Interlogix Industrial Gigabit Managed Switches (NS3552-8P-2S and NS3550-2T-8S) User manual

  • Hello! I am an AI chatbot trained to assist you with the Interlogix Industrial Gigabit Managed Switches (NS3552-8P-2S and NS3550-2T-8S) User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
NS3552-8P-2S and
NS3550
-2T-8S User Manual
P/N 1072689-EN • REV D • ISS 25JAN19
Copyright
©
2019 United Technologies Corporation.
Interlogix is part of UTC
Climate, Controls & Security, a unit of United Technologies
Corporation
. All rights reserved.
Trademarks and patents
Trade names used in this document may be trademarks or registered trademarks of the
manufacturers or vendors of the respective products.
Manufacturer
Interlogix
2955 Red Hill Avenue, Costa Mesa, CA 92626
-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Version
This document applies to
NS3552-8P-2S and NS3550-2T-8S.
FCC compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause
harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
FCC compliance
Class A:
This equipment has been tested and found to comply with the limits for a Class
A digital d
evice, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency
energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will
be required to correct the interference at his own expense.
Canada
This Class A digital apparatus complies with CAN ICES
-003 (A)/NMB-3 (A).
Cet appareil numérique de la classe A est conforme à la norme CAN ICES
-003
(A)/NMB
-3 (A).
ACMA compliance
Notic
e! This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
Certification
EU directives
This product and
- if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the
EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU.
2012/19
/EU (WEEE directive): Products marked with this symbol cannot be disposed of
as unsorted municipal waste in the European Union. For proper recycling, return this
product to your local supplier upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more information see:
www
.recyclethis.info.
Product warnings and
disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN
EXPERIENCED SECURITY PROFESSIONAL. UTC FIRE & SECURITY CANNOT
PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS
PRODUCTS,
INCLUDING ANY “AUTHORIZED DEALER” OR “AUTHORIZED
RESELLER”
, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL
SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information, please
check www.firesecurityproduct
s.com/policy/product-warning/ or scan the following code:
Contact information
and
manuals
For contact information
and manuals, go to: www.interlogix.com or
www.firesecurityproducts.com
NS3552-8P-2S and NS3550-2T-8S User Manual 1
Content
Important information 3
Chapter 1 Introduction 4
Package contents 4
Product description 5
Product features 10
Product specifications 14
Chapter 2 Installation 19
Hardware description 19
Installing the industrial managed switch 26
Cabling 29
Chapter 3 Switch management 35
Requirements 35
Management access overview 35
CLI mode management 36
Web management 38
SNMP-based network management 38
Chapter 4 Web configuration 40
Main web page 42
System 43
Simple Network Management Protocol (SNMP) 71
Port management 81
Link aggregation 88
VLAN 96
Spanning Tree Protocol (STP) 121
Multicast 139
Quality of Service (QoS) 162
Access Control Lists (ACL) 185
Authentication 199
Security 233
MAC address table 249
LLDP 255
Network diagnostics 268
Power over Ethernet (PoE) 272
Loop protection 284
RMON 286
Ring 295
Chapter 5 Command line interface 309
Accessing the CLI 309
Telnet login 309
2 NS3552-8P-2S and NS3550-2T-8S User Manual
Chapter 6 Command line mode 310
System Command 311
IP Command 317
Port Management Command 323
MAC Address Table Command 327
VLAN Configuration Command 330
Private VLAN Configuration Command 337
Security Command 339
Spanning Tree Protocol Command 385
Link Aggregation Command 394
Link Aggregation Control Protocol Command 396
LLDP Command 399
LLDP MED Command 403
EEE Command 407
Thermal Command 408
PoE Command (NS3552-8P-2S only) 409
Ethernet Virtual Connections Command 410
Ethernet Protection Switching Command 415
Maintainence entity End Point Command 416
Quality of Service Command 423
Mirror Command 436
Configuration Command 437
Firmware Command 438
UPnP Command 438
MVR Command 440
Voice VLAN Command 443
Ethernet Ring Protection Switching Command 448
Loop Protect Command 452
IPMC Command 454
VLAN Control List Command 462
SMTP Command 466
DIDO Command 468
Show Command 472
Chapter 7 Switch operation 477
Address table 477
Learning 477
Forwarding and filtering 477
Store-and-forward 477
Auto-negotiation 478
Chapter 8 Troubleshooting 479
Appendix A Networking connection 481
Glossary 483
NS3552-8P-2S and NS3550-2T-8S User Manual 3
Important information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will UTCFS be liable
for any lost profits or business opportunities, loss of use, business interruption, loss of
data, or any other indirect, special, incidental, or consequential damages under any
theory of liability, whether based in contract, tort, negligence, product liability, or
otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages the preceding limitation may not apply to you.
In any event the total liability of UTCFS shall not exceed the purchase price of the
product. The foregoing limitation will apply to the maximum extent permitted by
applicable law, regardless of whether UTCFS has been advised of the possibility of
such damages and regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the
authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure
the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted
results. The advisory messages used in this document are shown and described below.
WARNING: Warning messages advise you of hazards that could result in injury or loss
of life. They tell you which actions to take or to avoid in order to prevent the injury or
loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell you
which actions to take or to avoid in order to prevent damage.
Note: Note messages advise you of the possible loss of time or effort. They describe
how to avoid the loss. Notes are also used to point out important information that you
should read.
4 NS3552-8P-2S and NS3550-2T-8S User Manual
Chapter 1
Introduction
The description of the IFS NS3552-8P-2S model is as follows:
Industrial L2+ 8-port 10/100/1000T 802.3at PoE
+ 2-port 100/1000X SFP managed switch
The description of the IFS NS3550-2T-8S model is as follows:
Industrial L2+ 8-port Gigabit Fiber (SFP) managed switch
+ 2-port 10/100/1000T
Unless specified, the terms “industrial managed switch” andindustrial managed
switchesmentioned in this user manual refers to the NS3552-8P-2S and/or NS3550-
2T-8S.
Package contents
Open the box of the industrial managed switch and carefully unpack it. The box should
contain the following items:
The industrial managed switch × 1
Quick installation guide × 1
CD with user manual × 1
DIN rail kit x 1
Wall mounting kit x 1
RS232 console cable x 1
SFP dust-proof cap x 2
RJ45 dust-proof cap x 9
If any of these are missing or damaged, contact your dealer immediately. If possible,
retain the carton including the original packing materials for repacking the product in
case there is a need to return it to us for repair.
Chapter 1: Introduction
NS3552-8P-2S and NS3550-2T-8S User Manual 5
Product description
Environmentally hardened design
With IP30 aluminum case protection, the industrial managed switches provide a high
level of immunity against electromagnetic interference and heavy electrical surges
which are usually found on plant floors or in curb-side traffic control cabinets. It also
possesses an integrated power supply source with a wide range of voltages for
worldwide high availability applications requiring dual or backup power inputs. Being
able to operate under the temperature range from -40 to 75°C, the industrial managed
switch can be placed in almost any difficult environment.
Digital input and digital output for external alarm
The industrial managed switches support digital input and digital output on their front
panels. The external alarm allows users to use the digital input to detect an external
device’s status (such as a door intrusion detector), and send an event alarm to the
administrators. The digital output can be used to alarm the administrators if the
industrial managed switch port is link-down, link-up, or power-dead.
Chapter 1: Introduction
6 NS3552-8P-2S and NS3550-2T-8S User Manual
Robust layer 2 features
The industrial managed switches can be programmed for advanced switch
management functions such as dynamic port link aggregation, Q-in-Q VLAN, Multiple
Spanning Tree Protocol (MSTP), layer 2 to layer 4 QoS, bandwidth control, and IGMP /
MLD snooping. The industrial managed switch allows the operation of a high-speed
trunk combining multiple ports. The NS3552-8P-2S provides 802.1Q tagged VLAN and
a maximum of 255 VLAN groups. The NS3552-8P-2S not only allows the operation of a
high-speed trunk combining multiple ports, but also supports connection fail-over.
Efficient management
For efficient management, the industrial managed switches are equipped with console,
web, and SNMP management interfaces. With the built-in web-based management
interface, the industrial switches offers an easy-to-use, platform-independent
management and configuration facility. The NS3552-8P-2S supports standard Simple
Network Management Protocol (SNMP) and can be managed by any management
software based on the standard SNMP v1 or v2 protocol. For text-based management
mode, the NS3552-8P-2S can be accessed via Telnet and the console port. Moreover,
the industrial managed switches offer secure management remotely by supporting
SSH, SSL, and SNMP v3 connections where the packet content can be encrypted at
each session.
Powerful security
The industrial switches offer comprehensive layer 2 to layer 4 access control list (ACL)
for enforcing security to the edge. It can be used to restrict to network access by
denying packets based on source and destination IP address, TCP/UDP port number,
or defined typical network applications. Its protection mechanism also comprises
802.1x port-based and MAC-based user and device authentication. With the private
VLAN function, communication between edge ports can be prevented to ensure user
privacy. The industrial switches also provide DHCP snooping, IP Source Guard and
Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP
packets with invalid MAC addresses. The network administrator can now construct
highly secured corporate networks in considerably less time and with less effort than
before.
Chapter 1: Introduction
NS3552-8P-2S and NS3550-2T-8S User Manual 7
Flexible and extendable solution
The industrial managed switches feature 100BASE-FX and 1000BASE-SX/LX SFP
(Small Form-factor Pluggable) fiber-optic modules, meaning the administrator now can
flexibly choose the suitable SFP transceiver according to the transmission distance or
the transmission speed required to extend the network efficiently. The distance can be
extended from 550 m to 2 km (multi-mode fiber) up to above 10/20/30/40/50/70 km
(single-mode fiber or WDM fiber). They are well suited for applications within enterprise
data centers and distributions.
PoE functions for PD management (NS3552-8P-2S only)
Redundant ring, fast recovery for surveillance systems
The NS3552-8P-2S supports redundant ring technology and features strong, rapid self-
recovery capability to prevent interruptions and external intrusions. It incorporates
advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology,
Spanning Tree Protocol (802.1s MSTP), and redundant power input system into the
customer’s industrial automation network to enhance system reliability and uptime in
harsh factory environments. In a certain simple ring network, the recovery time of data
link can be as fast as 20 ms.
Chapter 1: Introduction
8 NS3552-8P-2S and NS3550-2T-8S User Manual
Intelligent powered device alive check
The NS3552-8P-2S can be configured to monitor connected powered device (PD)
status in real time via a ping action. After the PD stops working and responding, the
industrial managed switch resumes the PoE port power and puts the PD back to work.
TheNS3552-8P-2S greatly enhances the network reliability through the PoE port
resetting the PD’s power source and reducing the administrator management burden.
PoE schedule for energy saving
Under the trend of energy saving worldwide and contributing to environmental
protection, the NS3552-8P-2S can effectively control the power supply in addition to its
capability of providing high Watt power. The “PoE schedule” function helps you to
enable or disable PoE power feeding for each PoE port during specified time intervals,
and is a powerful function to help SMBs or enterprises save power and money.
Chapter 1: Introduction
NS3552-8P-2S and NS3550-2T-8S User Manual 9
IPv6/IPv4 full-function secure switch for building automation networking
The NS3552-8P-2S is the ideal solution to fulfilling the demand of IPv6 management
gigabit Ethernet switches, especially in the industrial-hardened environment. It supports
both IPv4 and IPv6 protocols, advanced layer 2 to layer 4 data switching and
redundancy, QoS traffic control, network access control and authentication, and secure
management features to protect customer’s industrial and building automation network
connectivity with reliable switching recovery capability that is suitable for implementing
fault tolerant and mesh network architectures.
Perfect integration solution for outdoor IP PoE camera and NVR system
The NS3552-8P-2S provides eight 10/100/1000 Mbps 802.3af/at PoE ports and offers
sufficient PoE power for eight PoE IP cameras at the same time. In addition, with the 2-
Port 100/1000Base-X SFP interfaces, the NS3552-8P-2S can connect to a core fiber
switch and send video streams to NVRs and monitor centers. Through the high
performance switch architecture, the NS3552-8P-2S facilitates the recorded video files
from the eight PoE IP cameras to be saved in the NVR systems.
Furthermore, the NVR systems can be controlled and monitored both in the local LAN
and the remote site via Internet. The NS3552-8P-2S undoubtedly brings an ideal,
secure surveillance system at a lower total cost.
Chapter 1: Introduction
10 NS3552-8P-2S and NS3550-2T-8S User Manual
Product features
Physical portNS3552-8P-2S
Eight 10/100/1000BASE-T gigabit Ethernet RJ45 ports with IEEE 802.3af / 802.3at
PoE injector.
Two 100/1000BASE-X mini-GBIC/SFP slots, SFP type auto detection.
One RJ45 console interface for basic management and setup.
Physical port NS3550-2T-8S
Two 10/100/1000BASE-T gigabit Ethernet RJ45 ports.
Eight 100/1000BASE-X mini-GBIC/SFP slots, SFP type auto detection.
One RJ45 console interface for basic management and setup.
Power over Ethernet (NS3552-8P-2S only)
Complies with IEEE 802.3af / IEEE 802.3at Power over Ethernet / End-Span PSE.
Complies with IEEE 802.3af Power over Ethernet / End-Span PSE.
Up to four ports of IEEE 802.3af/IEEE 802.3at devices powered.
Supports PoE power up to 15.4 W or 30.8 W for each PoE port.
Auto detects powered device (PD).
Circuit protection prevents power interference between ports.
Remote power feeding up to 100 m.
PoE management:
IEEE 802.3af and IEEE 802.3at mode switch control
Total PoE power budget control
Per port PoE function enable/disable
PoE admin-mode control
PoE port power feeding priority
Per PoE port power limitation
PD classification detection
Intelligent PoE features:
Temperature threshold control
PoE usage threshold control
PD alive check
PoE schedule
PD power recycling schedule
Chapter 1: Introduction
NS3552-8P-2S and NS3550-2T-8S User Manual 11
Industrial case and installation
IP30 aluminum case
DIN-rail and wall-mount design
48 VDC redundant power with polarity reverse protect function
Supports 6000 VDC EFT protection for power line
Supports Ethernet ESD protection for 6000 VDC
-40 to 75°C operating temperature
Digital input and digital output
Two Digital Inputs (DI)
Two Digital Outputs (DO)
Integrates sensors into auto alarm system
Transfers alarm to IP network via email and SNMP trap
Layer 2 features
Prevents packet loss with back pressure (half-duplex) and IEEE 802.3x PAUSE
frame flow control (full-duplex).
High performance of Store-and-Forward architecture and runt/CRC filtering
eliminates erroneous packets to optimize the network bandwidth.
Storm control support:
Broadcast / Multicast / Unknown-Unicast
Supports VLAN
IEEE 802.1Q tagged VLAN
Up to 255 VLANs groups out of 4094 VLAN IDs
Provider bridging (VLAN Q-in-Q) support (IEEE 802.1ad)
Private VLAN Edge (PVE)
Protocol-based VLAN
MAC-based VLAN
Voice VLAN
Supports STP
STP, IEEE 802.1D Spanning Tree Protocol
RSTP, IEEE 802.1w Rapid Spanning Tree Protocol
MSTP, IEEE 802.1s Multiple Spanning Tree Protocol, spanning tree by VLAN
BPDU Guard
Chapter 1: Introduction
12 NS3552-8P-2S and NS3550-2T-8S User Manual
Supports link aggregation
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
Cisco ether-channel (static trunk)
Maximum five trunk groups, up to eight ports per trunk group
Up to 16 Gbps bandwidth (duplex mode)
Provides port mirror (many-to-1)
Port mirroring to monitor the incoming or outgoing traffic on a particular port
Loop protection to avoid broadcast loops
Supports Ethernet Ring Protection Switching (ERPS)
Quality of Service
Ingress shaper and egress rate limit per port bandwidth control
Eight priority queues on all switch ports
Traffic classification:
- IEEE 802.1p CoS
- TOS / DSCP / IP Precedence of IPv4/IPv6 packets
- IP TCP/UDP port number
- Typical network application
Strict priority and Weighted Round Robin (WRR) CoS policies
Supports QoS and In/Out bandwidth control on each port
Traffic-policing policies on the switch port
DSCP remarking
Multicast
Supports IGMP snooping v1, v2, and v3
Supports MLD snooping v1 and v2
Querier mode support
IGMP snooping port filtering
MLD snooping port filtering
Multicast VLAN Registration (MVR) support
Security
Authentication
IEEE 802.1x Port-Based / MAC-Based network access authentication
Built-in RADIUS client to co-operate with the RADIUS servers
Chapter 1: Introduction
NS3552-8P-2S and NS3550-2T-8S User Manual 13
TACACS+ login users access authentication
RADIUS / TACACS+ users access authentication
IP-based Access Control List (ACL)
MAC-based ACL
Source MAC / IP address binding
DHCP snooping to filter distrusted DHCP messages
Dynamic ARP inspection discards ARP packets with invalid MAC addresses to IP
address binding.
IP source guard prevents IP spoofing attacks.
Auto DoS rule to defend against DoS attacks.
IP address access management to prevent unauthorized intruders.
Management
Switch management interfaces:
Console / Telnet Command Line Interface
Web switch management
SNMP v1 and v2c switch management
SSH / SSL and SNMP v3 secure access
IPv6 IP address/NTP/DNS management
Built-in Trivial File Transfer Protocol (TFTP) client
System maintenance
- Firmware upload/download via HTTP / TFTP
- Reset button for system reboot or reset to factory default
Four RMON groups (history, statistics, alarms, and events)
IPv6 IP address / NTP / DNS management and ICMPv6
BOOTP and DHCP for IP address assignment
DHCP relay
DHCP Option 82
User privilege levels control
NTP (Network Time Protocol)
Link Layer Discovery Protocol (LLDP) and LLDP-MED
SFP-DDM (Digital Diagnostic Monitor)
Smart discovery utility for deploy management
Network diagnostic
Chapter 1: Introduction
14 NS3552-8P-2S and NS3550-2T-8S User Manual
Cable diagnostic technology provides the mechanism to detect and report
potential cabling issues
Product specifications
Model Name
NS3552
-8P-2S NS3550-2T-8S
Hardware Specification
s
Copper
Ports
Two
10/100/1000BASE-T RJ45s
Two 10/100/1000BASE-T Ethernet
interface
SFP
+ Slots
Eight 1000BASE
-SX/LX/BX SFP
interfaces
Compatible with 1000BASE
-FX SFP
Eight 100/1000BASE-SX/LX mini-
GBIC SFP slots
Console Port
1 x RS
-232 to RJ45
serial port (115200,
8, N, 1)
Switch Architecture
Stor
e-and-Forward Store-and-Forward
Switch
Fabric
20
Gbps / non-blocking 20 Gbps / non-blocking
Throughput
14.8
Mpps @ 64 bytes 14.8 Mpps
Address Table
8
K entries, automatic source address
learning and ag
ing
8K entries, automatic source
address learning and aging
Share
d Data Buffer
4 Mbits
Flow Control
IEEE 802.3x
pause frame for full-duplex
Back pressure for
half-duplex
IEEE 802.3x pause frame for full-
duplex
Back pressure for half-duplex
Jumbo Frame
9
K bytes 9K bytes
Reset Button
< 5 seconds: System reboot
>
5 seconds: Factory Default
< 5 seconds: System reboot
> 5 seconds: Factory Default
Enclosure
IP30 aluminum case
IP30 aluminum case
Installation
DIN rail kit and wall
-mount kit DIN rail kit and wall-mount kit
Connector
Removable 6
-pin terminal block for
power input
Pin 1/2 for Power 1, Pin 3/4 for fault
alarm, Pin 5/6 for Power 2
Removable 6
-pin terminal block for
DI/DO interface
Pin 1/2 for DI 1 & 2, Pin 3/4 for DO 1 &
2, Pin 5/6 for GND
Alarm
One relay output for power failure.
Alarm relay current carry ability:
1A @ 24
VDC
One relay output for power failure.
Alarm relay current carry ability:
1A @ 24 VDC
Digital Input
Two Digital Inputs (DI)
Chapter 1: Introduction
NS3552-8P-2S and NS3550-2T-8S User Manual 15
Level 0: -24~2.1 V (±0.1 V)
Level 1: 2.1~24 V
(±0.1 V)
Input load to 24 VDC, 10 mA max.
Digital Output
Two Digital Outputs (DO)
Open collector to 24 VDC, 100 mA
max.
LED
System:
Power 1 (Green)
Power 2 (Green)
Fault Alarm (Green)
Ring (Green)
Ring Owner (Green)
Per 10/100/1000T RJ45 Ports:
PoE in-use (Orange)
1000 LNK/ACT (Green)
Per SFP Interface:
100 LNK/ACT (Orange)
1000 LNK/ACT (Green)
System:
Power 1 (Green)
Power 2 (Green)
Fault Alarm (Green)
Ring (Green)
Ring Owner (Green)
Per 10/100/1000T RJ45 Ports:
10/100 LNK/ACT (Orange)
1000 LNK/ACT (Green)
Per SFP Interface:
100 LNK/ACT (Orange)
1000 LNK/ACT (Green)
Dimensions
152 x 107
x 72 mm 152 x 107 x 72 mm
Weight
1.684 kg
1.036 kg
Power Requirement
D
C 48 V
DC 12 to 48 V, 24 VAC power
adapter
Power
Consumption
At/31.9
W / 108.78 BTU (full loading
without PoE function)
306
W / 1043.46 BTU (full loading with
PoE function)
13.92 W / 47.76 BTU (full loading)
ESD Protection
6K VDC
6K VDC
EFT Protection
6K VDC
6K VDC
Power over Ethernet
PoE Standard
IEEE 8
02.3af/802.3at PoE / PSE
PoE Power
Supply Type
End
-span
PoE Power Output
IEEE 802.3af Standard
Per port 56 VDC, 350 mA. Max.
15.4 W.
IEEE 802.3at Standard
Per port 56 VDC, 590 mA. Max. 30
W.
Power Pin Assignment
End
-span: 1/2(-), 3/6(+)
PoE Power Budget
27
0 W maximum (depending on power
input)
Chapter 1: Introduction
16 NS3552-8P-2S and NS3550-2T-8S User Manual
Max. number of Class 2
PD
8
Max. number of Class 3
PD
8
Max. number of Class 4
PD
8
Layer 2
Functions
Basic Management
Interfaces
Console; Telnet; Web browser; SNMP
v1, v2c
Web browser; Remote Telnet,
SNMP v1, v2c
Secure
Management
Interfaces
SSH, SSL, SNMP v3
Port
Configuration
Po
rt disable / enable
Auto
-negotiation 10/100/1000Mbps full
and half duplex mode selection
Flow
control disable/enable
Power saving mode control
Port disable / enable
Auto-negotiation 10/100/1000Mbps
full and half duplex mode selection.
Auto-detection / Forced
100/1000Mbps SFP Fiber
transceiver speed.
Flow control disable/enable
Power saving mode control
Port Status
Display each port’s speed duplex mode,
link status,
flow control status, auto-
neg
otiation status, trunk status.
Display each port’s speed duplex
mode, link status, flow control status,
auto-negotiation status, trunk status.
Port Mirroring
TX / RX / both
1
-to-1 monitor
TX / RX / both
Many-to-1 monitor
VLAN
802.1Q tagged
-based VLAN, up to 255
VLAN groups
Q
-in-Q tunneling
Private VLAN
Edge (PVE)
MAC
-based VLAN
Protocol
-based VLAN
Voice VLAN
MVR (Multicast VLAN Registration)
U
p to 255 VLAN groups, out of 4094
VLAN IDs
802.1Q tagged-based VLAN, up to
255 VLAN groups
Q-in-Q tunneling
Private VLAN
MAC-based VLAN
Protocol-based VLAN
Voice VLAN
MVR (Multicast VLAN Registration)
Up to 255 VLAN groups, out of 4095
VLAN ID
Link Aggregation
IEEE 802.3ad LACP
/static trunk
Five groups with eight
ports per trunk
IEEE 802.3ad LACP/static trunk
Five groups with 10 ports per trunk
QoS
Traffic classification based,
s
trict priority
and WRR
8
-level priority for switching
Port number
802.1p priority
802.1Q VLAN tag
DSCP/ToS field in IP packet
Traffic classification based, strict
priority and WRR
8-level priority for switching
Port number
802.1p priority
802.1Q VLAN tag
DSCP/ToS field in IP packet
IGMP Snooping
IGMP (v1/v2
/v3) snooping, up to 255
multicast
groups
IGMP (v1/v2/v3) snooping, up to 255
multicast groups
Chapter 1: Introduction
NS3552-8P-2S and NS3550-2T-8S User Manual 17
IGMP querier mode support
MLD Snooping
MLD (v1/v2)
snooping, up to 255
multicast
groups
MLD
querier mode support
MLD (v1/v2) snooping, up to 255
multicast groups
MLD querier mode support
Access Control List
IP
-based ACL / MAC-based ACL
Up to
123 entries
IP-based ACL / MAC-based ACL
Up to 256 entries
Bandwidth Control
Per port bandwidth control
Ingress: 500 Kbps~1000 Mbps
Egress: 500 Kbps~1000 Mbps
Per port bandwidth control
Ingress: 500 Kbps~1000 Mbps
Egress: 500 Kbps~1000 Mbps
Standards Conformance
Regulation Compliance
FCC Part 15 Class A, CE
FCC Part 15 Class A, CE
Stability Testing
IEC60068
-2-32 (Free fall)
IEC60068
-2-27 (Shock)
IEC60068
-2-6 (Vibration)
IEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
Standards Compliance
IEEE
802.3 10BASE-T
IEEE
802.3u 100BASE-TX/100BASE-
FX
IEEE
802.3z Gigabit SX/LX
IEE
E 802.3ab Gigabit 1000T
IEEE 802.3x flow control and back
pressure
IEEE 802.3ad port trunk with LACP
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree
Protocol
IEEE 802.1s Multiple Spanning Tree
Protocol
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN tagging
IEEE 802.1X Port Authentication
Network Control
IEEE 802.1ab LLDP
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power
over Ethernet Plus
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 2068 HTTP
RFC 1112 IGMP v1
RFC 2236 IGMP v2
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX /
100Base-FX
IEEE 802.3z Gigabit SX/LX
IEEE 802.3ab Gigabit 1000T
IEEE 802.3x Flow Control and Back
pressure
IEEE 802.3ad Port trunk with LACP
IEEE 802.1D Spanning Tree
Protocol
IEEE 802.1w Rapid Spanning Tree
Protocol
IEEE 802.1s Multiple Spanning Tree
Protocol
IEEE 802.1p Class of service
IEEE 802.1Q VLAN Tagging
IEEE 802.1x Port Authentication
Network Control
IEEE 802.1ab LLDP
SNMP MIBs
RFC 1213 MIB
-II
IF
-MIB
RFC 1493 Bridge MIB
RFC 1643 Ethernet MIB
RFC-1213 MIB-II
RFC-2236 IGMPv2
RFC-2710 MLDv1
RFC-3376 IGMPv3
Chapter 1: Introduction
18 NS3552-8P-2S and NS3550-2T-8S User Manual
RFC 2863 Interface MIB
RFC 2665 Ether
-Like MIB
RFC 2819 RMON MIB (Groups 1, 2, 3
and 9)
RFC 2737 Entity MIB
RFC 2618 RADIUS Client MIB
RFC 2933 IG
MP-STD-MIB
RFC 3411 SNMP
-Frameworks-MIB
IEEE 802.1X PAE
LLDP
MAU
-MIB
RFC-1493 Bridge MIB
RFC-1643 Ethernet MIB
RFC-2863 Interface MIB
RFC-2665 Ether-Like MIB
RFC-2819 RMON MIB (Group 1, 2,
3 and 9)
RFC-2737 Entity MIB
RFC-2618 RADIUS Client MIB
RFC3411 SNMP-Frameworks-MIB
IEEE 802.1X PAE
IF-MIB
LLDP
MAU-MIB
Environment
Operating
Temperature:
-40 to 75°C
Relative Humidity:
5 to 95% (non-
condensing)
Temperature: -40 to 75°C
Relative Humidity: 5 to 95% (non-
condensing)
Storage
Temperature:
-40 to 85°C
Relative Humidity:
5 to 95% (non-
condensing)
Temperature: -40 to 85°C
Relative Humidity: 5 to 95% (non-
condensing)
/