-2S Industrial Managed Switch User Manual
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 2068 HTTP
RFC 1112 IGMP version 1
RFC 2236 IGMP version 2
RFC 3376 IGMP version 3
RFC
2710 MLD version 1
FRC 3810 MLD version 2
SNMP MIBs
RFC
-1213 MIB-II
IF
-MIB
RFC
-1493 Bridge MIB
RFC
-1643 Ethernet MIB
RFC
-2863 Interface MIB
RFC
-2665 Ether-Like MIB
RFC
-2819 RMON MIB (Group 1, 2, 3 and 9)
RFC
-2737 Entity MIB
RFC
-2618 RADIUS Client MIB
RFC
-2933 IGMP-STD-MIB
RFC3411
SNMP-Frameworks-MIB
IEEE
802.1X PAE
LLDP
MAU
-MIB
Environment
Operating
Temperature:
-40 to 75°C
Relative Humidity:
5 to 95% (non-condensing)
Storage
Temperature:
-40 to 85°C
Relative Humidity:
5 to 95% (non-condensing)
13 NS3550-8T-2S Industrial Managed Switch User Manual
Chapter 2
Installation
This section describes the hardware features of the industrial managed switch. For
easier management and control of the industrial managed switch, familiarize yourself
with its display indicators and ports. Front panel illustrations in this chapter display the
unit LED indicators. Please read this chapter completely before connecting any network
device to the industrial managed switch,.
Hardware description
The industrial managed switch provides three different running speeds 10Mbps,
100Mbps, and 1000Mbps, and automatically distinguishes the speed of the incoming
connection.
Chapter 2: Installation
14 NS3550-8T-2S Industrial Managed Switch User Manual
Physical dimensions
Dimensions (W x D x H): 87.8 x 135 x 56 mm
Chapter 2: Installation
NS3550-8T-2S Industrial Managed Switch User Manual 15
Front panel
Reset button
Located on the upper left side of the front panel, the reset button is designed to reboot
the industrial managed switch without turning the power off and on. The following is the
summary table of the reset button functions:
Chapter 2: Installation
16 NS3550-8T-2S Industrial Managed Switch User Manual
Function
Reboots the industrial managed switch
Resets the industrial managed switch to factory default
configuration. The switch then reboots and loads the
default settings as shown below:
Default Username: admin
Default Password: admin
Default IP address: 192.168.0.100
Subnet mask: 255.255.255.0
Default Gateway: 192.168.0.254
LED indicators
The front panel LEDs indicate port link status, data activity, and system power.
System
LED
Color Function
P1
Green Lit: indicates that the power input 1 has power.
P2
Green Lit: indicates that the power input 2 has power.
F
ault Green Lit: indicates that either power 1 or power 2 has no power.
Ring
Green Lit: indicates that the ERPS ring has been sucessfully created.
R.O.
Green Lit: indicates that the switch has enabled ring owner.
Per 10/100/1000Base-T port
LED Color Function
LNK/ACT Green Lit: indicates the port has successfully connected to the network.
Blinking: indicates that the switch is actively sending or receiving
data over that port.
1000 Orange Lit: indicates the port has successfully connected to the network at
1000 Mbps.
Blinking: indicates that the switch is actively sending or receiving
data over that port.
Per SFP interface
LED Color Function
LNK/ACT
Green Lit: indicates the port has successfully connected to the network.
Blinking: indicates that the switch is actively sending or receiving
data over that port.
1000 Orange Lit: indicates the port has successfully connected to the network at
1000 Mbps.
Blinking: indicates that the switch is actively sending or receiving
data over that port.
Chapter 2: Installation
NS3550-8T-2S Industrial Managed Switch User Manual 17
Wiring the power input
The rear panel of the industrial managed switch contains a DC inlet power socket and
one terminal block connector with six contacts.
1. Insert positive/negative DC power wires into contacts 1 and 2 for DC Power 1, or 5
and 6 for DC Power 2.
2. Tighten the wire-clamp screws to prevent the wires from loosening.
1
2
3
4
5
6
DC 1
DC 2
Note:
1. The wire gauge for the terminal block should be in the range of 12 to 24 AWG.
2. When performing any of the procedures such as inserting the wires or tightening the
wire-clamp screws, make sure the power is OFF to avoid electrical shock.
Wiring the fault alarm contact
The fault alarm contacts are in the middle (3 & 4) of the terminal block connector as the
picture shows below. Inserting the wires, the industrial managed switch detects the fault
status of the power failure, or port link failure. The following illustration shows an
application example for wiring the fault alarm contacts. Wires are inserted into the fault
alarm contacts.
Chapter 2: Installation
18 NS3550-8T-2S Industrial Managed Switch User Manual
Note:
1. The wire gauge for the terminal block should be in the range of 12 to 24 AWG.
2. When performing any of the procedures such as inserting the wires or tightening the
wire-clamp screws, make sure the power is OFF to avoid electrical shock.
Installing the industrial managed switch
This section describes how to install and make connections to the industrial managed
switch. Read the following topics and perform the procedures in the order presented.
Installation steps
To install the industrial managed switch on a desktop or shelf:
1. Unpack the industrial managed switch
2. Ensure that the DIN-Rail is screwed onto the industrial managed switch. If the DIN-
rail is not screwed on, please refer to the DIN-rail mounting section for DIN-rail
installation. To wall-mount the industrial managed switch, please refer to the wall
mount plate mounting section for wall-mount plate installation.
3. Power on the industrial managed switch. please refer to the wiring the power inputs
section for information about how to wire the power. The power LED on the
industrial managed switch illuminates. Refer to the LED Indicators section for
information about LED functionality.
4. Prepare the twisted-pair, straight-through Category 5 cable for Ethernet connection.
5. Insert one side of RJ45 cable (category 5) into the industrial managed switch
Ethernet port (RJ45 port) and the other side to the network device’s Ethernet (RJ45)
port (e.g., switch PC or server). The UTP port (RJ45) LED on the industrial
managed switch illuminates when the cable is connected with the network device.
Refer to the LED Indicators section for information about LED functionality.
Note: Ensure that the connected network devices support MDI/MDI-X. If they do not
support this, use the crossover Category 5 cable.
6. When all connections are set and all LED lights appear normal, the installation is
complete..
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418
  • Page 419 419
  • Page 420 420
  • Page 421 421
  • Page 422 422
  • Page 423 423
  • Page 424 424
  • Page 425 425
  • Page 426 426
  • Page 427 427
  • Page 428 428
  • Page 429 429
  • Page 430 430
  • Page 431 431
  • Page 432 432
  • Page 433 433
  • Page 434 434
  • Page 435 435
  • Page 436 436
  • Page 437 437
  • Page 438 438
  • Page 439 439
  • Page 440 440
  • Page 441 441
  • Page 442 442
  • Page 443 443
  • Page 444 444
  • Page 445 445
  • Page 446 446
  • Page 447 447
  • Page 448 448
  • Page 449 449
  • Page 450 450
  • Page 451 451
  • Page 452 452
  • Page 453 453
  • Page 454 454
  • Page 455 455
  • Page 456 456
  • Page 457 457
  • Page 458 458
  • Page 459 459
  • Page 460 460
  • Page 461 461
  • Page 462 462
  • Page 463 463
  • Page 464 464
  • Page 465 465
  • Page 466 466
  • Page 467 467
  • Page 468 468
  • Page 469 469
  • Page 470 470

Interlogix Industrial Gigabit Managed Switches (NS3550-8T-2S) User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI